首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe aims of this study were to determine the rate of noncentered coronary ostia and their risk for coronary overlap (CO) and to develop an improved orientation strategy for transcatheter aortic valve replacement (TAVR) devices taking into account anatomical cues to identify patients at risk for CO regardless of commissural alignment and compute an alternative, CO-free TAVR rotation angle for those patients.BackgroundCommissural alignment during TAVR reduces CO risk. However, eccentricity of coronary ostia from the center of the sinus of Valsalva may result in CO even after perfect alignment of TAVR commissures.MethodsBaseline computed tomography from TAVR candidates helped identify distance from commissures to the right coronary artery (RCA) and the left coronary artery (LCA). Then, for each case, a virtual valve was simulated with ideal commissural or coronary alignment, and the degree of CO was determined. On the basis of the potential BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) efficacy, 3 groups were defined: no risk for CO (>35° from neocommissure to coronary ostia), moderate risk (20°-35°), and severe risk (≤20°).ResultsComputed tomographic studies from 107 patients were included. After excluding 7 patients (poor quality or bicuspid valve), 100 patients were analyzed. The RCA showed greater eccentricity compared with the LCA (18.5° [IQR: 3.3°-12.8°] vs 6.5° [IQR: 3.3°-12.8°]; P < 0.001). The mean intercoronary angle was 140.0° ± 18.7° (95% CI: 136.3°-143.7°). Thirty-two patients had moderate to severe risk for CO (≤35°) despite ideal commissural alignment. Greater coronary eccentricity (cutoff for RCA, 24.5°; cutoff for LCA, 19°) and intercoronary angle >147.5° or <103° were associated with greater risk for moderate to severe CO despite commissural alignment (area under the curve: 0.97; 95% CI: 0.91-0.99). If optimal coronary alignment was simulated, this prevented severe CO in all cases and reduced moderate CO from 27% to 5% (P < 0.001).ConclusionsOne third of patients would have CO during TAVR-in-TAVR despite commissural alignment; a 6-fold decrease in this risk was achieved with optimized coronary alignment. Coronary eccentricity and intercoronary angle were the main predictors.  相似文献   

2.
ObjectivesThe authors sought to investigate whether a patient-specific implantation technique during transcatheter aortic valve replacement (TAVR) can result in a safe and reproducible neo-commissural alignment of self-expanding transcatheter heart valves (THVs).BackgroundTo date, little attention has been paid to neo-commissural alignment during TAVR.MethodsA fluoroscopy-based, patient- and valve-specific TAVR implantation technique was applied in 60 patients treated with 3 different self-expanding THV platforms (Evolut R/PRO, Medtronic; ACURATE neo2, Boston Scientific; and Portico, Abbott—20 patients in each group). Post-TAVR cardiac computed tomography was used to assess THV neo-commissural alignment.ResultsConsidering all 60 patients, ≤mild commissural misalignment (CMA <30°) was obtained in 53 patients (88%) using this modified TAVR implantation technique—in 36 patients (60%), optimal commissural alignment (<15°) was obtained. In 2 patients, cardiac computed tomography revealed severe CMA (>45°) with overlap between the coronary ostia and THV commissures. Using the ACURATE neo2 platform, operators succeeded in avoiding ≥moderate CMA in all 20 cases. When analyzing those cases in which the optimal amount of THV rotation could be assessed and applied before THV expansion (n = 52; 87%), the success rate of TAVR with ≤mild CMA was 98%. No procedure- or valve-related complications occurred in this study cohort.ConclusionsA patient-specific TAVR implantation technique aiming to obtain neo-commissural alignment is feasible and safe, and aides to prevent THV implantations with overlap between the coronary ostia and THV commissures. Optimized TAVR devices and design may further improve the success rate of TAVR with neo-commissural alignment.  相似文献   

