首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
PURPOSE: To compare dose distribution and normal tissue sparing in partial-breast treatment using three-dimensional conformal radiotherapy (3D-CRT) vs. intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS: Sixty-three patients with Tis-1N0M0 breast cancer were treated on a Phase II prospective accelerated partial-breast IMRT protocol at two facilities between April 2004 and January 2006. Fifty-six patients had data sets sufficient to adequately contour all structures. These cases were subsequently replanned with 3D-CRT techniques using the same contours, to compare the dose distribution patterns of 3D-CRT vs. IMRT. RESULTS: The average planning target volume (PTV) to ipsilateral breast (IB) ratio was 24% (range, 7-58%). The average volume of IB receiving 25%, 50%, 75%, and 100% of the prescribed dose was 4.0%, 5.0%, 5.5%, and 10.5% less with IMRT than with 3D (p < 0.01). The dose reduction to normal breast was further improved in the subset of patients whose PTV to IB ratio was >25%, and in patients with contoured breast volume <750 cm(3). No difference was detected in delivery to the lumpectomy cavity or clinical target volume. The PTV volume receiving 95% of the dose was higher in the 3D conformal plans (p < 0.01), but no significant difference was observed in the PTV volume receiving 90% (p = 0.17). The irradiated heart and lung volumes were small with both techniques but also favored IMRT. CONCLUSIONS: In T1N0 patients treated with external beam partial-breast radiotherapy, IMRT improves normal tissue sparing in the ipsilateral breast compared with 3DRT, without compromising dose delivery to the lumpectomy cavity and clinical target volume.  相似文献   

3.
Introduction: The purpose of the study was to determine if multi‐field inverse‐planned intensity‐modulated radiation therapy (IMRT) improves on the sparing of organs at risk (heart, lungs and contralateral breast) when compared with field‐in‐field forward‐planned RT (FiF). Methods: The planning CT scans of 10 women with left‐sided breast cancer previously treated with whole‐breast RT on an inclined breast board with both arms supported above the head were retrieved. The whole breast planning target volume (PTV) was defined by clinical mark‐up and contoured on all relevant CT slices as were the organs at risk. For each patient, three plans were generated using FiF, five‐ and nine‐field inverse‐planned IMRT, all to a total dose of 50 Gy to the whole breast. Mean and maximum doses to the organs at risk and the homogeneity index (HI) of the whole‐breast PTV were compared. Results: The mean heart dose for the FiF plans was 2.63 Gy compared with 4.04 Gy for the five‐field and 4.30 Gy for the nine‐field IMRT plans, with no significant differences in the HI of the whole‐breast PTV in all plans. The FiF plans resulted in a mean contralateral breast dose of 0.58 Gy compared with 0.70 and 2.08 Gy for the five‐ and nine‐field IMRT plans, respectively. Conclusions: FiF resulted in a lower mean heart and contralateral breast dose with comparable HI of the whole‐breast PTV in comparison with inverse‐planned IMRT using five or nine fields.  相似文献   

4.
PURPOSE: To investigate the potential for intensity-modulated radiotherapy (IMRT) to spare the bowel in rectal tumors. METHODS AND MATERIALS: The targets (pelvic nodal and rectal volumes), bowel, and bladder were outlined in 5 patients. All had conventional, three-dimensional conformal RT and forward-planned multisegment three-field IMRT plans compared with inverse-planned simultaneous integrated boost nine-field equally spaced IMRT plans. Equally spaced seven-field and five-field and five-field, customized, segmented IMRT plans were also evaluated. RESULTS: Ninety-five percent of the prescribed dose covered at least 95% of both planning target volumes using all but the conventional plan (mean primary and pelvic planning target volume receiving 95% of the prescribed dose was 32.8 +/- 13.7 Gy and 23.7 +/- 4.87 Gy, respectively), reflecting a significant lack of coverage. The three-field forward planned IMRT plans reduced the volume of bowel irradiated to 45 Gy and 50 Gy by 26% +/- 16% and 42% +/- 27% compared with three-dimensional conformal RT. Additional reductions to 69 +/- 51 cm(3) to 45 Gy and 20 +/- 21 cm(3) to 50 Gy were obtained with the nine-field equally spaced IMRT plans-64% +/- 11% and 64% +/- 20% reductions compared with three-dimensional conformal RT. Reducing the number of beams and customizing the angles for the five-field equally spaced IMRT plan did not significantly reduce bowel sparing. CONCLUSION: The bowel volume irradiated to 45 Gy and 50 Gy was significantly reduced with IMRT, which could potentially lead to less bowel toxicity. Reducing the number of beams did not reduce bowel sparing and the five-field customized segmented IMRT plan is a reasonable technique to be tested in clinical trials.  相似文献   

