This study of a series of 40 mildly head injured (concussed) patients suggests that different physiologic pathways underlying the tests done in a six-part resting EEG, and for the 11 evoked electrical potential shifts occurring in the cerebral terrain, are testable. Further work seems likely in order to ascertain which clinical signs and symptoms may be related to specific individual types of recorded electronic brain imaging (EBI) abnormality. Which of the 11 parameters studied, EEG, VER, AER, and SER, would be more or less likely to be abnormal in their individual patterns (as being deviant from normal controls) also remains to be defined. The relationship of these neurophysiologic abnormalities to certain postconcussive symptoms, i.e., headache, dizziness, blurred vision, etc., at this point in time remains to be evaluated more precisely. The authors suggest that further research is necessary in evaluating the clinical use of somatosensory evoked responses as an additional parameter in electronic brain imaging (EBI) technology. 相似文献
Background: Measuring the work of breathing of patients undergoing spontaneous assisted ventilation can be useful to monitor and titrate ventilatory support. The aim of this study was to obtain measurements of the pressure generated by the respiratory muscles (PMUSC) and the derived pressure-time product (PTP; a good indicator of the metabolic work of breathing), performing the rapid interrupter technique with a commercial ventilator.
Methods: A Draeger Evita 4 ventilator (Draeger Medical, Lubeck, Germany) was controlled by a personal computer to rapidly interrupt the airway flow at different times and volumes of the respiratory cycle during pressure-support ventilation. From the airway pressure tracing after the occlusion, the authors estimated the alveolar pressure and PMUSC; the integration of PMUSC values over the inspiratory time yields the measurement of PTP. Esophageal pressure measurements were used as a reference. After a bench study of the valves' performance, the authors performed 11 measurement sequences in eight patients.
Results: The closure times for the inspiratory and expiratory valves were 74 +/- 10 and 61 +/- 13 ms, respectively. The interrupter technique provided a reliable estimate of PMUSC (PMUSC, occl = 1.00 [middle dot] PMUSC, pes + 0.19; r = 0.88; 95% confidence interval for agreement, +5.49/-5.32 cm H2O). PTPoccl tightly correlated with PTPpes (PTPoccl = 0.95 [middle dot] PTPpes + 0.13; r = 0.96; 95% confidence interval, 1.94/-1.61 cm H2O [middle dot] s). 相似文献
This article presents the revision process, major innovations, and clinimetric testing program for the Movement Disorder Society (MDS)-sponsored revision of the Unified Parkinson's Disease Rating Scale (UPDRS), known as the MDS-UPDRS. The UPDRS is the most widely used scale for the clinical study of Parkinson's disease (PD). The MDS previously organized a critique of the UPDRS, which cited many strengths, but recommended revision of the scale to accommodate new advances and to resolve problematic areas. An MDS-UPDRS committee prepared the revision using the recommendations of the published critique of the scale. Subcommittees developed new material that was reviewed by the entire committee. A 1-day face-to-face committee meeting was organized to resolve areas of debate and to arrive at a working draft ready for clinimetric testing. The MDS-UPDRS retains the UPDRS structure of four parts with a total summed score, but the parts have been modified to provide a section that integrates nonmotor elements of PD: I, Nonmotor Experiences of Daily Living; II, Motor Experiences of Daily Living; III, Motor Examination; and IV, Motor Complications. All items have five response options with uniform anchors of 0 = normal, 1 = slight, 2 = mild, 3 = moderate, and 4 = severe. Several questions in Part I and all of Part II are written as a patient/caregiver questionnaire, so that the total rater time should remain approximately 30 minutes. Detailed instructions for testing and data acquisition accompany the MDS-UPDRS in order to increase uniform usage. Multiple language editions are planned. A three-part clinimetric program will provide testing of reliability, validity, and responsiveness to interventions. Although the MDS-UPDRS will not be published until it has successfully passed clinimetric testing, explanation of the process, key changes, and clinimetric programs allow clinicians and researchers to understand and participate in the revision process. 相似文献
Background: Field studies of the duration of fixation during daytime driving find that it is about 0.2 seconds on average. Thus, the time available to read traffic signs is often limited. There are other circumstances where time to read alphanumeric messages is limited. Data relating time of observation are needed for purposes of ergonomic design as the data available in the literature are limited and uncertain. Method: Visual acuity was measured using Landolt rings in negative contrast, which were presented on a computer screen with a background luminance of 32 cd/m2 for durations that varied between two and 0.02 seconds at three different contrasts. Resulte: Visual acuity depends on the log of the light dose reduced by a factor that may be related to absorption of the light by the eye media. For young observers, it was found that: VA = 0.57 (log C t) + 1.705, where C is the contrast and is expressed as δL/L, where δL is the difference between target and background luminances in cd/m2 and t is the observation time in seconds. Conclusion: This formula or the functions fitted to the data obtained can be used to calculate the increase in target size needed to allow for short observation times. 相似文献