3.
ObjectivesThe aims of this study were to investigate the feasibility of coronary ostia cannulation after transcatheter aortic valve replacement (TAVR) and to assess potential predictors of coronary access impairment.BackgroundCertain data concerning the feasibility and reproducibility of coronary cannulation after TAVR are lacking.MethodsRE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent) was an investigator-driven, single-center, prospective, registry-based study that enrolled consecutive patients undergoing TAVR using all commercially available devices. All patients underwent coronary angiography before and after TAVR. The primary endpoint was the rate of unsuccessful coronary ostia cannulation after TAVR. Secondary endpoints were the identification of factors associated with the inability to selectively cannulate coronary ostia after TAVR.ResultsAmong 300 patients enrolled in the RE-ACCESS study from December 2018 to January 2020, a total of 23 cases (7.7%) of unsuccessful coronary cannulation after TAVR were documented. This issue occurred in 22 of 23 cases with the use of Evolut R/PRO transcatheter aortic valves (TAVs) (17.9% vs. 0.4%; p < 0.01). In multivariate analysis, the use of Evolut R/PRO TAVs (odds ratio [OR]: 29.6; 95% confidence interval [CI]: 2.6 to 335.0; p < 0.01), the TAV–sinus of Valsalva relation (OR: 1.1 per 1-mm increase; 95% CI: 1.0 to 1.2; p < 0.01), and the mean TAV implantation depth (OR: 1.7 per 1-mm decrease; 95% CI: 1.3 to 2.3; p < 0.01) were found to be independent predictors of unsuccessful coronary cannulation after TAVR. A model combining these factors was demonstrated to predict with very high accuracy the risk for unsuccessful coronary cannulation after TAVR (area under the curve: 0.94; p < 0.01).ConclusionsUnsuccessful coronary cannulation following TAVR was observed in 7.7% of patients and occurred almost exclusively in those receiving Evolut TAVs. The combination of Evolut TAV, a higher TAV–sinus of Valsalva relation, and implantation depth predicts with high accuracy the risk for unsuccessful coronary cannulation after TAVR. (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent [RE-ACCESS]; NCT04026204)  相似文献   

4.
ObjectivesThe aim of this study was to evaluate the impact of initial deployment orientation of SAPIEN 3, Evolut, and ACURATE-neo transcatheter heart valves on their final orientation and neocommissural overlap with coronary arteries.BackgroundCoronary artery access and redo transcatheter aortic valve replacement (TAVR) following initial TAVR may be influenced by transcatheter heart valve orientation. In this study the impact of transcatheter heart valve deployment orientation on commissural alignment was evaluated.MethodsPre-TAVR computed tomography and procedural fluoroscopy were analyzed in 828 patients who underwent TAVR (483 SAPIEN 3, 245 Evolut, and 100 ACURATE-neo valves) from March 2016 to September 2019 at 5 centers. Coplanar fluoroscopic views were coregistered to pre-TAVR computed tomography to determine commissural alignment. Severe overlap between neocommissural posts and coronary arteries was defined as 0° to 20° apart. The SAPIEN 3 had 1 commissural post crimped at 3, 6, 9, and 12 o’clock. The Evolut “Hat” marker and ACURATE-neo commissural post at deployment were classified as center back (CB), inner curve (IC), outer curve (OC), or center front (CF) and matched with final orientation.ResultsInitial SAPIEN 3 crimped orientation had no impact on commissural alignment. Evolut “Hat” at OC or CF at initial deployment had less severe overlap than IC or CB (p < 0.001) against the left main (15.7% vs. 66.0%) and right coronary (7.1% vs. 51.1%) arteries. Tracking Evolut “Hat” at OC of the descending aorta (n = 107) improved OC at deployment from 70.2% to 91.6% (p = 0.002) and reduced coronary artery overlap by 36% to 60% (p < 0.05). ACURATE-neo commissural post at CB or IC during deployment had less coronary artery overlap compared to CF or OC (p < 0.001), with intentional alignment successful in 5 of 7 cases.ConclusionsThis is the first systematic evaluation of commissural alignment in TAVR. More than 30% to 50% of cases had overlap with 1 or both coronary arteries. Initial SAPIEN 3 orientation had no impact on alignment, but specific initial orientations of Evolut and ACURATE improved alignment. Optimizing valve alignment to avoid coronary artery overlap will be important in coronary artery access and redo TAVR.  相似文献   

