PURPOSE: With limited response rates and potential toxicity of chemotherapeutic treatment in patients with recurrent glioma, reliable response assessment is essential. Currently, the assessment of treatment response in glioma patients is based on the combination of radiologic and clinical findings. However, response monitoring with computed tomography (CT) or magnetic resonance imaging (MRI) is hampered by several pitfalls and is prone to interobserver variability. The aim of this study was to establish the value of thallium-201 single-photon emission computed tomography (201Tl-SPECT) as a predictor of overall survival and response to chemotherapy in recurrent glioma, and to compare the value of 201Tl-SPECT with that of CT and MRI. PATIENTS AND METHODS: We studied patients who underwent CT or MRI and 201Tl-SPECT before chemotherapy (n = 57), and patients who also had undergone CT or MRI and 201Tl-SPECT after two courses of chemotherapy (n = 44). The value of the radiologic variables (CT-MRI tumor size, 201Tl-SPECT tumor size, and maximal tumor intensity) at baseline and at follow-up in predicting overall survival, and the percentage of patients alive and progression-free at 6 months (APF6) were examined using Cox regression and logistic regression analysis. RESULTS: Both at baseline and at follow-up, 201Tl-SPECT maximal tumor intensity was the strongest predictive variable and was inversely related to overall survival and APF6. In particular, progression of maximal tumor intensity after two courses of chemotherapy was a powerful predictor of poor outcome. CONCLUSION: 201Tl-SPECT is superior to conventional CT-MRI in the early prediction of overall survival and response to chemotherapy in patients with recurrent glioma. 相似文献
BACKGROUND AND PURPOSE: To compare intensity-modulated treatment plans of patients with head and neck cancer generated by forward and inverse planning. MATERIALS AND METHODS: Ten intensity-modulated treatment plans, planned and treated with a step&shoot technique using a forward planning approach, were retrospectively re-planned with an inverse planning algorithm. For this purpose, two strategies were applied. First, inverse planning was performed with the same beam directions as forward planning. In addition, nine equidistant, coplanar incidences were used. The main objective of the optimisation process was the sparing of the parotid glands beside an adequate treatment of the planning target volume (PTV). Inverse planning was performed both with pencil beam and Monte Carlo dose computation to investigate the influence of dose computation on the result of the optimisation. RESULTS: In most cases, both inverse planning strategies managed to improve the treatment plans distinctly due to a better target coverage, a better sparing of the parotid glands or both. A reduction of the mean dose by 3-11Gy for at least one of the parotid glands could be achieved for most of the patients. For three patients, inverse planning allowed to spare a parotid gland that had to be sacrificed by forward planning. Inverse planning increased the number of segments compared to forward planning by a factor of about 3; from 9-15 to 27-46. No significant differences for PTV and parotid glands between both inverse planning approaches were found. Also, the use of Monte Carlo instead of pencil beam dose computation did not influence the results significantly. CONCLUSION: The results demonstrate the potential of inverse planning to improve intensity-modulated treatment plans for head and neck cases compared to forward planning while retaining clinical utility in terms of treatment time and quality assurance. 相似文献
BACKGROUND AND PURPOSE: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. MATERIALS AND METHODS: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-path length (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, dose-volume histograms (DVHs), the mean lung dose (MLD) and the percentage of lung receiving >20 Gy (V20). Published dose-effect relations for local perfusion changes and radiation pneumonitis were re-evaluated. RESULTS: Evaluation of isodoses showed a consistent overestimation of the dose at the lung/tumor boundary by the EPL algorithm of about 10%. This overprediction of dose was also reflected in a consistent shift of the EPL DVHs for the lungs towards higher doses. The MLD, as determined by the EPL and CS algorithm, differed on average by 17+/-4.5% (+/-1SD). For