5.
PURPOSE: To perform a dosimetric comparison of three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and helical tomotherapy (HT) plans for pelvic and para-aortic RT in postoperative endometrial cancer patients; and to evaluate the integral dose (ID) received by critical structures within the radiation fields. METHODS AND MATERIALS: We selected 10 patients with Stage IIIC endometrial cancer. For each patient, three plans were created with 3D-CRT, IMRT, and HT. The IMRT and HT plans were both optimized to keep the mean dose to the planning target volume (PTV) the same as that with 3D-CRT. The dosimetry and ID for the critical structures were compared. A paired two-tailed Student t test was used for data analysis. RESULTS: Compared with the 3D-CRT plans, the IMRT plans resulted in lower IDs in the organs at risk (OARs), ranging from -3.49% to -17.59%. The HT plans showed a similar result except that the ID for the bowel increased 0.27%. The IMRT and HT plans both increased the IDs to normal tissue (see Table 1 and text for definition), pelvic bone, and spine (range, 3.31-19.7%). The IMRT and HT dosimetry showed superior PTV coverage and better OAR sparing than the 3D-CRT dosimetry. Compared directly with IMRT, HT showed similar PTV coverage, lower Ids, and a decreased dose to most OARs. CONCLUSION: Intensity-modulated RT and HT appear to achieve excellent PTV coverage and better sparing of OARs, but at the expense of increased IDs to normal tissue and skeleton. HT allows for additional improvement in dosimetry and sparing of most OARs.  相似文献   

6.
BACKGROUND AND PURPOSE: To investigate the potential of intensity-modulated radiotherapy (IMRT) to reduce lung irradiation in the treatment of oesophageal carcinoma with radical radiotherapy. MATERIALS AND METHODS: A treatment planning study was performed to compare two-phase conformal radiotherapy (CFRT) with IMRT in five patients. The CFRT plans consisted of anterior, posterior and bilateral posterior oblique fields, while the IMRT plans consisted of either nine equispaced fields (9F), or four fields (4F) with orientations equal to the CFRT plans. IMRT plans with seven, five or three equispaced fields were also investigated in one patient. Treatment plans were compared using dose-volume histograms and normal tissue complication probabilities. RESULTS: The 9F IMRT plan was unable to improve on the homogeneity of dose to the planning target volume (PTV), compared with the CFRT plan (dose range, 16.9+/-4.5 (1 SD) vs. 12.4+/-3.9%; P=0.06). Similarly, the 9F IMRT plan was unable to reduce the mean lung dose (11.7+/-3.2 vs. 11.0+/-2.9 Gy; P=0.2). Similar results were obtained for seven, five and three equispaced fields in the single patient studied. The 4F IMRT plan provided comparable PTV dose homogeneity with the CFRT plan (11.8+/-3.3 vs. 12.4+/-3.9%; P=0.6), with reduced mean lung dose (9.5+/-2.3 vs 11.0+/-2.9 Gy; P=0.001). CONCLUSIONS: IMRT using nine equispaced fields provided no improvement over CFRT. This was because the larger number of fields in the IMRT plan distributed a low dose over the entire lung. In contrast, IMRT using four fields equal to the CFRT fields offered an improvement in lung sparing. Thus, IMRT with a few carefully chosen field directions may lead to a modest reduction in pneumonitis, or allow tumour dose escalation within the currently accepted lung toxicity.  相似文献   

