Rheumatoid arthritis (RA) patients have increased mortality largely as a result of cardiovascular diseases (CVD) that cannot
be explained by traditional risk factors, suggesting that systemic inflammation may accelerate atherosclerosis. We investigated
the presence of subclinical atherosclerosis in early RA (<12 months) and the possible association of RA-related risk factors.
Forty patients with early RA and 40 controls matched for age, sex, and traditional risk factors for CVD were selected. Carotid
US examination, assay of lipogram, C-reactive protein (CRP), and oxidized low-density lipoprotein antibodies (OxLDL-ab) were
done. RA patients had significantly higher carotid intima-media thickness (cIMT) values and more plaque than the control (P < 0.001 and P = 0.0122, respectively). CRP and OxLDL-ab were significantly higher in RA patients than controls. Traditional risk factors
and RA-related risk factors (disease duration, DAS-28, duration of treatment with steroids, erythrocyte sedimentation rate,
and CRP) as well as OxLDL and cIMT were significantly higher in RA with plaques compared to those without plaques. Regression
analysis identified the age of patients, CRP, and OxLDL-ab as an independent risk factor associated with the presence of atherosclerosis.
Conclusion: there is increased prevalence of carotid plaques in patients with recent-onset RA compared to matched controls.
The accelerated atherosclerosis is predicted by age, CRP, and oxLDL-ab. The association of plaques with elevated CRP and OxLDL-ab
support the hypothesis that chronic systemic autoimmune inflammatory process is probably a driving force for premature atherosclerosis. 相似文献
We propose an approach to supporting pre-surgical planning for the uterus by integrating medical image analysis and physical model generation based on 3D printing. With our method, we first segment the patient-specific anatomy and lesions of the uterus on MR images; then, we create a 3D physical model, an exact replica of the patient’s uterus in terms of size and softness, with transparency for easy observation of the internal structures of the uterus. In our experiments, we created pre-surgical models of hysterectomy for five patients who had been diagnosed to have uterine endometrial cancer. An experienced radiologist, the surgeons, and all of the patients cooperated in our experiment for carrying out subjective evaluations of the usefulness of our model. The accuracy of the physical models was evaluated quantitatively by comparison between the MR images of the patients and the CT images of the models. The results showed that the mean values of the errors in gap ranged from 1.19 to 2.22 mm, which was satisfactory for the surgeons. The feedback from both surgeons and patients demonstrated the usefulness and convenience of the models for efficient patient explanation understanding and pre-surgical planning by surgeons. 相似文献
BACKGROUND: Colonoscopy preparation regimens are often poorly tolerated because they require use of large-volume bowel preparation solution and diet restrictions for adequate cleansing. This study evaluated the efficacy and tolerability of a split-dose polyethylene glycol-electrolyte solution plus bisacodyl and a regular diet. METHODS: A total of 187 patients (104 men, 83 women; age range 18-91 years) were randomly assigned to receive either 3 L of polyethylene glycol-electrolyte solution (n = 96; Group A) with a liquid diet on the day before colonoscopy, or 2 L of polyethylene glycol-electrolyte solution, one tablet of bisacodyl, and a minimally restricted diet on the day before colonoscopy, and then 1 L of the same solution on the day of colonoscopy (n = 91; Group B). Acceptability, adverse events, and willingness to retake the preparation were assessed by questionnaire. The quality of the preparation was graded by an endoscopist, blinded to the type of preparation, by using a previously described scale (excellent to poor). RESULTS: There were 96 patients in Group A and 91 in Group B. Colon cleansing was significantly better in Group B with regard to the overall quality of the preparation (p lt; 0.05). Compliance was significantly higher in Group B as evidenced by the lower number of patients who discontinued the preparation (4 vs. 15; p = 0.02) because of side effects such as nausea or vomiting. The degree of discomfort, adverse events, and willingness to retake the preparation were not significantly different between the groups. CONCLUSIONS: Colonic preparation with split-dose polyethylene glycol-electrolyte provided better quality colon cleansing and higher compliance, with less dietary restrictions, than preparation with whole-dose polyethylene glycol-electrolyte. 相似文献
Hepatitis C virus (HCV) is the leading cause of chronic liver disease worldwide with a prevalence of approximately 14% in Egypt. IL-10 is a cytokine produced by Th2 cells. It down-regulates the proinflammatory response and modulates hepatic fibrogenesis. IL-12 is produced by antigen presenting cells. It promotes Th1 cell response and has many antiviral properties. Data concerning the Th-1/Th-2 balance in chronic hepatitis C (CH-C) are rather conflicting. Using ELISA, we assessed serum IL-10 and IL-12p40 levels in 66 Egyptian patients with HCV-related liver illness (CH-C, cirrhosis, and HCC), and their relationship to disease activity. Our results showed that spontaneous IL-10 was undetectable in patients with CH-C, HCC or controls. Only 5/22 (23%) of patients with cirrhosis showed detectable levels of IL-10. IL-12p40 was elevated in the patient groups compared to controls (p= 0.01, p= 0.01, p= 0.05 in CH-C, cirrhosis and HCC, respectively). The presence of IL-12p40 was associated with HCV level of viremia and serum AST. Serum ALT level was significantly associated with the level of IL-12p40. IL-12p40 was unrelated to liver histology or fibrosis. We concluded that in the Egyptian patients an augmentation of IL-12p40 and a suppression of IL-10 are both found. Whether this pattern is related to HCV genotype 4, or to the presence of schistosomiasis would need to be further investigated. 相似文献
The Centers for Medicare and Medicaid Services (CMS) model for publicly reporting national 30-day-risk-adjusted mortality rates for patients admitted with heart failure fails to include clinical variables known to impact total mortality or take into consideration the culture of end-of-life care. We sought to determine if those variables were related to the 30-day mortality of heart failure patients at Geisinger Medical Center.
