首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
ObjectivesThe aim of this study was to assess cusp symmetry and coronary ostial eccentricity and its impact on coronary access following transcatheter aortic valve replacement (TAVR) using a patient-specific commissural alignment implantation technique.BackgroundTAVR implantation techniques to obtain neocommissural alignment have been introduced. The impact of cusp symmetry and coronary ostial eccentricity on coronary access after TAVR remains unknown.MethodsCardiac computed tomographic scans from 200 tricuspid aortic valves (TAVs) and 200 type 1 bicuspid aortic valves (BAVs) were studied. Cusp symmetry and coronary ostial eccentricity were assessed. In addition, the right coronary cusp/left coronary cusp and right coronary artery (RCA)/left coronary artery (LCA) ostia overlap views were calculated and compared.ResultsSevere cusp asymmetry (>135°) was more frequent in BAVs (52.5%) than in TAVs (2.5%) (P < 0.001), with the noncoronary cusp being the most common dominant cusp. The RCA ostium was found to be more often eccentric (>20°) than the LCA ostium (28% vs 6%, respectively; P < 0.001). Considering the right/left cusp overlap view, there was <20° deviation between the right coronary cusp–left coronary cusp centered line and the RCA-LCA centered line in 95% of all patients (TAV, 97%; BAV, 93%). The right/left cusp and coronary ostia overlap view differed by <10° and <20° fluoroscopic angulation in 75% and 98% of all cases, respectively.ConclusionsUsing the right/left cusp overlap view to obtain commissural alignment in TAVR is also an effective approach to implant one of the transcatheter heart valve commissures in the near center between both coronary ostia in most TAVs and type 1 BAVs. Preprocedural CT assessment remains crucial to assess cusp symmetry and coronary ostial eccentricity.  相似文献   

2.
ObjectivesThe aim of this study was to assess the incidence of unfavorable coronary access after transcatheter aortic valve replacement (TAVR) using post-implantation computed tomography (CT).BackgroundReal-world data regarding coronary access after TAVR assessed using post-implantation CT are scarce.MethodsPost-TAVR CT of 66 patients treated with Evolut R or Evolut PRO valves and 345 patients treated with SAPIEN 3 valves were analyzed. The distance from inflow of the transcatheter heart valve (THV) to the coronary ostia and the overlap between THV commissures and the coronary ostia were assessed. Coronary access was defined as unfavorable if the coronary ostium was below the skirt or in front of the THV commissural posts above the skirt in each coronary artery.ResultsCT-identified features of unfavorable coronary access were observed in 34.8% (n = 23) for the left coronary artery and 25.8% (n = 17) for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 15.7% (n = 54) for the left coronary artery and 8.1% (n = 28) for the right coronary artery in the SAPIEN 3 group. In the Evolut R/Evolut PRO group, 16 coronary engagements were performed after TAVR, while 64 coronary engagements were performed in the SAPIEN 3 group after TAVR. In an engagement-level analysis, the success rates of selective coronary engagement were significantly lower in patients with CT-identified features of unfavorable coronary access compared with those with favorable coronary access in both the Evolut R/Evolut PRO (0.0% vs. 77.8%; p = 0.003) and SAPIEN 3 (33.3% vs. 91.4%; p = 0.003) groups.ConclusionsCoronary access may be challenging in a significant proportion of patients after TAVR. THVs with low skirt or commissure height and large open cells that are designed to achieve commissure-to-commissure alignment with the native aortic valve may facilitate future coronary access. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

3.
BackgroundLimited evidence is available regarding valve-in-valve (VIV) intervention with the ACURATE neo transcatheter heart valve (THV). Low implantation has demonstrated leaflet interaction between the surgical bioprosthesis and the THV, leading to impaired hydrodynamic performance. It is unknown if commissural alignment (CA) can affect this phenomenon. Novel techniques have now been developed to achieve CA with the ACURATE neo THV.ObjectivesThe aim of this study was to assess the impact of commissural misalignment (CMA) on hydrodynamic function following VIV intervention with the ACURATE neo THV using a bench model.MethodsVIV intervention was performed with the ACURATE neo (a self-expanding THV with supra-annular leaflet position) implanted deep in the surgical bioprosthetic aortic valve (Mitroflow). Hydrodynamic function at CA (0°) and 3 different degrees of CMA (30°, 60°, and 90°) was tested. As per the International Organization for Standardization, a regurgitant fraction <20% is considered optimal.ResultsFollowing VIV, the central THV regurgitant fraction at 0°, 30°, 60°, and 90° of CMA was 8.6% ± 2.0%, 30.3% ± 12.0%, 42.6% ± 11.9%, and 66.7% ± 25.4% (P < 0.0001), respectively. On high-speed video there was no evidence of leaflet interaction at CA, whereas at 30°, 60°, and 90° of CMA there was clear evidence of THV leaflet interaction with those of the surgical valve, leading to impaired leaflet closure and to severe central THV regurgitation.ConclusionsIn VIV using the ACURATE neo THV at deep implantation, increasing degree of CMA was associated with THV leaflet interaction with those of the surgical valve and worsening regurgitant fraction. THV leaflet interaction was prevented when there was CA.  相似文献   

