Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
Abstract: Background: Fetal pulse oximetry improves the assessment of fetal well‐being during labor. The objective of this study was to evaluate women's satisfaction with their experience with this additional technology. Methods: We surveyed women participating in the FOREMOST trial, a randomized controlled trial comparing the addition of fetal pulse oximetry (FPO) to conventional cardiotocograph (CTG) monitoring (intervention group), versus CTG‐only (control group), in the presence of nonreassuring fetal status during labor. Our survey evaluated 3 aspects of women's experience: labor, fetal monitoring, and participation in the research. The survey was administered within a few days of giving birth and repeated 3 months later. Results: No differences were found between the intervention and control groups for women's evaluations of their labor, fetal monitoring, research, or overall experiences when surveyed on both occasions. Within each study group, a small but statistically significant decline occurred in women's scores for their experience of labor and overall experience from the initial survey close to the time of giving birth, to 3 months later. The magnitude of differences in responses over time was similar for the both groups. Women were more satisfied after a spontaneous or assisted vaginal birth than after cesarean section. Length of time the research midwife was present had a significant positive effect on women's ratings of their experience several days after giving birth (p = 0.006), but no effect at 3 months. Conclusions: The addition of fetal pulse oximetry for the assessment of fetal well‐being during labor did not affect childbearing women's perceptions of fetal monitoring or their labor. Women evaluated their experience in the research process positively overall. Small changes occurred in women's perception of their satisfaction over time. (BIRTH 33:2 June 2006)相似文献
BACKGROUND/AIMS: The purpose of this work was to develop a new sensor for objective in vivo measurement of the cutaneous temperature based on micro-electro-mechanical systems (MEMS), and to compare these performances with those of a classical thermocouple. Research on this new sensor was carried out to allow the quantification of the thermal properties of the made-up skin. METHODS: Sixteen female subjects divided into two different age groups (18-35 and >50 years old) were recruited for this study. Several zones of the face and forearms were made up at random with foundations containing or not a thermoregulator raw material. The quantity of foundation applied on the skin was standardized and measurements were carried out first before make-up, and then 10 s and 5 min after make-up. The new sensor and the thermocouple were used successively on each zone. The cutaneous temperature was expressed in degrees celsius. RESULTS/CONCLUSION: The two systems are similar in terms of repeatability and reproducibility, with some differences in sensibility. The data measured by the MEMS sensor appear lower than those measured by the thermocouple. After make-up, the MEMS sensor detects a progressive increase of the temperature in time whereas the thermocouple detects a decrease. We found the same evolution on the face but in a more attenuated way. These results tend to show that the devices do not measure the same phenomenon. The thermocouple appears more sensitive to the thermal response of the made-up surface whereas the MEMS sensor appears more sensitive to the heat transfers in the interface between the skin and make-up. 相似文献
OBJECTIVE: To assess the effect of glucose control on the rate of growth of fetuses in women with pregestational diabetes mellitus (Types 1 and 2). METHODS: All pregestational diabetic women booked at Mater Mothers' Hospital, Brisbane, Australia, between 1 January 1994 and 31 December 2002, were included. Pregnancies with congenital fetal anomalies, multiple pregnancies, and pregnancies terminated prior to 20 weeks' gestation were excluded. Dating scans were performed before 14 weeks' gestation and serial scans were performed at 18, 24, 28, 32 and 36 weeks. Fetal parameters, including biparietal diameter, femur length and abdominal circumference, were recorded. The daily growth rates for biparietal diameter, femur length, and fetal abdominal area were calculated and compared with those in a low-risk (non-diabetic) population. The growth rates in fetuses of women with satisfactory diabetic control (HbA1c < 6.5%) and unsatisfactory control (HbA1c > or = 6.5%) in the three trimesters were compared. RESULTS: A total of 174 diabetic pregnancies were included and a total of 997 ultrasound scans were performed. The growth rates for fetuses of mothers with diabetes mellitus were significantly higher than for those in the low-risk population. The z-scores for biparietal diameter, femur length, and fetal abdominal area were 0.18, 0.59 and 1.44, respectively. Fetuses of diabetic mothers with high HbA1c in the first trimester had significantly greater fetal abdominal area growth rate than those with normal HbA1c (fetal abdominal area z-score of 1.7 vs. 0.75, P = 0.009). Although the fetal abdominal area z-scores in fetuses of diabetic mothers with high HbA1c in the second or third trimesters were also higher than those with normal HbA1c levels, the differences did not reach statistical significance. Maternal obesity did not influence the fetal growth rate. CONCLUSION: The rate of growth of fetuses of diabetic mothers differs from that of the normal population. Growth acceleration persists until the late third trimester. Moreover, periconceptional glucose control appears to have a significant effect on accelerated growth of the fetal abdominal area. 相似文献