5.
ObjectivesThe aim of this study was to assess the incidence of unfavorable coronary access after transcatheter aortic valve replacement (TAVR) using post-implantation computed tomography (CT).BackgroundReal-world data regarding coronary access after TAVR assessed using post-implantation CT are scarce.MethodsPost-TAVR CT of 66 patients treated with Evolut R or Evolut PRO valves and 345 patients treated with SAPIEN 3 valves were analyzed. The distance from inflow of the transcatheter heart valve (THV) to the coronary ostia and the overlap between THV commissures and the coronary ostia were assessed. Coronary access was defined as unfavorable if the coronary ostium was below the skirt or in front of the THV commissural posts above the skirt in each coronary artery.ResultsCT-identified features of unfavorable coronary access were observed in 34.8% (n = 23) for the left coronary artery and 25.8% (n = 17) for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 15.7% (n = 54) for the left coronary artery and 8.1% (n = 28) for the right coronary artery in the SAPIEN 3 group. In the Evolut R/Evolut PRO group, 16 coronary engagements were performed after TAVR, while 64 coronary engagements were performed in the SAPIEN 3 group after TAVR. In an engagement-level analysis, the success rates of selective coronary engagement were significantly lower in patients with CT-identified features of unfavorable coronary access compared with those with favorable coronary access in both the Evolut R/Evolut PRO (0.0% vs. 77.8%; p = 0.003) and SAPIEN 3 (33.3% vs. 91.4%; p = 0.003) groups.ConclusionsCoronary access may be challenging in a significant proportion of patients after TAVR. THVs with low skirt or commissure height and large open cells that are designed to achieve commissure-to-commissure alignment with the native aortic valve may facilitate future coronary access. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

6.
ObjectivesThe aim of this study was to define the optimal fluoroscopic viewing angles of both coronary ostia and important coronary bifurcations by using 3-dimensional multislice computed tomographic data.BackgroundOptimal fluoroscopic projections are crucial for coronary imaging and interventions. Historically, coronary fluoroscopic viewing angles were derived empirically from experienced operators.MethodsIn this analysis, 100 consecutive patients who underwent computed tomographic coronary angiography (CTCA) for suspected coronary artery disease were studied. A CTCA-based method is described to define optimal viewing angles of both coronary ostia and important coronary bifurcations to guide percutaneous coronary interventions.ResultsThe average optimal viewing angle for ostial left main stenting was left anterior oblique (LAO) 37°, cranial (CRA) 22° (95% confidence interval [CI]: LAO 33° to 40°, CRA 19° to 25°) and for ostial right coronary stenting was LAO 79°, CRA 41° (95% CI: LAO 74° to 84°, CRA 37° to 45°). Estimated mean optimal viewing angles for bifurcation stenting were as follows: left main: LAO 0°, caudal (CAU) 49° (95% CI: right anterior oblique [RAO] 8° to LAO 8°, CAU 43° to 54°); left anterior descending with first diagonal branch: LAO 11°, CRA 71° (95% CI: RAO 6° to LAO 27°, CRA 66° to 77°); left circumflex bifurcation with first marginal branch: LAO 24°, CAU 33° (95% CI: LAO 15° to 33°, CAU 25° to 41°); and posterior descending artery and posterolateral branch: LAO 44°, CRA 34° (95% CI: LAO 35° to 52°, CRA 27° to 41°).ConclusionsCTCA can suggest optimal fluoroscopic viewing angles of coronary artery ostia and bifurcations. As the frequency of use of diagnostic CTCA increases in the future, it has the potential to provide additional information for planning and guiding percutaneous coronary intervention procedures.  相似文献   

