Background: Inhibition of intestinal peristalsis is a major side effect of drugs used for anesthesia or for analgesia and sedation of patients in the intensive care unit. This in vitro study examined the effect of clonidine and dexmedetomidine on intestinal peristalsis and analyzed some of their mechanisms of action.
Methods: In isolated segments of the guinea pig small intestine, peristalsis was triggered by a perfusion-induced rise of the intraluminal pressure. The peristaltic pressure threshold to elicit a peristaltic wave was used to quantify drug effects on peristalsis. Vehicle (Tyrode's solution), clonidine (10 nm-100 [mu]m), or dexmedetomidine (0.1-100 nm) were added extraserosally to the organ bath. In other series of experiments, clonidine or dexmedetomidine was administered after pretreatment with yohimbine, prazosin, apamin, naloxone, or vehicle. Clonidine was also tested after blockade of NO synthase with l-NAME and in the presence of the inactive enantiomer d-NAME.
Results: Clonidine and dexmedetomidine concentration-dependently increased peristaltic pressure threshold and inhibited peristalsis (clonidine: EC50 = 19.6 [mu]m; dexmedetomidine: EC50 = 12.0 nm). The inhibition caused by clonidine could be prevented by pretreatment with yohimbine, naloxone, and apamin, but not by prazosin, l-NAME, or d-NAME. Inhibition caused by dexmedetomidine was prevented by yohimbine only. 相似文献
Normal blood flow and velocity in the superior sagittal sinus were measured in 30 patients. A fast two-dimensional ungated phase-contrast (PC) pulse sequence was compared with a peripherally gated cine PC technique for velocity and flow quantitation. The same imaging parameters were used for both methods. Measured values for mean velocity and flow obtained with the two methods were compared by using regression analysis and t testing. For blood flow, the correlation coefficient was 0.976. For velocity measurements, r was 0.950. Mean flow was 285 mL/min ± 19 with the ungated PC method and 281 mL/min ± 19 with the cine PC method. The mean velocities measured with the two methods were 12.94 cm/sec ± 1.1 and 13.59 cm/sec ± 1.1, respectively. There was no significant difference (paired t test) between the methods for mean flow or velocity data. This was true even though flow in the superior sagittal sinus is moderately pulsatile, as shown with the cine PC technique. The ungated PC method provided these data in 13 seconds versus 3.5 minutes for the cine PC method. 相似文献
The purpose of this investigation was to determine differences in tissue composition of symptomatic and asymptomatic disc herniations as reflected in T1 and T2 relaxation times (quantitative magnetic resonance investigation of the lumber spine. The longitudinal and transverse magnetic rlaxation times (T1 and T2, respectively) were calculated from a set of 20 images obtained with five single-slice/multi-echo sequences at different repetition time values on a commercial whole-body system (1.5 T). Twenty-two symptomatic and asymptomatic disc herniations could be matched according to age, gender, disc level, and the extent of herniation (protrusion or extrusion) and were compared with regard to T1 and T2 relaxation times. Symptomatic disc herniations exhibited significantly (pT1 < 0.04 and pT2 < 0.003) shorter T1(ΔT1:–182.1 milliseconds, ?15%) and T2(ΔT2: ?11.0 milliseconds, ?21%) relaxation times than matched asymptomatic herniations. Symptomatic disc herniations also exhibited more advanced disc degeneration as graded by Pearce's criteria (p < 0.01). These results suggest that symptomatic and morphologically matched asymptomatic disc herniations differ with regard to disc matrix composition. 相似文献
Summary. We present a case of primary plasmocytoma of the left upper bronchus. Occlusion led to atelectasis of the left upper lobe
and subsequent poststenotic pneumonia. Therapy consisted of local excision of the bronchus and postoperative radiotherapy.
This type of lung-conserving therapy in a case of primary plasmocytoma has not been described before.
相似文献
The reproducibility of myocardial motion trajectories calculated from cine phase-contrast (PC) velocity data is reduced by artifacts due to the inconsistent motion of intracardiac blood. Spatial presaturation reduces these artifacts but requires a longer sequence TR, with a potentially negative effect on trajectory accuracy and reproducibility. We investigated the effect of spatial presaturation on trajectory reproducibility. A midventricular transaxial slice was imaged in five normal volunteers. The same slice was imaged three times each with sequences using spatial presaturation or not. Because the most serious artifacts originate in the heart chambers and propagate in the phase-encoded direction, myocardial regions that were in line with the heart chambers (in the phase-encode direction) had the highest artifact level in the scans without spatial presaturation. The reproducibility of trajectories for regions placed in these areas (the anterior wall, septum and posterior wall in the transaxial scans with phase encoding in the anterior-posterior direction) improved by a factor of two when presaturation was used (P < .001). In areas that were not in line with the heart chambers (eg, the anterior aspect of the lateral wall in the transaxial scans), the effect of presaturation was not significant. These results correlate well with the measured reduction in artifact level. The reproducibility of myocardial motion trajectories over large areas of the heart is improved to approximately 1 mm when presaturation is used. Therefore, use of presaturation is recommended for myocardial motion studies using cine PC velocity data. 相似文献
This case report illustrates atypical magnetic resonance (MR) imaging findings in a liver hemangioma mimicking a malignant lesion—lower signal intensity than cerebrospinal fluid on T2-weighted spin-echo images and lack of early enhancement on dynamic contrast material—enhanced gradient-echo images. Pathologic analysis demonstrated nearly total replacement of the vascular cavities by dense fibrous tissue. In this rare, sclerosed form, this lesion could not be defined as a hemangioma with MR imaging. 相似文献
A convenient approach to the new 2-aminobenzophenone analogue 4 is reported. Condensation reactions of 4 with ortho esters or amide acetals, respectively, followed by intramolecular cyclisations were found to provide smooth access to (4-pyridazinyl)-substituted quinolines 10, 13a,b , and the quinazoline derivative 15 . 相似文献