Summary We report a case of a male patient suffering from a severe hemorrhagic radiation proctitis which gradually ceased with hyperbaric oxygen. We discuss the mechanisms of chronic radiation injury and the effect of the hyperbaric oxygen. This therapy is proposed as an alternative to surgical intervention for this abnormality. 相似文献
Edrophonium, an anticholinesterase, exerts a biphasic effect on cardiovascular autonomic drive in humans (lower doses enhance; higher doses reduce). Twenty-five anesthetized, mechanically respired (10 breaths. min(-1), constant tidal volume) patients were given either saline (n = 10) or edrophonium (0.01-1.0 mg. kg(-1), n = 15) following surgery. ECG, radial arterial pressure, and respiratory rate were sampled at 250 Hz to obtain time series for consecutive R-R intervals (RRIs), and systolic (SBP) and diastolic blood pressure (DBP). A Wigner distribution was used for time frequency mapping of spectral powers at high (HFP, 0.15-0.5 Hz) and low (LFP, 0.0-0.05 Hz) frequency. Edrophonium produced a dose-dependent decrease in heart rate [baseline 66.8 +/- 1.9 (S.E.M.) beats per minute; maximum decrease to 55.8 +/- 1.4 beats per minute with 1.0 mg. kg(-1), P < 0.01]. HFP of the RRI increased at low doses (0.2-0.4 mg. kg(-1); maximum increase to 111.0 +/- 58.2% baseline; P < 0.01) but decreased (-49.5 +/- 35.5% baseline; P < 0.01) at higher (1.0 mg. kg(-1)) doses. Edrophonium had no effect on SBP and DBP. HFP of SBP decreased with increasing doses (maximal decrease to -26.2 +/- 7.5% baseline, P < 0.01, 1.0 mg. kg(-1)). LFP of SBP was also decreased (-46.3 +/- 10.9% baseline, P < 0.01, 1.0 mg. kg(-1)). Edrophonium may enhance (lower dose) or reduce (higher dose) cardiovascular autonomic drive in humans, as evidenced by the significant changes it evokes in HFP of the RRI (parasympathetic drive), and in the HFP and LFP of SBP (sympathetic drive). These observations may account for the modest autonomic side effects of edrophonium when this drug is used clinically. 相似文献
Background: Upper limb trauma occurs frequently in elderly patients for whom peripheral nerve blocks are often preferred for anesthesia. The characteristics of such regional blocks have, however, never been described in an elderly population. Therefore, the authors assessed prospectively the onset and duration of upper extremity peripheral nerve block (the mid-humeral block) in elderly and young patients undergoing emergency upper extremity surgery.
Methods: Consecutive patients aged > 70 yr or < 70 yr received a mid-humeral block with a small volume of ropivacaine, 0.75%. Five milliliters was injected onto each of the musculocutaneous, radial, ulnar, and median nerves. Time to complete sensory and motor block and durations of complete sensory and motor block were assessed. Results are shown as median and its 95% confidence interval.
Results: Median ages were 77 yr (95% CI, 72-81 yr) and 39 yr (95% CI, 27-46 yr) in the two groups. Both groups had similar times to complete sensory blockade. The elderly group had longer durations of complete sensory (390 min [range, 280-435 min]vs. 150 min [range, 105-160 min];P < 0.05) and motor (357 min [range, 270-475 min]vs. 150 min [range, 90-210 min];P < 0.05) blockade. Duration of complete sensory block was significantly correlated with age ([rho] = 0.56;P < 0.05). 相似文献
multicenter study was conducted to evaluate a new temporary caval filter (TempofilterT) designed to be implanted for up to 6 weeks. A total of 66 patients with a mean age of 51.8 years were enrolled in the study. All had documented high risk of pulmonary embolism: severe deep venous thrombosis in 89.5% of cases and previous symptomatic pulmonary embolism in 65% of cases. Filter placement was performed in association with a surgical or obstetrical procedure in 68.5% of cases. The indication for filter placement was contraindication to or failure of anticoagulant therapy in 85% of the cases. The mean duration of implantation was 29.9 days. Pulmonary embolism was not observed during the implantation period. Partial thrombosis of the filter was observed in 15% of cases due to trapping of clots by the filter. Thrombosis did not hinder filter removal when attempted. Filter-related complications were minor. Filter migration occurred in only 7.5% of cases. Migration never led to complications and did not hinder filter removal. In all cases migration was due to specific, preventable causes. The results of this study show that the TempofilterT is not only safe and easy to use but also effective in preventing pulmonary embolism. A significantly longer maximum implantation time is a major advantage of the TempofilterT over conventional temporary filters. We believe that this filter can be used for temporary protection against the risk of pulmonary embolism particularly in young patients and in a surgical setting. (Ann Vasc Surg 1997;11:520–528.) 相似文献