7.
ObjectivesThis study sought to predict whether different methods of calculating the implantation depth (ID) influence clinical and hemodynamic outcome reporting in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expandable device.BackgroundDifferent approaches exist to calculate the ID, which may influence uniform and reliable reporting because the updated Valve Academic Research Consortium (VARC-2) criteria do not provide specific instructions.MethodsThe clinical and hemodynamic outcomes of 258 patients undergoing TAVR with a third-generation self-expandable device were analyzed with regard to the method used to assess the ID as follows: arithmetic mean, the arithmetic mean of the measured distances from the noncoronary cusp and the left coronary cusp to the distal prosthesis end; noncoronary cusp distance, the distance from the noncoronary cusp to the distal prosthesis end; and deepest edge, the deepest edge of the distal prosthesis end.ResultsRegardless of the measurement method, the optimal ID (OID) was reached in <30% (arithmetic mean, 25.4%; noncoronary cusp distance, 28.4%; deepest edge, 20.5%; p = 0.008). The deepest edge method is the most stringent to differentiate the relevant outcome parameters, such as the need for permanent pacemaker implantation (OID 3.7% vs. no OID 14.6%; p = 0.033). The hemodynamic outcome (i.e., mean pressure gradient reduction after TAVR: OID 7.4 ± 3.4 mm Hg vs. no OID 8.3 ± 4.0 mm Hg; p = 0.093) was not affected.ConclusionsThe OID was reached in <30% of TAVR procedures. The various methods applied for ID calculation significantly influence the outcome reporting and do not allow a uniform perception of the ID. (Multi Modal Cardiac Imaging Prior Transcatheter Aortic Valve Implantation; NCT01805739)  相似文献   

8.
ObjectivesThe aim of this study was to investigate the safety and efficacy of coronary protection by preventive coronary wiring and stenting across the coronary ostia in patients at high risk for coronary obstruction after transcatheter aortic valve replacement (TAVR).BackgroundCoronary obstruction following TAVR is a life-threatening complication with high procedural and short-term mortality.MethodsData were collected retrospectively from a multicenter international registry between April 2011 and February 2019.ResultsAmong 236 patients undergoing coronary protection with preventive coronary wiring, 143 had eventually stents implanted across the coronary ostia after valve deployment. At 3-year follow-up, rates of cardiac death were 7.8% in patients receiving stents and 15.7% in those not receiving stents (adjusted hazard ratio: 0.42; 95% confidence interval: 0.14 to 1.28; p = 0.13). There were 2 definite stent thromboses (0.9%) in patients receiving stents, both occurring after TAVR in “valve-in-valve” procedures. In patients not receiving stents, there were 4 delayed coronary occlusions (DCOs) (4.3%), occurring from 5 min to 6 h after wire removal. Three cases occurred in valve-in-valve procedures and 1 in a native aortic valve procedure. Distance between the virtual transcatheter valve and the protected coronary ostia <4 mm was present in 75.0% of patients with DCO compared with 30.4% of patients without DCO (p = 0.19).ConclusionsIn patients undergoing TAVR at high risk for coronary obstruction, preventive stent implantation across the coronary ostia is associated with good mid-term survival rates and low rates of stent thrombosis. Patients undergoing coronary protection with wire only have a considerable risk for DCO.  相似文献   

9.
BackgroundIt is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs).ObjectivesThe aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs.MethodsIn this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes.ResultsA total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women.ConclusionsIn patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.  相似文献   

10.
ObjectivesThe aim of this study was to evaluate the risk of coronary obstruction due to sinus sequestration in redo transcatheter aortic valve replacement (TAVR) using post-TAVR computed tomography (CT).BackgroundLittle information is available regarding the risk of coronary obstruction due to sinus sequestration in redo TAVR inside a previously implanted TAV.MethodsPost-TAVR CT of 66 patients who received an Evolut R or Evolut PRO and 345 patients who received a SAPIEN 3 were analyzed. Redo TAVR was considered at risk of coronary obstruction due to sinus sequestration if: 1) the prior TAV commissure level was above sinotubular junction (STJ); and 2) the distance between TAV and STJ was <2.0 mm in each coronary sinus.ResultsIn total, 45.5% in the Evolut R/Evolut PRO group and 2.0% in the SAPIEN 3 group had CT-identified risk of sinus sequestration at 1 or both coronary arteries (p < 0.001). CT-identified risk of sinus sequestration was observed in 39.4% for the left coronary artery and 24.2% for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 2.0% for the left coronary artery and 0.6% for the right coronary artery in the SAPIEN 3 group. In a coronary-level analysis, overlaps between the first TAV commissural posts and coronary ostium were observed in 45.2% in the Evolut R/Evolut PRO group and 11.1% in in the SAPIEN 3 group among coronary arteries at CT-identified risk of sinus sequestration.ConclusionsThe risk of sinus sequestration in redo TAVR should be carefully screened by CT, especially in patients with low STJ height. TAV with low commissure height that was designed to achieve commissure-to-commissure alignment with the native aortic valves may be preferable to avoid the risk of coronary obstruction due to sinus sequestration and allow for a preventive leaflet laceration procedure in future redo TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

