BACKGROUND: The aim of this study was to estimate the cost effectiveness of screening for abdominal aortic aneurysm (AAA). MATERIAL AND METHODS: All 12,639 men born in the years 1921-1933 (aged 64-73) living in Viborg County, Denmark, were randomly allocated either to receive an invitation to abdominal ultrasound scanning for AAA or to be controls. Costs for screening and surveillance were assessed prospectively. Diagnosis Related Group (DRG) costs from 1999 were used concerning admissions with uncomplicated and complicated operations. Admissions for AAA surgery were retrospectively classified according to complications in patient records. RESULTS: Mean follow-up time was 52 months. 76.6% of invited men attended screening, and 191 (4.0%) had an AAA. As previously reported, the cumulative 5-year AAA-specific mortality in the invited group was significantly reduced by 67% compared to the control group (P = 0.003). The costs were estimated to be Euro 11.23 per scan. The costs per life-year saved were Euro 9057 (Euro 5872-20,063) after 5 years, and were expected to decrease to Euro 2708 (Euro 1758-6031) after 10 years and to Euro 1825 (Euro 1185-4063) after 15 years. CONCLUSION: Screening of 64-73 years old males in Denmark seems cost effective. 相似文献
For patients who receive a liver transplant (LTX) for alcoholic liver disease (ALD), investigators are focusing beyond survival to determine specific alcohol use outcomes. Studies suggest the use of alcohol ranges from 8 to 22% for the first post-transplant year with cumulative rates reaching 30 to 40% by 5 years following transplantation. Yet while investigators are interested in determining specific rates of alcohol use and predictors of use, only three studies since 1990 have been prospective. In 1998, we began a prospective study of post-LTX alcohol consumption in ALD recipients using multiple repeated measures of alcohol use. After 5 years of follow-up, we found that 22% had used any alcohol by the first year and 42% had a drink by 5 years. By 5 years, 26% drank at a heavier use (binge) pattern and 20% drank in a frequent pattern. In a univariate model, predictors of alcohol use included pre-transplant length of sobriety, a diagnosis of alcohol dependence, a history of other substance use, and prior alcohol rehabilitation. 相似文献
Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
BACKGROUND: Three dimensional skin equivalents are widely used in dermatopharmacological and toxicological studies and as autologous transplants in wound healing. In pharmacology, there is tremendous need for monitoring the response of engineered skin equivalents to external treatment. Transplantation of skin equivalents for wound healing requires careful verification of their quality prior to transplantation. Optical coherence tomography (OCT) is a non-contact, non-destructive imaging technique for living tissues offering the potential to fulfill these needs. This work presents an analysis of OCT for high-resolution monitoring of skin equivalents at different stages during the culture process. METHODS: We developed a high-resolution OCT imaging setup based on a commercially available OCT system. A broadband femtosecond laser light source replaces the original superluminescence diode. Tomograms of living skin equivalents were recorded with an axial resolution of 3 mum and correlated with histology and immunofluorescence images. Comparison with standard low-resolution OCT is presented to emphasize the advantages of high-resolution OCT for this application. RESULTS: OCT is particularly able to distinguish between different layers of skin equivalents including stratum corneum, epidermal and dermal layer as well as the basement membrane zone. The high-resolution OCT scans correlate closely with two key benchmarks, histology and immunofluorescence imaging. CONCLUSIONS: This study clearly demonstrates the benefits of high-resolution OCT for identifying living tissue structure and morphology. Compared with the current gold standard histology, OCT offers non-destructive tissue imaging, enabling high-resolution evaluation of living tissue morphology and structure as it evolves. 相似文献
OBJECTIVE: To establish reference intervals for the fetal right, left and total lung volumes and heart volume between 12 and 32 weeks of gestation. METHODS: Fetal lung and heart volumes were measured using three-dimensional (3D) ultrasound in 650 normal singleton pregnancies at 12-32 weeks. The VOCAL (Virtual Organ Computer-aided AnaLysis) technique was used to obtain a sequence of six sections of each lung and the heart around a fixed axis, each after a 30 degrees rotation from the previous one. The rotation axis for the lungs extended from the apex to the upper limit of the diaphragm dome, and the rotation axis for the heart extended from its apex to its connection to the great vessels. The contour of each of these organs was drawn manually in the six different rotation planes to obtain the 3D volume measurement. In 60 cases the fetal lungs and heart volumes were measured by the same sonographer twice and also by a second sonographer once in order to compare the measurements and calculate intra- and interobserver agreement. RESULTS: The total lung volume and heart volume increased with gestation, from respective mean values of 1.6 and 0.6 mL at 12 weeks to 10.9 and 4.3 mL at 20 weeks and 49.3 and 26.6 mL at 32 weeks. The right to left lung volume ratio did not change significantly with gestation (median, 0.7), whereas the heart to total lung volume ratio increased with gestation from about 0.3 at 12 weeks to 0.5 at 32 weeks. In the Bland-Altman plot, the difference between paired measurements by two sonographers was, in 95% of the cases, less than 0.05, 0.5 and 1.9 mL for each lung at 12-13, 19-22 and 29-32 weeks, respectively, and the corresponding values for the heart volumes were 0.04, 0.4 and 2.3 mL. CONCLUSIONS: In normal fetuses the lung and heart volumes increase between 12 and 32 weeks of gestation. The extent to which in pathological pregnancies possible deviations in these measurements from normal prove to be useful in the prediction of outcome remains to be determined. 相似文献