全文获取类型
收费全文 | 162篇 |
免费 | 10篇 |
国内免费 | 1篇 |
专业分类
耳鼻咽喉 | 2篇 |
基础医学 | 26篇 |
口腔科学 | 3篇 |
临床医学 | 13篇 |
内科学 | 57篇 |
皮肤病学 | 1篇 |
神经病学 | 8篇 |
特种医学 | 3篇 |
外科学 | 26篇 |
综合类 | 1篇 |
预防医学 | 16篇 |
药学 | 10篇 |
肿瘤学 | 7篇 |
出版年
2023年 | 2篇 |
2022年 | 5篇 |
2021年 | 24篇 |
2020年 | 3篇 |
2019年 | 20篇 |
2018年 | 15篇 |
2017年 | 9篇 |
2016年 | 6篇 |
2015年 | 6篇 |
2014年 | 8篇 |
2013年 | 2篇 |
2012年 | 10篇 |
2011年 | 14篇 |
2010年 | 6篇 |
2009年 | 6篇 |
2008年 | 7篇 |
2007年 | 6篇 |
2006年 | 6篇 |
2005年 | 7篇 |
2004年 | 5篇 |
2003年 | 3篇 |
2002年 | 1篇 |
2001年 | 1篇 |
1997年 | 1篇 |
排序方式: 共有173条查询结果,搜索用时 312 毫秒
111.
Chemotherapy and radiotherapy are the most frequent treatment for patients suffering from malignant progression of cancer. Even though new treatments are now being implemented, administration of these chemotherapeutic agents remains as the first line option in many tumor types. However, the secondary effects of these compounds represent one of the main reasons cancer patients lose life quality during disease progression. Recent data suggests that Ocoxin, a plant extract and natural compound based nutritional complement rich in antioxidants and anti-inflammatory mediators exerts a positive effect in patients receiving chemotherapy and radiotherapy. This mixture attenuates the chemotherapy and radiotherapy-related side effects such as radiation-induced skin burns and mucositis, chemotherapy-related diarrhea, hepatic toxicity and blood-infection. Moreover, it has been proven to be effective as anticancer agent in different tumor models both in vitro and in vivo, potentiating the cytotoxic effect of several chemotherapy compounds such as Lapatinib, Gemcitabine, Paclitaxel, Sorafenib and Irinotecan. The aim of this review is to put some light on the potential of this nutritional mixture as an anticancer agent and complement for the standard chemotherapy routine. 相似文献
112.
Jung-Hyun Kim Jeffery B. Powell Raymond J. Roberge Angie Shepherd Aitor Coca 《Journal of occupational and environmental hygiene》2014,11(4):259-267
The purpose of this study was to evaluate the predictive capability of fabric Total Heat Loss (THL) values on thermal stress that Personal Protective Equipment (PPE) ensemble wearers may encounter while performing work. A series of three tests, consisting of the Sweating Hot Plate (SHP) test on two sample fabrics and the Sweating Thermal Manikin (STM) and human performance tests on two single-layer encapsulating ensembles (fabric/ensemble A = low THL and B = high THL), was conducted to compare THL values between SHP and STM methods along with human thermophysiological responses to wearing the ensembles. In human testing, ten male subjects performed a treadmill exercise at 4.8 km and 3% incline for 60 min in two environmental conditions (mild = 22°C, 50% relative humidity (RH) and hot/humid = 35°C, 65% RH). The thermal and evaporative resistances were significantly higher on a fabric level as measured in the SHP test than on the ensemble level as measured in the STM test. Consequently the THL values were also significantly different for both fabric types (SHP vs. STM: 191.3 vs. 81.5 W/m2 in fabric/ensemble A, and 909.3 vs. 149.9 W/m2 in fabric/ensemble B (p < 0.001). Body temperature and heart rate response between ensembles A and B were consistently different in both environmental conditions (p < 0.001), which is attributed to significantly higher sweat evaporation in ensemble B than in A (p < 0.05), despite a greater sweat production in ensemble A (p < 0.001) in both environmental conditions. Further, elevation of microclimate temperature (p < 0.001) and humidity (p < 0.01) was significantly greater in ensemble A than in B. It was concluded that: (1) SHP test determined THL values are significantly different from the actual THL potential of the PPE ensemble tested on STM, (2) physiological benefits from wearing a more breathable PPE ensemble may not be feasible with incremental THL values (SHP test) less than approximately 150–200 W·m2, and (3) the effects of thermal environments on a level of heat stress in PPE ensemble wearers are greater than ensemble thermal characteristics. 相似文献
113.