11.
BackgroundTranscatheter aortic valve replacement (TAVR)–related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies.ObjectivesThis study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis.MethodsPreprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort.ResultsSixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right.ConclusionsA novel computed tomography–based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.  相似文献   

12.
ObjectivesThe aim of this study was to examine the predictive value of preprocedural computed tomography (CT)–based risk stratification of coronary obstruction during transcatheter aortic valve replacement (TAVR) on the basis of geometric measurements on postprocedural CT.BackgroundProper patient selection for additional procedures to prevent coronary obstruction during TAVR has not been adequately evaluated.MethodsPre- and postprocedural computed tomographic scans of 28 patients treated using bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and TAVR were analyzed. Using the postprocedural computed tomographic images, threatened coronary obstruction (TCO) was defined as: 1) ostial obstruction (adherence of the transcatheter heart valve [THV] to the coronary ostium with leaflet extension above the ostium); and/or 2) sinus sequestration (THV adherence to the sinotubular junction [STJ] with leaflet extension above the STJ) and was substratified into complete and incomplete types.ResultsA total of 51 leaflets were evaluated (88% surgical tissue valves) after excluding leaflets not visible on CT (n = 5). On postprocedural CT, complete TCO was observed in 25.4% (13 of 51 leaflets). On preprocedural CT, leaflets were at high risk for complete TCO (incidence 53%) if the virtual THV–to–coronary distance (VTC) was <3.0 mm, or if the virtual THV–to–STJ distance (VTSTJ) was <1.0 mm with STJ height ? leaflet length <0 mm (leaflet-STJ mismatch). Leaflets were at low risk (incidence 0%) if the VTC was ≥3 mm and VTSTJ was ≥3.0 mm or STJ height ? leaflet length was ≥+2.0 mm. Of 28 leaflets treated using BASILICA, complete TCO was seen in 35.7% (n = 10), due to sinus sequestration (100%) with coexisting ostial obstruction (30%). Actual coronary events occurred in 7.1% (n = 2) because of leaflet prolapse, corresponding to an absolute risk reduction by BASILICA of 29% (P = 0.021).ConclusionsRisk assessment of coronary obstruction after TAVR may improve with a multiparametric approach incorporating VTC, VTSTJ, and leaflet-STJ mismatch. BASILICA appeared to reduce actual coronary events even in leaflets with anticipated coronary obstruction.  相似文献   

13.
ObjectivesThe authors sought to estimate possible interference of the Medtronic Evolut R/Pro transcatheter heart valve (THV) frame with coronary access using multislice computed tomography (MSCT) data.BackgroundLower-risk patients undergoing transcatheter aortic valve replacement (TAVR) endure a high cumulative risk of coronary events, but coronary access can be challenging.MethodsIn 101 patients who received an Evolut R/Pro THV, post-TAVR MSCT (performed at a median of 30 days after TAVR) was used to assess possible interference of the elements of the THV frame with coronary access.ResultsThe closest cell of the THV frame vertically aligned with the coronary ostium was located opposite the ostium in 58% and 63%, below the ostium in 22% and 30%, or above the ostium in 20% and 7% of left and right coronary arteries, respectively. The free sinus of Valsalva space between the THV frame and the coronary ostium was 0.45 ± 0.17 cm and 0.44 ± 0.17 cm for the left and right coronary arteries, respectively, and showed a stepwise decrease with decreasing THV size (p < 0.001). Bioprosthetic valve commissures were antianatomic (i.e., not aligned with native commissures) in 45 patients (47%), and the commissural post was overlapping a coronary ostium in 15 patients (16%). Two patients (2.0%) had a possible interference of the paravalvular sealing skirt with coronary access.ConclusionsUsing post-TAVR MSCT data, the main mechanism of potential interference of Evolut R/Pro frame with coronary access was an antianatomic commissural post overlapping the coronary ostium.  相似文献   

