We have recently shown that human epididymis protein 4 (HE4) levels correlate with the severity of cystic fibrosis (CF) lung disease. However, there are no data on how HE4 levels alter in patients receiving CFTR modulating therapy.
Methods
In this retrospective clinical study, 3 independent CF patient cohorts (US-American: 29, Australian: 12 and Irish: 19 cases) were enrolled carrying at least one Class III CFTR CF-causing mutation (p.Gly551Asp) and being treated with CFTR potentiator ivacaftor. Plasma HE4 was measured by immunoassay before treatment (baseline) and 1–6?months after commencement of ivacaftor, and were correlated with FEV1 (% predicted), sweat chloride, C-reactive protein (CRP) and body mass index (BMI).
Results
After 1?month of therapy, HE4 levels were significantly lower than at baseline and remained decreased up to 6?months. A significant inverse correlation between absolute and delta values of HE4 and FEV1 (r?=??0.5376; P?<?.001 and r?=??0.3285; P?<?.001), was retrospectively observed in pooled groups, including an independent association of HE4 with FEV1 by multiple regression analysis (β?=??0.57, P?=?.019). Substantial area under the receiver operating characteristic curve (ROC-AUC) value was determined for HE4 when 7% mean change of FEV1 (0.722 [95% CI 0.581–0.863]; P?=?.029) were used as classifier, especially in the first 2?months of treatment (0.806 [95% CI 0.665–0.947]; P?<?.001).
Conclusions
This study shows that plasma HE4 levels inversely correlate with lung function improvement in CF patients receiving ivacaftor. Overall, this potential biomarker may be of value for routine clinical and laboratory follow-up of CFTR modulating therapy. 相似文献
ObjectivesSevere acute kidney injury (AKI) is a known risk factor for infection and mortality. However, whether stage 1 AKI is a risk factor for infection has not been evaluated in adults. We hypothesized that stage 1 AKI following cardiac surgery would independently associate with infection and mortality.MethodsIn this retrospective propensity score–matched study, we evaluated 1620 adult patients who underwent nonemergent cardiac surgery at the University of Colorado Hospital from 2011 to 2017. Patients who developed stage 1 AKI by Kidney Disease Improving Global Outcomes creatinine criteria within 72 hours of surgery were matched to patients who did not develop AKI. The primary outcome was an infection, defined as a new surgical-site infection, positive blood or urine culture, or development of pneumonia. Secondary outcomes included in-hospital mortality, stroke, and intensive care unit (ICU) and hospital length of stay (LOS).ResultsStage 1 AKI occurred in 293 patients (18.3%). Infection occurred in 20.9% of patients with stage 1 AKI compared with 8.1% in the no-AKI group (P < .001). In propensity-score matched analysis, stage 1 AKI independently associated with increased infection (odds ratio [OR]; 2.24, 95% confidence interval [CI], 1.37-3.17), ICU LOS (OR, 2.38; 95% CI, 1.71–3.31), and hospital LOS (OR, 1.30; 95% CI, 1.17-1.45).ConclusionsStage 1 AKI is independently associated with postoperative infection, ICU LOS, and hospital LOS. Treatment strategies focused on prevention, early recognition, and optimal medical management of AKI may decrease significant postoperative morbidity. 相似文献
Background: While over half of stroke survivors recover the ability to walk without assistance, deficits persist in the performance of walking adaptations necessary for safe home and community mobility. One such adaptation is the ability to walk or step backward. Post-stroke rehabilitation rarely includes backward walking (BW) assessment and BW deficits have not been quantified in post-stroke community ambulators.
Objective: To quantify spatiotemporal and kinematic BW characteristics in post-stroke community ambulators and compare their performance to controls.
Methods: Individuals post-stroke (n = 15, 60.1 ± 12.9 years, forward speed: 1.13 ± 0.23 m/s) and healthy adults (n = 12, 61.2 ± 16.2 years, forward speed: 1.40 ± 0.13 m/s) performed forward walking (FW) and BW during a single session. Step characteristics and peak lower extremity joint angles were extracted using 3D motion analysis and analyzed with mixed-method ANOVAs (group, walking condition).
Results: The stroke group demonstrated greater reductions in speed, step length and cadence and a greater increase in double-support time during BW compared to FW (p < .01). Compared to FW, the post-stroke group demonstrated greater reductions in hip extension and knee flexion during BW (p < .05). The control group demonstrated decreased plantarflexion and increased dorsiflexion during BW, but these increases were attenuated in the post-stroke group (p < .05).