This study aimed to determine the effects of anti-CD154 on T cell cytokine profiles and ocular chemokine gene expression after high-risk corneal transplantation and to specifically determine if CD154 blockade is associated with a switch from a Th1 to a Th2 alloimmune response. Mice were used as recipients of syngeneic or multiple minor H or MHC antigen-mismatched corneal grafts. Recipient beds were neovascularized (high-risk). Hosts were randomized to receive either anti-CD154 antibody or control immunoglobulin (Ig) perioperatively. Two weeks after corneal transplantation, allospecific delayed-type hypersensitivity (DTH) was evaluated. Frequencies of interferon-gamma (IFN-gamma)-, interleukin-2 (IL-2)-, IL-4-, and IL-5-secreting T cells in the hosts were measured by enzyme-linked immunospot (ELISPOT) assay. Ocular chemokine gene expression in anti-CD154-treated and control hamster Ig-treated groups was determined using a multiprobe ribonuclease protection assay (RPA). Leukocyte infiltration of corneal grafts was evaluated microscopically. Anti-CD154-treated mice did not exhibit allospecific DTH. The frequencies of Th1 cytokine-producing but not Th2 cytokine-producing T cells were significantly reduced in anti-CD154-treated hosts. Postoperative mRNA levels of RANTES and macrophage inflammatory protein-1beta (MIP-1beta) in anti-CD154-treated eyes were substantially suppressed compared with hamster Ig-treated controls. Leukocyte infiltration was profoundly suppressed in grafts of anti-CD154-treated hosts. These data demonstrate that blockade of the CD40-CD154 costimulatory pathway after corneal transplantation inhibits Th1-mediated responses but does not induce a switch to a Th2-specific response. In addition, anti-CD154 therapy suppresses ocular chemokine gene expression and leukocytic infiltration into allografts. 相似文献
We studied blood pressure and natriuretic responses to acute salt loading,
and the effect of non-steroidal anti-inflammatory agents on these
responses, in five healthy normotensive women aged 65 to 71 years. Five
women aged 25 to 31 years acted as controls. Intravenous saline loading,
with and without prior ingestion of ibuprofen, was 15 ml/kg/h for 3 h.
Baseline blood pressures were higher in the elderly. Saline infusion
without ibuprofen raised systolic blood pressure (SBP) by about 25 mmHg in
the older group only. Ibuprofen increased baseline SBP in the elderly (129
+/- 6 vs. 116 +/- 5 mmHg, p < 0.05). Saline loading after ibuprofen
again raised blood pressure by about 25 mmHg in the elderly only. The
elderly group showed markedly increased sodium excretion during saline
loading, but this was reduced by ibuprofen. Ibuprofen had no effect on SBP
or sodium excretion in controls. Ageing appears to increase susceptibility
to salt retention and hypertension from non-steroidal anti-inflammatory
agents.
相似文献
PURPOSE: The gum elastic bougie (GEB) has been in use for a long time and allows tracheal intubation in most cases of difficult direct laryngoscopy. Use of the GEB when anatomical landmarks of the upper airway are not recognizable has not been reported. We describe our experience of airway management with the GEB in cases of severe upper airway distortion. CLINICAL FEATURES: Four patients with severe respiratory distress caused by upper airway distortion secondary to various non-malignant causes were managed with the GEB. For these four patients, a rapid sequence induction of anesthesia was performed with a surgeon present during the procedure. The GEB was used as the initial intubating technique in all cases and allowed a rapid and successful tracheal intubation in spite of non-recognizable anatomical structures. The distal hold-up feeling after GEB insertion confirmed, in all cases, the correct intratracheal position of the GEB. CONCLUSION: The GEB can be a valuable tool in cases of difficult airway management caused by upper airway distortion. The lack of visualization of normal pharyngeal structures did not prevent the successful insertion of the GEB in the trachea in the four patients reported. 相似文献