Limited data exists demonstrating the efficacy of minimally invasive surgery (MIS) compared to median sternotomy (MS) for multiple valvular disease (MVD). This systematic review and meta-analysis aims to compare operative and peri-operative outcomes of MIS vs MS in MVD.
Methods
PubMed, Ovid, and Embase were searched from inception until August 2019 for randomized and observational studies comparing MIS and MS in patients with MVD. Clinical outcomes of intra- and postoperative times, reoperation for bleeding and surgical site infection were evaluated.
Results
Five observational studies comparing 340 MIS vs 414 MS patients were eligible for qualitative and quantitative review. The quality of evidence assessed using the Newcastle-Ottawa scale was good for all included studies. Meta-analysis demonstrated increased cardiopulmonary bypass time for MIS patients (weighted mean difference [WMD], 0.487; 95% confidence interval [CI], 0.365-0.608; P < .0001). Similarly, aortic cross-clamp time was longer in patients undergoing MIS (WMD, 0.632; 95% CI, 0.509-0.755; P < .0001). No differences were found in operative mortality, reoperation for bleeding, surgical site infection, or hospital stay.
Conclusions
MIS for MVD have similar short-term outcomes compared to MS. This adds value to the use of minimally invasive methods for multivalvular surgery, despite conferring longer operative times. However, the paucity in literature and learning curve associated with MIS warrants further evidence, ideally randomized control trials, to support these findings. 相似文献
Histamine, specific H1-and H2-receptor agonists in conjunction with specific H1-and H2-receptor antagonists and other types of classical antagonists were used to characterize histamine receptors in the vasa deferentia of mice, rats and guinea pigs. The H1-receptor mediates contraction while the H2-receptor produces inhibition. There were marked qualitative and quantitative differences in the distribution of the two types of histamine receptors in the vas deferens of different species. Results indicate that mouse and rat vas deferens contain an inhibitory H2-receptor, but virtually no excitatory H1-receptor. In contrast, guinea pig vas deferens contained an excitatory H1-receptor but was essentially devoid of an inhibitory H2-receptor. The rank order of relative potencies of various agonists as well as the calculated pA2 values of cimetidine in the mouse and rat vas deferens suggest that the two species probably have the same H2-receptor. High concentrations of histamine and 2-methyl histamine have a stimulant action in the mouse and rat vas deferens which was secondary to release of endogenous noradrenaline rather than to the stimulation of an excitatory H1-receptor. 相似文献
The effect of histamine on adrenergic neurotransmission in the mouse isolated vas deferens preparation was investigated. Concentrations of histamine ranging from 0.2 to 650 M depressed, in a dose-related manner, not only the contractile response elicited by field stimulation but also the response caused by the addition of exogenous noradrenaline and acetylcholine. However, the release of [3H]-NA evoked by field stimulation or by high K+ remained unchanged in the presence of these concentrations of histamine. The inhibitory effect of histamine on the contractile responses caused by various stimuli was reduced or completely antagonized by cimetidine, a histamine H2-receptor antagonist but not by mepyramine, a conventional antihistamine. The inhibitory effect of histamine was found to be inversely proportional to both the Ca2+ concentration in the bathing medium and to the frequency of field stimulation. Further, the inhibitory effect of histamine was markedly reduced when Mg2+ was omitted from the bathing medium. It is concluded that the mouse vas deferens preparation contains a post-junctional inhibitory H2-receptor. The stimulation of H2-receptors by histamine inhibits the contractile response of the vas deferens, possibly by decreasing the availability of Ca2+ required for contraction by depressing the influx of Ca2+. 相似文献
Of 613 children evaluated in a village in Haryana 94 (15.3%) were observed to have chronic suppurative otitis media (CSOM).
Fifty eight (61.7%) children had hearing impairment. CSOM contributed to 71.6% of the hearing impaired (58/81). On analysis
of association of CSOM with literacy and socio-economic status of mothers, and age, sex, and upper respiratory tract infections
(URI) in children positive correlation was observed only with URIs (P<0.001).
