全文获取类型
收费全文 | 295篇 |
免费 | 15篇 |
专业分类
儿科学 | 4篇 |
妇产科学 | 3篇 |
基础医学 | 21篇 |
口腔科学 | 89篇 |
临床医学 | 15篇 |
内科学 | 77篇 |
皮肤病学 | 2篇 |
神经病学 | 7篇 |
特种医学 | 4篇 |
外科学 | 43篇 |
预防医学 | 16篇 |
眼科学 | 9篇 |
药学 | 11篇 |
肿瘤学 | 9篇 |
出版年
2023年 | 3篇 |
2022年 | 15篇 |
2021年 | 28篇 |
2020年 | 8篇 |
2019年 | 11篇 |
2018年 | 13篇 |
2017年 | 14篇 |
2016年 | 4篇 |
2015年 | 5篇 |
2014年 | 20篇 |
2013年 | 31篇 |
2012年 | 20篇 |
2011年 | 28篇 |
2010年 | 17篇 |
2009年 | 12篇 |
2008年 | 16篇 |
2007年 | 16篇 |
2006年 | 20篇 |
2005年 | 11篇 |
2004年 | 8篇 |
2003年 | 4篇 |
2002年 | 2篇 |
1983年 | 1篇 |
1981年 | 1篇 |
1979年 | 1篇 |
1978年 | 1篇 |
排序方式: 共有310条查询结果,搜索用时 854 毫秒
101.
Light supplying to luting resin cements is impeded in several clinical situations, causing us to question whether materials
can properly be cured to achieve adequately (or adequate) mechanical properties. The aim of this study was therefore to analyse
the effect of light on the micro-mechanical properties of eight popular dual-cured self-adhesive resin cements by comparing
them with two conventional, also dual-cured, resin cements. Four different curing procedures were applied: auto-polymerisation
(dark curing) and light curing (LED unit, Freelight 2, 20 s) by applying the unit directly on the samples’ surface, at a distance
of 5 and 10 mm. Twenty minutes after curing, the samples were stored for 1 week at 37°C in a water-saturated atmosphere. The
micro-mechanical properties–Vickers hardness, modulus of elasticity, creep and elastic/plastic deformation–were measured.
Data were analysed with multivariate ANOVA followed by Tukey’s test and partial eta-squared statistics (p < 0.05). A very strong influence of the material as well as filler volume and weight on the micro-mechanical properties was
measured, whereas the influence of the curing procedure and type of cement–conventional or self-adhesive–was generally low.
The influence of light on the polymerisation process was material dependent, with four different behaviour patterns to be
distinguished. As a material category, significantly higher micro-mechanical properties were measured for the conventional
compared to the self-adhesive resin cements, although this difference was low. Within the self-adhesive resin cements group,
the variation in micro-mechanical properties was high. The selection of suitable resin cements should be done by considering,
besides its adhesive properties, its micro-mechanical properties and curing behaviour also. 相似文献
102.
Nicoleta O. Kolozsvari Giovanni Capretti Pepa Kaneva Amy Neville Franco Carli Sender Liberman Patrick Charlebois Barry Stein Melina C. Vassiliou Gerald M. Fried Liane S. Feldman 《Surgical endoscopy》2013,27(1):133-138
Introduction
Both enhanced recovery programs (ERP) and laparoscopy can reduce complications and length of stay (LOS) in colon surgery. We investigated whether ERP further improved the short-term outcomes of scheduled laparoscopic colectomies.Methods
We performed an audit of all patients undergoing scheduled laparoscopic colon resection between January 2003 and August 2010 in our institution. An ERP including accelerated introduction of oral nutrition, mobilization, pain control, and catheter management was introduced in 2005. Demographic data, intra and postoperative details and 30-day ER visit and readmission rate were collected. We compared LOS and short-term outcomes for patients on the program with those receiving traditional postoperative care using Chi-square and regression models. Data are presented as median [25th, 75th percentile]. Statistical significance was defined as p < 0.05.Results
136 (46 %) of 297 eligible patients were enrolled in the ERP. At baseline, the two groups had similar demographic characteristics, but patients in the ERP were more likely to have their operation by a colorectal surgeon (p = 0.01). Patients in the ERP ate solids earlier (p < 0.001) and had earlier removal of their urinary catheter (p < 0.001). LOS was 4 [3, 6] days for both groups (p < 0.01), with more patients in the ERP discharged by POD 3 (p < 0.001). After adjusting for other variables, ERP enrolment remained an independent predictor of LOS (p < 0.01), along with age (p < 0.01) and in-hospital complications (p < 0.001). Complication rates were similar between the two groups. Patients in the ERP had significantly fewer ER visits (p = 0.02), but there were no differences in readmission rates.Conclusion
In patients undergoing scheduled laparoscopic colectomy in a university-based clinical teaching unit, ERP can further reduce length of stay and postoperative ER visits without increasing readmission rates. 相似文献103.
