排序方式: 共有21条查询结果,搜索用时 15 毫秒
1.
2.
JOHN D. FISHER SOO G. KIM JEFFREY A. MATOS ELIOT OSTROW 《Pacing and clinical electrophysiology : PACE》1983,6(4):915-922
Ventricular tachycardias can be terminated by a variety of pacemaker techniques, including rapid and slow stimulation. Fast tachycardias are typically poorly tolerated, and require prompt intervention, usually with rapid pacing. Termination of ventricular tachycardia by slow or single capture pacemaker stimulation techniques is attractive, because of its presumed safety and the possibility of using simple implantable pacers. To identify factors favoring termination, single capture stimulation was used in 390 episodes of ventricular tachycardia in 21 patients, 16 with coronary artery disease, able to tolerate ventricular tachycardia forseveral minutes. Single capture stimulation terminated 223 episodes (57%) in 18 patients, and two were accelerated. Of 157 episodes exposed to 2–3 programmed extrastimuli or rapid pacing 149 (94%) were terminated and 7 were accelerated. Direct current cardioversion was needed in 12 episodes. Without medications, only two patients tolerated VT. Only one patient had reliable termination with single capture stimulation over several days. Systolic blood pressure was similar in episodes terminated and not terminated by single capture stimulation, but the ventricular rate was significantly lower in episodes terminated, 116 ± 19 vs. 133 ±24 (p<0.001). Termination of ventricular tachycardia was not affected by QRS morphology. Single capture termination of ventricular tachycardia is largely unpredictable, with limited reproducibility over a period of time. Although comparatively safe, single capture techniques are not likely toprove useful in the long-term treatment of many patients with recurrent ventricular tachycardia. 相似文献
3.
4.
5.
6.
7.
8.
HAW‐KWEI HWANG M.D. PAOLO RUSCONI M.D. ELIOT ROSENKRANZ M.D. MING‐LON YOUNG M.D. M.P.H. 《Pacing and clinical electrophysiology : PACE》2010,33(8):e68-e71
An 11‐year‐old boy, who underwent bicaval orthotopic heart transplantation for idiopathic dilated cardiomyopathy, had a focal atrial tachycardia originating from the donor superior vena cava. The pathogenesis of this tachycardia may be related to transplant rejection or transplant vasculopathy. Radiofrequency catheter ablation can eliminate this unique tachycardia and result in hemodynamic improvement. (PACE 2010; e68–e71) 相似文献
9.
JOHN D. FISHER MARK GOLDSTEIN ELIOT OSTROW JEFFREY A. MATOS SOO G. KIM 《Pacing and clinical electrophysiology : PACE》1983,6(2):221-228
In addition to providing basic physiologic information, knowledge of the maximal rate of sinus tachycardia development may be helpful in developing algorithms permitting new generations of antitachycardia pacemakers to distinguish accurately between sinus and ventricular tachycardia. To determine the maximal rate of sinus tachycardia development, 50 normal subjects rushed up 100 stairs as rapidly as possible, with continuous electrocardiographic monitoring. During the first second of exercise, the mean cardiac cycle length shortened from 709 to 570 ms, equivalent to an increase in heart rate from 85 to 105 beats per minute, or 20 beats per minute per second. Thereafter, a more gradual decrease in cycle length occurred. Differences between men and women, smokers and non-smokers, and sedentary compared to active subjects were all insignificant. Analysis of 50 spontaneous episodes of ventricular tachycardia also revealed a sequential but more abrupt decrease in the cycle length during the first second from 757 to 360 ms, equivalent to a rate increase from 79 to 167 beats per minute, or 88 beats per minute per second. After approximately 1 1 /4 seconds, the ventricular tachycardia cycle length remained virtually constant. Baseline cycle lengths were similar in the sinus and ventricular tachycardia groups, but differed in all subsequent beats, although overlap for individual subjects did occur. 相似文献
10.