首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Introduction We report a simplified method of performing antibiotic lock therapy (ALT) based on a disposable central venous catheter (CVC) hub device, CLC 2000, enabling an open-ended CVC to be flushed with normal saline solution without heparin. Methods ALT was administered through a CLC 2000 connector for recurrent CVC-bloodstream infections (BSI) by the same organism in four patients and for CVC colonization in five patients. Results The antibiotic concentration obtained in the lumen of the CVC with ALT was 2,500-fold higher than the minimum inhibiting concentration of targeted bacteria for patients treated with vancomycin, 2,500–80,000-fold higher for patients treated with teicoplanin, and 10,000-fold higher for the patient treated with amikacin. All CVC-BSIs treated with ALT resulted in complete clinical and microbiological responses. No case of malfunction in withdrawing or flushing the CVC and no precipitation during the administration of the antibiotic solution was observed. No recurrence of CVC-BSI or CVC colonization by the same organism was diagnosed during subsequent follow-up, despite the fact that all patients had further periods of severe neutropenia. At the last follow-up, three CVCs had been removed for other infections (fever of unknown origin in two; fungemia in one), four CVCs had been removed at the end of therapy, and one CVC is still in situ 20 months after ALT. Conclusions In conclusion, a course of ALT is feasible in cancer patients with infected but much-needed CVCs before resorting to removal. The use of the CLC 2000 connector device simplifies the procedure for preparation and administration of ALT without compromising its efficacy.  相似文献   

2.
Central venous catheters (CVCs) can be associated with various complications which arise during insertion, with the catheter in situ or upon its removal. Here we report a case of secondary CVC malposition that occurred despite checks of CVC position by different methods. A subclavian triple-lumen catheter was retracted until intra-atrial ECG indicated reversal to a normal P-wave. Blood was successfully aspirated through all three lumens, and the catheter was fixed at 11 centimeters intracorporal length and used intraoperatively. A postoperative chest X-ray demonstrated an intravenous CVC length of only a few centimeters, which was accepted because of the inconspicuous results of previous monitoring. Fifteen hours after CVC insertion, the patient developed a swelling in the subclavian and right neck region, a pronounced hydromediastinum and small bilateral pleural effusions caused by paravenous infusion through the most proximal CVC lumen. After instantaneous removal of the catheter, the patient recovered without further complications. This case demonstrates that even carefully-fixed multi-lumen catheters can partially dislocate due to a patient's movements or changes of position. Therefore, repeated aspiration of blood from the most proximal lumen should be performed to detect secondary CVC malposition. Moreover, repeated chest radiographs are useful in verifying a correct CVC position and detecting late complications. In summary, CVC complications can occur with delay, are potentially life-threatening and may necessitate repeated checks of catheter position. This case report discusses different approaches to detecting malposition and reviews rare CVC complications.  相似文献   

3.
OBJECTIVE: To evaluate the widespread practice of using qualitative culture of venous blood taken through central venous catheters (CVCs) as a means of diagnosing catheter colonisation in situ. DESIGN: A prospective clinical study. PATIENTS: Three hundred fifty-one CVCs were inserted into 228 critically ill patients. INTERVENTIONS: Prior to CVC removal, blood was taken for qualitative culture from the CVC and a peripheral site. All catheter tips underwent semi-quantitative analysis of bacterial colony count [1]. MEASUREMENTS AND RESULTS: One hundred eighteen (33.6%) CVCs were found to be colonised on removal. A positive central blood culture had a sensitivity and specificity of 50.8% and 78.9% when compared with the 'gold standard' of catheter tip culture. This gives a positive predictive value of 47.7% and a negative predictive value of 76.5%. The sensitivity and specificity of a positive peripheral blood culture were 41.5% and 77.7% with positive and negative predictive values of 48.8% and 72.9%, respectively. When only those catheters removed because of systemic sepsis (n = 139) were considered, a positive central blood culture had a sensitivity of 58.8% and a specificity of 69.3%. CONCLUSION: Our results indicate that the use of central blood culture confers a small advantage in sensitivity compared with peripheral blood culture. This advantage was further improved by only considering the catheters removed because of systemic sepsis but at the cost of a loss of specificity. Qualitative blood culture is a poor tool for the diagnosis of in-situ CVC colonisation.  相似文献   

