全文获取类型
收费全文 | 101篇 |
免费 | 3篇 |
专业分类
基础医学 | 6篇 |
口腔科学 | 16篇 |
临床医学 | 9篇 |
内科学 | 27篇 |
皮肤病学 | 3篇 |
神经病学 | 2篇 |
特种医学 | 8篇 |
外科学 | 30篇 |
综合类 | 1篇 |
预防医学 | 1篇 |
肿瘤学 | 1篇 |
出版年
2021年 | 1篇 |
2019年 | 2篇 |
2017年 | 5篇 |
2016年 | 1篇 |
2014年 | 2篇 |
2013年 | 1篇 |
2012年 | 3篇 |
2011年 | 4篇 |
2010年 | 4篇 |
2008年 | 2篇 |
2007年 | 9篇 |
2006年 | 8篇 |
2005年 | 13篇 |
2004年 | 5篇 |
2003年 | 7篇 |
2002年 | 14篇 |
2001年 | 3篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1997年 | 2篇 |
1996年 | 1篇 |
1994年 | 3篇 |
1993年 | 4篇 |
1992年 | 2篇 |
1991年 | 1篇 |
1990年 | 2篇 |
1980年 | 1篇 |
1969年 | 1篇 |
1968年 | 1篇 |
排序方式: 共有104条查询结果,搜索用时 15 毫秒
81.
OBJECTIVE: The purpose of this study was to evaluate the intensity of fluorescent light reflected from cavity wall dentin, after dentin stained by an experimental caries detecting liquid was removed. BACKGROUND DATA: The conventional caries detecting liquid tends to penetrate dentin too deeply. On the other hand, DIAGNOdent has gradually gained recognition and established itself as a caries detection device using a laser beam. METHOD: An experimental caries staining liquid or the conventional caries staining liquid was applied in the same cavity to observe for differences in dye penetration. Intensity of fluorescence reflected from treated dentin was measured by DIAGNOdent. RESULTS: The mean DIAGNOdent value after removing the tooth substance stained by the experimental liquid was 17.9+/-4.1, compared with 7.7+/-2.7 by conventional one. CONCLUSION: Light intensity evaluation of laser-induced fluorescence suggested that the experimental caries detecting liquid did not penetrate the dentin which should be preserved, hence avoiding overtreatment. 相似文献
82.
83.
Robert A Scott Mark E S Bailey Colin N Moran Richard H Wilson Noriyuki Fuku Masashi Tanaka Athanasios Tsiokanos Athanasios Z Jamurtas Evangelia Grammatikaki George Moschonis Yannis Manios Yannis P Pitsiladis 《European journal of human genetics : EJHG》2010,18(12):1339-1343
Studies of the fat mass and obesity-associated (FTO) gene provide compelling evidence of genetic variation in the general population that influences fat levels and obesity risk. Studies of the interaction between genetic and environmental factors such as physical activity (PA) will promote the understanding of how lifestyle can modulate genetic contributions to obesity. In this study, we investigated the effect of FTO genotype, and interactions with PA or energy intake, in young children and adolescents. In all, 1–5-year-old children from the Growth, Exercise and Nutrition Epidemiological Study in preSchoolers (GENESIS) study (N=1980) and 11–18-year-old Greek adolescents (N=949) were measured for adiposity-related phenotypes and genotyped at the FTO single-nucleotide polymorphism (SNP) marker, rs17817449. Adolescents were classified as physically active or inactive based on self-reported levels of PA. In adolescents, FTO genotype influenced weight (P=0.001) and BMI (P=0.007). There was also a significant SNP*PA*gender interaction (P=0.028) on BMI, which reflected the association between FTO genotype and BMI in males (P=0.016), but not females (P=0.15), and significant SNP*PA interaction in males (P=0.007), but not females (P=0.74). The FTO genotype effect was more pronounced in inactive than active males. Inactive males homozygous for the G allele had a mean BMI 3 kg/m2 higher than T carriers (P=0.008). In the GENESIS study, no significant association between FTO genotype and adiposity was found. The present findings highlight PA as an important factor modifying the effect of FTO genotype. 相似文献
84.
Eri Miyamoto-Mikami Haruka Murakami Hiroyasu Tsuchie Hideyuki Takahashi Nao Ohiwa Motohiko Miyachi Takashi Kawahara Noriyuki Fuku 《Journal of Science and Medicine in Sport》2017,20(1):98-103
Objectives
This study aimed to examine the association between a total genotype score (TGS) based on previously published genetic polymorphism candidates and differences in sprint/power performance.Design
Case–control association study.Methods
We analysed 21 polymorphisms, which have previously been associated with sprint/power performance and related phenotypes, in 211 Japanese sprint/power track and field athletes (77 regional, 72 national, and 62 international athletes) and 649 Japanese controls using the TaqMan SNP genotyping assay. We calculated the TGS (maximum value of 100 for the theoretically optimal polygenic score) for the 21 polymorphisms.Results
All groups exhibited similar TGSs (control: 55.9 ± 7.2, regional: 55.1 ± 7.1, national: 56.1 ± 7.4, and international: 56.0 ± 7.8, p = 0.827 by one-way analysis of variance). Nine of the 21 polymorphisms had the same direction of effect (odds ratio >1.0) as in previous studies, while 12 had the opposite direction of effect (odds ratio <1.0). Three polymorphisms (rs699 in AGT, rs41274853 in CNTFR, and rs7832552 in TRHR), which had the same direction of effect as in previous studies, were associated with international sprint/power athlete status (p < 0.05). However, after multiple testing corrections, the statistical significance of these polymorphisms was not retained.Conclusions
These results suggest that TGSs based on the 21 previously published sprint/power performance-associated polymorphisms did not influence the sprint/power athlete status of Japanese track and field athletes. However, our results maintain the possibility that three of these polymorphisms might be associated with sprint/power performance. 相似文献85.