Literacy and socio-economic status of the mothers did not correlate significantly with knowledge about treatment seeking,
and ear cleaning practices, probably due to the narrow range of incomes and literacy levels. An intervention program consisting
of play, demonstrations, health charts and slogans, and aural cleaning and antibiotic drops was introduced. 相似文献
The aim of the present study was to evaluate the effect of brushing with two whitening dentifrices (Colgate Optic White (COW) and Colgate Optic White Charcoal (COC)) on surface gloss, micro-roughness, and micro-hardness of nanostructured hybrid conventional (Z350) and bulk-fill (Tetric N Ceram bulk-fill) polymer composite. In total, 96 disk samples using two nano-hybrid composite polymers (Z350 and Tetric N Ceram Bulk-fill) were prepared. All specimens were exposed to two different dentifrices (COW and COC), resulting in four main subgroups in the study. Specimens were assessed for surface gloss, micro-roughness (Ra), and micro-hardness using standardized methodology. Means and standard deviations of properties compared using paired t-test, one-way and two-way ANOVA, and post hoc test. The presence of dentifrices did not show any significant difference in micro-hardness values of Z350 (p > 0.05), whereas micro-hardness of bulk-fill composite significantly reduced on dentifrices exposure (p ≤ 0.05). Bulk-fill polymer composite showed significant reduction in gloss after dentifrice exposure (p < 0.05), however, Z350 showed no significant loss of gloss due to dentifrices (p > 0.05). A significant increase in Ra was observed for both resin materials after exposure to dentifrices (COC and COW). Conventional resin composite (Z350) showed comparable surface hardness and gloss before and after dentifrice exposure, however, micro-roughness increased significantly due to dentifrice exposure. Bulk-fill resin (Tetric N Ceram) showed significant loss of micro-hardness and gloss and increase in micro-roughness on dentifrice exposure. Conventional nano-hybrid composite polymer showed better durability in resisting loss of surface properties compared to bulk-fill resin polymer in the present experiment. 相似文献
The high-entropy transition metal borides containing a random distribution of five or more constituent metallic elements offer novel opportunities in designing materials that show crystalline phase stability, high strength, and thermal oxidation resistance under extreme conditions. We present a comprehensive theoretical and experimental investigation of prototypical high-entropy boride (HEB) materials such as (Hf, Mo, Nb, Ta, Ti)B2 and (Hf, Mo, Nb, Ta, Zr)B2 under extreme environments of pressures and temperatures. The theoretical tools include modeling elastic properties by special quasi-random structures that predict a bulk modulus of 288 GPa and a shear modulus of 215 GPa at ambient conditions. HEB samples were synthesized under high pressures and high temperatures and studied to 9.5 GPa and 2273 K in a large-volume pressure cell. The thermal equation of state measurement yielded a bulk modulus of 276 GPa, in excellent agreement with theory. The measured compressive yield strength by radial X-ray diffraction technique in a diamond anvil cell was 28 GPa at a pressure of 65 GPa, which is a significant fraction of the shear modulus at high pressures. The high compressive strength and phase stability of this material under high pressures and high temperatures make it an ideal candidate for application as a structural material in nuclear and aerospace fields. 相似文献
Objective: To evaluate the relationship between first and second trimester maternal serum-free β-hCG and the risk of spontaneous preterm delivery (PTD).
Study design: This was a case-control study of women evaluated and delivered at our institution from 2011 to 2015. Spontaneous PTD was defined as delivery before 37 weeks due to spontaneous preterm labor or premature rupture of membranes. Patient with multifetal gestation and those with medically indicated term or PTD were excluded.
Results: Of 877 women meeting the inclusion criteria, 173 delivered preterm and 704 delivered at term, and 8.1% had high free β-hCG in one or both trimesters. High maternal first and/or second trimester free β-hCG (≥95th percentile) was associated with lower rates of PTD. Thirty-two women with high free β-hCG in both first and second trimesters delivered at term. Gestational age at delivery and birth weights were lower in women who did not have high free β-hCG in any trimester. Low free β-hCG (≤5th percentile) in either trimester was not associated with an increased or decreased likelihood of PTD. Logistic regression demonstrated an independent association of high free β-hCG (≥95th percentile) with a reduced likelihood of PTD. Stratified analysis revealed a stronger impact of this association in women with no prior history of PTD.
Conclusions: High free β-hCG, in the absence of risk factors for medically indicated PTD, is associated with a reduced likelihood of spontaneous PTD and may represent a marker indicating lower risk. 相似文献
Congenital factor VII deficiency is an autosomal recessive serious disorder of blood coagulation with wide genotypic and phenotypic variations. The clinical presentation can vary from asymptomatic patients to patients with major bleedings in severe deficiency (factor VII <1%). Investigations show prolonged PT and low factor VII. Treatment modalities include FFP and repeated recombinant factor VII infusions. We hereby report the first successful LRLT for factor VII deficiency in an infant, the first‐ever youngest baby reported worldwide. A six‐month‐old male child presented with easy bruisability, ecchymotic patches, hematuria, and convulsions. CT of the head showed subdural hemorrhage, which was treated conservatively. He had markedly increased PT (120 s) with normal platelets, and aPTT with factor VII level <1%. Despite the treatment by rFVIIa administration weekly, which was very expensive, he still had repeated life‐threatening bleeding episodes. LRLT was performed with mother as the donor, whose factor VII level was 57%. A factor VII infusion plan for pre‐, intra‐ and postoperative periods was formulated and TEG followed. Postoperatively, his factor VII started increasing from third day and was 38% on 24th day with PT <14 s. He had uneventful intraoperative and postoperative courses. LT is a safe and definite cure for factor VII deficiency. 相似文献