7.
8.
9.
BACKGROUND AND PURPOSE: For some treatment sites, there is evidence in the literature that five to nine equi-angular input beam directions are enough for generating IMRT plans. For oesophagus cancer, there is a report showing that going from four to nine beams may even result in lower quality plans. In this paper, our previously published algorithm for automated beam angle selection (Cycle) has been extended to include segmented IMRT. For oesophagus cancer patients, we have investigated whether automated orientation selection from a large number of equi-angular input beam directions (up to thirty-six) for IMRT optimisation can result in improved lung sparing. MATERIALS AND METHODS: CT-data from five oesophagus patients treated recently in our institute were used for this study. For a prescribed mean PTV dose of 55 Gy, Cycle was used in an iterative procedure to minimise the mean lung dose under the following hard constraints: standard deviation for PTV dose inhomogeneity 2% (1,1 Gy), maximum spinal cord dose 45 Gy. Conformal radiotherapy (CFRT) and IMRT plans for a standard four field oesophagus beam configuration were compared with IMRT plans generated by automated selection from nine or thirty-six equi-angular input beam orientations. Comparisons were also made with dose distributions generated with our commercial treatment planning system (TPS), and with observations in the literature. RESULTS: Using Cycle, automated orientation selection from nine or thirty-six input beam directions resulted in improved lung sparing compared to the four field set-ups. Compared to selection from nine input orientations, selection from thirty-six directions did always result in lower mean lung doses, sometimes with even fewer non-zero weight beams. On average only seven beams with a non-zero weight were enough for obtaining the lowest mean lung dose, yielding clinically feasible plans even in case of thirty-six input directions for the optimisation process. With our commercial TPS we observed the same contra-intuitive, unfavourable results as reported in the literature; nine field equi-angular IMRT plans had substantially higher mean lung doses than plans for the conventional four field set-ups. For all cases, the Cycle plans generated from nine equi-angular input directions were superior compared to similar plans generated with our commercial TPS. CONCLUSIONS: For the studied oesophagus cancer patients the best plans for IMRT were obtained with Cycle, using automated beam orientation selection from thirty-six input beam directions. The lowest mean lung doses could be obtained with, on average, a selection of only seven beams with non-zero weight.  相似文献   

10.
乳腺癌调强放射治疗和常规切线野治疗的三维剂量学研究   总被引:17,自引:1,他引:16  
Huang XB  Jiang GL  Chen JY  Chen LF  Hu WG 《癌症》2006,25(7):855-860
背景与目的:乳房保留治疗已在早期乳腺癌患者中逐渐推广应用,其中全乳根治性放疗的标准技术通常采用常规切线野技术。调强放射治疗(intensity-modulatedradiotherapy,IMRT)技术有望在保障相同疗效的同时进一步减少放疗并发症,提高生活质量。本研究利用三维计划系统评价全乳IMRT的剂量学优势与适应证。方法:选择10例接受保乳手术的Tis~2N0M0早期乳腺癌病例,利用三维治疗计划系统为每例患者设计两种全乳放射治疗计划,切线野常规计划与IMRT计划,处方剂量均为5000cGy。用剂量体积直方图(dosevolumehistograms,DVH)来比较各种计划中计划靶体积(planningtargetvolume,PTV)、危及器官(organsatrisks,OARs)的剂量学差异。结果:靶区覆盖率在两种计划中相似,分别为98.3%和97.7%。与常规计划比较,IMRT计划的PTV接受<95%处方剂量与>103%处方剂量的体积百分比之和(inhomogeneityindex,IHI)从29.9%减少到2.9%,PTV接受至少105%处方剂量照射的体积百分比(V105%)从28.2%减少到0.6%;IMRT计划改善IHI和减少V105%的平均值在PTV较大的患者中优势更明显。左侧患者中冠状动脉的最大剂量(Dmax)以及心脏的平均剂量(Dmean)分别从5057.1cGy减少到4832.9cGy和从629.8cGy到450.7cGy;右侧患者肝脏的Dmean从283.9cGy减少到172.0cGy;所有患者中同侧肺的Dmean、至少接受20Gy照射的体积百分比(V20)分别从925.2cGy减少到765.9cGy,从16.0%到15.3%,Dmean与V20的平均值在IMRT计划中减少的百分比在不同射野中心肺厚度(centrallungdistance,CLD)亚组中分别是14.7%与20.9%,7.0%与12.9%;对侧乳腺和对侧肺的Dmean也分别从75.4cGy减少到20.3cGy和从30.9cGy到16.1cGy。结论:全乳IMRT的剂量学优势主要在于保证靶区覆盖率的前提下,显著改善靶区的剂量分布均匀性并一定程度上降低OARs的受照剂量与容积。乳房体积和CLD较大的病例可以通过IMRT技术获得更好的剂量学结果。  相似文献   