114.
Javier Garaizar Mikel Latorre Nuria López-Molina Idoia Laconcha Leire Alberdi Aitor Rementeria Ana Audicana Rosario Uliarte Ramón Cisterna 《Clinical microbiology and infection》1997,3(2):222-228
Objective: To assess restriction endonuclease analysis (REA) of chromosomal DNA using Sal l enzyme, low-concentration (0.4%) agarose gels and digitalized data management of the REA patterns obtained for the typing of clinical Pseudomonas aeruginosa isolates.
Method: A group of 67 clinical unrelated isolates from 10 Spanish hospitals was used to study the discriminatory power, reproducibility and typeability of REA typing.
Results: A Sal l REA pattern consisted of a variety (1–10) of restriction bands in the range between 12.2 and 48.5 kb and an unresolvable smear of low-molecular-weight bands. Forty different Sal l REA patterns with an index of discrimination of 0.979 were obtained. Low tupeability (91.04%) was the major limitation of REA typing. Analysis of blinded subcultures of eight Pseudomonas aeruguinosa strains showed the reproducibility of REA typing to be 87.5%. Combined phenotypic typing (O-serotyping and phage typing) performed on the same group of strains showed comparable discrimination but much lower reproducibility. Isolates selected from five clusters of nosocomial infections in hospitals in the UK were typed by REA typing, and the results show high agreement when compared with conventional phenotypic typing methods in distinguishing between strains.
Conclusions: These data underline the usefulness of REA typing enhanced with digitalized data management for the epidemiologic subtyping of clinical Pseudomonas aeruginosa isolates. 相似文献
Method: A group of 67 clinical unrelated isolates from 10 Spanish hospitals was used to study the discriminatory power, reproducibility and typeability of REA typing.
Results: A Sal l REA pattern consisted of a variety (1–10) of restriction bands in the range between 12.2 and 48.5 kb and an unresolvable smear of low-molecular-weight bands. Forty different Sal l REA patterns with an index of discrimination of 0.979 were obtained. Low tupeability (91.04%) was the major limitation of REA typing. Analysis of blinded subcultures of eight Pseudomonas aeruguinosa strains showed the reproducibility of REA typing to be 87.5%. Combined phenotypic typing (O-serotyping and phage typing) performed on the same group of strains showed comparable discrimination but much lower reproducibility. Isolates selected from five clusters of nosocomial infections in hospitals in the UK were typed by REA typing, and the results show high agreement when compared with conventional phenotypic typing methods in distinguishing between strains.
Conclusions: These data underline the usefulness of REA typing enhanced with digitalized data management for the epidemiologic subtyping of clinical Pseudomonas aeruginosa isolates. 相似文献
115.
A new pulse program development, a chemical shift selective filtration clean in-phase HSQMBC (CSSF-CLIP-HSQMBC), is presented for the user-friendly measurement of long-range heteronuclear coupling constants in severely crowded spectral regions. The introduction of the chemical shift selective filter makes the experiment extremely efficient at resolving overlapped multiplets and produces a clean selective CLIP-HSQMBC spectrum, in which the desired coupling constants can easily be measured as an extra proton–carbon splitting in f2. The pulse sequence is also provided as a real-time homonuclear decoupled version in which the heteronuclear coupling constant can be directly measured as the peak splitting in f2. The same principle is readily applicable to IPAP and AP versions of the same sequence as well as the optional TOCSY transfer, or in principle to any other selective heteronuclear experiment that relies on a clean 1H multiplet.A new pulse program development, a chemical shift selective filtration clean in-phase HSQMBC (CSSF-CLIP-HSQMBC), is presented for the user-friendly measurement of long-range heteronuclear coupling constants in severely crowded spectral regions. 相似文献
116.