4.
何琼  汤学宇 《新医学》2021,52(4):301-304
中心静脉置管技术在临床上应用广泛,其置管相关并发症也不容忽视。该例维持性血液透析患者在彩色多普勒超声引导下行左侧颈内静脉留置长期透析导管术时出现抵抗感,置管完成后回抽导管动静脉端回血不畅,术后行胸部CT及数字减影血管造影检查发现导管末端进入中纵隔内,未伤及纵隔内血管,予以20 d后导管末端血肿机化后拔除留置导管。该例提示左颈内静脉置管误穿中纵隔可致一些严重甚至致命的并发症,熟悉相关解剖结构、提高置管技术、及时行相关医技检查及治疗是防治并发症的关键。  相似文献   

5.
OBJECTIVE: To determine the relative rates of microbial colonization of individual lumens in triple-lumen central venous catheters (CVCs) and calculate the chance of detecting catheter-related blood stream infection (CRBSI) if only one lumen is sampled. DESIGN: Prospective evaluation of CVCs from suspected and nonsuspected CRBSI cases. SETTING: University teaching hospital. PATIENTS: Triple-lumen CVCs from 50 cases of suspected CRBSI (a raised peripheral white blood cell count, temperature >37 degrees C, and/or local signs of infection at the catheter skin entry site) were evaluated. For comparison, 50 triple-lumen CVCs routinely removed at the end of use were evaluated. MEASUREMENTS: In both groups, peripheral blood cultures were taken before CVC removal. After CVC removal, each lumen was sampled in vitro using the endoluminal brush, and the tip was then cultured using the Maki roll technique. MAIN RESULTS: CVCs causing CRBSI had significant microbial colonization in one, two, or three lumens in ten (40%), ten (40%), or five (20%) cases, respectively. Overall, random sampling of only one lumen in CVCs causing CRBSI had a 60% chance of detecting significant colonization. CONCLUSIONS: If only one CVC lumen is sampled, a negative result does not reliably rule out infection. Each lumen of multiple-lumen CVCs should be considered as a potential source of CRBSI.  相似文献   

6.
Background Totally implantable or partially cuffed central venous catheters (CVC) are commonly used in cancer patients, but they are often expensive and may produce complications. To minimize costs, we have been using a low-cost, partially tunneled, silicone elastomer catheter with no Dacron cuff or antireflux valve (Vygon) since 2001. This study is a retrospective investigation of our experience using the Vygon catheter as a long-term CVC in patients with malignancy.Materials and methods A total of 458 Vygon catheters (Nutricath, Vygon) were percutaneously inserted by an interventional radiologist in 302 cancer patients. The median duration of catheter use was 93 days, mean 164.3 days (range 1–789). Main patient characteristics were as follows: number of male/female patients, 166/136; median age, 51 years; hematological/nonhematological patients, 189/113.Results Early complications were pneumothorax in six and hematoma in twelve of 458 implants, respectively. Thirteen out of 302 patients developed a catheter-related thrombosis. One hundred and thirty-five of 458 Vygon catheters required removal because of catheter-related complications: 68 accidental losses, 37 cases of febrile neutropenia suspected to be catheter-related, ten catheter dislodgements, ten catheter malfunctions, four local infections, three thromboses, two catheter ruptures, and one allergic reaction.Conclusion Vygon catheters do not seem to induce more early and late complications as compared with other more expensive devices, except for disadvantage of the high incidence rate of accidental losses.  相似文献   

7.
Central venous catheter infections: Concepts and controversies   总被引:4,自引:0,他引:4  
Central venous catheters (CVCs) are widely used in critically ill patients in intensive care units. However, infectious complications are common and may limit their utility. We critically review the literature to determine the impact of CVC design amd composition, insertion site selection, insertion procedures, care and removal of temporary CVCs on infectious complications. Relevant articles were identified and selected for review using a database search (Medline and manual of the English language literature) based upon study design and sample size with an emphasis on prospective randomized trials. To minimize infectious complications and maintain a reasonable cost-benefit ratio, we recommend: i) use a single lumen catheter unless clear indications for a multi-lumen catheter exist; ii) insert the catheter via the subclavian vein if no relative contraindication exists (bleeding diathesis, positive pressure ventilation); iii) disinfect the insertion site employing sterile technique; iv) apply a dry, sterile dressing and change the dressing every other day; v) inspect the insertion site for signs of infection and remove the catheter if pus is present; vi) if a catheter-related infection is suspected, change the catheter over a guidewire and culture the distal segment. The replacement catheter should be removed if an original catheter segment culture is positive.  相似文献   