Yamada Y Hossain M Shimizu Y Kimura Y Masuda Y Nakamura Y Matsumoto K 《Journal of dentistry》2008,36(2):130-137
OBJECTIVE: The objective of the present study was to improve fissure sealing by pre-treatment with Carisolv in order to remove organic debris. The surface morphology and roughness of fissure cavities and the degree of microleakage after Carisolv application were compared with those after bristle brush treatment in vitro. METHODS: Fifty extracted human teeth were used in this study. The teeth were randomly divided into two groups of 25 each. Artificial fissures were prepared in all teeth into which artificial organic debris was placed. The debris in 25 teeth of one group was removed using Carisolv applied for 30s and excavation was performed with a dental explorer until the gel was clear. The remaining 25 teeth were then cleaned using bristle brush with prophylaxis paste. Surface roughness was analyzed in five samples from each group by color laser three-dimensional (3D) microscopy and by scanning electron microscopic examination. The remaining samples were filled with sealant and subjected to a microleakage test under thermocycling. Statistical analysis was performed using the Mann-Whitney U-test; a value of p<0.05 was considered significant. RESULTS: Morphologically, most of the debris in the fissures was removed by Carisolv treatment, whereas some fissures were not cleaned by bristle brush. Carisolv-treatment with acid-etching resulted in removal of debris-like smear layer leaving enamel prisms open, and 3D laser microscopy demonstrated that the roughness values increased after acid-etching. However, microleakage test of both Carisolv and brush methods showed similar results. CONCLUSIONS: Carisolv-treated surfaces especially when subjected to acid-etching might facilitate good adaptation of sealant to enamel, because of an increase in surface roughness and favorable surface characteristics. 相似文献
86.
Wang X Ishizaki NT Suzuki N Kimura Y Matsumoto K 《Journal of clinical laser medicine & surgery》2002,20(5):245-250
OBJECTIVE: The purpose of this study was to investigate the morphological changes of bovine mandibular bone following Er,Cr:YSGG laser irradiation in different methods in vitro. BACKGROUND DATA: Recently, an erbium, chromium/yttrium, scandium, garmet (Er,Cr:YSGG) laser device that emits a laser beam at the wavelength of 2.78 micro m was introduced. This type of infrared laser proved to ablate dental hard tissues effectively. However, the different effects of bone ablation by this laser in different irradiation methods were still unknown. MATERIALS AND METHODS: Adult bovine mandibular bones were cut into 24 small pieces, 3-4 cm in length. The parameters of Er,Cr:YSGG laser irradiation were as follows: wavelength was 2.78 micro m, pulse duration was 140-200 micro sec, repetition rate was 20 pulse/sec, power was 4 W, spot size was 1.26 x 10(-3) mm(2), and energy density was 160 J/cm(2). Irradiation methods were different in four groups (six specimens in each group): group A, fixed position and contact mode; group B, fixed position and noncontact mode; group C, nonfixed position and contact mode; and group D, nonfixed position and noncontact mode. RESULTS: Ablation depth in group A was significantly greater than in group B (p < 0.01). In group A, thermal damage was apparent. In group B, C, and D, thermal damage was minimal. CONCLUSION: Er,Cr:YSGG laser allows for precise surgical bone cutting and ablation with minimal thermal damage to adjacent tissue. Irradiation in different methods may achieve different ablation rates and thermal damage. 相似文献
87.
