OBJECTIVE: The study was designed to test application of ultraviolet light to root canal walls, as a mean of complementary immediate disinfection after the use of sodium hypochlorite. STUDY DESIGN: Root canals were infected ex vivo with Enterococcus faecalis for 48 hours. Non-attached bacteria were washed away, and the remaining attached bacteria were subjected to disinfection, with 5% sodium hypochlorite alone or followed by exposure to ultraviolet light (254 nm, 300 mJ/cm(2)). Root canals were then tested for remaining viable bacteria. Canals were obturated and tested again after 14 days. RESULTS: Sodium hypochlorite alone achieved negative cultures in only 47% of the cases, but 96% was achieved with sodium hypochlorite followed by ultraviolet light (P < .001). This status was also maintained after 14 days. CONCLUSIONS: Illumination of root canals with ultraviolet light may be an effective supplementary means to achieve immediate disinfection of infected root canals. 相似文献
Objectives: The purpose of this study was to determine if a device placed externally around the aortic root decreases regurgitant flow in acute aortic regurgitation. Background: Aortic regurgitant flow is dependent on central aortic pressure and the aortic root and leaflet geometry. It may be possible to decrease aortic regurgitant severity by reducing aortic root size or dimension changes. Methods: Aortic regurgitation was created in eight calf heart specimens suspended in a continuous flow system. Retrograde and antegrade aortic flow and distending aortic pressure were measured at baseline and after placement of an external aortic device at the level of the aortic annulus. In two additional specimens, the incompetent aortic valve was visualized fiberoptically before and after placement of the external device. Acute aortic regurgitation was created surgically in four live calves by excising a portion of the aortic leaflets. Antegrade and retrograde flow, left ventricular pressure, and central aortic pressure were measured at baseline, after creation of aortic regurgitation, and after placement of the external device. Results: In the in vitro calf specimens, regurgitant flow decreased from 46.9 cc/sec to 15.1 cc/sec (66.0%± 21.8% decrease) after placement of the external device (p < 0.001). The regurgitant orifice area decreased from 0.13 ± 0.04 cm2 to 0.04 ± 0.02 cm2 after device placement (p < 0.001). Antegrade flow was reduced to a smaller extent (20.0%± 19.2% decrease) by the device (p < 0.05). Placement of the device around the aorta resulted in improved coaptation of the leaflets with a marked reduction in defect size by endoscopic visualization. Use of the external aortic device was associated with improvement in aortic regurgitant severity in three of four calves with surgically created aortic regurgitation. Concluslons: In these preliminary studies, acute experimental aortic regurgitant severity is decreased by the use of an external aortic device, probably due to reduction in aortic annular dimension changes and improved aortic leaflet apposition. Further studies are needed to determine the effectiveness of this device in chronic aortic regurgitation. (J Card Surg 1994;9:304–313) 相似文献
This study investigated relationships between child/parent dissatisfaction with child facial appearance and the self-concept/social competence of 8- to 15-year-old children with (N = 34) and without (N = 34) oral clefts. Children in both groups had normative psychosocial adjustment, but also reported moderate dissatisfaction with facial appearance. Cleft group parents were more likely to agree with their child's dissatisfaction. When cleft group parents were more dissatisfied with child facial appearance, their children reported better quality of life. Results suggest that parents of children with clefts reporting greater dissatisfaction may respond in positive ways that enhance quality of life. 相似文献
OBJECTIVE: To determine if differences in balance and recovery would be found between controls and participants with unilateral or bilateral functional ankle instability (FAI). DESIGN: Cross-Sectional Study. SETTING: University laboratory and Community premises. PARTICIPANTS: Twenty healthy participants(C), 19 participants with unilateral FAI [both the uninjured (UC) and unstable ankle (UI) were included] and 22 participants with bilateral FAI (BI). MAIN OUTCOME MEASURES: Balance was measured in single leg stance as: number of part foot lifts in 30 s; magnitude of medio-lateral ankle movement in two foot positions; and ability to balance on the ball of the foot. Recovery was determined by time to return to baseline medio-lateral ankle movement after a 15 degree inversion perturbation. RESULTS: The controls lifted the foot fewer times than the other three groups [C = 12.7 +/- 1.8 (mean +/- SE) foot lifts, UC = 22.9 +/- 2.5, UI = 25.1 +/- 2.3, and BI = 21.1 +/- 2.2, t-test, P = 0.006] and recovered significantly faster than the unstable ankles [C = 1.53 +/- 0.42 sec (median +/- SE), UI = 2.34 +/- 0.30 sec, BI = 2.15 +/- 0.70 sec, P < 0.02]. With FAI measured by the Cumberland Ankle Instability Tool, the external control group balanced on demi-pointe better than both instability groups (P < 0.05), and recovered quicker than all groups. CONCLUSION: There are differences in balance and recovery between external controls and participants with both unilateral and bilateral FAI but not between the legs of participants with unilateral FAI. 相似文献
Background: Biphasic waveform shocks are more effective than monophasic shocks for transchest ventricular defibrillation, atrial cardioversion, and defibrillation with implantable defibrillators but have not been studied for open chest, intraoperative defibrillation. This prospective, blinded, randomized clinical study compares biphasic and monophasic shock effectiveness and establishes intraoperative energy dose-response curves.
Methods: Patients undergoing cardiothoracic surgery with bypass cardioplegia were randomly assigned to the monophasic or biphasic shock group. Ventricular fibrillation occurring after aortic clamp removal was treated with escalating energies of 2, 5, 7, 10, and 20 J until defibrillation occurred. If ventricular fibrillation persisted, a 20-J crossover shock of the other waveform was used.
Results: Cumulative defibrillation success at 5 J, the primary end point of the study, was higher in the biphasic group than in the monophasic group (25 of 50 vs. 9 of 41 defibrillated;P = 0.011). In addition, the biphasic group required lower threshold energy (6.8 vs. 11.0 J;P = 0.003), less cumulative energy (12.6 vs. 23.4 J;P = 0.002), and fewer shocks (2.5 vs. 3.5;P = 0.002). Crossover-shock effectiveness did not differ between groups. Dose-response curves show biphasic shocks to have higher cumulative success rates at all energies tested. 相似文献