Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
Abstract: Background: Fetal pulse oximetry improves the assessment of fetal well‐being during labor. The objective of this study was to evaluate women's satisfaction with their experience with this additional technology. Methods: We surveyed women participating in the FOREMOST trial, a randomized controlled trial comparing the addition of fetal pulse oximetry (FPO) to conventional cardiotocograph (CTG) monitoring (intervention group), versus CTG‐only (control group), in the presence of nonreassuring fetal status during labor. Our survey evaluated 3 aspects of women's experience: labor, fetal monitoring, and participation in the research. The survey was administered within a few days of giving birth and repeated 3 months later. Results: No differences were found between the intervention and control groups for women's evaluations of their labor, fetal monitoring, research, or overall experiences when surveyed on both occasions. Within each study group, a small but statistically significant decline occurred in women's scores for their experience of labor and overall experience from the initial survey close to the time of giving birth, to 3 months later. The magnitude of differences in responses over time was similar for the both groups. Women were more satisfied after a spontaneous or assisted vaginal birth than after cesarean section. Length of time the research midwife was present had a significant positive effect on women's ratings of their experience several days after giving birth (p = 0.006), but no effect at 3 months. Conclusions: The addition of fetal pulse oximetry for the assessment of fetal well‐being during labor did not affect childbearing women's perceptions of fetal monitoring or their labor. Women evaluated their experience in the research process positively overall. Small changes occurred in women's perception of their satisfaction over time. (BIRTH 33:2 June 2006)相似文献
OBJECTIVE: To assess the effect of glucose control on the rate of growth of fetuses in women with pregestational diabetes mellitus (Types 1 and 2). METHODS: All pregestational diabetic women booked at Mater Mothers' Hospital, Brisbane, Australia, between 1 January 1994 and 31 December 2002, were included. Pregnancies with congenital fetal anomalies, multiple pregnancies, and pregnancies terminated prior to 20 weeks' gestation were excluded. Dating scans were performed before 14 weeks' gestation and serial scans were performed at 18, 24, 28, 32 and 36 weeks. Fetal parameters, including biparietal diameter, femur length and abdominal circumference, were recorded. The daily growth rates for biparietal diameter, femur length, and fetal abdominal area were calculated and compared with those in a low-risk (non-diabetic) population. The growth rates in fetuses of women with satisfactory diabetic control (HbA1c < 6.5%) and unsatisfactory control (HbA1c > or = 6.5%) in the three trimesters were compared. RESULTS: A total of 174 diabetic pregnancies were included and a total of 997 ultrasound scans were performed. The growth rates for fetuses of mothers with diabetes mellitus were significantly higher than for those in the low-risk population. The z-scores for biparietal diameter, femur length, and fetal abdominal area were 0.18, 0.59 and 1.44, respectively. Fetuses of diabetic mothers with high HbA1c in the first trimester had significantly greater fetal abdominal area growth rate than those with normal HbA1c (fetal abdominal area z-score of 1.7 vs. 0.75, P = 0.009). Although the fetal abdominal area z-scores in fetuses of diabetic mothers with high HbA1c in the second or third trimesters were also higher than those with normal HbA1c levels, the differences did not reach statistical significance. Maternal obesity did not influence the fetal growth rate. CONCLUSION: The rate of growth of fetuses of diabetic mothers differs from that of the normal population. Growth acceleration persists until the late third trimester. Moreover, periconceptional glucose control appears to have a significant effect on accelerated growth of the fetal abdominal area. 相似文献
Background/purpose: Vitiligo and nevus depigmentosus (ND) present similar hypopigmented macules with significantly different prognoses. Although the distinction between the two diseases is important, differential diagnosis relies on medical history and physical examination, which is far from decisive in some cases. The Mexameter® is an objective skin color-measuring device, and has been reported to provide a reproducible and sensitive means of quantifying small skin color differences. In this study, we investigated the usefulness of a Mexameter® for discriminating these diseases. Methods: A selection of 202 hypopigmented skin lesions (182 from vitiligo and 20 from ND) were the objects of this study. Using a Mexameter, MIs were obtained from lesions and symmetrically located control skin. RMIs, ratios of the MIs of lesional skins to control skins, were calculated. Results: The mean MIs and RMIs were significantly different for vitiligo and ND. The mean RMI of ND lesions was 74±13, which was significantly higher than that of vitiligo lesions (50±24). No ND lesion had an RMI of <50%. Conclusion: This study shows that the Mexameter®, an objective pigment-measuring device, can be used to achieve a more accurate diagnosis of hypopigmentary disorders, and that the relative melanin index (RMI), which represents the relative pigment levels, might be a more effective parameter than the melanin index (MI) itself for comparing pigmentation differences. 相似文献
TM4 is a lytic mycobacteriophage which infects mycobacteria of clinical importance. A luciferase reporter phage, phAE40, has been constructed from TM4 and was previously shown to be useful for the rapid detection and drug susceptibility testing of Mycobacterium tuberculosis. However, the lytic nature of the phage results in a loss of detectable light output and limits the sensitivity of detection. We describe several strategies aimed at improving the luciferase activity generated by TM4 luciferase phages, including (i) varying the position of the luciferase gene in the phage genome, (ii) isolating host-range mutants of the phage, and (iii) introducing temperature-sensitive mutations in the phage such that it will not replicate at the infecting temperature. Several new phages generated by these methods show increased intensity of luciferase production compared to the first-generation reporter phage phAE40, and one phage, phAE88, also demonstrates an enhanced duration of luciferase activity. This has allowed the detection of as few as 120 BCG cells and the determination of drug susceptibilities of M. tuberculosis in as little as 1 day. 相似文献