BACKGROUND: The aim of this study was to estimate the cost effectiveness of screening for abdominal aortic aneurysm (AAA). MATERIAL AND METHODS: All 12,639 men born in the years 1921-1933 (aged 64-73) living in Viborg County, Denmark, were randomly allocated either to receive an invitation to abdominal ultrasound scanning for AAA or to be controls. Costs for screening and surveillance were assessed prospectively. Diagnosis Related Group (DRG) costs from 1999 were used concerning admissions with uncomplicated and complicated operations. Admissions for AAA surgery were retrospectively classified according to complications in patient records. RESULTS: Mean follow-up time was 52 months. 76.6% of invited men attended screening, and 191 (4.0%) had an AAA. As previously reported, the cumulative 5-year AAA-specific mortality in the invited group was significantly reduced by 67% compared to the control group (P = 0.003). The costs were estimated to be Euro 11.23 per scan. The costs per life-year saved were Euro 9057 (Euro 5872-20,063) after 5 years, and were expected to decrease to Euro 2708 (Euro 1758-6031) after 10 years and to Euro 1825 (Euro 1185-4063) after 15 years. CONCLUSION: Screening of 64-73 years old males in Denmark seems cost effective. 相似文献
Background: Few studies have examined the use of ultrasound for sciatic nerve localization. The authors evaluated the usefulness of low-frequency ultrasound in identifying the sciatic nerve at three locations in the lower extremity and in guiding needle advancement to target before nerve stimulation.
Methods: In this prospective observational study, 15 volunteers underwent sciatic nerve examination using a curved ultrasound probe in the range of 2-5 MHz and a Philips-ATL 5000 unit (ATL Ultrasound, Bothell, WA) in the gluteal, infragluteal, and proximal thigh regions. Thereafter, an insulated block needle was advanced inline with the ultrasound beam to reach the nerve target, which was further confirmed by electrical stimulation. The quality of sciatic nerve images, ease of needle to nerve contact, threshold stimulating current, and resultant motor response were recorded.
Results: The sciatic nerve was successfully identified in the transverse view as a solitary predominantly hyperechoic structure on ultrasound in all of the three regions examined. The target nerve was visualized easily in 87% and localized within two needle attempts in all patients. Nerve stimulation was successful in 100% after two attempts with a threshold current of 0.42 +/- 0.12 (mean +/- SD) eliciting foot plantarflexion or dorsiflexion. 相似文献
Abstract: Background: Fetal pulse oximetry improves the assessment of fetal well‐being during labor. The objective of this study was to evaluate women's satisfaction with their experience with this additional technology. Methods: We surveyed women participating in the FOREMOST trial, a randomized controlled trial comparing the addition of fetal pulse oximetry (FPO) to conventional cardiotocograph (CTG) monitoring (intervention group), versus CTG‐only (control group), in the presence of nonreassuring fetal status during labor. Our survey evaluated 3 aspects of women's experience: labor, fetal monitoring, and participation in the research. The survey was administered within a few days of giving birth and repeated 3 months later. Results: No differences were found between the intervention and control groups for women's evaluations of their labor, fetal monitoring, research, or overall experiences when surveyed on both occasions. Within each study group, a small but statistically significant decline occurred in women's scores for their experience of labor and overall experience from the initial survey close to the time of giving birth, to 3 months later. The magnitude of differences in responses over time was similar for the both groups. Women were more satisfied after a spontaneous or assisted vaginal birth than after cesarean section. Length of time the research midwife was present had a significant positive effect on women's ratings of their experience several days after giving birth (p = 0.006), but no effect at 3 months. Conclusions: The addition of fetal pulse oximetry for the assessment of fetal well‐being during labor did not affect childbearing women's perceptions of fetal monitoring or their labor. Women evaluated their experience in the research process positively overall. Small changes occurred in women's perception of their satisfaction over time. (BIRTH 33:2 June 2006)相似文献