8.
Common usage of central venous catheter (CVC) access for haemodialysis has presented the haemodialysis nurse with the challenge of maintaining CVCs as a viable form of access. The major complications seen with CVC use are obstruction and infection. A project was undertaken to identify the usefulness of the endoluminal fibrin analysis system (FAS) brush as an intervention in haemodialysis CVC management. The aims of the study were to identify: the reasons for brushing CVCs and the number of occasions brushing is indicated; how successful brushing is in unblocking and improving flow from CVCs, and the length of time the catheter remains patent following successful declotting. Seventeen patients were found suitable for CVC brushing and divided into two groups depending on the indication for brushing. In the group in which the catheter was brushed to restore flow, 73 per cent of brushings were successful, and in 50 per cent of those cases the CVC remained patent for 6 weeks. Sixty per cent of catheter brushings to improve flow were successful, and in 50 per cent of the CVCs flow was sustained over a 6-week period. Overall, the findings support the use of the endoluminal FAS brush for the applications trialled.  相似文献   

9.
Central venous catheters (CVCs) are indispensable in modern pediatric medicine. CVCs provide secure vascular access, but are associated with a risk of severe complications, in particular bloodstream infection. We provide a review of the recent literature about the diagnostic and therapeutic challenges of catheter-related bloodstream infection (CRBSI) in children and its prevention. Variations in blood sampling and limitations in blood culturing interfere with accurate and timely diagnosis of CRBSI. Although novel molecular testing methods appear promising in overcoming some of the present diagnostic limitations of conventional blood sampling in children, they still need to solidly prove their accuracy and reliability in clinical practice. Standardized practices of catheter insertion and care remain the cornerstone of CRBSI prevention although their implementation in daily practice may be difficult. Technology such as CVC impregnation or catheter locking with antimicrobial substances has been shown less effective than anticipated. Despite encouraging results in CRBSI prevention among adults, the goal of zero infection in children is still not in range. More high-quality research is needed in the field of prevention, accurate and reliable diagnostic measures and effective treatment of CRBSI in children.  相似文献   

10.
Objective Catheter colonization is commonly used as an end point in studies on central venous catheter (CVC) infections. This study aimed at comparing the rates of catheter colonization in patients according to the administration of antibiotics at removal. Design Prospective study over a 5-year period. All patients with a CVC removed without suspicion of CVC infection were included. Setting An adult medical/surgical intensive care unit at a university teaching hospital. Patients A total of 472 patients with CVC inserted for a mean CVC duration of 6.0 ± 3.7 days were included. Methods Antibiotics at removal was defined as antibiotics administered within 48 h before CVC removal, and CVC colonization as catheter tip culture yielding ≥ 103 colony-forming units per milliliter. Interventions None. Measurements and results Of 472 patients, 302 (64%) were receiving antibiotics at removal. The number of CVC colonizations per number of CVCs inserted was 4.7% (22 of 472) and the number of CVC colonizations per 1000 CVC days was 8.0. Administration of antibiotics at removal was associated with a lower risk of CVC colonization. Irrespective of CVC duration, CVC colonization rate differed between patients with or without antibiotics at removal (Kaplan–Meier test, p = 0.04). Conclusions The proportion of patients with antibiotics at time of removal should be taken into account when interpreting the results of surveys and trials using the quantitative CVC tip culture to define CVC colonization as an end point.  相似文献   