4.
ObjectivesThe aim of this study was to characterize the feasibility of coronary angiography (CA) and percutaneous coronary intervention (PCI) in acute settings among patients who have undergone transcatheter aortic valve replacement (TAVR).BackgroundImpaired coronary access after TAVR may be challenging and particularly in acute settings could have deleterious consequences.MethodsIn this international registry, data from patients with prior TAVR requiring urgent or emergent CA were retrospectively collected. A total of 449 patients from 25 sites with acute coronary syndromes (89.1%) and other acute cardiovascular situations (10.9%) were included.ResultsSuccess rates were high for CA of the right coronary artery (98.3%) and left coronary artery (99.3%) and were higher among patients with short stent-frame prostheses (SFPs) than in those with long SFPs for CA of the right coronary artery (99.6% vs 95.9%; P = 0.005) but not for CA of the left coronary artery (99.7% vs 98.7%; P = 0.24). PCI of native coronary arteries was successful in 91.4% of cases and independent of valve type (short SFP 90.4% vs long SFP 93.4%; P = 0.44). Guide engagement failed in 6 patients, of whom 3 underwent emergent coronary artery bypass grafting and another 3 died in the hospital. Among patients requiring revascularization of native vessels, independent predictors of 30-day all-cause mortality were prior diabetes, cardiogenic shock, and failed PCI but not valve type or success of coronary engagement.ConclusionsCA or PCI after TAVR in acute settings is usually successful, but selective coronary engagement may be more challenging in the presence of long SFPs. Among patients requiring PCI, prior diabetes, cardiogenic shock, and failed PCI were predictors of early mortality.  相似文献   

5.
ObjectivesThe aim of this study was to evaluate the feasibility of coronary access and aortic valve reintervention in low-risk patients undergoing transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter heart valve (THV).BackgroundYounger, low-risk TAVR patients are more likely than older, higher risk patients to require coronary angiography, percutaneous coronary intervention, or aortic valve reintervention, but their THVs may impede coronary access and cause coronary obstruction during TAVR-in-TAVR.MethodsThe LRT (Low Risk TAVR) trial (NCT02628899) enrolled 200 subjects with symptomatic severe aortic stenosis to undergo TAVR using commercially available THVs. Subjects who received balloon-expandable THVs and who had 30-day cardiac computed tomographic scans were included in this study. In a subgroup, the feasibility of intentional THV crimping on the delivery catheter to pre-determine commissural alignment was tested.ResultsIn the LRT trial, 168 subjects received balloon-expandable THVs and had 30-day cardiac computed tomographic scans, of which 137 were of adequate image quality for analysis. The most challenging anatomy for coronary access (THV frame above and commissural suture post in front of a coronary ostium) was observed in 9% to 13% of subjects. Intentional THV crimping did not appear to meaningfully affect commissural alignment. The THV frame extended above the sinotubular junction in 21% of subjects, and in 13%, the distance between the THV and the sinotubular junction was <2 mm, signifying that TAVR-in-TAVR may not be feasible without causing coronary obstruction.ConclusionsTAVR may present challenges to future coronary access and aortic valve reintervention in a substantial number of low-risk patients.  相似文献   

