The purpose of this study was to determine whether blood lipid and lipoprotein concentrations varied in 5 men with advanced HIV-1 infection after 12 months of aerobic exercise training. Prior to exercise, the mean baseline cholesterol and high-density lipoprotein cholesterol (HDL-C) serum concentration were each lower, and mean baseline triglyceride concentration was higher compared to a healthy population norm. Consistent exercise training for 12 months failed to significantly (p > .05) alter cholesterol or HDL-C. Triglyceride concentration was significantly (p < .05) elevated above baseline (63 mg/dL) regardless of exercise compliance. The results suggest that long-term exercise training cannot correct lipid profile abnormality, particularly hypertriglyceridemia, common to individuals with advanced HIV-1 infection. 相似文献
The substitution of leucine for valine at amino acid position 34 of the factor XIII gene is commonly referred to as FXIII Val34Leu polymorphism. The homozygous leucine/leucine genotype has been reported to confer protection against venous thromboembolism, but previous studies have not evaluated a population limited to those with idiopathic venous thromboembolism. The primary objective of the study was to determine whether the FXIII Val34Leu polymorphism is independently associated with the occurrence of idiopathic venous thromboembolism. We prospectively enrolled consecutive patients with at least one objectively confirmed idiopathic venous thromboembolism. Friends of cases were recruited as controls and matched to cases by sex, ethnicity, and age. All participants were tested for the FXIII Val34Leu polymorphism in addition to several well-known thrombophilias. Data from 309 cases and 306 controls were analyzed. The FXIII leucine/leucine genotype was present in 4.9% of cases and 6.5% of controls. An adjusted odds ratio of 0.59 (95% confidence interval, 0.25-1.38) was found for the recessive model and 0.69 (95% confidence interval, 0.46-1.02) for the dominant model. Our results do not support an independent association of the FXIII Val34Leu polymorphism with idiopathic venous thromboembolism in our Caucasian Canadian study population. 相似文献
We selected a group of male dialysis patients complaining of sexual dysfunction in whom penile vascular insufficiency and drug-induced impotence had been excluded. Monitoring of nocturnal penile tumescence was used to confirm organic disturbance. Patients with normal serum prolactin concentrations (n = 18) had significantly lower serum zinc values than normal controls (P less than 0.001) and were entered in a 6-month double-blind study comparing oral zinc acetate with placebo. Patients with elevated prolactin concentrations (n = 8) were entered in a 3-month double-blind crossover study comparing oral pergolide mesylate with placebo. In the zinc study, serum zinc concentrations increased (P less than 0.05) in the zinc-treated but not the placebo-treated group. One of nine patients receiving zinc reported improved sexual function, as did two of nine patients receiving placebo. There were no significant changes in sperm counts, nocturnal penile tumescence, testosterone, sex hormone binding globulin or gonadotrophin concentrations in either treatment group. In the pergolide study, serum prolactin values decreased (P less than 0.01) in the pergolide but not in the placebo treatment period. One patient reported improved sexual function during the pergolide treatment period and two during the placebo period. There were no significant changes in sperm counts, nocturnal penile tumescence, testosterone, sex hormone binding globulin or gonadotrophin concentrations after pergolide. These studies show no benefit of zinc or pergolide compared with placebo in the treatment of uraemic impotence. 相似文献
Summary Infrared computed stroboscopic photometry was used to quantify the kinematic profiles of walking in 10 elderly patients with symmetrical neurological disturbances of gait and in 19 age-matched neurologically healthy people. Clinical examination of the patients revealed similar profiles of walking even though their diagnoses were vascular dementia (2), normal pressure hydrocephalus (2), Alzheimer dementia with possible normal pressure hydrocephalus (2), mixed Alzheimer and vascular dementia (1), peripheral neuropathy (1), Alzheimer dementia with parkinsonian features (1), and un determined (1). Quantitatively, the patients' gait kinematics deviated greatly from control values, but these deviations were statistically attributable to reductions in stride. We suggest that many gait disturbances in elderly people are similar, regardless of etiology, because the characteristics of these gait disturbances are heavily veiled by nonspecific stride-dependent changes that comprise the syndrome of senile gait. 相似文献
Background: The effects of epidural needle design, angle, and bevel orientation on cerebrospinal fluid leak after puncture have not been reported. The impact of these factors on leak rate was examined using a dural sac model. Dural trauma was examined using scanning electron microscopy.
Methods: Human cadaveric dura, mounted on a cylindrical model, was punctured with epidural needles using a micromanipulator. Tissue was punctured at 15 cm H2O (left lateral decubitus) system pressure, and leak was measured at 25 cm H2O (semisitting) pressure. Leak rates and trauma were compared for the following: (1) six different epidural needles at 90[degrees], bevel parallel to the dural long axis; (2) 18-gauge Tuohy and 18-gauge Special Sprotte(R) epidural needles, 30[degrees]versus 90[degrees]; (3) 18-gauge Tuohy, bevel perpendicular versus parallel to the dural long axis.