11.
OBJECTIVE: To determine rates of catheter colonization and catheter-related bloodstream infection (CRBSI) when antiseptic-bonded central venous catheters (CVCs) and standardized daily site care are used with no predetermined interval for removal. DESIGN: Prospective observational study. SETTING: Two major trauma centers. PATIENTS: All trauma patients admitted to two major trauma centers that received a CVC from May 1996 through May 1998. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Catheters were semiquantitatively cultured to identify bacterial colonization and CRBSI. Monitored variables included total catheter days, anatomical site of catheter insertion, and area in hospital of catheter insertion. CVC tips and intracutaneous segments were semiquantitatively cultured. A total of 460 (92%) of 501 catheters placed in 324 trauma patients were evaluable, representing 95.5% of all catheter days during the study period. Rates of catheter colonization and CRBSI were 5% (5/1000 catheter days) and 1.5% (1.511000 catheter days), respectively. Subclavian catheters were in place longer than femoral or internal jugular catheters (p < .0001), but the colonization rate was significantly lower (p = .03; relative risk, 0.34; 95% confidence interval, 0.15-0.77). No differences in CRBSI rates among anatomical sites or between catheters used < or =14 days and those used >14 days were identified. CONCLUSION: Femoral and internal jugular antiseptic-bonded CVCs develop bacterial colonization earlier than subclavian CVCs. Subclavian antiseptic-bonded CVCs combined with standardized daily site care may be safely used >14 days in trauma patients.  相似文献   

12.
Objective: To determine the incidence of central catheter-related bloodstream infection (CR-BSI) and to compare patient and catheter characteristics of those with and without CR-BSI from a clinically suspected subgroup. Secondly, to assess the efficacy of the acridine orange leucocyte cytospin test (AOLC) as a rapid in situ method of detecting central venous catheter (CVC) infection. Design: One-year prospective audit. Setting: Intensive care unit/high dependency unit (ICU/HDU) and general wards of a tertiary referral hospital. Patients and participants: 400 patients with non-tunnelled CVCs. Interventions: Daily surveillance, blood culture from peripheral venepuncture, blood sample from the CVC for assessment of the AOLC test and removal of suspected CVCs were carried out on patients clinically suspected of having CR-BSI. Measurements and results: CR-BSI was diagnosed using well defined criteria. Infection rate was calculated by dividing the number of definitive catheter associated infections by the total number of appropriate catheter in situ days. The AOLC test was performed on all those with suspected CR-BSI. A total of 499 CVCs in 400 patients were assessed, representing 3014 catheter in situ days. Over 80 % of patients were from our ICU/HDU, representing 404 CVCs and 1901 catheter in situ days. A total of 49/499 (9.8 %) CVCs in the same number of patients were suspected of being infected subsequently 12/499 (2.4 %) CVCs [95 % confidence interval (CI) 1.25 to 4.16] in 12 separate patients were demonstrated to be the direct cause of the patient's BSI. Rates of CR-BSI per 1000 catheter days were 3.98 (95 % CI 2.06 to 6.96) for the whole cohort and 4.20 (95 % CI 1.81 to 8.29) for the ICU/HDU subgroup. In the group suspected of having CR-BSI, CVCs were removed unnecessarily in 55 %, and no patient or catheter variables measured were predictive of the development of CR-BSI. The AOLC test was negative in all 12 catheters subsequently shown to be the definitive cause of BSI. Conclusions: We have defined the incidence of CR-BSI in a cohort of patients from a tertiary referral hospital, the rates comparing favourably with those reported for similar populations. We were unable to demonstrate significant differences in any patient or catheter variables between those with and without CR-BSI. The AOLC test used alone was unhelpful as a method to diagnose in situ CVC infection in this patient population. Received: 26 February 1998 Accepted: 30 June 1998  相似文献   

13.
OBJECTIVES: To report a series of patients with clinically diagnosed venous air embolism (VAE) and major sequelae as a complication of the use of central venous catheters (CVCs), to survey health care professionals' practices regarding CVCs, and to implement an educational intervention for optimizing approaches to CVC insertion and removal. SETTING: Tertiary care, university-based 806-bed medical center. INTERVENTIONS: We surveyed 140 physicians and 53 critical care nurses to appraise their awareness of the proper management and complications of CVCs. We then designed, delivered, and measured the effects of a multidisciplinary educational intervention given to 106 incoming house officers. MEASUREMENTS AND MAIN RESULTS: Although most physicians (127, 91%) chose the Trendelenburg position for CVC insertion, only 42 physicians (30%) reported concern for VAE. On CVC removal, only 36 physicians (26%) cited concern for VAE. Some physicians (13, 9%) reported elevating the head of the bed during CVC removal, possibly increasing the risk of VAE. Awareness of VAE or its prevention did not correlate with the level of physician training, experience, or specialty. After the educational intervention, concern for and awareness of proper methods of prevention of VAE improved (p < .001). At 6-month follow-up, reported use of the Trendelenburg position continued, but concern cited for VAE had returned to baseline. CONCLUSIONS: There is inadequate awareness of VAE as a complication of CVC use. Focused instruction can improve appreciation of this potentially fatal complication and knowledge of its prevention, but the effect declines rapidly. To achieve a more sustained improvement, a more intensive, hands-on, periodic educational program will likely be necessary, as well as reinforcement through enhanced supervision of CVC insertion and removal practices.  相似文献   

