首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   86篇
  免费   1篇
儿科学   2篇
妇产科学   2篇
基础医学   5篇
口腔科学   1篇
临床医学   43篇
内科学   19篇
皮肤病学   3篇
神经病学   2篇
外科学   8篇
预防医学   1篇
眼科学   1篇
  2016年   1篇
  2010年   1篇
  2009年   10篇
  2007年   2篇
  2006年   4篇
  2005年   2篇
  2004年   1篇
  2003年   5篇
  2001年   3篇
  2000年   4篇
  1999年   1篇
  1998年   12篇
  1997年   4篇
  1996年   10篇
  1995年   4篇
  1994年   3篇
  1993年   5篇
  1992年   2篇
  1991年   4篇
  1990年   3篇
  1989年   1篇
  1986年   1篇
  1985年   2篇
  1980年   1篇
  1956年   1篇
排序方式: 共有87条查询结果,搜索用时 15 毫秒
41.
42.
43.
44.
BACKGROUND: The aim of the present study was to examine whether increased water load intake prior to ultrasound examination of the lower urinary tract, affects the measurement of postvoid residual urine volume. PATIENTS AND METHODS: Ninety four male patients with postvoid residual volumes after increased water load diuresis of more than 100 mL (PVR1) were included in the present study. All patients underwent a second PVR measurement by an urologist with a portable transabdominal bladder ultrasound scan without having received an increased water load (PVR2). A comparison of the measurements was performed and the PVR values were also correlated with other parameters, such as age, International Prostate Symptom Score, prostate volume and serum prostate-specific antigen (PSA) values. RESULTS: Postvoid residual urine volume after increased water load diuresis (PVR1) differed from that recorded after normal bladder filling and voiding at first desire (PVR2), with the former being larger than the later in every patient (P < 0.001). The PVR values, PVR1 and PVR2, were independent to patient age, symptom score prostate volume and PSA value. CONCLUSIONS: Measurement of postvoid residual volume in a relaxed patient, who voids at first desire, represents everyday life and should be the correct method of testing.  相似文献   
45.
Introduction: Spatial characteristics of atrial fibrillatory waves have been extracted by using a vectorcardiogram (VCG) during atrial fibrillation (AF). However, the VCG is usually not recorded in clinical practice and atrial loops are derived from the 12-lead electrocardiogram (ECG). We evaluated the suitability of the reconstruction of orthogonal leads from the 12-lead ECG for fibrillatory waves in AF.
Methods: We used the Physikalisch-Technische Bundesanstalt diagnostic ECG database, which contains 15 simultaneously recorded signals (12-lead ECG and three Frank orthogonal leads) of 13 patients during AF. Frank leads were derived from the 12-lead ECG by using Dower's inverse transform. Derived leads were then compared to true Frank leads in terms of the relative error achieved. We calculated the orientation of AF loops of both recorded orthogonal leads and derived leads and measured the difference in estimated orientation. Also, we investigated the relationship of errors in derivation with fibrillatory wave amplitude, frequency, wave residuum, and fit to a plane of the AF loops.
Results: Errors in derivation of AF loops were 68 ± 31% and errors in the estimation of orientation were 35.85 ± 20.43°. We did not find any correlation among these errors and amplitude, frequency, or other parameters.
Conclusions: In conclusion, Dower's inverse transform should not be used for the derivation of orthogonal leads from the 12-lead ECG for the analysis of fibrillatory wave loops in AF. Spatial parameters obtained after this derivation may differ from those obtained from recorded orthogonal leads.  相似文献   
46.
47.
Sixteen balloon expandable Medtronic Wiktor tantalum stents were implanted in the major coronary arteries of six minipigs, which were maintained on a normal diet and given 500 mg aspirin per day. Angiographic and histologic examinations were performed 6 and 26 weeks after implantation. Angiographically reviewed, stenting increased the inner diameter of the coronary arteries from 2.61 ± 0.44 to 3.02 ± 0.34 mm (n = 16, P ≤ 0.001). Six weeks later, this value was reduced from 2.98 ± 0.35 to 2.33 ± 0.46 mm (n = 9, P ≤ 0.05), and between 6 and 26 weeks, an increase from 2.17 ± 0.44 to 2.93 ± 0.40 mm occurred (n = 6, P ≤ 0.05). Histologic evaluation at 26 weeks after stent implantation revealed an increase of the cross-sectional area of the total vessel from 4.30 ± 1.09 to 5.50 ± 1.67 mm2 (n = 9; P ≤ 0.01). This was due to widening of the total vessel and intimal proliferation, which amounted to 1.19 ± 0.46 mm2 within the stented segment, as compared to 0.03 ± 0.03 mm2 in control sections (P ≤ 0.01). The areas of free vessel lumen, media muscularis, and adventitia remained unchanged. In 15 of the 16 hislologically examined coronary arteries, the internal elastica was fractured at the site of stent implantation. Twelve stents had also penetrated through the external elastica without evidence of wall hemorrhage. Thirteen out of 16 stents were angiographically followed, of which 12 were patent at the final reangiography. In one animal, acute thrombosis of the stented vessel after guidewire induced coronary artery spasm caused chronic right heart failure due to right ventricular myocardial infarction. Sudden death occurred in another pig 2 hours after successful implantation of three grossly oversized stents (inner vessel diameter: 2.4 ± 0.2 mm, stent diameter 3.2 ± 0.5 mm). Autopsy revealed extensive dissections of the media with subsequent vessel occlusion. It is concluded that Medtronic Wiktor stents can be placed easily, even in more distal or curved coronary arteries. Despite antiaggregational medication, intimal proliferation is observed early after implantation, reaches a maximum at about 6 weeks, and is followed by a regression 26 weeks poststenting. At 26 weeks follow-up, the free vessel lumen at the stent site was not significantly reduced as compared to control segments. Proper adjustment of internal vessel diameter and stent diameter is necessary to prevent major dissections and thrombotic occlusions.  相似文献   
48.