11.
PURPOSE: To develop an intensity modulated radiotherapy (IMRT) technique for postmastectomy RT that improves target coverage while sparing all appropriate normal tissues. MATERIALS AND METHODS: IMRT plans were generated using an in-house optimization system. Priority was given to matching the heart doses achieved with partially wide tangent fields (PWTFs) while maintaining 50 Gy +/- 5% to the chest wall, internal mammary nodes, and supraclavicular nodes. Other normal tissue doses were then minimized. Metrics for plan comparisons included minimal, maximal, and mean doses and normal tissue complication probability. RESULTS: IMRT resulted in more uniform chest wall coverage than did PWTFs. The average chest wall minimal dose was 43.7 +/- 1.1 Gy for IMRT and 31.2 +/- 16.5 Gy for PWTFs (p = 0.04). The average internal mammary node minimal dose was 42.8 +/- 2.1 Gy for IMRT and 21.8 +/- 13.2 Gy for PWTFs (p = 0.001). IMRT matched the <1% heart normal tissue complication probability achieved using PWTFs. The average contralateral breast mean dose was 2.8 +/- 1.7 Gy for IMRT, but a greater breast volume was exposed compared with PWTFs. The mean ipsilateral lung normal tissue complication probability was lower for IMRT (0.0) than for PWTFs (0.07 +/- 0.07; p = 0.02). The mean contralateral lung dose was greater for IMRT (5.8 +/- 1.8 Gy) than for PWTFs (1.6 +/- 0.1 Gy; p = <0.0001). CONCLUSION: A new IMRT technique achieves full target coverage while maintaining similar doses to heart and ipsilateral lung as conventional techniques. However, contralateral lung and breast volumes exposed to low doses were increased with IMRT and will need to be reduced in future studies.  相似文献   

12.
13.
14.
Background: To compare the dosimetric coverage of target volumes and organs at risk in the radicaltreatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and threedimensionalconformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patientstreated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively foranalysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans usinga total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The meansof each comparison target volume coverage measures and organs at risk measures were obtained and testedfor statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverageshowed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absoluteimprovement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organsat risk showed statistically significant difference in their means which were clinically meaningful between theIMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid(less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coveragewhile delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as astandard of care for radical treatment of NPC.  相似文献   