6.
ObjectivesThe authors sought to estimate possible interference of the Medtronic Evolut R/Pro transcatheter heart valve (THV) frame with coronary access using multislice computed tomography (MSCT) data.BackgroundLower-risk patients undergoing transcatheter aortic valve replacement (TAVR) endure a high cumulative risk of coronary events, but coronary access can be challenging.MethodsIn 101 patients who received an Evolut R/Pro THV, post-TAVR MSCT (performed at a median of 30 days after TAVR) was used to assess possible interference of the elements of the THV frame with coronary access.ResultsThe closest cell of the THV frame vertically aligned with the coronary ostium was located opposite the ostium in 58% and 63%, below the ostium in 22% and 30%, or above the ostium in 20% and 7% of left and right coronary arteries, respectively. The free sinus of Valsalva space between the THV frame and the coronary ostium was 0.45 ± 0.17 cm and 0.44 ± 0.17 cm for the left and right coronary arteries, respectively, and showed a stepwise decrease with decreasing THV size (p < 0.001). Bioprosthetic valve commissures were antianatomic (i.e., not aligned with native commissures) in 45 patients (47%), and the commissural post was overlapping a coronary ostium in 15 patients (16%). Two patients (2.0%) had a possible interference of the paravalvular sealing skirt with coronary access.ConclusionsUsing post-TAVR MSCT data, the main mechanism of potential interference of Evolut R/Pro frame with coronary access was an antianatomic commissural post overlapping the coronary ostium.  相似文献   

7.
ObjectivesThe aim of this study was to investigate the safety and efficacy of coronary protection by preventive coronary wiring and stenting across the coronary ostia in patients at high risk for coronary obstruction after transcatheter aortic valve replacement (TAVR).BackgroundCoronary obstruction following TAVR is a life-threatening complication with high procedural and short-term mortality.MethodsData were collected retrospectively from a multicenter international registry between April 2011 and February 2019.ResultsAmong 236 patients undergoing coronary protection with preventive coronary wiring, 143 had eventually stents implanted across the coronary ostia after valve deployment. At 3-year follow-up, rates of cardiac death were 7.8% in patients receiving stents and 15.7% in those not receiving stents (adjusted hazard ratio: 0.42; 95% confidence interval: 0.14 to 1.28; p = 0.13). There were 2 definite stent thromboses (0.9%) in patients receiving stents, both occurring after TAVR in “valve-in-valve” procedures. In patients not receiving stents, there were 4 delayed coronary occlusions (DCOs) (4.3%), occurring from 5 min to 6 h after wire removal. Three cases occurred in valve-in-valve procedures and 1 in a native aortic valve procedure. Distance between the virtual transcatheter valve and the protected coronary ostia <4 mm was present in 75.0% of patients with DCO compared with 30.4% of patients without DCO (p = 0.19).ConclusionsIn patients undergoing TAVR at high risk for coronary obstruction, preventive stent implantation across the coronary ostia is associated with good mid-term survival rates and low rates of stent thrombosis. Patients undergoing coronary protection with wire only have a considerable risk for DCO.  相似文献   

8.
ObjectivesThe aim of this study was to evaluate the impact of initial deployment orientation of SAPIEN 3, Evolut, and ACURATE-neo transcatheter heart valves on their final orientation and neocommissural overlap with coronary arteries.BackgroundCoronary artery access and redo transcatheter aortic valve replacement (TAVR) following initial TAVR may be influenced by transcatheter heart valve orientation. In this study the impact of transcatheter heart valve deployment orientation on commissural alignment was evaluated.MethodsPre-TAVR computed tomography and procedural fluoroscopy were analyzed in 828 patients who underwent TAVR (483 SAPIEN 3, 245 Evolut, and 100 ACURATE-neo valves) from March 2016 to September 2019 at 5 centers. Coplanar fluoroscopic views were coregistered to pre-TAVR computed tomography to determine commissural alignment. Severe overlap between neocommissural posts and coronary arteries was defined as 0° to 20° apart. The SAPIEN 3 had 1 commissural post crimped at 3, 6, 9, and 12 o’clock. The Evolut “Hat” marker and ACURATE-neo commissural post at deployment were classified as center back (CB), inner curve (IC), outer curve (OC), or center front (CF) and matched with final orientation.ResultsInitial SAPIEN 3 crimped orientation had no impact on commissural alignment. Evolut “Hat” at OC or CF at initial deployment had less severe overlap than IC or CB (p < 0.001) against the left main (15.7% vs. 66.0%) and right coronary (7.1% vs. 51.1%) arteries. Tracking Evolut “Hat” at OC of the descending aorta (n = 107) improved OC at deployment from 70.2% to 91.6% (p = 0.002) and reduced coronary artery overlap by 36% to 60% (p < 0.05). ACURATE-neo commissural post at CB or IC during deployment had less coronary artery overlap compared to CF or OC (p < 0.001), with intentional alignment successful in 5 of 7 cases.ConclusionsThis is the first systematic evaluation of commissural alignment in TAVR. More than 30% to 50% of cases had overlap with 1 or both coronary arteries. Initial SAPIEN 3 orientation had no impact on alignment, but specific initial orientations of Evolut and ACURATE improved alignment. Optimizing valve alignment to avoid coronary artery overlap will be important in coronary artery access and redo TAVR.  相似文献   