Results: With the 90[degrees] puncture, bevel parallel, the greatest leak occurred with a 17-gauge Hustead (516 +/- 319 ml/15 min), and the smallest leak occurred with a 20-gauge Tuohy (100 +/- 112 ml/15 min; P = 0.0018). A 20-gauge Tuohy puncture led to statistically significant reductions in leak (P value range, 0.0001-0.0024) compared with all needles except the Special Sprotte(R). With the 30[degrees]versus 90[degrees] angle, 30[degrees] punctures with an 18-gauge Tuohy produced nonstatistically significant leak reductions compared with the 18-gauge Tuohy at 90[degrees]. The puncture angle made no difference for the Special Sprotte(R). Nonsignificant reductions were found for the Special Sprotte(R) compared with the Tuohy. With the 18-gauge Tuohy bevel orientation, perpendicular orientation produced nonstatistically significant reductions in leak compared with parallel orientation. 相似文献
Ipsilateral and contralateral pairs of augmenting expiratory neurons were recorded simultaneously from the Bötzinger complex using glass-coated tungsten microelectrodes in pentobarbitone-anaesthetized cats. The neurons were identified both by firing pattern and by antidromic activation from the contralateral site of the dorsal respiratory group. Cross-correlation histograms of the extracellularly recorded action potentials were calculated in order to detect short time-scale synchronizations of firing indicative of synaptic connections between the neurons. The cross-correlation histograms for 40 ipsilateral pairs of neurons less than 1 mm apart showed eight (20%) narrow troughs (mean half-amplitude width ±SD, 1.1±0.37 ms) at short latencies (mean latency±SD, 1.0±0.35 ms) suggestive of monosynaptic inhibition. These included two cross-correlation histograms which showed troughs on both sides of time zero, indicating a mutual inhibition. For another four pairs of neurons (10%), a central broad peak suggestive of common activation due to either excitation or release from inhibition was evident. Contralateral pairs of expiratory neurons of the Bötzinger complex were examined in a similar manner. The cross-correlation histograms for 43 pairs of neurons showed five (12%) narrow troughs (mean half-amplitude width±SD, 1.2±0.67 ms) at short latencies (mean latency±SD, 2.7±1.47 ms) suggestive of monosynaptic inhibition. These included one cross-correlation histogram which showed troughs (one not statistically significant) on both sides of time zero, indicating a mutual inhibition. For another two pairs of neurons (4.6%) a central, broad peak suggestive of common activation due to either excitation or release from inhibition was evident. We conclude that inhibitory interconnections exist between augmenting expiratory neurons of the Bötzinger complex ipsilaterally and contralaterally. These connections may synchronize the expiratory burst of activity within this population and assist in the patterning of the burst. 相似文献
The efficiency of the respiratory system presents significant limitations on the bodys ability to perform exercise due to the effects of the increased work of breathing, respiratory muscle fatigue, and dyspnoea. Respiratory muscle training is an intervention that may be able to address these limitations, but the impact of respiratory muscle training on exercise performance remains controversial. Therefore, in this study we evaluated the effects of a 12-week (10 sessions week–1) concurrent inspiratory and expiratory muscle training (CRMT) program in 34 adolescent competitive swimmers. The CRMT program consisted of 6 weeks during which the experimental group (E, n=17) performed CRMT and the sham group (S, n=17) performed sham CRMT, followed by 6 weeks when the E and S groups performed CRMT of differing intensities. CRMT training resulted in a significant improvement in forced inspiratory volume in 1 s (FIV1.0) (P=0.050) and forced expiratory volume in 1 s (FEV1.0) (P=0.045) in the E group, which exceeded the S groups results. Significant improvements in pulmonary function, breathing power, and chemoreflex ventilation threshold were observed in both groups, and there was a trend toward an improvement in swimming critical speed after 12 weeks of training (P=0.08). We concluded that although swim training results in attenuation of the ventilatory response to hypercapnia and in improvements in pulmonary function and sustainable breathing power, supplemental respiratory muscle training has no additional effect except on dynamic pulmonary function variables. 相似文献
Echocardiography overestimates left ventricular mass in hemodialysis patients relative to magnetic resonance imaging. BACKGROUND: Left ventricular hypertrophy (LVH) is a common finding and a strong adverse prognostic factor in patients with chronic renal failure. An accurate method of measuring left ventricular mass (LV mass) is therefore a prerequisite in the management of these patients. Recent evidence has suggested that echocardiography overestimates LV mass in patients with essential hypertension, and this error increases with increasing LV mass. METHODS: We studied 35 patients on maintenance hemodialysis within 24 hours of their last dialysis. LV mass was measured by both echocardiography and magnetic resonance imaging (MRI) performed less than three hours apart. Clinic and ambulatory blood pressure (ABPM), resting echocardiogram, and blood sampling were performed at the same visit. RESULTS: Thirty-two patients had results from both methods. Clinic blood pressure, ABPM, and QT dispersion all correlated with LV mass, with a stronger correlation observed for MRI values. Intraobserver and interobserver variability were significantly greater for echocardiography (although similar to other published data). Comparing the two methods, the difference in LV mass values (echo minus magnetic resonance) increased in a linear fashion with an increasing mean mass and chamber diameter. CONCLUSIONS: Echocardiography significantly overestimates LV mass relative to MRI in the presence of LVH and dilation. This overestimation is the result of assumptions made in the calculation of mass from echocardiography M-mode images, which are invalid when LV geometry is abnormal. This error is therefore amplified in dialysis patients, the majority of whom have LVH and in whom intravascular volume is constantly changing. 相似文献
A study of general practice involving 23 health authorities and 2,270 practices completed last year, revealed considerable variations across England and Wales. Single-handed practices account for an average of 29 per cent of all those in the study. The majority of HAs had no practices linked to NHSnet. More than half the practices offered early morning surgeries, and many also offered appointments after six o'clock. 相似文献