14.
ObjectiveThe management of central venous catheter (CVC) occlusion remains an area without clear evidence-based guidelines. Studies have been conducted that compare the use of heparin and normal saline for reducing thrombosis, but the evidence is not strong enough to suggest a significant advantage of one over the other. Therefore, the study aimed to assess the effectiveness of heparin and normal saline flushing in preventing CVC occlusion in pediatric patients with cancer.Data SourcesA comprehensive search was conducted in PubMed, Web of Science, Cochrane, MEDLINE, CINAHL, Embase, World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov platform using specific keywords. The search was conducted until March 2022. Five randomized controlled trials are included in this study.ConclusionFive studies with a total of 316 pediatric cancer patients met the inclusion criteria. The studies were found to be heterogeneous due to variations in the types of cancer, heparin concentration, flushing frequency of CVCs, and methods used to measure occlusion. Despite these differences, there was no significant difference in the effect of flushing with heparin and normal saline in preventing CVC occlusion. The analysis revealed that normal saline is as effective as heparin in preventing CVC occlusion among pediatric cancer patients.Implications for Nursing PracticeThis systematic review and meta-analysis demonstrated that there is no significant difference between the use of heparin and normal saline flushing in preventing CVC occlusion among pediatric cancer patients. Considering the potential risks of heparin, the use of normal saline flushing may be recommended to prevent CVC obstruction.  相似文献   

15.
The use of central venous catheters (CVCs) has become fairly commonplace within both the hospital and community setting. The removal of these devices is often a task performed without much teaching and the procedure to follow is passed on from one nurse to another with little or no research on which to base actions. This article describes the potential complications associated with CVC removal and methods to prevent them. It will also give the nurse research-based procedures to follow when removing the various types of CVC. These written procedures should be used as a training guideline only. Practical training and supervision until competent is still required.  相似文献   

16.
Partial occlusion of indwelling central venous catheters (CVCs) developed as a clinical problem following the trend to leave CVCs in place for the duration of intravenous therapy, which can last for more than 1 year in some cases. The primary manifestation of partial catheter occlusion is the ability to infuse but not aspirate fluids through an indwelling CVC. There is evidence that the problem is at least partially related to a residue of blood products deposited within some CVCs and implanted ports each time blood is aspirated or infused. Over time, these deposits may act as a ball valve when aspiration from the CVC is attempted while still allowing fluid or drug infusions. A preliminary investigation has indicated that this partial occlusion can be corrected by the use of a fibrinolytic drug to "cleanse" the CVC of residual blood products through lysis, thus restoring full CVC patency. Controlled studies are still needed to determine how often the CVC should be cleansed to prevent buildup of blood products in the indwelling CVC.  相似文献   

17.
The aim of this study was to evaluate the acridine orange leukocyte cytospin (AOLC) test for the rapid diagnosis of septicemia caused by central venous catheters (CVCs), without removing the catheter, in a pediatric intensive care unit population. Twenty-six patients admitted in the pediatric intensive care unit of Azienda Ospedaliera "Ospedali Riuniti di Bergamo", Italy, were prospectively evaluated for CVC-related infection. Blood for culture was taken from all patients. Quantitative endoluminal cultures of the removed catheter tip by Cleri's technique and semiquantitative superficial cultures of the hub were performed. Gram staining and an AOLC smear were done according to Kite's technique. Four Staphylococcus CVC-related bloodstream infections were identified. CVC colonization was detected in 8 patients. Four had septicemia (Enterococcus faecalis, Escherichia coli, Klebsiella oxytoca, Candida glabrata) without CVC involvement. However, Gram staining and the AOLC test were negative in all cases. We conclude that cytocentrifugation and acridine orange staining of blood withdrawn by Kite's method from an in situ catheter, although simple, quick, and inexpensive, did not aid diagnosis in this pediatric population.  相似文献   