Conclusions: Assessment of BW can unmask post-stroke walking impairments not detected during typical FW. BW impairments may contribute to the mobility difficulties reported by adults post-stroke. Therefore, BW should be assessed when determining readiness for home and community ambulation. 相似文献
We investigated the effects of the noble gas argon on the expression of locomotor sensitization to amphetamine and amphetamine-induced changes in dopamine release and mu-opioid neurotransmission in the nucleus accumbens. We found (1) argon blocked the increase in carrier-mediated dopamine release induced by amphetamine in brain slices, but, in contrast, potentiated the decrease in KCl-evoked dopamine release induced by amphetamine, thereby suggesting that argon inhibited the vesicular monoamine transporter-2; (2) argon blocked the expression of locomotor and mu-opioid neurotransmission sensitization induced by repeated amphetamine administration in a short-term model of sensitization in rats; (3) argon decreased the maximal number of binding sites and increased the dissociation constant of mu-receptors in membrane preparations, thereby indicating that argon is a mu-receptor antagonist; (4) argon blocked the expression of locomotor sensitization and context-dependent locomotor activity induced by repeated administration of amphetamine in a long-term model of sensitization. Taken together, these data indicate that argon could be of potential interest for treating drug addiction and dependence. 相似文献
AbstractThe occupational hazards and respiratory symptoms of domestic cleaners in USA are largely unknown. We conducted a cross-sectional study among 56 Hispanic female domestic cleaner on their health status and frequency of cleaning products used and tasks performed. While women used multi-use products (60.0%) and toilet bowl cleaners (51.8%) most days of the week, many (39.3%) reported not using personal protective equipment while cleaning. Itchy/watery eyes (61.8%) and itchy nose (56.4%) were the most frequently reported symptoms. A history of physician-diagnosed asthma was reported by 14.3% while 33.9% had symptoms of bronchial hyperresponsiveness (BHR). In conclusion, this vulnerable population has high prevalence of physician-diagnosis asthma and BHR symptoms and is potentially exposed to myriad occupational hazards. Further research exploring associations between products use, cleaning tasks and respiratory symptoms is warranted. 相似文献
We used the dual capability of hyperpolarized 129Xe for spectroscopy and imaging to develop new measures of xenon diffusing capacity in the rat lung that (analogously to the diffusing capacity of carbon monoxide or DLCO) are calculated as a product of total lung volume and gas transfer rate constants divided by the pressure gradient. Under conditions of known constant pressure breath-hold, the volume is measured by hyperpolarized 129Xe MRI, and the transfer rate is measured by dynamic spectroscopy. The new quantities (xenon diffusing capacity in lung parenchyma (DLXeLP)), xenon diffusing capacity in RBCs (DLXeRBC), and total lung xenon diffusing capacity (DLXe)) were measured in six normal rats and six rats with lung inflammation induced by instillation of fungal spores of Stachybotrys chartarum. DLXeLP, DLXeRBC, and DLXe were 56 +/- 10 ml/min/mmHg, 64 +/- 35 ml/min/mmHg, and 29 +/- 9 ml/min/mmHg, respectively, for normal rats, and 27 +/- 9 ml/min/mmHg, 42 +/- 27 ml/min/mmHg, and 16 +/- 7 ml/min/mmHg, respectively, for diseased rats. Lung volumes and gas transfer times for LP (TtrLP) were 16 +/- 2 ml and 22 +/- 3 ms, respectively, for normal rats and 12 +/- 2 ml and 35 +/- 8 ms, respectively, for diseased rats. Xenon diffusing capacities may be useful for measuring changes in gas exchange associated with inflammation and other lung diseases. 相似文献
OBJECTIVE: A series of nasopharyngeal appliance designs is presented that represents our evolving experience over a 20-year period in the adjunctive use of prosthetic stents in the surgical correction of nasopharyngeal stenosis. DESIGN: Retrospective assessment of effectiveness of two nasopharyngeal stenosis hollow stent designs in a consecutive series of patients for relief of nasal obstructive symptoms. SETTING: Tertiary academic medical center, Craniofacial Program at Children's Hospital. PATIENTS: Four patients with nasopharyngeal stenosis were treated with a preoperatively fabricated stent made from a clasped palatal appliance onto which hollow acrylic conduits were extended through surgically re-created pharyngeal ports. A subsequent set of four patients with nasopharyngeal stenosis were treated with intraoperatively-fashioned silastic grommets, as opposed to palatal appliances. INTERVENTIONS: Postoperative intraoral stenting of nasopharyngeal ports. MAIN OUTCOME MEASURES: Maintenance of pharyngeal port opening after 1 year, improvement in nasal airway obstructive symptoms. RESULTS: The palatal appliance stents were less well tolerated and had a lower maintenance of port patency after device removal (4 of 8, 50%). The silastic grommets provided better retention into the ports and increased patient tolerance, as well as better 1-year port maintenance (6 of 8, 75%). CONCLUSIONS: The grommet stent appliance offers numerous advantages over a conventional dental-clasped appliance for prosthetic nasopharyngeal stenting, including obviation of extensive preoperative preparation, ease of insertion and removal, and exchange of air during the stenting period. Improved nasopharyngeal patency with this device may be due to greater patient tolerance and subsequent longer use. 相似文献