To investigate whether functional overreaching affects locomotor system behaviour when running at fixed relative intensities and if any effects were associated with changes in running performance.
Design
Prospective intervention study.
Methods
Ten trained male runners completed three training blocks in a fixed order. Training consisted of one week of light training (baseline), two weeks of heavy training designed to induce functional overreaching, and ten days of light taper training designed to allow athletes to recover from, and adapt to, the heavy training. Locomotor behaviour, 5-km time trial performance, and subjective reports of training status (Daily Analysis of Life Demands for Athletes (DALDA) questionnaire) were assessed at the completion of each training block. Locomotor behaviour was assessed using detrended fluctuation analysis of stride intervals during running at speeds corresponding to 65% and 85% of maximum heart rate (HRmax) at baseline.
Results
Time trial performance (effect size ±95% confidence interval (ES): 0.16 ± 0.06; p < 0.001), locomotor behaviour at 65% HRmax (ES: ?1.12 ± 0.95; p = 0.026), and DALDA (ES: 2.55 ± 0.80; p < 0.001) were all detrimentally affected by the heavy training. Time trial performance improved relative to baseline after the taper (ES: ?0.16 ± 0.10; p = 0.003) but locomotor behaviour at 65% HRmax (ES: ?1.18 ± 1.17; p = 0.048) and DALDA (ES: 0.92 ± 0.90; p = 0.045) remained impaired.
Conclusions
Locomotor behaviour during running at 65% HRmax was impaired by functional overreaching and remained impaired after a 10-day taper, despite improved running performance. Locomotor changes may increase injury risk and should be considered within athlete monitoring programs independently of performance changes. 相似文献
Iatrogenic injury of the Profunda Femoris Artery (PFA) at time of hip fixation surgery can increase morbidity and mortality and prolong the hospital stay. This is an injury that tends to pass unnoticed as a cause of postoperative deterioration despite being frequently reported in the literature. Our study aims to describe the anatomy of the PFA in relation to the medial femoral cortex with specific emphasis on its orientation relative to the position of a sliding hip screw side plate construct. By doing so we are able to present clear guidance to orthopaedic surgeons on how to avoid iatrogenic PFA injury at the time of hip fracture fixation.
Methods
Using Computed Tomography Angiographic (CTA) studies, the course of the PFA in relation to the medial femoral cortex was traced in 44 patients (28 males and 16 females) with mean age of 65.6 years. Coronal and axial CT sections were cross-linked to specify the position of the PFA at 1?cm intervals.
Results
The course of the artery could be divided into three parts relative to a fixed reference point. Proximal and distal parts of the artery were in a safer position in comparison to the middle part of the artery that was found very close to the femoral cortex and along the coronal axis of the femur (mean angle 2.9° from the femoral coronal axis and 13.8?mm from the medial femoral cortex). Using the commercially available side plate constructs, this part of the artery corresponded to the distal part of the plate (third and fourth holes).
Conclusion
Special attention needs to be practiced by the operating surgeon while drilling into the third and fourth holes of the side plate. 相似文献
To determine whether differences in combination DTaP vaccine types at 2, 4 and 6?months of age were associated with mortality (all-cause or non-specific), within 30?days of vaccination.
Design
Observational nationwide cohort study.
Setting
Linked population data from the Australian Childhood Immunisation Register and National Death Index.
Participants
Australian infants administered a combination trivalent, quadrivalent or hexavalent DTaP vaccine (DTaP types) between January 1999 and December 2010 at 2, 4 and 6?months as part of the primary vaccination series. The study population included 2.9, 2.6, & 2.3?million children in the 2, 4 and 6?month vaccine cohorts, respectively.
Main outcome measures
Infants were evaluated for the primary outcome of all-cause mortality within 30?days. A secondary outcome was non-specific mortality (unknown cause of death) within 30?days of vaccination. Non-specific mortality was defined as underlying or other cause of death codes, R95 ‘Sudden infant death syndrome’, R96 ‘Other sudden death, cause unknown’, R98 ‘Unattended death’, R99 ‘Other ill-defined and unspecified cause of mortality’ or where no cause of death was recorded.
Results
The rate of 30?day all-cause mortality was low and declined from 127.4 to 59.3 deaths per 100,000 person-years between 2 and 6?month cohorts. When compared with trivalent DTaP vaccines, no elevated risk in all-cause or non-specific mortality was seen with any quadrivalent or hexavalent DTaP vaccines, for any cohort.
Conclusion
Use of routine DTaP combination vaccines with differing disease antigens administered during the first six months of life is not associated with infant mortality. 相似文献
ABSTRACTA monocausal bacteriological understanding of infectious disease orients tuberculosis control efforts towards antimicrobial interventions. A bias towards technological solutions can leave multistranded public health and social interventions largely neglected. In the context of globalising biomedical approaches to infectious disease control, this ethnography-inspired review article reflects upon the implementation of rapid diagnostic technology in low- and middle-income countries. Fieldwork observations in Vietnam provided a stimulus for a critical review of the global rollout of tuberculosis diagnostic technology. To address local needs in tuberculosis control, health managers in resource-poor settings are readily cooperating with international donors to deploy novel diagnostic technologies throughout national tuberculosis programme facilities. Increasing investment in new diagnostic technologies is predicated on the supposition that these interventions will ameliorate disease outcomes. However, suboptimal treatment control persists even when accurate diagnostic technologies are available, suggesting that promotion of singular technological solutions can distract from addressing systemic change, without which disease susceptibility, propagation of infection, detection gaps, diagnostic delays, and treatment shortfalls persist. 相似文献
One approach to boost influenza vaccination coverage has been to expand immunization authority. In 2012, the province of Ontario gave community pharmacists the authority to administer the influenza vaccine.