14.
ObjectivesThe purpose of this study was to assess the concordance between transcatheter aortic valve implantation angles generated by the “double S-curve” and “cusp-overlap” techniques.BackgroundThe “double S-curve” and “cusp-overlap” methods aim to define optimal fluoroscopic projections for transcatheter aortic valve replacement (TAVR) with a self-expandable device.MethodsThe study included 100 consecutive patients undergoing TAVR with self-expanding device planned by multidetector computed tomography. TAVR was performed using the double S-curve model, as a view in which both the aortic valve annulus and delivery catheter planes are displayed perpendicularly on fluoroscopy. Optimal projection according to the cusp-overlap technique was retrospectively generated by overlapping the right and left cups on the multidetector computed tomography annular plane. The angular difference between methods was assessed in spherical 3 dimensions and on the left and right anterior oblique (RAO) and cranial and caudal (CAU) axes.ResultsThe double S-curve and cusp-overlap methods provided views located in the same quadrant, mostly the RAO and CAU, in 92% of patients with a median 3-dimensional angular difference of 10.0° (interquartile range: 5.5° to 17.9°). The 3-dimensional deviation between the average angulation obtained by each method was not statistically significant (1.49°; p = 0.349). No significant differences in average coordinates were noted between the double S-curve and cusp-overlap methods (RAO: 14.7 ± 15.2 vs. 12.9 ± 12.5; p = 0.36; and CAU: 27.0 ± 9.4 vs. 26.9 ± 10.4; p = 0.90). TAVR using the double S-curve was associated with 98% device success, low complication rate, and absence of moderate-to-severe paravalvular leak.ConclusionsThe double S-curve and cusp-overlap methods provide comparable TAVR projections, mostly RAO and CAU. TAVR using the double S-curve model is associated with a high rate of device success and low rate of procedural complications.  相似文献   

15.
ObjectivesThe aim of this study was to characterize the feasibility of coronary angiography (CA) and percutaneous coronary intervention (PCI) in acute settings among patients who have undergone transcatheter aortic valve replacement (TAVR).BackgroundImpaired coronary access after TAVR may be challenging and particularly in acute settings could have deleterious consequences.MethodsIn this international registry, data from patients with prior TAVR requiring urgent or emergent CA were retrospectively collected. A total of 449 patients from 25 sites with acute coronary syndromes (89.1%) and other acute cardiovascular situations (10.9%) were included.ResultsSuccess rates were high for CA of the right coronary artery (98.3%) and left coronary artery (99.3%) and were higher among patients with short stent-frame prostheses (SFPs) than in those with long SFPs for CA of the right coronary artery (99.6% vs 95.9%; P = 0.005) but not for CA of the left coronary artery (99.7% vs 98.7%; P = 0.24). PCI of native coronary arteries was successful in 91.4% of cases and independent of valve type (short SFP 90.4% vs long SFP 93.4%; P = 0.44). Guide engagement failed in 6 patients, of whom 3 underwent emergent coronary artery bypass grafting and another 3 died in the hospital. Among patients requiring revascularization of native vessels, independent predictors of 30-day all-cause mortality were prior diabetes, cardiogenic shock, and failed PCI but not valve type or success of coronary engagement.ConclusionsCA or PCI after TAVR in acute settings is usually successful, but selective coronary engagement may be more challenging in the presence of long SFPs. Among patients requiring PCI, prior diabetes, cardiogenic shock, and failed PCI were predictors of early mortality.  相似文献   