Although mitral valve repair is a recognized method to surgically treat mitral valve regurgitation, the ideal timing of the operation still is controversial. The goal of this study was to study the long-term results of mitral valve repair focusing on symptomatic versus nonsymptomatic patients. From October 1988 to June 1994, 262 patients (mean age = 57.4) with isolated mitral regurgitation underwent mitral valve repair. Seventy-nine patients (group I) were nonsymptomatic (NYHA Class I or II) and 184 (group II) were severely symptomatic (NYHA III or IV). The surgical techniques have been mainly those described by Alain Carpentier. All patients but three had an annuloplasty with a Carpentier ring. Mean follow-up was 4.02 ± 0.1 years and total follow-up, 972 patient-years. There was one operative death (0.4%). Postoperative Doppler echocardiography showed satisfactory mitral valve function in 97% of the patients and two cases of systolic anterior motion (1%). At 7 years, actuarial survival was 80%± 9%, 95%± 5%, 75%± 11% for the total group, group I, and group II, respectively. At 7 years, freedom from thromboembolic or bleeding complications and reoperation was 96%± 4%, 93%± 8%, and 94%± 3%, respectively. Mitral valve repair for isolated mitral valve regurgitation provides satisfactory survival at 7 years. The long-term survival is better when patients are operated at an early stage when they are still nonsymptomatic.  相似文献   
49.
Background:  Mandatory postoperative food intake has been shown to increase nausea and vomiting, and so postoperative fasting has become common practice even if patients request food or drink.
Objective:  We sought to investigate whether postoperative fasting reduces the incidence of postoperative vomiting in children when compared with a liberal regimen in which they are allowed to eat and drink upon request.
Methods:  One hundred forty-seven children scheduled for outpatient surgery were randomized to one of two groups. After anesthesia, patients in the 'fasting' group were expected to fast for 6 h. The children in the 'liberal' group were allowed to eat and drink according to their own needs. The incidence of vomiting and the children's well-being were recorded at several time points over a 24-hour period. Parents were also asked to rate, on a scale of 0–6, how much their children were bothered by fasting, pain, and nausea/vomiting.
Results:  Age (4.8 ± 2.6 years), weight (20 ± 9 kg) and gender (73% boys) were comparable between the groups. The incidence of vomiting was 15% in the liberal and 22% in the fasting group ( P  = 0.39) and, between 1 and 12 h after extubation, children in the liberal group were significantly happier ( P  < 0.001). Children in the liberal group were significantly less bothered by their pain than those in the fasting group ( P  < 0.001).
Conclusion:  Postoperative fasting did not reduce the incidence of vomiting after general anesthesia in children when compared with a liberal regimen. Furthermore, the ability to eat and drink at will decrease the bothersome aspects of pain and lead to happier patients.  相似文献   
50.
We developed criteria for implantation and programming of permanent endocardial pacemakers in patients with a nonthoracotomy ICD system. These criteria were prospectively used in 10 patients who recieved an ICD prior to (n = 5) or following (n = 5) implantation of a dual chamber (n = 6) or ventricular (n = 4) pacemaker with a unipolar (n = 4) or bipolar (n = 6) lead configuration. All patients were tested for interactions or malfunctions. Undersensing of ventricular fibrillation by the atrial sense amplifier and inadequate atrial pacing occurred in one patient with a unipolar dual chamber system programmed to AAIR but didn't impair ICD sensing. Transient or permanent loss of capture or sensing of the pacemaker was not observed after ICD shocks with the output programmed to double pulse width and voltage of stimulation threshold and the sensitivity to 50% of the detected R wave. One episode of transient reprogramming occurred without clinical consequences. One unipolar ventricular pacemaker lead had to be exchanged against a bipolar lead because of oversensing of the pacing artifact by the ICD. There was no failure of an ICD to detect ventricular arrhythmias due to inadequate pacemaker activity. During a follow-up period of 21 ± 11 months, a total of 78 ventricular arrhythmias were effectively treated in six patients. Thus, a combined use of transvenous ICD and pacemaker is possible despite the close vicinity of pacing and defibrillations leads. Optimized programming different to the common settings is required. As interactions occurred only in unipolar pacemaker leads bipolar systems should be used in these patients.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号