Objective
This study investigates the perspectives of Ontario pharmacy patrons, who had not recently received this vaccine from a pharmacist, regarding this pharmacist service.
Methods
A survey was administered in six Ontario community pharmacies to pharmacy patrons who had not received an influenza vaccination from a pharmacist during the previous year. The instrument included questions about influenza vaccination, and knowledge of and attitudes toward vaccines and pharmacist-administered immunization.
Results
A total of 541 pharmacy patrons completed the survey (53.9% response rate). About one-third (30.5%) of respondents were not aware that pharmacists could give the influenza vaccine, with younger individuals being less likely to be aware (OR 0.48, 95% CI 0.29–0.77, p?<?0.05) and less likely to receive the vaccine annually (OR 0.28, 95% CI 0.19–0.42, p?<?0.05). Leading reasons respondents gave as to why they did not receive their influenza vaccine from a pharmacist included not wanting or feeling they needed to be immunized (41.6%) and being used to receiving the vaccine from a physician (16.5%). Concerns about the experience and training of pharmacists and lack of privacy in a community pharmacy were uncommon.
Conclusion
Reduced awareness of the availability of pharmacist-provided influenza vaccine is still common. Pharmacists have a significant opportunity to address lack of awareness and vaccine hesitancy issues. They can promote this service to increase influenza vaccination rates among pharmacy patrons who do not utilize this professional service. 相似文献
Although classified by the Joint Monitoring Programme (JMP) as unimproved sanitation facilities, public toilets still play a critical role in eliminating open defecation in informal settlements. We explored perspectives of toilet operators on opportunities and barriers to operation and maintenance (O&M) of public toilets in informal settlements. A cross-sectional study design was used. Up to 20 in-depth interviews were used to obtain data on the experiences of public toilet operators. Thematic content analysis was used.
Ressults show that opportunities for improving O&M include; operation of public toilets is a source of livelihood; operators are knowledgeable on occupational risks, and the community is involvedin sanitation activities. Barriers to effective O&M include; high operation costs, failure to break even and a lack of investments in occupational health Therefore, there is need to recognise the significance of public toilets as a viable alternative to open defecation in areas where ownership of private sanitation facilities is difficult. Failure to observe the health and safety of toilet operators may further compromise O&M. 相似文献
Physicians treating nonvalvular atrial fibrillation (AF) assess stroke and bleeding risks when deciding on anticoagulation. The agreement between empirical and physician-estimated risks is unclear. Furthermore, the association between patient and physician sex and anticoagulation decision-making is uncertain.
Methods
We pooled data from 2 national primary care physician chart audit databases of patients with AF (Facilitating Review and Education to Optimize Stroke Prevention in Atrial Fibrillation and Coordinated National Network to Engage Physicians in the Care and Treatment of Patients with Atrial Fibrillation Chart Audit) with a combined 1035 physicians (133 female, 902 male) and 10,927 patients (4567 female and 6360 male).
Results
Male physicians underestimated stroke risk in female patients and overestimated risk in male patients. Female physicians estimated stroke risk well in female patients but underestimated the risk in male patients. Risk of bleeding was underestimated in all. Despite differences in risk assessment by physician and patient sex, > 90% of patients received anticoagulation across all subgroups. There was modest agreement between physician estimated and calculated (ie, CHADS2 score) stroke risk: Kappa scores were 0.41 (0.35-0.47) for female physicians and 0.34 (0.32-0.36) for male physicians.
Conclusions
Our study is the first to examine the association between patient and physician sex influences and stroke and bleeding risk estimation in AF. Although there were differences in agreement between physician estimated stroke risk and calculated CHADS2 scores, these differences were small and unlikely to affect clinical practice; further, despite any perceived differences in the accuracy of risk assessment by sex, most patients received anticoagulation. 相似文献
OBJECTIVE: A series of nasopharyngeal appliance designs is presented that represents our evolving experience over a 20-year period in the adjunctive use of prosthetic stents in the surgical correction of nasopharyngeal stenosis. DESIGN: Retrospective assessment of effectiveness of two nasopharyngeal stenosis hollow stent designs in a consecutive series of patients for relief of nasal obstructive symptoms. SETTING: Tertiary academic medical center, Craniofacial Program at Children's Hospital. PATIENTS: Four patients with nasopharyngeal stenosis were treated with a preoperatively fabricated stent made from a clasped palatal appliance onto which hollow acrylic conduits were extended through surgically re-created pharyngeal ports. A subsequent set of four patients with nasopharyngeal stenosis were treated with intraoperatively-fashioned silastic grommets, as opposed to palatal appliances. INTERVENTIONS: Postoperative intraoral stenting of nasopharyngeal ports. MAIN OUTCOME MEASURES: Maintenance of pharyngeal port opening after 1 year, improvement in nasal airway obstructive symptoms. RESULTS: The palatal appliance stents were less well tolerated and had a lower maintenance of port patency after device removal (4 of 8, 50%). The silastic grommets provided better retention into the ports and increased patient tolerance, as well as better 1-year port maintenance (6 of 8, 75%). CONCLUSIONS: The grommet stent appliance offers numerous advantages over a conventional dental-clasped appliance for prosthetic nasopharyngeal stenting, including obviation of extensive preoperative preparation, ease of insertion and removal, and exchange of air during the stenting period. Improved nasopharyngeal patency with this device may be due to greater patient tolerance and subsequent longer use. 相似文献