Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
BACKGROUND/AIMS: The purpose of this work was to develop a new sensor for objective in vivo measurement of the cutaneous temperature based on micro-electro-mechanical systems (MEMS), and to compare these performances with those of a classical thermocouple. Research on this new sensor was carried out to allow the quantification of the thermal properties of the made-up skin. METHODS: Sixteen female subjects divided into two different age groups (18-35 and >50 years old) were recruited for this study. Several zones of the face and forearms were made up at random with foundations containing or not a thermoregulator raw material. The quantity of foundation applied on the skin was standardized and measurements were carried out first before make-up, and then 10 s and 5 min after make-up. The new sensor and the thermocouple were used successively on each zone. The cutaneous temperature was expressed in degrees celsius. RESULTS/CONCLUSION: The two systems are similar in terms of repeatability and reproducibility, with some differences in sensibility. The data measured by the MEMS sensor appear lower than those measured by the thermocouple. After make-up, the MEMS sensor detects a progressive increase of the temperature in time whereas the thermocouple detects a decrease. We found the same evolution on the face but in a more attenuated way. These results tend to show that the devices do not measure the same phenomenon. The thermocouple appears more sensitive to the thermal response of the made-up surface whereas the MEMS sensor appears more sensitive to the heat transfers in the interface between the skin and make-up. 相似文献
OBJECTIVE: To establish reference intervals for the fetal right, left and total lung volumes and heart volume between 12 and 32 weeks of gestation. METHODS: Fetal lung and heart volumes were measured using three-dimensional (3D) ultrasound in 650 normal singleton pregnancies at 12-32 weeks. The VOCAL (Virtual Organ Computer-aided AnaLysis) technique was used to obtain a sequence of six sections of each lung and the heart around a fixed axis, each after a 30 degrees rotation from the previous one. The rotation axis for the lungs extended from the apex to the upper limit of the diaphragm dome, and the rotation axis for the heart extended from its apex to its connection to the great vessels. The contour of each of these organs was drawn manually in the six different rotation planes to obtain the 3D volume measurement. In 60 cases the fetal lungs and heart volumes were measured by the same sonographer twice and also by a second sonographer once in order to compare the measurements and calculate intra- and interobserver agreement. RESULTS: The total lung volume and heart volume increased with gestation, from respective mean values of 1.6 and 0.6 mL at 12 weeks to 10.9 and 4.3 mL at 20 weeks and 49.3 and 26.6 mL at 32 weeks. The right to left lung volume ratio did not change significantly with gestation (median, 0.7), whereas the heart to total lung volume ratio increased with gestation from about 0.3 at 12 weeks to 0.5 at 32 weeks. In the Bland-Altman plot, the difference between paired measurements by two sonographers was, in 95% of the cases, less than 0.05, 0.5 and 1.9 mL for each lung at 12-13, 19-22 and 29-32 weeks, respectively, and the corresponding values for the heart volumes were 0.04, 0.4 and 2.3 mL. CONCLUSIONS: In normal fetuses the lung and heart volumes increase between 12 and 32 weeks of gestation. The extent to which in pathological pregnancies possible deviations in these measurements from normal prove to be useful in the prediction of outcome remains to be determined. 相似文献
OBJECTIVE: To explore the impact of timing and type of ultrasound, particularly three-dimensional (3D), exposure on maternal-fetal attachment and maternal health behavior during pregnancy. METHODS: Subjects were 68 women aged 18 years or older expecting their first child who presented for a routine ultrasound scan at around either 12 or 18 weeks' gestation in Nepean Hospital, Western Sydney. Women completed questionnaires assessing maternal-fetal attachment and health behavior, and were then allocated arbitrarily to either two-dimensional (2D) or 3D ultrasound examination. Repeat questionnaires were completed 1 week later. RESULTS: Maternal-fetal attachment increased after both 2D and 3D ultrasound exposure, and the effect was moderated by the timing of exposure, with women receiving their first ultrasound examination at around 12 weeks showing the greatest change. Alcohol consumption was the only behavior to show significant change following ultrasound exposure, with a reduction in the reported average number of drinks per week. There was no significant difference in the pattern of change for 2D compared with 3D ultrasound exposure, and no effect of ultrasound exposure on maternal perception of the fetus. CONCLUSIONS: Ultrasound has a positive impact on maternal-fetal attachment, particularly in the first trimester. 3D ultrasound did not offer enhanced benefits. Associations between ultrasound exposure and alcohol consumption warrant further investigation. Larger samples are needed to clarify the moderating effects of gestational age and type of ultrasound exposure. 相似文献