A disconcertingly wide variation exists in the literature as to the accuracy of duplex Doppler sonography in the detection of acute renal transplant rejection. Sensitivities range from 9% to 76%. In an attempt to explain the disparity of results, we undertook a double-blind prospective study of the accuracy of duplex Doppler ultrasound in the detection of acute rejection in renal transplants. We scanned 49 consecutive patients with a total of 65 biopsies; 46 biopsies in 33 consecutive patients were included in our study. In our population, the prevalence of acute rejection was 61% (28/46). Using a resistive index (RI) cutoff of greater than 0.90 based on the main renal artery flow pattern, the sensitivity of our test was 43%, with a 67% specificity. The positive predictive value was 67%. Our results are contrasted and compared with the published data from other groups in a critical survey of the literature. We conclude that duplex Doppler sonography alone is inadequate to evaluate acute rejection in renal transplants. 相似文献
The retention of the post to the root of an endodontically treated tooth is critical for a successful restoration. Modification of the post length to accommodate a specific clinical situation is common. This study compared the retention of No. 1 and No. 2 Flexi-Post restorations shortened apically from 1 to 5 mm with that reported for full-length control No. 1 and No. 2 Flexi-Post dowels. The experimental material was divided into 10 groups with 10 samples in each group. Retentive values were recorded in pounds with a universal testing machine. Analysis of variance with a Tukey-Student range, multiple-comparison test showed no statistical differences from apical reductions of 1, 2, 3, and 5 mm including the full-length control Flexi-Post No. 1 system. With 4 mm of apical shortening statistically greater retention was recorded. No statistical differences resulted with apical reductions of 1 to 4 mm or with the full-length control Flexi-Post No. 2 system, but 5 mm of apical shortening caused significantly less retention. 相似文献
Frequent and recurrent ventricular premature beats (VPB's) are considered to be associated with a higher risk of sudden cardiac death, particularly for survivors of myocardial infarction (MI). The distribution of VPB's has a large probability mass at zero, and a very heavy right hand tail. In this research, we fitted a model to VPB for patients for which VPB was present. The model was fitted on the basis of a relatively large data set on MI survivors in Israel. The model was fitted by a method which is based on the generalized linear model. This method, which was introduced by Zeger and Liang, is designed for longitudinal data and uses the quasi-likelihood concept. No specific assumptions are required on the shape of the distribution of the dependent variable. The results indicate that the model fits the data quite well but underestimates the very extreme high values. This research demonstrates the applicability of generalized linear models for longitudinal non-Gaussian data. Such data often arise in medical studies. The study also points out the distributional properties of VPB counts. In particular, it shows their associations with simple clinical and epidemiological variables, and with certain time periods during the day. 相似文献
Study Objective: To test the hypothesis that slow administration of local anesthetic into the epidural space by gravity flow reduces the incidence of signs and symptoms of unintended injection.
Design: Prospective, randomized study.
Setting: Teaching hospital.
Patients: 600 ASA physical status I and II parturients scheduled for labor and delivery or elective cesarean section.
Interventions: After identification of the epidural space with pulsations of an air-fluid column, parturients for vaginal delivery (n = 380) were randomized to receive a test dose of 3 ml 3% 2-chloroprocaine with epinephrine 20 μg, two doses of 7 ml bupivacaine 0.03 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow (Group 1) given over 30 seconds or by bolus injection (Group 2) given over 5 seconds through the epidural needle; parturients for Cesarean delivery (n = 220) were randomized to receive a test dose and two doses of 6 ml lidocaine 2 % with sufentanil 1 μg/ml and epinephrine 2 μg/ml by either gravity flow or by bolus injection through the epidural needle. Changes in maternal heart rate (HR) and blood pressure, signs of intravascular injection, and adverse effects of epidural bupivacaine-sufentanil were recorded after each dose.
Measurements and Main Results: Gravity flow administration (Group 1) was associated with a smaller increase in mean maternal HR (p < 0.001), less hypotension (p < 0.01), sedation (p < 0.01), nausea (p = 0.01), and segmental spread (p < 0.0001) than were corresponding doses given by traditional bolus injection (Group 1) for vaginal or Cesarean deliveries. The incidence of systemic toxicity was zero of 300 (0%) with gravity flow and 4 of 300 (1.3%) by bolus injection, p = 0.12, Fisher's exact test. No patient in either group had an accidental intrathecal injection.