There is growing evidence of a direct influence of vasculature on the development of neurons in the brain. The development of the cranial vasculature has been well described in zebrafish but its anatomical relationship with the adjacent developing sensory ganglia has not been addressed. Here, by 3D imaging of fluorescently labelled blood vessels and sensory ganglia, we describe for the first time the spatial organization of the cranial vasculature in relation to the cranial ganglia during zebrafish development. We show that from 24 h post‐fertilization (hpf) onwards, the statoacoustic ganglion (SAG) develops in direct contact with two main blood vessels, the primordial hindbrain channel and the lateral dorsal aortae (LDA). At 48 hpf, the LDA is displaced medially, losing direct contact with the SAG. The relationship of the other cranial ganglia with the vasculature is evident for the medial lateral line ganglion and for the vagal ganglia that grow along the primary head sinus (PHS). We also observed that the innervation of the anterior macula runs over the PHS vessel. Our spatiotemporal anatomical map of the cranial ganglia and the head vasculature indicates physical interactions between both systems and suggests a possible functional interaction during development. 相似文献
117.
118.
119.
Kim JH Coca A Williams WJ Roberge RJ 《Journal of occupational and environmental hygiene》2011,8(7):409-416
This study investigated the effects of body cooling using liquid cooling garments (LCG) on performance time (PT) and recovery in individuals wearing a fully equipped prototype firefighter ensemble (PFE) incorporating a self-contained breathing apparatus (SCBA). Six healthy male participants (three firefighters and three non-firefighters) completed six experimental sessions in an environmental chamber (35°C, 50% relative humidity), consisting of three stages of 15 min exercise at 75% VO2max, and 10 min rest following each exercise stage. During each session, one of the following six conditions was administered in a randomized order: control (no cooling, CON); air ventilation of exhaust SCBA gases rerouted into the PFE (AV); top cooling garment (TCG); TCG combined with AV (TCG+AV); a shortened whole body cooling garment (SCG), and SCG combined with AV (SCG+AV). Results showed that total PT completed was longer under SCG and SCG+AV compared with CON, AV, TCG, and TCG+AV (p<0.01). Magnitude of core temperature (Tc) elevation was significantly decreased when SCG was utilized (p<0.01), and heart rate recovery rate (10 min) was enhanced under SCG, SCG+AV, TCG, and TCG+AV compared with CON (p<0.05). Estimated Esw rate (kg·h(-1)) was the greatest in CON, 1.62 (0.37), and the least in SCG+AV 0.98 (0.44): (descending order: CON>AV>TCG=TCG+AV>SCG>SCG+AV) without a statistical difference between the conditions (p<0.05). Results of the present study suggest that the application of LCG underneath the PFE significantly improves the recovery during a short period of rest and prolongs performance time in subsequent bouts of exercise. LCG also appears to be an effective method for body cooling that promotes heat dissipation during uncompensable heat stress. 相似文献
120.
Raymond J. ROBERGE Aitor COCA W. Jon WILLIAMS Andrew J. PALMIERO Jeffrey B. POWELL 《Respirology (Carlton, Vic.)》2010,15(3):516-521
Background and objective: Filtering facepiece respirators (‘N95 Masks’) may be in short supply during large‐scale infectious outbreaks. Suggestions have been made to extend their useful life by using a surgical mask as an outer barrier, but the physiological impact of this added barrier upon the wearer has not been studied. Methods: A surgical mask was worn over an N95 filtering facepiece respirator by 10 healthcare workers for 1 h at each of two work rates. Heart rate, respiratory rate, tidal volume, minute volume, oxygen saturation, transcutaneous carbon dioxide levels and respirator dead space gases were monitored and compared with controls (N95 filtering facepiece respirator without a surgical mask). Subjective perceptions of exertion and comfort were assessed by numerical rating scales. Results: There were no significant differences in physiological variables between those who used surgical masks and controls. Surgical masks decreased dead space oxygen concentrations of the filtering facepiece respirators at the lesser work rate (P = 0.03) and for filtering facepiece respirators with an exhalation valve at the higher work rate (P = 0.003). Respirator dead space oxygen and carbon dioxide levels were not harmonious with Occupational Safety and Health Administration workplace ambient atmosphere standards. Exertion and comfort scores were not significantly impacted by the surgical mask. Conclusions: Use of a surgical mask as an outer barrier over N95 filtering facepiece respirators does not significantly impact the physiological burden or perceptions of comfort and exertion by the wearer over that experienced without use of a surgical mask. 相似文献