15.
PURPOSE: Intensity-modulated radiotherapy (IMRT) offers the potential to more closely conform dose distributions to the target, and spare organs at risk (OAR). Its clinical value is still being defined. The present study aims to compare IMRT with stereotactically guided conformal radiotherapy (SCRT) for patients with medium size convex-shaped brain tumors. METHODS AND MATERIALS: Five patients planned with SCRT were replanned with the IMRT-tomotherapy method using the Peacock system (Nomos Corporation). The planning target volume (PTV) and relevant OAR were assessed, and compared relative to SCRT plans using dose statistics, dose-volume histograms (DVH), and the Radiation Therapy Oncology Group (RTOG) stereotactic radiosurgery criteria. RESULTS: The median and mean PTV were 78 cm3 and 85 cm3 respectively (range 62-119 cm3). The differences in PTV doses for the whole group (Peacock-SCRT +/-1 SD) were 2%+/-1.8 (minimum PTV), and 0.1%+/-1.9 (maximum PTV). The PTV homogeneity achieved by Peacock was 12.1%+/-1.7 compared to 13.9%+/-1.3 with SCRT. Using RTOG guidelines, Peacock plans provided acceptable PTV coverage for all 5/5 plans compared to minor coverage deviations in 4/5 SCRT plans; acceptable homogeneity index for both plans (Peacock = 1.1 vs. SCRT = 1.2); and comparable conformity index (1.4 each). As a consequence of the transaxial method of arc delivery, the optic nerves received mean and maximum doses that were 11.1 to 11.6%, and 10.3 to 15.2% higher respectively with Peacock plan. The maximum optic lens, and brainstem dose were 3.1 to 4.8% higher, and 0.6% lower respectively with Peacock plan. However, all doses remained below the tolerance threshold (5 Gy for lens, and 50 Gy for optic nerves) and were clinically acceptable. CONCLUSIONS: The Peacock method provided improved PTV coverage, albeit small, in this group of convex tumors. Although the OAR doses were higher using the Peacock plans, all doses remained within the clinically defined threshold and were clinically acceptable. Further improvements may be expected using other methods of IMRT planning that do not limit the treatment delivery to transaxial arcs. Each IMRT system needs to be individually assessed as the paradigm utilized may provide different outcomes.  相似文献   

16.
PURPOSE: Three types of preoperative radiotherapy (RT) plans for extremity soft tissue sarcoma were compared to determine the amount of dose reduction possible to the planned surgical skin flaps required for tumor resection and wound closure, without compromising target coverage. METHODS AND MATERIALS: Twenty-four untreated patients with large, deep, lower extremity STS treated with preoperative RT and limb salvage surgery had their original conventional treatment plans re-created. The same clinical target volume was used for all three plans. The future surgical skin flaps were created virtually through contouring by the treating surgeon and regarded as an organ at risk. The original, conformal, and intensity-modulated RT (IMRT) plans were created to deliver 50 Gy in 25 fractions to the clinical target volume. Clinical target volume and organ-at-risk dose-volume histograms were calculated and the plans compared for conformality, target coverage, and dose sparing. RESULTS: The mean dose to the planned skin flaps was 42.62 Gy (range, 30.24-48.65 Gy) for the original plans compared with 40.12 Gy (range, 24.24-47.26 Gy) for the conformal plans and 26.71 Gy (range, 22.31-31.91 Gy) for the IMRT plans (p = 0.0008). An average of 86.4% (range, 53.2-97.4%) of the planned skin flaps received >or=30 Gy in the original plans compared with 83.4% (range, 36.2-96.2%) in the conformal plans and only 34.0% (range, 22.5-53.3%) in the IMRT plans (p = 0.0001). IMRT improved target conformality compared with the original and conformal plans (1.27, 2.34, and 1.76, respectively, p = 0.0001). CONCLUSION: In a retrospective review, preoperative IMRT substantially lowered the dose to the future surgical skin flaps, sparing a greater percentage of this structure's volume without compromising target (tumor) coverage.  相似文献   

17.
BACKGROUND AND PURPOSE: To evaluate the feasibility of sparing the parotid glands and surgically transferred submandibular gland (SMG) by intensity modulated radiotherapy (IMRT) in post-operative cases of head and neck cancer (HNC). MATERIALS AND METHODS: Ten patients (larynx-2, base of tongue-4, tonsil-3, and unknown primary-1; pathologic stages III-IV) who underwent SMG transfers on the side of N0 neck along with definitive surgery were selected for this study. IMRT planning was done retrospectively using helical tomotherapy approach. Planning objective was to deliver 60 Gy to PTV1 and 54 Gy to PTV2 while maintaining the mean dose to the total parotid volume (TPV) and SMG less than 26 Gy. RESULTS: The mean dose (+/-SD) to the TPV and SMG were 25+/-0.6 Gy and 23+/-1.9 Gy, respectively. The D(95) for PTV1 and PTV2 were 59.9+/-0.1 Gy and 54.9+/-0.3 Gy, respectively, satisfying our planning goal for PTV coverage. The D(99) for PTV1 and PTV2 were 58.2+/-0.7 Gy and 49.5+/-2.2 Gy, respectively, showing that sparing the salivary glands did not result in underdosing of the PTVs. CONCLUSIONS: By combining the gland transfer and IMRT, the mean dose to TPV and transferred SMG could be reduced to less than 26 Gy in post-operative patients of HNC.  相似文献   