BACKGROUND: Three dimensional skin equivalents are widely used in dermatopharmacological and toxicological studies and as autologous transplants in wound healing. In pharmacology, there is tremendous need for monitoring the response of engineered skin equivalents to external treatment. Transplantation of skin equivalents for wound healing requires careful verification of their quality prior to transplantation. Optical coherence tomography (OCT) is a non-contact, non-destructive imaging technique for living tissues offering the potential to fulfill these needs. This work presents an analysis of OCT for high-resolution monitoring of skin equivalents at different stages during the culture process. METHODS: We developed a high-resolution OCT imaging setup based on a commercially available OCT system. A broadband femtosecond laser light source replaces the original superluminescence diode. Tomograms of living skin equivalents were recorded with an axial resolution of 3 mum and correlated with histology and immunofluorescence images. Comparison with standard low-resolution OCT is presented to emphasize the advantages of high-resolution OCT for this application. RESULTS: OCT is particularly able to distinguish between different layers of skin equivalents including stratum corneum, epidermal and dermal layer as well as the basement membrane zone. The high-resolution OCT scans correlate closely with two key benchmarks, histology and immunofluorescence imaging. CONCLUSIONS: This study clearly demonstrates the benefits of high-resolution OCT for identifying living tissue structure and morphology. Compared with the current gold standard histology, OCT offers non-destructive tissue imaging, enabling high-resolution evaluation of living tissue morphology and structure as it evolves. 相似文献
OBJECTIVE: To establish reference intervals for the fetal right, left and total lung volumes and heart volume between 12 and 32 weeks of gestation. METHODS: Fetal lung and heart volumes were measured using three-dimensional (3D) ultrasound in 650 normal singleton pregnancies at 12-32 weeks. The VOCAL (Virtual Organ Computer-aided AnaLysis) technique was used to obtain a sequence of six sections of each lung and the heart around a fixed axis, each after a 30 degrees rotation from the previous one. The rotation axis for the lungs extended from the apex to the upper limit of the diaphragm dome, and the rotation axis for the heart extended from its apex to its connection to the great vessels. The contour of each of these organs was drawn manually in the six different rotation planes to obtain the 3D volume measurement. In 60 cases the fetal lungs and heart volumes were measured by the same sonographer twice and also by a second sonographer once in order to compare the measurements and calculate intra- and interobserver agreement. RESULTS: The total lung volume and heart volume increased with gestation, from respective mean values of 1.6 and 0.6 mL at 12 weeks to 10.9 and 4.3 mL at 20 weeks and 49.3 and 26.6 mL at 32 weeks. The right to left lung volume ratio did not change significantly with gestation (median, 0.7), whereas the heart to total lung volume ratio increased with gestation from about 0.3 at 12 weeks to 0.5 at 32 weeks. In the Bland-Altman plot, the difference between paired measurements by two sonographers was, in 95% of the cases, less than 0.05, 0.5 and 1.9 mL for each lung at 12-13, 19-22 and 29-32 weeks, respectively, and the corresponding values for the heart volumes were 0.04, 0.4 and 2.3 mL. CONCLUSIONS: In normal fetuses the lung and heart volumes increase between 12 and 32 weeks of gestation. The extent to which in pathological pregnancies possible deviations in these measurements from normal prove to be useful in the prediction of outcome remains to be determined. 相似文献
OBJECTIVE: To explore the impact of timing and type of ultrasound, particularly three-dimensional (3D), exposure on maternal-fetal attachment and maternal health behavior during pregnancy. METHODS: Subjects were 68 women aged 18 years or older expecting their first child who presented for a routine ultrasound scan at around either 12 or 18 weeks' gestation in Nepean Hospital, Western Sydney. Women completed questionnaires assessing maternal-fetal attachment and health behavior, and were then allocated arbitrarily to either two-dimensional (2D) or 3D ultrasound examination. Repeat questionnaires were completed 1 week later. RESULTS: Maternal-fetal attachment increased after both 2D and 3D ultrasound exposure, and the effect was moderated by the timing of exposure, with women receiving their first ultrasound examination at around 12 weeks showing the greatest change. Alcohol consumption was the only behavior to show significant change following ultrasound exposure, with a reduction in the reported average number of drinks per week. There was no significant difference in the pattern of change for 2D compared with 3D ultrasound exposure, and no effect of ultrasound exposure on maternal perception of the fetus. CONCLUSIONS: Ultrasound has a positive impact on maternal-fetal attachment, particularly in the first trimester. 3D ultrasound did not offer enhanced benefits. Associations between ultrasound exposure and alcohol consumption warrant further investigation. Larger samples are needed to clarify the moderating effects of gestational age and type of ultrasound exposure. 相似文献