104.
105.
Objectives
The aim of this study was to examine the long-term effect of heat on the mechanical behaviour of conventional highly viscous glass ionomer cements. Besides, the effect of storage time was evaluated.Materials and methods
Five cements (ChemFil Rock, Riva Self Cure, Fuji IX GP Fast, Equia and Ketac Molar Aplicap) were evaluated using three different preparation methods: no heat application, application of heat by means of a LED curing unit for 20 and 60 s. Four hundred fifty bar-shaped specimens were produced, maintained in distilled water at 37 °C and tested after 1 week, 1 month and 3 months (n?=?10). The Vickers hardness, indentation modulus and creep were measured. In addition, the amount and size of the glass fillers and voids were examined using a light and a scanning electron microscope.Results
Fuji IX GP Fast showed the highest Vickers hardness, Ketac Molar Aplicap showed the highest indentation modulus and the best value of creep was measured for Riva Self Cure. Vickers hardness, modulus of elasticity and creep resistance increased most for ChemFil Rock and Equia up to 1-month storage.Conclusions
Heat application showed no effect on the mechanical behaviour of ChemFil Rock, Fuji IX GP Fast and Equia at all ageing time. The impact of storage duration was low.Clinical relevance
Considering the measured mechanical properties, there is no need of using heat when restoring teeth with glass ionomer cements. 相似文献106.
Objectives
This study aimed to describe the polymerization process and to quantify the parameters of influence in two bulk-fill resin-based composites by comparing two real-time methods: the Fourier transform infrared (FTIR) spectroscopy and the visible light transmission spectrometry.Materials and methods
The degree of conversion (DC) was recorded in real time for 5 min using the attenuated total reflectance FTIR spectroscopy (n?=?6) on the lower surface of 2, 4, and 6 mm thick samples irradiated for 20 s. The variation in irradiance was recorded during material irradiation at the bottom of the samples (n?=?5). Results were statistically analyzed using one-way and multiple-way ANOVAs with Tukey HSD post hoc test (α?=?0.05), partial eta-squared statistics, and Pearson correlation.Results
No significant difference was found in DC in any materials as a function of incremental thickness, whereas the irradiance passing the specimens differed consistently within both analyzed increments and materials. These data could be described by the superposition of two exponential functions, the first being attributed to the gel phase and the second to the glass phase, resulting in an exponential sum function. DC data were able to calculate the end of the gel phase and the beginning of the glass phase, whereas irradiance measurements were able to detect only the last phase. The polymerization kinetics in the glass phase was less material-dependent as in the gel phase.Conclusions
The irradiance measurements were more sensitive to variation in thickness, meaning that translucency is continuing to change as a function of thickness at a higher extent than DC.Clinical relevance
Knowing the impact of the modulation factors describing the calculated sum exponential function allows the manipulation of the polymerization process at different stages to tailor material properties. 相似文献107.
Objectives
This study aimed to evaluate whether sonic-activated resin-based composites (RBCs) used as repair materials might improve the repair bond strength of aged RBC substrates.Materials and methods
Five RBCs were repaired by themselves and by all other materials. The repair was applied with and without sonic activation, resulting in 50 material application technique combinations (n?=?15) and 750 specimens. The cohesive strength of the five materials was used as control (n?=?15). Substrates were aged for 8 weeks in distilled water at 37 °C, roughened, cleaned with phosphoric acid, and repaired by using a silane primer and an adhesive as intermediate agents. The repair bond strength was assessed in a shear test. The modulus of elasticity (E) of the five RBCs was additionally evaluated in a three-point bending test.Results
Results were compared using one- and multiple-way analyses of variance and Tukey’s honestly significant difference post hoc test (α?=?0.05), partial eta-square statistics, Pearson’s correlation, and Weibull’s analysis. No significant effect of sonic activation on the repair material was found in any material combination. The repair strength was 35.4–90.9 % of the cohesive strength of the original composites. E varied between 4.1 GPa (CLEARFIL MAJESTY Esthetic) and 9.7 GPa (CLEARFIL MAJESTY Posterior). The strongest influence on the shear bond strength was performed by E repair (η 2 P?=?0.167), whereas the effect of E substrate was significant but low (η 2 P?=?0.098). None of these parameters influenced the reliability of the repaired specimens (the Weibull parameter, m). The fracture pattern was mainly cohesive (93.3 %) in the control group and predominantly adhesive (89.2 %) in the repaired specimens.Conclusions
Except for the material with the highest modulus of elasticity used as a substrate material, it was not detrimental to combine different RBCs in terms of repair.Clinical relevance
If a substrate material is unknown, the recommendation for repairing would be in favor of a material with a high modulus of elasticity. 相似文献108.