18.
目的:探讨危及器官的不同定义对左侧乳腺癌逆向调强放疗计划的影响。方法:各20例改良根治术和保乳术的左侧乳腺癌患者纳入本研究,放疗前均行增强定位CT薄层扫描。当靶区包括内乳区时,比较将全心(A组)和全心+冠状动脉左前降支(LAD)(B组)作为危及器官时计划靶区(PTV)和各危及器官(OAR)的剂量-体积的变化。结果:2组计划的PTV、双侧肺的剂量-体积无明显差异,但B组的心脏和LAD的部分剂量-体积参数明显低于A组,而患侧肺的部分剂量-体积参数却高于A组,差异均具有统计学意义(P<0.05)。结论:为更好地保护心脏、LAD,左侧乳腺癌放疗内乳区时应增加LAD作为独立的危及器官。  相似文献   

19.
PURPOSE: Lungs are the major dose-limiting organ during radiotherapy (RT) for non-small-cell lung cancer owing to the development of pneumonitis. This study compared intensity-modulated RT (IMRT) with three-dimensional conformal RT (3D-CRT) in reducing the dose to the lungs. METHODS: Ten patients with localized non-small-cell lung cancer underwent computed tomography (CT). The planning target volume (PTV) was defined and the organs at risk were outlined. An inverse-planning program, AutoPlan, was used to design the beam angle-optimized six-field noncoplanar 3D-CRT plans. Each 3D-CRT plan was compared with a series of five IMRT plans per patient. The IMRT plans were created using a commercial algorithm and consisted of a series of three, five, seven, and nine equidistant coplanar field arrangements and one six-field noncoplanar plan. The planning objectives were to minimize the lung dose while maintaining the dose to the PTV. The percentage of lung volume receiving >20 Gy (V20) and the percentage of the PTV covered by the 90% isodose (PTV90) were the primary endpoints. The PTV90/V20 ratio was used as the parameter accounting for both the reduction in lung volume treated and the PTV coverage. RESULTS: All IMRT plans, except for the three-field coplanar plans, improved the PTV90/V20 ratio significantly compared with the optimized 3D-CRT plan. Nine coplanar IMRT beams were significantly better than five or seven coplanar IMRT beams, with an improved PTV90/V20 ratio. CONCLUSION: The results of our study have shown that IMRT can reduce the dose to the lungs compared with 3D-CRT by improving the conformity of the plan.  相似文献   

20.
目的:探讨乳腺癌保乳术后全乳野中野适形调强照射技术方法,并与常规全乳切线野照射技术进行剂量学对比。方法:选取22例早期乳腺癌保乳术后患者在CT模拟机下对乳腺部位行薄层定位扫描,将定位图像传输至治疗计划系统进行全乳野中野计划设计:在全乳两切线适形野的基础上挡去高剂量区部分,另设计2—4个小跳数射野以降低靶区最高剂量和调整高剂量区的范围及所在位置。处方剂量50Gy/25次,要求95%的靶区接受处方剂量;然后利用其CT模拟定位资料按照常规切线野射野方法在治疗计划上模拟常规切线野治疗计划,对野中野计划和常规射野计划进行靶区适形性、靶区均匀性和危及器官受量的比较。结果:野中野适形调强放射治疗技术的适形度、均匀性优于常规切线野照射,靶区内超过110%处方剂量的体积明显小于常规切线野技术。减少了肺组织V20的体积,降低了心脏的平均剂量和受照体积。结论:乳腺癌保乳术后全乳野中野适形调强放射治疗技术是一种有益的全乳照射技术。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号