A numerical simulation tool was developed to calculate the echo amplitudes of J-coupled resonances within a series of radiofrequency (RF) refocused echoes. The signal modulation due to J-coupling in rapid acquisition with relaxation enhancement (RARE) is suppressed only when the inverse of the pulse interval (tau) is large compared to both the chemical shift (CS) difference (Deltadelta) of the coupled spins and the coupling constant. In contrast, the echo amplitudes in ultrafast low-flip-angle RARE (U-FLARE) oscillate around a quasi-steady-state value that is greater than zero (neglecting relaxation and diffusion) even when Deltadelta > 1/tau. The flip-angle distribution over the measured slice caused by the use of Gaussian-shape slice-selective refocusing pulses further reduces the echo oscillations. When the pulse interval falls short of the fast pulse rate regime, spectroscopic U-FLARE provides an improved spatial impulse response in the phase-encoding (PE) direction compared to spectroscopic RARE. 相似文献
A new method for the selective spin labeling of left- or right-sided supplying arteries of the brain without the need for additional RF coils is demonstrated. A clinical 1.5 T scanner was used. The spatial selectivity of the labeling process is based on the limited coverage of the excitation field of a standard send/receive head coil together with an oblique positioning of the labeling plane. A computer simulation was used to optimize key labeling parameters under the condition of laminar flow. The validity of the computer model results was confirmed by MRI measurements with a flow model. For human studies, a double-inversion continuous arterial spin labeling (CASL) sequence was modified to allow for arbitrary positioning of the labeling plane. The obtained perfusion-weighted images showed a clear delineation of the perfusion territories of the selected arteries in the anterior circulation of the brain and good gray/white matter contrast. 相似文献
(18)F-FDG PET is the most accurate noninvasive modality for staging mediastinal lymph nodes in lung cancer. Besides using visual image interpretation, some institutions use standardized uptake value (SUV) measurements in lymph nodes. Mostly, an SUV of 2.5 is used as the cutoff, but this choice was never deduced from respective studies. Receiver operating characteristic (ROC) analyses demonstrated that SUV thresholds of more than 4 resulted in the highest accuracy. But these high cutoffs imply high false-negative rates (FNRs). The aim of our evaluation was to determine an optimal SUV threshold and to compare its diagnostic performance with the results of visual interpretation. METHODS: This retrospective study included 95 patients with suspected lung cancer who underwent mediastinoscopy/mediastinal lymphadenectomy after (18)F-FDG PET (90-150 min after 250 MBq of (18)F-FDG). Maximum SUV was measured in 371 lymph node regions biopsied afterward and visually interpreted using a 6-level score (- - - through + + +). Diagnostic performance was assessed by ROC analysis. FNR and false-positive rate (FPR), the sum of both error rates (FNR + FPR), and diagnostic accuracy were plotted against a hypothetical SUV threshold to determine the optimum SUV threshold. RESULTS: SUVs in metastatic lymph nodes were higher (mean +/- SD, 7.1 +/- 4.5; range, 1.4-26.9; n = 70) than in tumor-free lymph node stations (2.4 +/- 1.7; range, 0.6-14.9; n = 301; P < 0.01). Inflammatory lymph nodes exhibited slightly increased SUVs (2.7 +/- 2.0; range, 0.8-14.9; n = 146). The plot of error rates featured a minimum of the sum FNR + FPR for an SUV of 2.5. With increasing SUV threshold, the FPR decreased most prominently up to that value whereas a continuous rise of FNR was noticed. Highest diagnostic accuracy was achieved with an SUV of 4.5. The areas under the ROC curves demonstrated that visual interpretation tends to be more accurate than SUV quantification (visual, 0.930 +/- 0.022; SUV, 0.899 +/- 0.025; P = 0.241). Using an SUV of 2.5 as the threshold, the resulting sensitivity, specificity, and negative predictive value were 89%, 84%, and 96%, respectively. CONCLUSION: For mediastinal staging, the choice of an SUV of 2.5 as the threshold is justified because FNR + FPR is minimized. The resulting high negative predictive value of 96% allows the omission of mediastinoscopy in patients with negative mediastinal findings on (18)F-FDG PET images. For the experienced observer, visual analysis should be relied on primarily, with calculation of the SUV used, at most, as a secondary aid. For the less experienced observer, the SUV may be of greater value. 相似文献