Background: The daily consumption of dietary fiber is frequently below suggested recommendations. Using a double‐blind, controlled, randomized study, we assessed the efficiency and tolerance of a fiber‐enriched orange juice to supplement fiber intake in women. Materials and Methods: After 1 week of noninterventional observation, 192 healthy adult women ingested 400 mL of orange juice for 21 days, which either was not (placebo group) or was enriched with fiber (fiber group). Orange juice ingestion was registered daily and controlled for each week during the study period. Macronutrient, fiber, and energy intake were determined using a 3‐day food record, validated food chemical composition databases, and the “Pro Diet” software. Gastrointestinal symptoms were self‐evaluated daily by scoring 4 grades of symptom intensity and using a visual analog scale to grade pain severity. Results: No changes were observed for macronutrient and energy ingestion. For the placebo group (n = 97), the total fiber intake record was under the daily recommended value. In contrast, the fiber group (n = 95) displayed higher comparative values of total and soluble fiber consumption (P ≤ .001), achieving the daily recommended values of fiber intake. Both groups reported an increased frequency of slight bloating and rumbles over time (P ≤ .05). The fiber group also experienced a higher frequency of slight flatulence over time (P = .002). Conclusion: Consumption of fiber‐enriched orange juice was efficient to achieve the daily fiber intake recommendation for women, was not accompanied by intense adverse events, and may represent a suitable method to supplement fiber intake in woman. 相似文献
The value of a predischarge exercise test combined with thallium-201 myocardial scintigraphy in detecting patients with severe multivessel disease (MVD) was studied in 58 consecutive patients discharged after a first acute myocardial infarction. Twelve electrocardiographic, clinical and scintigraphic variables were analysed. Angiography at one month revealed MVD (greater than 70% narrowing in vessels unrelated to infarction) in 26 patients (45%). ST segment depression of 1mm or greater, thallium defects in multiple vascular distributions (MVTL), and reversible thallium defects in a vascular distribution different from the infarct related vessel predicted patients at risk for MVD (predictive value respectively of 68%, 65% and 75%). The other variables were not significantly associated with the presence of MVD. Only ST segment depression and thallium defects in multiple vascular distributions emerged as independent predictors of MVD. Their combination yielded a 77% sensitivity and a 59% specificity for MVD. Combination of thallium imaging with the predischarge exercise ECG significantly improved the stratification provided by the exercise test alone (P less than 0.05). A positive thallium scan (MVTl defects) associated with a positive ECG (ST depression) carried a risk for MVD of 80% in the population studied. When both tests were negative, MVD was infrequent (risk 22%). Because improvement in the stratification of patients is not as clear as expected from studies performed at a later stage, it appears that exercise thallium scintigraphy at a submaximal level one or two weeks after infarction does not provide optimal information. Predischarge exercise thallium-201 scintigraphy, however, is superior to an exercise tolerance test alone in separating patients into those with high and low risk of MVD. 相似文献
Nodular regenerative hyperplasia of the liver is an infrequent condition characterized by transformation of the hepatic parenchyma into nodules with only mild fibrosis. Little is known about the etiology except that there is usually an underlying chronic disease, such as Felly's syndrome, which antedates the development of clinical liver disease. It is poorly understood how the associated diseases contribute to the pathogenesis of nodular regenerative hyperplasia. Presented are four cases of nodular regenerative hyperplasia in which macroglobulinemia was also present. This new association suggests to us a hypothesis for the pathogenesis of nodular regenerative hyperplasia.