9.
ObjectivesThis study sought to evaluate the incidence and causes of percutaneous coronary intervention (PCI) at different time periods following transcatheter aortic valve replacement (TAVR).BackgroundCoronary artery disease (CAD) and aortic stenosis frequently coexist, but the optimal management of CAD following TAVR remains incompletely elucidated.MethodsPatients undergoing unplanned PCI after TAVR were retrospectively included in an international multicenter registry.ResultsBetween July 2008 and March 2019, a total of 133 patients (0.9%; from a total cohort of 15,325) underwent unplanned PCI after TAVR (36.1% after balloon-expandable bioprosthesis, 63.9% after self-expandable bioprosthesis). The median time to PCI was 191 days (interquartile range: 59 to 480 days). The daily incidence of PCI was highest during the first week after TAVR and then declined over time. Overall, the majority of patients underwent PCI due to an acute coronary syndrome, and specifically 32.3% had non–ST-segment elevation myocardial infarction, 15.4% had unstable angina, 9.8% had ST-segment elevation myocardial infarction, and 2.2% had cardiac arrest. However, chronic coronary syndromes are the main indication beyond 2 years. PCI success was reported in almost all cases (96.6%), with no significant differences between patients treated with balloon-expandable and self-expandable bioprostheses (100% vs. 94.9%; p = 0.150).ConclusionsUnplanned PCI after TAVR is rare, with an incidence declining over time after TAVR. The main indication to PCI is acute coronary syndrome in the first 2 years after TAVR, and thereafter chronic coronary syndromes become prevalent. Unplanned PCIs are frequently successfully performed after TAVR, with no apparent differences between balloon-expandable and self-expandable bioprostheses. (Revascularization After Transcatheter Aortic Valve Implantation [REVIVAL]; NCT03283501)  相似文献   

10.
ObjectivesThe aim of this study was to describe baseline characteristics, and periprocedural and mid-term outcomes of patients undergoing transcatheter mitral valve interventions post-transcatheter aortic valve replacement (TAVR) and examine their clinical benefit.BackgroundThe optimal management of residual mitral regurgitation (MR) post-TAVR is challenging.MethodsThis was an international registry of 23 TAVR centers.ResultsIn total, 106 of 24,178 patients (0.43%) underwent mitral interventions post-TAVR (100 staged, 6 concomitant), most commonly percutaneous edge-to-edge mitral valve repair (PMVR). The median interval post-TAVR was 164 days. Mean age was 79.5 ± 7.2 years, MR was >moderate in 97.2%, technical success was 99.1%, and 30-day device success rate was 88.7%. There were 18 periprocedural complications (16.9%) including 4 deaths. During a median follow-up of 464 days, the cumulative risk for 3-year mortality was 29.0%. MR grade and New York Heart Association (NYHA) functional class improved dramatically; at 1 year, MR was moderate or less in 90.9% of patients (mild or less in 69.1%), and 85.9% of patients were in NYHA functional class I/II. Staged PMVR was associated with lower mortality versus medical treatment (57.5% vs. 30.8%) in a propensity-matched cohort (n = 156), but this was not statistically significant (hazard ratio: 1.75; p = 0.05).ConclusionsFor patients who continue to have significant MR, remain symptomatic post-TAVR, and are anatomically suitable for transcatheter interventions, these interventions are feasible, safe, and associated with significant improvement in MR grade and NYHA functional class. These results apply mainly to PMVR. A staged PMVR strategy was associated with markedly lower mortality, but this was not statistically significant. (Transcatheter Treatment for Combined Aortic and Mitral Valve Disease. The Aortic+Mitral TRAnsCatheter Valve Registry [AMTRAC]; NCT04031274)  相似文献   