Fabian Sanchis-Gomar Nuria Garatachea Zi-hong He Helios Pareja-Galeano Noriyuki Fuku Ye Tian Yasumichi Arai Yukiko Abe Haruka Murakami Motohiko Miyachi Thomas Yvert Catalina Santiago Letizia Venturini Carmen Fiuza-Luces Alejandro Santos-Lozano Gabriel Rodríguez-Romo Giovanni Ricevuti Nobuyoshi Hirose Enzo Emanuele Alejandro Lucia 《Age (Dordrecht, Netherlands)》2014,36(6):9733
Irisin might play an important role in reducing the risk of obesity, insulin resistance, or several related diseases, and high irisin levels may contribute to successful aging. Thus, the irisin precursor (FNDC5) gene is a candidate to influence exceptional longevity (EL), i.e., being a centenarian. It has been recently shown that two single-nucleotide polymorphisms (SNPs) in the FNDC5 gene, rs16835198 and rs726344, are associated with in vivo insulin sensitivity in adults. We determined luciferase gene reporter activity in the two above-mentioned SNPs and studied genotype distributions among centenarians (n = 175, 144 women) and healthy controls (n = 347, 142 women) from Spain. We also studied an Italian [79 healthy centenarians (40 women) and 316 healthy controls (156 women)] and a Japanese cohort [742 centenarians (623 women) and 499 healthy controls (356 women)]. The rs726344 SNP had functional significance, as shown by differences in luciferase activity between the constructs of this SNP (all P ≤ 0.05), with the variant A-allele having higher luciferase activity compared with the G-allele (P = 0.04). For the rs16835198 SNP, the variant T-allele tended to show higher luciferase activity compared with the G-allele (P = 0.07). However, we found no differences between genotype/allele frequencies of the two SNPs in centenarians versus controls in any cohort, and no significant association (using logistic regression adjusted by sex) between the two SNPs and EL. Further research is needed with different cohorts as well as with additional variants in the FNDC5 gene or in other genes involved in irisin signaling. 相似文献
88.
The effect of voluntary wheel-running on insulin resistance was studied in high-fat-fed rats. A sequential hyperinsulinemic euglycemic clamp procedure was employed (insulin infusion rates: 3 and 30 mU/kg BW/min) in 14 high-fat-fed rats and 7 chow-fed rats under the awake condition. The high-fat-fed rats were further divided into a sedentary (n=7) and a voluntary wheel-running (n=7) groups. Blood glucose was clamped at the fasting level in each rat. Plasma insulin levels during the 3- and 30-mU/kg BW/min insulin infusions were 40-50 and 450-550 microU/ml, respectively. At both 3 and 30 mU/kg BW/min insulin infusions, high-fat-feeding showed a significant decrease in glucose infusion rate (GIR), compared with the chow-fed rats. However, decreased GIRs were restored by the 4-wk wheel-running and reached similar levels as the chow-fed rats. Therefore, it could be concluded that voluntary wheel-running prevents insulin resistance induced by high-fat feeding. 相似文献
89.
Hossain M Nakamura Y Murakami Y Yamada Y Matsumoto K 《Journal of clinical laser medicine & surgery》2003,21(1):29-33
OBJECTIVE: This present study was performed to compare the compositional changes of human dentin and, Knoop hardness of the cavity floor prepared by Er:YAG laser irradiation with that of the conventional bur cavity. BACKGROUND DATA: There are still no reports on the compositional changes of dental hard tissues and microhardness of the cavity floor prepared by Er:YAG laser irradiation. MATERIALS AND METHODS: Fifteen laser and 15 bur cavities were cross-sectioned, and subjected to atomic analysis by SEM-EDX and Knoop hardness testing. Statistical analyses were performed using the Mann-Whitney U test; a value of p < 0.01 was considered significant. Cross sections of the remaining five laser and five bur cavities were examined by light microscopy and then by SEM. RESULTS: The results showed that the quantities of Ca (Ca weight %) and P (P weight %) were increased significantly in the laser cavities, but no significant differences were found between the Ca/P ratio and Knoop hardness number of laser and bur cavities. The results of SEM observation revealed that the lased cavity surface was irregular, and there was also the absence of a smear layer; the orifice of dentinal tubules was exposed. CONCLUSION: Er:YAG laser device produces minimal thermal induced changes of dental hard tissue compositions; Ca/P ratio and Knoop hardness of the lased cavity floor was almost similar to the bur cavities. 相似文献
90.
Kurehara K Takahashi M Kitaguchi K Furuya H 《Masui. The Japanese journal of anesthesiology》2002,51(6):642-647
We studied the effects of increases in isoflurane concentration on the bispectral index (BIS) in 16 patients undergoing lower abdominal surgery during isoflurane/epidural anesthesia. In 8 patients, the lungs were ventilated with an air/oxygen mixture (inspired oxygen fraction 0.33) [N(-) group], and in another 8 patients, the lungs were ventilated with 66% nitrous oxide in oxygen [N(+) group]. During surgery, patients received 1.0 MAC (1.15%) end-tidal isoflurane and the BIS was recorded after 10 min of unchanged end-tidal concentration. After this, we increased the end-tidal concentration of isoflurane by 0.2 MAC to 1.8 MAC. At each concentration step, the BIS was recorded again after 10 min of unchanged end-tidal concentration. At isoflurane concentration < 1.4 MAC, the BIS did not change with increasing isoflurane concentration in both groups (BIS values = about 40). In N (-) group, the BIS decreased in all patients at isoflurane concentration > 1.6 MAC. The mean BIS values were 22 (SD 18) at 1.6 MAC and 2(4) at 1.8 MAC, respectively. In N (+) group, the BIS decreased in four patients at isoflurane concentration > 1.6 MAC, and the BIS did not decrease at 1.8 MAC in another four patients. The mean BIS values were 27 (17) at 1.6 MAC and 21(21) at 1.8 MAC. The present data suggest that BIS may not correlate with anesthetic effect of isoflurane at isoflurane concentration > 1.0 MAC. 相似文献