Sniff nasal inspiratory pressure (SNIP) measurement is a volitional noninvasive assessment of inspiratory muscle strength. A maximum of 10 sniffs is generally used. The purpose of the present study was to investigate whether the maximum SNIP improved after the tenth sniff. In total, 20 healthy volunteers and 305 patients with various neuromuscular and lung diseases were encouraged to perform 40 and 20 sniffs, respectively. The best SNIP among the first 10 sniffs was lower than the best SNIP among the next 10 sniffs in the healthy volunteers and patients. The SNIP improvement after the twentieth sniff was marginal. In conclusion, a learning effect persists after the tenth sniff. The current authors suggest using 10 additional sniffs when the best result of the first 10 sniffs is slightly below normal, or when sniff nasal inspiratory pressure is used to monitor a progressive decline in inspiratory muscle strength. 相似文献
Bone stock preservation is crucial when performing total hip replacement in young patients. The aim is to save good bone stock
for a possible revision procedure. Furthermore, there is an increasing demand from young and active patients to receive a
new joint which allows a normal or nearly normal life style. With this in mind, we began, in 1993, to develop a new femoral
implant. The purpose of this ultra-short stem was a physiologic strain distribution on the proximal femur with a proximal
load transfer from the implant to the femoral bone. Main features were an almost complete absence of the diaphyseal portion
of the stem, a well defined lateral flare with load transfer on the lateral column of the femur, and a very high femoral neck
cut. These innovations resulted in a conservative implant on both the bone stock and the soft tissues. This implant, in the
first years, was recommended only for young and active patients. Over the last thirteen years, this project has undergone
several modifications but the basic principles of the implant have remained the same. In the present review, we present the
rationale, the surgical technique and the clinical and experimental results so far obtained with this implant. 相似文献
Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
Phenylketonuria (PKU), an inborn error of phenylalanine metabolism, has been shown to be a risk factor for tardive dyskinesia (TD). In male psychiatric patients there was a significant relationship between TD and measures of plasma phenylalanine following ingestion of a standardized phenylalanine dose that was indicative of higher brain availability of phenylalanine in patients with TD. In addition, a medical food formulation consisting of branched chain amino acids, which compete with phenylalanine for transport across the blood-brain barrier, has been demonstrated to be an efficacious treatment for TD. Cumulatively these findings suggested that TD was related to phenylalanine metabolism and thus that sequence variants in the gene for phenylalanine hydroxylase (PAH), the rate-limiting enzyme in the catabolism of phenylalanine, could be associated with TD susceptibility. Genetic screening of PAH in a group of 123 psychiatric patients revealed ten sequence polymorphisms and two mutations, but none appeared to be a significant risk factor for TD. 相似文献
Abstract: Background: Fetal pulse oximetry improves the assessment of fetal well‐being during labor. The objective of this study was to evaluate women's satisfaction with their experience with this additional technology. Methods: We surveyed women participating in the FOREMOST trial, a randomized controlled trial comparing the addition of fetal pulse oximetry (FPO) to conventional cardiotocograph (CTG) monitoring (intervention group), versus CTG‐only (control group), in the presence of nonreassuring fetal status during labor. Our survey evaluated 3 aspects of women's experience: labor, fetal monitoring, and participation in the research. The survey was administered within a few days of giving birth and repeated 3 months later. Results: No differences were found between the intervention and control groups for women's evaluations of their labor, fetal monitoring, research, or overall experiences when surveyed on both occasions. Within each study group, a small but statistically significant decline occurred in women's scores for their experience of labor and overall experience from the initial survey close to the time of giving birth, to 3 months later. The magnitude of differences in responses over time was similar for the both groups. Women were more satisfied after a spontaneous or assisted vaginal birth than after cesarean section. Length of time the research midwife was present had a significant positive effect on women's ratings of their experience several days after giving birth (p = 0.006), but no effect at 3 months. Conclusions: The addition of fetal pulse oximetry for the assessment of fetal well‐being during labor did not affect childbearing women's perceptions of fetal monitoring or their labor. Women evaluated their experience in the research process positively overall. Small changes occurred in women's perception of their satisfaction over time. (BIRTH 33:2 June 2006)相似文献