18.
Objective To find a subset of patients with suspected central venous catheter (CVC)-related infection (CRI) in whom CVC removal is not needed.Design Randomized controlled trial.Setting Thirty-three-bed ICU.Patients and participants One hundred and forty four patients with suspected CRI in which a change of CVCs was planned were evaluated for inclusion.Interventions Hemodynamically stable patients without proven bacteremia, no insertion site infection, and no intravascular foreign body were randomized to a standard-of-care group (SOC, all CVCs were changed as planned) or a watchful waiting group (WW, CVCs changed when bacteremia was subsequently confirmed or hemodynamic instability occurred).Measurement and results Study groups were compared for incidence of CVC-related bloodstream infection (CR-BSI), resolution of fever, C-reactive protein, SOFA score, duration of ICU stay, and mortality. Of 144 patients with suspected CRI, 80 patients met exclusion criteria. Sixty-four were randomized. Forty-seven of 80 excluded patients were shown to be bacteremic, 20 (25%) of whom had a CR-BSI. Five of 64 (8%) included patients had a CR-BSI during their subsequent ICU stay (two in SOC and three in WW group). All 38 CVCs were changed in the SOC group versus 16 of 42 in the WW group (62% reduction, P<0.01). Resolution of fever, C-reactive protein, SOFA score, duration of ICU stay, and ICU mortality did not differ between SOC and WW group (P>0.1 for all).Conclusions The use of a simple clinical algorithm permits a substantial decrease in the number of unnecessarily removed CVCs without increased morbidity.An editorial regarding this article can be found in the same issue ()  相似文献   

19.
Objective Central venous catheter (CVC)-related infections may be caused by micro-organisms introduced from the skin surface into deeper tissue at the time of CVC insertion. The optimal disinfection regimen to avoid catheter-related infections has not yet been defined. This study compares three different approaches.Design Prospective randomised trial.Setting A tertiary care hospital.Patients and participants One hundred nineteen patients scheduled electively to receive 140 CVCs.Interventions Skin disinfection was performed with either povidone-iodine 10% (PVP-iodine), chlorhexidine 0.5%/propanol 70%, or chlorhexidine 0.5%/propanol 70% followed by PVP-iodine 10%. Prior to disinfection, a swab from the site of insertion was taken for culture. CVCs were removed if no longer needed or infection was suspected. All catheters were cultured quantitatively after removal.Measurement and results Bacteria could be isolated from 20.7% of the catheter tips. Bacterial growth was found in 30.8% of the catheters placed after skin disinfection with povidone-iodine, in 24.4% after disinfection with propanol/chlorhexidine and in 4.7% after disinfection with propanol/chlorhexidine followed by povidone-iodine (p=0.006). In 15 cases, the same organism was isolated from the skin swab and the catheter tip. Ten of these paired isolates showed the same pattern in a pulsed-field gel electrophoresis analysis.Conclusions Skin disinfection with propanol/chlorhexidine followed by PVP-iodine was superior in the prevention of microbial CVC colonisation compared to either of the regimens alone. These results support the concept that catheter infections can originate from bacterial translocation at the time of catheter insertion.  相似文献   

20.
血液透析患者中心静脉留置导管失功原因与处理   总被引:5,自引:0,他引:5  
目的提高对中心静脉留置导管失功的认识和诊治水平,改善血液透析患者预后。方法分析156例中心静脉置管的维持性血液透析患者。采用Seldinger技术置管,其中36例为长期双腔导管,120例为临时双腔导管。结果导管失功有两大类:①导管通路功能障碍22例,原因以导管血栓形成为主(占59%),导管纤维外鞘形成是长期双腔导管功能障碍的另一个重要因素,在导管使用过程发生;于置管后即刻发生者多由导管打折、贴壁等技术因素引起;②导管相关性感染27例:糖尿病肾病(DN)患者感染发生率显著高于非DN患者;股静脉置管的感染发生率显著高于颈内静脉置管;临时导管感染发生率显著高于长期导管,且留置越久,临时导管感染发生率越高。结论导管内血栓形成是两类导管通路障碍的主要原因,长期双腔导管发生障碍的重要原因还有纤维外鞘;临时导管留置时间延长及会增加感染的机会,影响感染的因素还有糖尿病和置管部位;需长期留置导管时,应用带涤纶套的导管可明显减少感染。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号