Histologic examination of the livers in these and other cases of nodular regenerative hyperplasia reveals widespread obliteration of the small portal veins. Postmortem angiography of one liver in the present series demonstrated that the nodules were well perfused and that the atrophic areas were poorly perfused with portal blood. This supports the view that atrophy of lobules results from a lack of portal blood supply and that nodules develop from lobules well supplied with portal blood. In each of the clinical conditions associated with nodular regenerative hyperplasia, including macroglobulinemia, inflammatory or thrombotic vascular lesions are found in many organs. Therefore, nodular regenerative hyperplasia may be the hepatic expression of a more widespread vascular disease. 相似文献
BACKGROUND AND AIM OF THE STUDY: Intraoperative transesophageal echocardiography (TEE) is commonly used during aortic valve surgery. In aortic valve replacement (AVR), this permits measurement of the aortic annulus, study of the anatomy of aortic valve components, and prediction of prosthesis valve size. After cardiopulmonary bypass (CPB), echocardiography is valuable in checking prosthesis function. In this study, we evaluated the impact of intraoperative TEE on the decision-making process of aortic Toronto stentless prosthetic valve (TSPV) implantation. METHODS: Fifty-two consecutive patients undergoing elective AVR were collected prospectively. Multiplane TEE was performed before CPB to determine diameters of the aortic valve annulus and sinotubular junction. This was to evaluate the feasibility of TSPV implantation in the aortic position and to predict prosthesis size. Further TEE evaluation was carried out after CPB to assess prosthetic valve function. RESULTS: TEE allowed measurement of the aortic annulus and sinotubular junction, and enabled correct prediction of prosthesis size. Ultrasonic evaluation also revealed contraindications to TSPV implantation in five patients. In one case, color-Doppler examination led to immediate successful surgical correction of prosthetic incompetence. CONCLUSION: Intraoperative multiplane TEE examination is useful in the decision-making process in AVR with the TSPV by selecting patients suitable for the stentless valve, predicting prosthesis size, and checking prosthesis function. 相似文献
To assess the presence of viable myocardium salvaged by coronary artery reperfusion, 17 patients with acute anterior myocardial infarction were studied. Each received intravenous thrombolysis within the first 3 h of symptoms and underwent two-dimensional echocardiography before and during dobutamine infusion (10 micrograms/kg per min) 7 +/- 4 days after admission and positron emission tomography 9 +/- 5 days after admission. Echocardiography and positron emission tomography were again performed 9 +/- 7 months later. Six comparable segments specific for the territory of the left anterior descending artery were selected for comparison of the two techniques. Wall thickening was evaluated by using an echocardiographic score index. Segmental perfusion and glucose uptake were measured and normalized to the peak activity. A ratio of glucose uptake to perfusion was calculated for each segment. Concordant interpretation of the two techniques was found in 79% of affected segments for both acute and follow-up studies. Positron emission tomography revealed the presence of viable myocardium in 11 patients (group 1); perfusion was within normal limits in 5 of these (group 1A). Myocardial thickening improved with dobutamine infusion in these five patients, the echocardiographic score index decreasing from 12 +/- 2 at rest to 7.8 +/- 1.3 during dobutamine infusion (p = 0.003). Functional recovery was demonstrated in all five patients (follow-up score index 7.4 +/- 1.7). Six patients exhibited decreased perfusion but an abnormally high glucose to perfusion ratio (group 1B); their score index improved with dobutamine from 14.8 +/- 2.2 to 12 +/- 2.1 (p = 0.05), but late functional recovery was found in only one of the six patients (mean follow-up score index in group 1B 16 +/- 1.7). In the six remaining patients in whom no viable myocardium was detected with positron emission tomography (group 2), the echocardiographic score index did not change with dobutamine (15 +/- 0.9 to 14.7 +/- 0.8, p = NS) and there was no functional recovery (follow-up score index 15.5 +/- 1.0). Echocardiography during dobutamine infusion is a promising method to unmask viable myocardium in acute myocardial infarction. Early recovery of perfusion in the area at risk is associated with a good functional outcome, whereas a high glucose to perfusion ratio indicates jeopardized myocardium that frequently loses viability. 相似文献
ObjectiveDespite the increased use of monolithic crowns, their performance has yet to be determined when the minimal tooth preparation (MTP) principle is considered. The goal of this study was to evaluate the effect of MTP on the mechanical behavior, reliability and translucency of posterior monolithic ceramic crowns.MethodsDentin analogues were machined using two preparation designs (0.5 or 1 mm reduction) to receive first molar crowns in order to evaluate the monolithic crown performance. Next, 126 crowns were divided (21/g) according to the material (High translucent zirconia – YZHT, Zirconia reinforced lithium silicate – ZLS and Hybrid ceramic – HC) and thickness (0.5 or 1 mm). Tensile stress concentration was calculated using the finite element method. The crowns were adhesivelly cemented and step stress fatigued to calculate reliability for missions at 600 and 1000 N. Translucency was analyzed in 10 discs of each material and thickness.ResultsHigher stress concentration was found in thinner crowns and those with higher elastic modulus. YZHT crowns were suspended when fatigue reached 1500 N load, thus 1-parameter Weibull was used to analyze the data. Reliability was only affected by thickness at 1000 N. ZLS.5 showed lower survival than HC.5, which was similar to the groups that presented 100% survival. YZHT showed the highest strength and data scattering. ZLS1 (22.3 ± 1.4) presented higher translucency than HC1 (19.2 ± 0.6) and YZHT1 (12.0 ± 2.9), whereas ZLS.5 and HC.5 were similar to each other (26.5 ± 2.3, 26.7 ± 2.2) and superior to YZHT.5 (12.7 ± 1.2).SignificanceHC.5 combined high reliability and translucency with low stress concentration, yielding better crown performance and tooth preservation. 相似文献