11.
ObjectivesThe aim of this study was to assess acute regurgitation following transcatheter aortic valve replacement, comparing different implanted transcatheter heart valves.BackgroundRegurgitation following transcatheter aortic valve replacement influences all-cause mortality. Thus far, no quantitative comparison of regurgitation among multiple commercially available transcatheter heart valves has been performed.MethodsAortograms from a multicenter cohort of consecutive 3,976 transcatheter aortic valve replacements were evaluated in this pooled analysis. A total of 2,258 (58.3%) were considered analyzable by an independent academic core laboratory using video densitometry. Results of quantitative regurgitation are shown as percentages. The valves evaluated were the ACURATE (n = 115), Centera (n = 11), CoreValve (n = 532), Direct Flow Medical (n = 21), Evolut PRO (n = 95), Evolut R (n = 295), Inovare (n = 4), Lotus (n = 546), Lotus Edge (n = 3), SAPIEN XT (n = 239), and SAPIEN 3 (n = 397). For the main analysis, only valves with more than 50 procedures (7 types) were used.ResultsThe Lotus valve had the lowest mean regurgitation (3.5 ± 4.4%), followed by Evolut PRO (7.4 ± 6.5%), SAPIEN 3 (7.6 ± 7.1%), Evolut R (7.9 ± 7.4%), SAPIEN XT (8.8 ± 7.5%), ACURATE (9.6 ± 9.2%) and CoreValve (13.7 ± 10.7%) (analysis of variance p < 0.001). The only valves that statistically differed from all their counterparts were Lotus (as the lowest regurgitation) and CoreValve (the highest). The proportion of patients presenting with moderate or severe regurgitation followed the same ranking order: Lotus (2.2%), Evolut PRO (5.3%), SAPIEN 3 (8.3%), Evolut R (8.8%), SAPIEN XT (10.9%), ACURATE (11.3%), and CoreValve (30.1%) (chi-square p < 0.001).ConclusionsIn this pooled analysis stemming from daily clinical practice, the Lotus valve was shown to have the best immediate sealing. This analysis reflects the objective evaluation of regurgitation by an academic core laboratory (nonsponsored) in a real-world cohort of patients using a quantitative technique.  相似文献   

12.
BackgroundTranscatheter aortic valve replacement (TAVR)–related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies.ObjectivesThis study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis.MethodsPreprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort.ResultsSixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right.ConclusionsA novel computed tomography–based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.  相似文献   

13.
ObjectivesThe aim of this study was to define predictors of prosthesis-patient mismatch (PPM) and its impact on mortality after transcatheter aortic valve replacement (TAVR) with self-expandable valves (SEVs) in patients with small annuli.BackgroundTAVR seems to reduce the risk for PPM compared with surgical aortic valve replacement, especially in patients with small aortic annuli. Nevertheless, predictors and impact of PPM in this population have not been clarified yet.MethodsPredictors of PPM and all-cause mortality were investigated using multivariable logistic regression analysis from the cohort of the TAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter SEVs: 445 patients with (n = 129) and without (n = 316) PPM were enrolled.ResultsIntra-annular valves conferred increased risk for PPM (odds ratio [OR]: 2.36; 95% confidence interval [CI]: 1.16 to 4.81), while post-dilation (OR: 0.46; 95% CI: 0.25–0.84) and valve oversizing (OR: 0.53; 95% CI: 0.28–1.00) seemed to protect against PPM occurrence. At a median follow-up of 354 days, patients with severe PPM, but not those with moderate PPM, had a higher all-cause mortality rate compared with those without PPM (log-rank p = 0.008). Multivariable Cox regression confirmed severe PPM as an independent predictor of all-cause mortality (hazard ratio: 4.27; 95% CI: 1.34 to 13.6).ConclusionsAmong patients with aortic stenosis and small aortic annuli undergoing transcatheter SEV implantation, use of intra-annular valves yielded higher risk for PPM; conversely, post-dilation and valve oversizing protected against PPM occurrence. Severe PPM was independently associated with all-cause mortality.  相似文献   

