Background: Patients may require perioperative cooling for a variety of reasons including treatment of a malignant hyperthermia crisis and induction of therapeutic hypothermia for neurosurgery. The authors compared heat transfer and core cooling rates with five cooling methods.
Methods: Six healthy volunteers were anesthetized with desflurane and nitrous oxide. The cooling methods were 1) circulating water (5 [degree sign] Celsius, full-length mattress and cover), 2) forced air (10 [degree sign] Celsius, full-length cover), 3) gastric lavage (500 ml iced water every 10 min), 4) bladder lavage (300 ml iced Ringer's solution every 10 min), and 5) ice-water immersion. Each method was applied for 40 min or until the volunteers' core temperatures approached 34 [degree sign] Celsius. The volunteers were rewarmed to normothermia between treatments. Core cooling rates were evaluated using linear regression.
Results: The first volunteer developed abdominal cramping and diarrhea after gastric lavage. Consequently, the technique was not again attempted. Bladder lavage increased heat loss 10 [nearly =] 10 W and decreased core temperature 0.8 +/- 0.3 [degree sign] Celsius/h (r2 = 0.99 +/- 0.002; means +/- SD). Forced-air and circulating-water cooling comparably increased heat flux, [nearly =] 170 W. Consequently, core cooling rates were similar during the two treatments at 1.7 +/- 0.5 [degree sign] Celsius/h (r2 = 0.99 +/- 0.001) and 1.6 +/- 1.1 [degree sign] Celsius/h (r2 = 0.98 +/- 0.02), respectively. Immersion in an ice water slurry increased heat loss [nearly =] 600-800 W and decreased core temperature 9.7 +/- 4.4 [degree sign] Celsius/h (r sup 2 = 0.98 +/- 0.01). Immersion cooling was associated with an afterdrop of [nearly =] 2 [degree sign] Celsius. 相似文献
From June 1988 to June 1990 we studied fifty patients who had implantation of a pacemaker. (31 females and 19 males). All of them underwent stress test with Bruce's protocol. Patients were divided in two groups; pacemaker-independent (PI) and pacemaker-dependent (PD). Over 50% of the patients inhibited the pacemaker with their own rhythm, most of them had sinus dysfunction. Complete A-V block was predominant in PD. The group of PI achieved more mets and had more oxygen consumption. Blood pressure response was similar in both groups. 相似文献
Background: Sweating, vasoconstriction, and shivering have been observed during general anesthesia. Among these, vasoconstriction is especially important because-once triggered-it minimizes further hypothermia. Surprisingly, the core-temperature plateau associated with vasoconstriction appears to preserve core temperature better in infants and children than adults. This observation suggests that vasoconstriction in anesthetized infants may be accompanied by hypermetabolism. Consistent with this theory, unanesthetized infants rely on nonshivering thermogenesis to double heat production when vasoconstriction alone is insufficient. Accordingly, the authors tested the hypothesis that intraoperative core hypothermia triggers nonshivering thermogenesis in infants.
Methods: With Ethics Committee approval and written parental consent, the authors studied six infants undergoing abdominal surgery. All were aged 1 day to 9 months and weighed 2.4-9 kg. Anesthesia was maintained with propofol and fentanyl. The infants were mechanically ventilated and allowed to cool passively until core (distal esophageal) temperatures reached 34-34.5 degrees Celsius. Oxygen consumption-the authors' index of metabolic rate- was recorded throughout cooling. Because nonshivering thermogenesis triples circulating norepinephrine concentrations, arterial blood was analyzed for plasma catecholamines at [nearly equal] 0.5 degrees Celsius intervals. Thermoregulatory vasoconstriction was evaluated using forearm - fingertip, skin-surface gradients, with gradients exceeding 4 degrees Celsius, indicating intense vasoconstriction. The patients were subsequently rapidly rewarmed to 37 degrees Celsius. Regression analysis was used to correlate changes in oxygen consumption and plasma catecholamine concentrations with core temperature.
Results: All patients were vasoconstricted by the time core temperature reached 36 degrees Celsius. Further reduction in core temperature to 34-34.5 degrees Celsius did not increase oxygen consumption. Instead, oxygen consumption decreased linearly. Hypothermia also failed to increase plasma catecholamine concentrations. 相似文献
A comparative study of indomethacin controlled release from poly(lactide-co-glycolide) (50:50, molecular weight 3000) (PLGA) microspheres loaded with two different amounts of drug (10.9 ± 1%, and 34.1 ± 1% w/w) and pure free indomethacin, considering the effects exerted by the drug on the thermotropic behavior of dipalmitoylphosphatidylcholine multilamellar vesicles, was carried out by differential scanning calorimetry (DSC). The release was monitored by comparing the effect exerted by the free indomethacin on lipid thermotropic behavior with that of the drug released by the microspheres and relating these effects to a lipid aqueous dispersion containing the molar ratio of drug able to cause it. By DSC measurements, the pure free indomethacin was found to be able to have a fluidifying effect on the model membrane, causing a shift toward lower values of the transitional temperature (Tm), characteristic of phospholipid liposomes, without variations in the enthalpic changes (ΔH). This shift was found to be modulated by the drug molar fraction with respect to the lipid concentration in the aqueous dispersion. Successively, calorimetric measurements were performed on suspensions of blank liposomes added to weighed amounts of unloaded and indometha-cin-loaded microspheres as well as free powdered indomethacin, and the Tm shifts of the lipid bilayer caused by the drug released from the polymeric system, as well as by the free drug, were compared with that caused by free drug increasing molar fractions dispersed directly on the membrane, employed as a calibration curve to obtain the fraction of drug released. This drug release model could be employed to determine the different kinetics involved in the drug transfer from the microspheres to a membrane. This in vitro study suggests that the kinetic process involved in drug release is influenced by the amount of drug loaded in the microspheres. This calorimetric study shows that the PLGA microspheres are a good delivery system able to sustain drug release. Moreover, the DSC technique applied to the drug interaction with biomembranes constitutes a good tool for determining the drug release representing an innovative alternative in vitro model. 相似文献
We present here the clinical results with a second-generation porcine bioprosthesis, the Carpentier-Edwards supra-annular valve (CESA). Two-hundred and twenty-two CESA bioprostheses were implanted in 189 patients during a four-year period (from 1984 to 1987), either as an isolated procedure or associated to mitral or tricuspid repair. The mid-term clinical results have been evaluated after a mean follow-up of 3.4 years, being 96% complete. There were 16 in-hospital deaths (8.4%) and 6 late, potentially valve-related, cardiac deaths (1.1% patients/year). Overall, 86.7 +/- 2% of the patients were free from cardiac death at 6 years (95.1 +/- 2% of the patients surviving the operative period). Linearized rates of valve related complications were the following: 1.4% patients/year for thromboembolism (including valve thrombosis), 0.5% patients/year for treatment-related hemorrhage and 0.7% patients/year for endocarditis. We did not found any case of either intrinsic or extrinsic valve failure, unrelated to infection of thrombosis. Two patients were reoperated, one because of valve thrombosis and the other due to prosthetic valve endocarditis (reoperation rate of 0.3% patients/year). When lethal and nonlethal valve-related complications (including in-hospital deaths) were considered all together, 75.8 +/- 8.4% of the patients remained alive and free of morbid events at 6 years. When patients were grouped according to the valve replaced (aortic, mitral and multiple), best results were found with patients submitted to isolated aortic valve replacement. We conclude that the CESA bioprosthesis has an excellent mid-term clinical performance. However, longer follow-up is necessary to know if improvement in valve design and manufacturing results in increased valve durability. 相似文献