Conclusion: Gravity flow administration of local anesthetic-opioid solution during epidural block for obstetrics was associated with fewer signs of systemic drug absorption and cardiovascular perturbations than was the traditional bolus injection. This study supports the current opinion that slow administration of local anesthetic during epidural black contributes to fewer adverse events. 相似文献
Single breath-holding gradient echo techniques fast imaging with steady-state free precession (FISP) and fast low angle shot (FLASH) images were evaluated in the study of the abdomen in 16 patients (13 liver, two kidney, and one pancreas examinations). Gradient echo images were compared retrospectively with conventional spin echo images for image quality (depiction of pathology and representation of anatomic detail), and contrast characteristics were evaluated. All lesions were shown on gradient echo images, and in three of 16 cases gradient echo images were more diagnostic than spin echo images. On both FISP and FLASH images, most hepatic metastases were hyperintense relative to normal liver. The predicted flip angles for maximal contrast for the liver were modeled from signal intensity equations for FISP and FLASH and yielded predicted flip angles of approximately 40-55 degrees for FISP and 15-25 degrees for FLASH. Peak signal-to-noise ratio in liver of normal volunteers occurred at approximately 30 degrees for both FISP and FLASH. Single breath-holding gradient echo images are useful in the evaluation of abdominal structures and this study provides a framework for future work. 相似文献
Summary: We have developed a novel experimental model of cancer immunity in the frog, Xenopus , which may provide a useful alternative to murine tumor models and a way to assess whether the control of tumor development is a fundamental function of the immune system of vertebrates. In Xenoptis , tumor immunity can be studied in two developmentally distinct immune systems. The larval immune system reflects characteristics of an ancestral system that appears to function without classical MHC class I antigen presentation and an efficient effector mechanism. The adult system appears more highly evolved in that it is remarkably similar to that of mammals and is able to generate a potent antitumor response. This amphibian model also provides a unique system with which to investigate a postulated role of heat shock proteins as components of an ancestral system of antigen presentation and/or immune surveillance that predates the antigen presentation pathway that exclusively involves MHC molecules. 相似文献
To investigate the stimuli required for the induction of nitric oxide synthase (NOS) in sepsis, we have analyzed the levels of this enzyme in the livers of mice infected with a 90% lethal dose of Escherichia coli in a model of gram-negative sepsis. Hepatic NOS levels are markedly induced in this model, with peak values occurring 12 to 22 h following infection. Treatment with TN3-19.12, a neutralizing monoclonal antibody to tumor necrosis factor alpha (TNF-alpha), resulted in complete protection from death in this model of sepsis but had no significant effect on the level of induction of hepatic NOS. Treatment with H22, a monoclonal antibody to gamma interferon (IFN-gamma), also gave significant protection against death and, in addition, did lead to a decrease in the level of induction of the hepatic NOS. Treatment of mice with pure TNF-alpha (0.2 microgram), IFN-gamma (2,000 U), or a combination of the two did not induce the hepatic NOS, but treatment with the combination led to significant mortality (probability of survival at 22 h, 0.32). Thus, the level of induction of NOS within the liver either in sepsis or by the coadministration of TNF-alpha and IFN-gamma does not correlate with death. 相似文献
Acquired cystic disease has been documented to complicate most forms of chronic renal damage; it has only infrequently been described in transplanted kidneys. Five patients with noncystic ESRD and chronically rejected transplants in which acquired cystic disease arose are reported. The diagnosis of acquired cystic disease was established in examination of transplant nephrectomies from four patients and a core biopsy from the fifth. The allografts were in place from 44 to 80 months; three patients were treated with hemodialysis before the diagnosis of acquired cystic disease, whereas two received peritoneal dialysis. Three of the four patients evaluated had cysts in the native kidneys. Although papillary hyperplasia of lining epithelium was evident in four specimens, only one kidney was the site of neoplasms in the form of multiple small tubular adenomas. No malignant neoplasms were noted in this study or in the few similar previous ones; however, it is possible that chronically rejected transplanted kidneys may harbor neoplasms with the same malignant potential as those in acquired cystic disease in native kidneys. 相似文献