14.
ObjectivesThe authors sought to determine whether coronary artery tortuosity negatively affects clinical outcomes after stent implantation.BackgroundCoronary artery tortuosity is a common angiographic finding and has been associated with increased rates of early and late major adverse events after balloon angioplasty.MethodsIndividual patient data from 6 prospective, randomized stent trials were pooled. Outcomes at 30 days and 5 years following percutaneous coronary intervention of a single coronary lesion were analyzed according to the presence or absence of moderate/severe vessel tortuosity, as determined by an angiographic core laboratory. The primary endpoint was target vessel failure (TVF) (composite of cardiac death, target vessel–related myocardial infarction [TV-MI], or ischemia-driven target vessel revascularization [ID-TVR]).ResultsA total of 6,951 patients were included, 729 of whom (10.5%) underwent percutaneous coronary intervention in vessels with moderate/severe tortuosity. At 30 days, TVF was more frequent in patients with versus without moderate/severe tortuosity (3.8% vs. 2.4%; hazard ratio [HR]: 1.64; 95% confidence interval [CI]: 1.09 to 2.46; p = 0.02), a difference driven by a higher rate of TV-MI. At 5 years, TVF remained increased in patients with moderate/severe tortuosity (p = 0.003), driven by higher rates of TV-MI (p = 0.003) and ID-TVR (p = 0.01). Definite stent thrombosis was also greater in patients with versus without moderate/severe tortuosity (1.9% vs. 1.0%; HR: 1.86; 95% CI: 1.02 to 3.39; p = 0.04). After adjustment for baseline covariates, moderate/severe vessel tortuosity was independently associated with TV-MI and ID-TVR at 5 years (p = 0.04 for both).ConclusionsStent implantation in vessels with moderate/severe coronary artery tortuosity is associated with increased rates of TVF due to greater rates of TV-MI and ID-TVR.  相似文献   

15.
ObjectivesThe aim of this study was to determine the safety and efficacy of chimney stenting, a bailout technique to treat coronary artery occlusion (CAO).BackgroundCAO during transcatheter aortic valve replacement (TAVR) is a rare but often fatal complication.MethodsIn the international Chimney Registry, patient and procedural characteristics and data on outcomes are retrospectively collected from patients who underwent chimney stenting during TAVR.ResultsTo date, 16 centers have contributed 60 cases among 12,800 TAVR procedures (0.5%). Chimney stenting was performed for 2 reasons: 1) due to the development of an established CAO (n = 25 [41.6%]); or 2) due to an impending CAO (n = 35 [58.3%]). The majority of cases (92.9%) had 1 or more classical risk factors for CAO. Upfront coronary protection was performed in 44 patients (73.3%). Procedural and in-hospital mortality occurred in 1 and 2 patients, respectively. Myocardial infarction (52.0% vs. 0.0%; p < 0.01), cardiogenic shock (52.0% vs. 2.9%; p < 0.01), and resuscitation (44.0% vs. 2.9%; p < 0.01) all occurred more frequently in patients with established CAO compared with those with impending CAO. The absence of upfront coronary protection was the sole independent risk factor for the combined endpoint of death, cardiogenic shock, or myocardial infarction. During a median follow-up time of 612 days (interquartile range: 405 to 842 days), 2 cases of stent failure were reported (1 in-stent restenosis, 1 possible late stent thrombosis) after 157 and 374 days.ConclusionsChimney stenting appears to be an acceptable bailout technique for CAO, with higher event rates among those with established CAO and among those without upfront coronary protection.  相似文献   

16.
ObjectivesThe aim of this study was to assess coronary accessibility after transcatheter aortic valve replacement (TAVR)–in–TAVR using multidetector computed tomography.BackgroundExpanding TAVR to patients with longer life expectancy may involve more frequent bioprosthetic valve failure and need for redo TAVR. Coronary access after TAVR-in-TAVR may be challenging, particularly as the leaflets from the initial transcatheter heart valve (THV) will form a neo-skirt following TAVR-in-TAVR.MethodsIn 45 patients treated with different combinations of CoreValve and Evolut (CV/EV) THVs with supra-annular leaflet position and SAPIEN THVs with intra-annular leaflet position, post-TAVR-in-TAVR multidetector computed tomographic scans were analyzed to examine coronary accessibility.ResultsAfter TAVR-in-TAVR, the coronary arteries originated below the top of the neo-skirt in 90% of CV/EV-first cases compared with 67% of SAPIEN-first cases (p = 0.009). For these coronary arteries originating below the top of the neo-skirt, the distance between the THV and the aortic wall was <3 mm in 56% and 25% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.035). Coronary access may be further complicated by THV-THV stent frame strut misalignment in 53% of CV/EV-in-CV/EV cases. The risk for technically impossible coronary access was 27% and 10% in CV/EV-first and SAPIEN-first cases, respectively (p = 0.121). Absence of THV interference with coronary accessibility can be expected in 8% and 33% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.005).ConclusionsCoronary access after TAVR-in-TAVR may be challenging in a significant proportion of patients. THVs with intra-annular leaflet position or low commissural height and large open cells may be preferable in terms of coronary access after TAVR-in-TAVR.  相似文献   