Objectives
The aim of this study was to quantify the blue light that passes through different incremental thicknesses of bulk fill in comparison to conventional resin-based composites (RBCs) and to relate it to the induced mechanical properties.Materials and methods
Seven bulk fill, five nanohybrid and two flowable RBCs were analysed. Specimens (n?=?5) of three incremental thicknesses (2, 4 and 6 mm) were cured from the top for 20 s, while at the bottom, a spectrometer monitored in real time the transmitted irradiance. Micro-mechanical properties (Vickers hardness, HV, and indentation modulus, E) were measured at the top and bottom after 24 h of storage in distilled water at 37 °C. Electron microscope images were taken for assessing the filler distribution and size.Results
Bulk fill RBCs (except SonicFill) were more translucent than conventional RBCs. Low-viscosity bulk fill materials showed the lowest mechanical properties. HV depends highly on the following parameters: material (ηp 2?=?0.952), incremental thickness (0.826), filler volume (0.747), filler weight (0.746) and transmitted irradiance (0.491). The bottom-to-top HV ratio (HVbt) was higher than 80 % in all materials in 2- and 4-mm increments (except for Premise), whereas in 6-mm increments, this is valid only in four bulk fill materials (Venus Bulk Fill, SDR, x-tra fil, Tetric EvoCeram Bulk Fill).Conclusions
The depth of cure is dependent on the RBC’s translucency. Low-viscosity bulk fill RBCs have lower mechanical properties than all other types of analysed materials. All bulk fill RBCs (except SonicFill) are more translucent for blue light than conventional RBCs.Significance
Although bulk fill RBCs are generally more translucent, the practitioner has to follow the manufacturer’s recommendations on curing technique and maximum incremental thickness. 相似文献109.
Florian Beck Nicoleta Dumitrescu Franz König Alexandra Graf Peter Bauer Wolfgang Sperr Andreas Moritz Andreas Schedle 《Dental materials》2014
Objective
The aim of this prospective randomized-controlled clinical trial is to assess the long-term performance of two direct composite resins in posterior teeth. This study provides a survey of the one-year results.Materials and methods
A total of 1805 restorations were placed by students in stress-bearing Class I/II cavities (including cuspal-coverage) in molars and premolars in 456 patients. Clinical evaluation was performed at baseline and after one year using modified USPHS criteria. The restorations in each patient were performed either with Ceram X/Prime&Bond NT or Tetric Ceram/Optibond Solo Plus.Results
After one year 528 fillings with Ceram X and 580 with Tetric Ceram were available for evaluation of substance loss, contact point, color match, marginal staining, marginal adaptation, secondary caries and radiographic examination (if necessary). This represents a recall rate of 61.18% (279 patients). The failure rate per material was 5.3% in the Ceram X group and 6.1% in the Tetric Ceram group. Most of the failures were associated with marginal adaptation/integrity of the filling. A significant influence on the occurrence of a failure was observed for the number of treated teeth per patient, the age of the patient, the mesio-distal extension of the restoration and the tooth position. Gender, material, a previous root canal treatment, the bucco-lingual extension of the filling or cuspal-coverage did not significantly influence the failure rate. Patients attending the first recall were significantly older and had more fillings than patients not attending.Conclusions
In a group of Class I/II restorations (including cuspal-coverage), there was no significant difference in failure rates between ormocer-based and bis-GMA-based restorative systems after one year. A previous root canal treatment had no negative influence on the failure rate. A longer observation period is indicated to get clear evidence of the long-term performance of these composite resin systems. 相似文献110.
Clinical Oral Investigations - The study aims analyzing if improved opacity in modern high-viscosity bulk-fill resin composites (BF-RBC) contradicts with the sufficiency of curing and to assess... 相似文献