Hypocalcaemia is a common clinical problem in patients withadvanced renal failure, frequently related to abnormal vitaminD metabolism. However, not all causes are due to 1,25-dihydroxycholecalciferoldeficiency and in this case we would like to demonstrate theconfusion which may be caused by iatrogenic pseudohypocalcaemia.   An 84-year-old man with advanced chronic renal failure (glomerularfiltration rate 15 ml/min) was admitted due to rapid deteriorationof his kidney function and was established on haemodialysis.There were  相似文献   
13.
14.
15.
Shifting towards an Opt-Out System in Greece: A General Practice Based Pilot Study     
Emmanouil K. Symvoulakis  Adelais Markaki  Christos Galanakis  Spyridon Klinis  Myfanwy Morgan  Roger Jones 《International journal of medical sciences》2013,10(11):1547-1551
New legislation in Greece towards presumed consent for organ donation, effective as of June 2013, has come at a critical moment. This pilot study aims to explore awareness, specific concerns and intentions about the new organ donation framework among patients attending Greek general practices in a rural and urban setting. Only 2.6% of respondents had a donor card, a mere 9.6% was aware of new legislation, whereas only 3.8% considered that the public had been adequately informed. Higher income respondents were more likely to be aware that they would be considered organ donors upon death, unless declared differently. Urban practice respondents were less likely to have previously discussed with a significant other their intentions in regards to presumed consent. One quarter of all respondents (22.4%) intended to carry out their right to prohibit organ removal upon death. Survey results reveal that organ donation reform has yet to be disseminated by the Greek society, underscoring the urgency for targeted information campaigns.  相似文献   
16.
17.
18.
Emergence of Q Fever Arthritis in France     
Emmanouil Angelakis  Sophie Edouard  Marie-Alix Lafranchi  Thao Pham  Pierre Lafforgue  Didier Raoult 《Journal of clinical microbiology》2014,52(4):1064-1067
Osteoarticular infection is an uncommon presentation of Q fever. Positron emission tomography (PET) scanning is a valuable tool for the diagnosis of Coxiella burnetii graft prosthesis infection and endocarditis. Our objective was to test a series of culture-negative osteoarticular samples using molecular assays for Coxiella burnetii. We tested for C. burnetii by molecular assays targeting the IS1111 and the IS30A spacer regions, using culture-negative osteoarticular samples obtained in our laboratory between January 2011and December 2012. We examine a total of 1,410 osteoarticular samples, and we observed two cases of arthritis and subacromial bursitis caused by C. burnetii. The infections were localized using PET scanning, and the diagnosis was confirmed through serology. For one, a C. burnetii strain with a multispacer sequence type 8 genotype was isolated from synovial fluid culture. Q fever articular infections could be undiagnosed because of the long evolution of articular attack, and patients with high antibody titers against C. burnetii should be tested using PET scanning to localize the site of infection.  相似文献   
19.
Modified subintimal transcatheter withdrawal: A novel technique for hematoma decompression to facilitate distal reentry during coronary chronic total occlusion recanalization     
Minh N. Vo  Emmanouil S. Brilakis  Ashish Pershad  J. Aaron Grantham 《Catheterization and cardiovascular interventions》2020,96(1):E98-E101
A controlled antegrade dissection and reentry technique is the most commonly employed crossing strategy for long coronary chronic total occlusions. The development of compressive hematoma is a recognized complication and results in the impairment of distal vessel visualization and hinders successful reentry attempts. We describe a novel technique utilizing a widely available microcatheter to decompress the subintimal hematoma to restore distal visualization and allow successful reentry.  相似文献   
20.
[首页] « 上一页 [1] 2 [3] [4] [5] [6] [7] [8] [9] [10] [11] 下一页 » 末  页»
  首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   1306篇
  免费   107篇
  国内免费   10篇
耳鼻咽喉   5篇
儿科学   47篇
妇产科学   21篇
基础医学   122篇
口腔科学   18篇
临床医学   77篇
内科学   562篇
皮肤病学   16篇
神经病学   46篇
特种医学   40篇
外科学   246篇
综合类   8篇
预防医学   71篇
眼科学   17篇
药学   39篇
中国医学   2篇
肿瘤学   86篇
  2023年   24篇
  2022年   41篇
  2021年   61篇
  2020年   30篇
  2019年   49篇
  2018年   71篇
  2017年   47篇
  2016年   47篇
  2015年   37篇
  2014年   84篇
  2013年   74篇
  2012年   150篇
  2011年   133篇
  2010年   82篇
  2009年   57篇
  2008年   91篇
  2007年   77篇
  2006年   58篇
  2005年   56篇
  2004年   50篇
  2003年   36篇
  2002年   31篇
  2001年   7篇
  2000年   9篇
  1999年   6篇
  1998年   5篇
  1997年   1篇
  1996年   1篇
  1994年   2篇
  1992年   1篇
  1990年   1篇
  1989年   1篇
  1988年   1篇
  1987年   2篇
排序方式: 共有1423条查询结果,搜索用时 15 毫秒
11.
Purpose: The optimal surgical treatment of displaced type B and C fractures of the proximal humerus in the elderly remains controversial. Good clinical results have been reported by plating these fractures as well as a high rate of complications. Our retrospective study aims to evaluate clinical recovery and complications using the S3 locking plate in elderly patients.Methods: Fifty-one patients older than 65 years of age, with a complex proximal humeral fracture type B or C (AO classification system), were included. Patients have been followed up for a minimum of 12months. We assessed callus formation, radiological results, clinical outcome (according to the Constant Shoulder Score System) and complications. Any difference in the clinical recovery among the 2 types of fracture pattern (B and C) was investigated.Results: The mean time of fracture healing was 12.4 weeks. The mean Constant score at 3, 6 and 12months was 68, 73 and 75 respectively. No statistically significant difference in the clinical outcome was observed between the B and C fracture patterns (p > 0.05). We noticed an overall of 5 complications (9.8%). There was no need to revision any of the implants.Conclusion: Anatomic reduction and proper plate positioning are essential for minimizing implantrelated complications. In our experience the S3 angular stability system offers a proper osteosyntesis and a good clinical recovery with a low rate of complications.  相似文献   
12.
   Introduction    Case report
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号