Methods
Electronic records were searched for patients with a diagnosis of heart failure who died from any cause during hospitalization or within 30 days of admission.
Results
There were 646 heart-failure-related admissions among 530 patients (1.2 admissions/patient). Sixty-seven of the 530 (13%) patients died: 35 (52%) died during their hospitalization and 32 (48%) died after discharge but within 30 days of admission; of these, 27 (40%) had been transferred in for higher-acuity care. Fifty-one (76%) died from heart failure, and 16 (24%) from other causes. Fifty-five (82%) patients were classified as American Heart Association Stage D, 58 (87%) as New York Heart Association Class IV, and 30 (45%) had right-ventricular systolic dysfunction. None of the 32 patients who died after discharge met recommendations for beta-blockers. Criteria for prescribing angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, and mineralocorticoid receptor blockers were not met by 33 of the 34 patients (97%) with heart failure with reduced ejection fraction not on one of those drugs. Fifty-seven patients (85%) had a do-not-resuscitate (DNR) status.
Conclusion
A majority of heart failure-related mortality was among patients who opted for a DNR status with end-stage heart failure, limiting the appropriateness of administering evidence-based therapies. No care gaps were identified that contributed to mortality at our institution. The CMS 30-day model fails to take important variables into consideration. 相似文献
Objective: To assess the effect of prophylactic corticosteroids administration at 37 weeks before term elective cesarean section (CS) in reducing neonatal respiratory morbidity and admission to neonatal intensive care unit (NICU).
Methods: This randomized trial was conducted focusing on women subjected to term elective CS. Women who were eligible for the study were divided into two groups. At 37 weeks' gestation; study group received two intramuscular doses of 12?mg dexamethasone 24?h apart, while the control group given the usual care without steroids. Outcome measures were adverse neonatal respiratory outcomes (respiratory distress syndrome (RDS) and transient tachypnea of the newborn (TTN)) and rates of admission to NICU.
Results: Neonates in the treatment group had lower overall incidence of respiratory distress morbidity 7.9% versus 23% when compared to the control group. The main morbidity was TTN (7% in study versus 19.6% in control group). There was significantly lower incidence of both mild and moderate degrees of respiratory distress in the study group (7 and 0.9%, respectively) compared to 17 and 5.3% in the control group. The most significant benefit of steroid administration was noted in those babies 37–37+6 weeks.
Conclusion: Antenatal administration of steroids at 37 weeks appears to be beneficial in reducing neonatal respiratory morbidity in women undergoing elective term CS. 相似文献
Two simple, sensitive, and rapid spectrofluorimetric methods were developed and validated for the determination of albendazole. The first method (method I) was based on the quenching effect of albendazole on the native fluorescence of erythrosine B. The fluorescence intensity was measured at 554 nm after extraction at 527 nm. In the second method (method II) the drug was reacted with lanthanum(iii) ions to form a metal complex, which was measured at 340 nm after excitation at 295 nm. The suitable pH was 3.4 (Teorell–Stenhagen buffer) and pH 5.5 (phosphate buffer solution), for method I and II, respectively. The influence of experimental factors on the fluorescence intensity of the reaction products was investigated and optimized. The linear concentration ranges were 0.2–3.5 and 0.06–0.90 μg mL−1, with detection limits of 0.049 and 0.019 μg mL−1 for method I and II, respectively. ICH guidelines were followed for validation of the developed procedures, and the results were acceptable. The Gibb''s free energy change of the reactions was −24.6 and −27.5 kJ mol−1 for method I and II, respectively. These negative values indicated the high feasibility of these reactions at ambient temperature. The proposed procedures were applied successfully for the determination of albendazole in commercial dosage forms and spiked human plasma. The results showed high precision, accuracy and recovery of the reported methods without any significant interference from pharmaceutical excipients or plasma components.Complexation of albendazole with erythrosine B quench the native fluorescence of the dye while complexation of the drug with lanthanum (iii) ions enhance the fluorescence of the drug. 相似文献