V20, the average difference was 12+/-5.7% (+/-1SD). For both parameters, a strong correlation was found between the EPL and CS algorithms yielding a straightforward conversion procedure. Re-evaluation of the dose-effect relations showed that lung complications occur at a 12-14% lower dose. The values of the TD(50) parameter for local perfusion reduction and radiation pneumonitis changed from 60.5 and 34.1 Gy to 51.1 and 29.2 Gy, respectively. CONCLUSIONS: A simple tissue inhomogeneity-correction algorithm like the EPL overestimates the dose to normal lung tissue. Dosimetric parameters for lung injury (e.g. MLD, V20) computed using both algorithms are strongly correlated making an easy conversion feasible. Dose-effect relations should be refitted when more accurate dose data is available. 相似文献
PURPOSE: To review the radiotherapy department experience in treating primary spinal cord ependymomas (PSCE), analyse prognostic factors and provide treatment recommendations regarding literature review. MATERIALS AND METHODS: Sixteen patients with PSCE received postoperative radiotherapy between 1972 and 1997. There were 10 male and 6 female patients with a mean age of 34 years (range 2-63). Surgery was gross total resection in 2 cases, subtotal resection in 9, biopsy in 4 and of unknown type in one patient. All patients were treated with radiotherapy to the craniospinal axis (4 cases), spinal cord (1 case) and to the site of primary tumour in 11 cases. RESULTS: Five year-survival rate was 73%. Two patients had recurrent tumours within the primary site. Gender, extent of surgery and treatment field extent were not prognostic factors. Histologic type was the only variable predictive of outcome. Patients with myxopapillary type had a 5-year survival rate of 100% compared with 47% for those with other histology types. CONCLUSION: We conclude that aggressive surgery is not necessary in the management of PSCE, localised field radiotherapy is associated with favourable outcome, and tumour grade is an important prognostic factor. 相似文献
We present the first use of tubeless superimposed combined high- and low-frequency jet ventilation (SHFJV) with a jet laryngoscope in laryngotracheal surgery in infants and children. Twenty-eight patients underwent 53 operative procedures. The average age of the patients was 7.3 years. The most common diagnoses were laryngeal papillomatosis and subglottic stenosis. The duration of jet ventilation averaged 33 min. The gas exchange was sufficient in each case. The advantages of SHFJV in the surgery of the laryngotracheal area in infants and children are optimal view at the larynx and trachea, maximum space for the handling, application of the laser without risks, no time limitation, suitability for stenosis, and neither anesthetic nor surgical complications. 相似文献
Objective: The combination of transvaginal sonography and serum hCG measurement is reliable in the diagnosis of ectopic pregnancy (EP) in spontaneous pregnancies. In patients who became pregnant through IVF-ET, transfer of multiple embryos after IVF could be responsible for the different performance of these tests. We evaluated the discriminative capacity of transvaginal sonography in combination with hCG measurement in the diagnosis of EP after IVF-ET.
Design: Prospective cohort study.
Setting and Patient(s): Consecutive patients, pregnant through IVF-ET, who presented with clinically suspected EP.
Intervention(s): Transvaginal sonography, serum hCG measurement at 6, 9, and 15 days after ET and after a negative transvaginal sonography.
Main Outcome Measure(s): Ectopic pregnancy confirmed at laparoscopy.
Result(s): Between September 1993 and May 1996, 86 women were included in the study, of whom 24 had an EP. Transvaginal sonography identified 46 intrauterine pregnancies and 5 EPs, but serum hCG could not diagnose EPs in patients in whom transvaginal sonography did not show a gestational sac. Serum hCG measurement 9 days after ET could identify pregnancy failure with 100% specificity at a cut-off value of 18 IU/L, but it could not identify patients with EP with enough certainty to justify immediate treatment.
Conclusion(s): We recommend single serum hCG measurement 9 days after ET to discriminate between viable and nonviable pregnancies. Transvaginal sonography can be postponed until 5 weeks after ET, except for patients with abdominal pain and/or vaginal bleeding, or patients with a serum hCG level of <18 IU/L. 相似文献