16.
BackgroundAmong patients with acute coronary syndrome following transcatheter aortic valve replacement (TAVR), those presenting with ST-segment elevation myocardial infarction (STEMI) are at highest risk.ObjectivesThe goal of this study was to determine the clinical characteristics, management, and outcomes of STEMI after TAVR.MethodsThis was a multicenter study including 118 patients presenting with STEMI at a median of 255 days (interquartile range: 9 to 680 days) after TAVR. Procedural features of STEMI after TAVR managed with primary percutaneous coronary intervention (PCI) were compared with all-comer STEMI: 439 non-TAVR patients who had primary PCI within the 2 weeks before and after each post-TAVR STEMI case in 5 participating centers from different countries.ResultsMedian door-to-balloon time was higher in TAVR patients (40 min [interquartile range: 25 to 57 min] vs. 30 min [interquartile range: 25 to 35 min]; p = 0.003). Procedural time, fluoroscopy time, dose-area product, and contrast volume were also higher in TAVR patients (p < 0.01 for all). PCI failure occurred more frequently in patients with previous TAVR (16.5% vs. 3.9%; p < 0.001), including 5 patients in whom the culprit lesion was not revascularized owing to coronary ostia cannulation failure. In-hospital and late (median of 7 months [interquartile range: 1 to 21 months]) mortality rates were 25.4% and 42.4%, respectively (20.6% and 38.2% in primary PCI patients), and estimated glomerular filtration rate <60 ml/min (hazard ratio [HR]: 3.02; 95% confidence interval [CI]: 1.42 to 6.43; p = 0.004), Killip class ≥2 (HR: 2.74; 95% CI: 1.37 to 5.49; p = 0.004), and PCI failure (HR: 3.23; 95% CI: 1.42 to 7.31; p = 0.005) determined an increased risk.ConclusionsSTEMI after TAVR was associated with very high in-hospital and mid-term mortality. Longer door-to-balloon times and a higher PCI failure rate were observed in TAVR patients, partially due to coronary access issues specific to the TAVR population, and this was associated with poorer outcomes.  相似文献   

17.
ObjectivesThe aim of this study was to evaluate the feasibility of coronary access and aortic valve reintervention in low-risk patients undergoing transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter heart valve (THV).BackgroundYounger, low-risk TAVR patients are more likely than older, higher risk patients to require coronary angiography, percutaneous coronary intervention, or aortic valve reintervention, but their THVs may impede coronary access and cause coronary obstruction during TAVR-in-TAVR.MethodsThe LRT (Low Risk TAVR) trial (NCT02628899) enrolled 200 subjects with symptomatic severe aortic stenosis to undergo TAVR using commercially available THVs. Subjects who received balloon-expandable THVs and who had 30-day cardiac computed tomographic scans were included in this study. In a subgroup, the feasibility of intentional THV crimping on the delivery catheter to pre-determine commissural alignment was tested.ResultsIn the LRT trial, 168 subjects received balloon-expandable THVs and had 30-day cardiac computed tomographic scans, of which 137 were of adequate image quality for analysis. The most challenging anatomy for coronary access (THV frame above and commissural suture post in front of a coronary ostium) was observed in 9% to 13% of subjects. Intentional THV crimping did not appear to meaningfully affect commissural alignment. The THV frame extended above the sinotubular junction in 21% of subjects, and in 13%, the distance between the THV and the sinotubular junction was <2 mm, signifying that TAVR-in-TAVR may not be feasible without causing coronary obstruction.ConclusionsTAVR may present challenges to future coronary access and aortic valve reintervention in a substantial number of low-risk patients.  相似文献   

18.
BackgroundCoronary access may be challenging following transcatheter aortic valve replacement (TAVR) in the setting of transcatheter heart valve (THV) commissural misalignment.ObjectivesThe authors aimed to quantify the degree of commissural alignment following balloon-expandable THV implantation using a fluoroscopy-based trigonometric approach and assess its correlation with post-TAVR computed tomography (CT).MethodsTwenty patients who had undergone both TAVR with the balloon-expandable SAPIEN 3 THV and post-TAVR CT were included in the analysis. Optimized, predeployment 3-cusp angiographic view and postdeployment angiographic view using identical fluoroscopic projections were required. The distance between the most central posterior commissural strut and the THV centerline was assessed. Commissural alignment was calculated by means of a trigonometrical approach using an arcsine function, assuming circular deployment of the THV. Commissural alignment was stratified using a 4-tier scale: aligned (0° to 15°); mildly misaligned (15° to 30°); moderately misaligned (30° to 45°), and severely misaligned (45° to 60°).ResultsSeven patients (35.0%) were misclassified by 1 tier, and no patient was misclassified by 2 or more tiers, with strong agreement between CT and fluoroscopy (weighted Cohen’s kappa coefficient = 0.724). Correlation of the commissural offset angle determined from fluoroscopy and CT was excellent (r = 0.986; 95% CI: 0.965 to 0.995). Bland-Altman analysis demonstrated a strong agreement between both modalities with a mean difference of 0.5° (95% limits of agreement: ?12.7° to 13.7°).ConclusionsThe degree of commissural alignment of the balloon-expandable THV can be reliably assessed and quantified on postdeployment fluoroscopy using a standardized 3-cusp view and trigonometry-based analysis.  相似文献   

