BACKGROUND: Many mild-to-moderately obese individuals (body mass index [BMI] 30-35 kg/m(2)) have serious diseases related to their obesity. Nonoperative therapy is ineffective in the long term, yet surgery has never been made widely available to this population. METHODS: Between 1996 and 2004, 93 patients with a BMI of 30-35 kg/m(2) underwent laparoscopic adjustable gastric banding with the LAP-BAND. All patients were referred by their primary physician, entered into a comprehensive bariatric surgery program at one Australian center, and operated on by one surgeon. Data on all patients were collected prospectively and entered into an electronic registry. The study parameters included preoperative age, gender, BMI, presence of co-morbidities, percentage of excess weight loss, and resolution of co-morbidities. RESULTS: The mean age was 44.6 years (range 16-76), mean weight was 98 kg, and the mean BMI was 32.7 kg/m(2) (range 30-34). Of the 93 patients, 42 (45%) had co-morbidities, including asthma, diabetes, hypertension, and sleep apnea. The proportion of patients in follow-up was 79%, 85%, and 89% at 1, 2, and 3 years, respectively. The mean weight was reduced to 71 kg at 1 year, 72 kg at 2 years, and 72 kg at 3 years. The mean BMI was reduced to 27.2 +/- 2.2, 27.3 +/- 3.1, and 27.6 +/- 3.7 kg/m(2), respectively, and the mean percentage of excess weight loss was 57.9% +/- 24.5%, 57.6 +/- 29.3%, and 53.8% +/- 32.8% at 1, 2, and 3 years, respectively. At 3 years, the BMI was 18-24 kg/m(2) in 34%, 25-29 kg/m(2) in 51%, and 30-35 kg/m(2) in 10%. At 3 years, the percentage of excess weight loss was <25% in 10%, 25-50% in 24%, 50-75% in 51%, and >75% in 10%. The co-morbidities improved or completely resolved in most patients. No mortality occurred. CONCLUSION: We are very encouraged by this series of low BMI patients treated with the LAP-BAND. Their weight loss has been good, the complications have been minimal, and the co-morbidities have partially or wholly resolved. With additional study, it is reasonable to expect the weight guidelines for bariatric surgery to be altered to include patients with a BMI of 30-35 kg/m(2). 相似文献
Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
Abstract: Background: Fetal pulse oximetry improves the assessment of fetal well‐being during labor. The objective of this study was to evaluate women's satisfaction with their experience with this additional technology. Methods: We surveyed women participating in the FOREMOST trial, a randomized controlled trial comparing the addition of fetal pulse oximetry (FPO) to conventional cardiotocograph (CTG) monitoring (intervention group), versus CTG‐only (control group), in the presence of nonreassuring fetal status during labor. Our survey evaluated 3 aspects of women's experience: labor, fetal monitoring, and participation in the research. The survey was administered within a few days of giving birth and repeated 3 months later. Results: No differences were found between the intervention and control groups for women's evaluations of their labor, fetal monitoring, research, or overall experiences when surveyed on both occasions. Within each study group, a small but statistically significant decline occurred in women's scores for their experience of labor and overall experience from the initial survey close to the time of giving birth, to 3 months later. The magnitude of differences in responses over time was similar for the both groups. Women were more satisfied after a spontaneous or assisted vaginal birth than after cesarean section. Length of time the research midwife was present had a significant positive effect on women's ratings of their experience several days after giving birth (p = 0.006), but no effect at 3 months. Conclusions: The addition of fetal pulse oximetry for the assessment of fetal well‐being during labor did not affect childbearing women's perceptions of fetal monitoring or their labor. Women evaluated their experience in the research process positively overall. Small changes occurred in women's perception of their satisfaction over time. (BIRTH 33:2 June 2006)相似文献
OBJECTIVE: To establish reference intervals for the fetal right, left and total lung volumes and heart volume between 12 and 32 weeks of gestation. METHODS: Fetal lung and heart volumes were measured using three-dimensional (3D) ultrasound in 650 normal singleton pregnancies at 12-32 weeks. The VOCAL (Virtual Organ Computer-aided AnaLysis) technique was used to obtain a sequence of six sections of each lung and the heart around a fixed axis, each after a 30 degrees rotation from the previous one. The rotation axis for the lungs extended from the apex to the upper limit of the diaphragm dome, and the rotation axis for the heart extended from its apex to its connection to the great vessels. The contour of each of these organs was drawn manually in the six different rotation planes to obtain the 3D volume measurement. In 60 cases the fetal lungs and heart volumes were measured by the same sonographer twice and also by a second sonographer once in order to compare the measurements and calculate intra- and interobserver agreement. RESULTS: The total lung volume and heart volume increased with gestation, from respective mean values of 1.6 and 0.6 mL at 12 weeks to 10.9 and 4.3 mL at 20 weeks and 49.3 and 26.6 mL at 32 weeks. The right to left lung volume ratio did not change significantly with gestation (median, 0.7), whereas the heart to total lung volume ratio increased with gestation from about 0.3 at 12 weeks to 0.5 at 32 weeks. In the Bland-Altman plot, the difference between paired measurements by two sonographers was, in 95% of the cases, less than 0.05, 0.5 and 1.9 mL for each lung at 12-13, 19-22 and 29-32 weeks, respectively, and the corresponding values for the heart volumes were 0.04, 0.4 and 2.3 mL. CONCLUSIONS: In normal fetuses the lung and heart volumes increase between 12 and 32 weeks of gestation. The extent to which in pathological pregnancies possible deviations in these measurements from normal prove to be useful in the prediction of outcome remains to be determined. 相似文献
OBJECTIVE: To explore the impact of timing and type of ultrasound, particularly three-dimensional (3D), exposure on maternal-fetal attachment and maternal health behavior during pregnancy. METHODS: Subjects were 68 women aged 18 years or older expecting their first child who presented for a routine ultrasound scan at around either 12 or 18 weeks' gestation in Nepean Hospital, Western Sydney. Women completed questionnaires assessing maternal-fetal attachment and health behavior, and were then allocated arbitrarily to either two-dimensional (2D) or 3D ultrasound examination. Repeat questionnaires were completed 1 week later. RESULTS: Maternal-fetal attachment increased after both 2D and 3D ultrasound exposure, and the effect was moderated by the timing of exposure, with women receiving their first ultrasound examination at around 12 weeks showing the greatest change. Alcohol consumption was the only behavior to show significant change following ultrasound exposure, with a reduction in the reported average number of drinks per week. There was no significant difference in the pattern of change for 2D compared with 3D ultrasound exposure, and no effect of ultrasound exposure on maternal perception of the fetus. CONCLUSIONS: Ultrasound has a positive impact on maternal-fetal attachment, particularly in the first trimester. 3D ultrasound did not offer enhanced benefits. Associations between ultrasound exposure and alcohol consumption warrant further investigation. Larger samples are needed to clarify the moderating effects of gestational age and type of ultrasound exposure. 相似文献