19.
ObjectivesThe purpose of this study was to evaluate the safety and efficacy of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) for stentless bioprosthetic aortic valves (SBAVs) and to identify predictors of adverse events.BackgroundViV TAVR in SBAVs is associated with unique technical challenges and risks.MethodsClinical records and computer tomographic scans were retrospectively reviewed for procedural complications, predictors of coronary obstruction, mortality, and echocardiographic results.ResultsAmong 66 SBAV patients undergoing ViV TAVR, mortality was 2 of 66 patients (3.0%) at 30 days and 5 of 52 patients (9.6%) at 1 year. At 1 year, left ventricular end-systolic dimension was decreased versus baseline (median [interquartile range (IQR)]: 3.0 [2.6 to 3.6] cm vs. 3.7 [3.2 to 4.4] cm; p < 0.001). Coronary occlusion in 6 of 66 procedures (9.1%) resulted in myocardial infarction in 2 of 66 procedures (3.0%). Predictors of coronary occlusion included subcoronary implant technique compared with full root replacement (6 of 31, 19.4% vs. 0 of 28, 0%; p = 0.01), short simulated radial valve-to-coronary distance (median [IQR]: 3.4 [0.0 to 4.6] mm vs. 4.6 [3.2 to 6.2] mm; p = 0.016), and low coronary height (7.8 [5.8 to 10.0] mm vs. 11.6 [8.7 to 13.9] mm; p = 0.003). Coronary arteries originated <10 mm above the valve leaflets in 34 of 97 unobstructed coronary arteries (35.1%).ConclusionsTAVR in SBAVs is frequently associated with high-risk coronary anatomy but can be performed with a low risk of death and myocardial infarction, resulting in favorable ventricular remodeling. A subcoronary surgical approach is associated with an increased risk of coronary obstruction.  相似文献   

20.
ObjectivesThis study sought to minimize the risk of permanent pacemaker implantation (PPMI) with contemporary repositionable self-expanding transcatheter aortic valve replacement (TAVR).BackgroundSelf-expanding TAVR traditionally carries a high risk of PPMI. Limited data exist on the use of the repositionable devices to minimize this risk.MethodsAt NYU Langone Health, 248 consecutive patients with severe aortic stenosis underwent TAVR under conscious sedation with repositionable self-expanding TAVR with a standard approach to device implantation. A detailed analysis of multiple factors contributing to PPMI was performed; this was used to generate an anatomically guided MInimizing Depth According to the membranous Septum (MIDAS) approach to device implantation, aiming for pre-release depth in relation to the noncoronary cusp of less than the length of the membranous septum (MS).ResultsRight bundle branch block, MS length, largest device size (Evolut 34 XL; Medtronic, Minneapolis, Minnesota), and implant depth > MS length predicted PPMI. On multivariate analysis, only implant depth > MS length (odds ratio: 8.04; 95% confidence interval: 2.58 to 25.04; p < 0.001) and Evolut 34 XL (odds ratio: 4.96; 95% confidence interval: 1.68 to 14.63; p = 0.004) were independent predictors of PPMI. The MIDAS approach was applied prospectively to a consecutive series of 100 patients, with operators aiming to position the device at a depth of < MS length whenever possible; this reduced the new PPMI rate from 9.7% (24 of 248) in the standard cohort to 3.0% (p = 0.035), and the rate of new left bundle branch block from 25.8% to 9% (p < 0.001).ConclusionsUsing a patient-specific MIDAS approach to device implantation, repositionable self-expanding TAVR achieved very low and predictable rates of PPMI which are significantly lower than previously reported with self-expanding TAVR.  相似文献   