17.
ObjectivesThe aim of this study was to evaluate the risk of coronary obstruction due to sinus sequestration in redo transcatheter aortic valve replacement (TAVR) using post-TAVR computed tomography (CT).BackgroundLittle information is available regarding the risk of coronary obstruction due to sinus sequestration in redo TAVR inside a previously implanted TAV.MethodsPost-TAVR CT of 66 patients who received an Evolut R or Evolut PRO and 345 patients who received a SAPIEN 3 were analyzed. Redo TAVR was considered at risk of coronary obstruction due to sinus sequestration if: 1) the prior TAV commissure level was above sinotubular junction (STJ); and 2) the distance between TAV and STJ was <2.0 mm in each coronary sinus.ResultsIn total, 45.5% in the Evolut R/Evolut PRO group and 2.0% in the SAPIEN 3 group had CT-identified risk of sinus sequestration at 1 or both coronary arteries (p < 0.001). CT-identified risk of sinus sequestration was observed in 39.4% for the left coronary artery and 24.2% for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 2.0% for the left coronary artery and 0.6% for the right coronary artery in the SAPIEN 3 group. In a coronary-level analysis, overlaps between the first TAV commissural posts and coronary ostium were observed in 45.2% in the Evolut R/Evolut PRO group and 11.1% in in the SAPIEN 3 group among coronary arteries at CT-identified risk of sinus sequestration.ConclusionsThe risk of sinus sequestration in redo TAVR should be carefully screened by CT, especially in patients with low STJ height. TAV with low commissure height that was designed to achieve commissure-to-commissure alignment with the native aortic valves may be preferable to avoid the risk of coronary obstruction due to sinus sequestration and allow for a preventive leaflet laceration procedure in future redo TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

18.
BackgroundThe optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined.ObjectivesThis study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD.MethodsPatients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site–related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score).ResultsAmong the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site–related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049).ConclusionsAmong patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.  相似文献   

19.
BackgroundHigh systolic blood pressure (SBP) increases cardiac afterload, whereas low diastolic blood pressure (DBP) may lead to impaired coronary perfusion. Thus, wide pulse pressure (high systolic, low diastolic [HSLD]) may contribute to myocardial ischemia and also be a predictor of adverse cardiovascular events.ObjectivesThe purpose of this study was to determine the relationship between pre-procedural blood pressure and long-term outcome following percutaneous coronary intervention (PCI).MethodsThe study included 10,876 consecutive patients between August 2009 and December 2016 from the Melbourne Interventional Group registry undergoing PCI with pre-procedural blood pressure recorded. Patients with ST-segment elevation myocardial infarction, cardiogenic shock, and out-of-hospital cardiac arrest were excluded. Patients were divided into 4 groups according to SBP (high ≥120 mm Hg, low <120 mm Hg) and DBP (high >70 mm Hg, low ≤70 mm Hg).ResultsMean pulse pressure was 60 ± 21 mm Hg. Patients with HSLD were older and more frequently women, with higher rates of hypercholesterolemia, renal impairment, diabetes, and multivessel and left main disease (all p ≤ 0.0001). There was no difference in 30-day major adverse cardiac events, but at 12 months the HSLD group had a greater incidence of myocardial infarction (p = 0.018) and stroke (p = 0.013). Long-term mortality was highest for HSLD (7.9%) and lowest for low systolic, high diastolic (narrow pulse pressure) at 2.1% (p = 0.0002). Cox regression analysis demonstrated significantly lower long-term mortality in the low systolic, high diastolic cohort (hazard ratio: 0.50; 99% confidence interval: 0.25 to 0.98; p = 0.04).ConclusionsPulse pressure at the time of index PCI is associated with long-term outcomes following PCI. A wide pulse pressure may serve as a surrogate marker for risk following PCI and represents a potential target for future therapies.  相似文献   

20.
BackgroundAortic stenosis and coronary artery disease (CAD) frequently coincide. However, the management of coexisting CAD in patients undergoing transcatheter aortic valve replacement (TAVR) remains controversial.ObjectivesThis study sought to determine whether the presence of CAD, its complexity, and angiography-guided percutaneous coronary intervention (PCI) are associated with outcomes after TAVR.MethodsAll patients undergoing TAVR at a tertiary referral center between 2008 and 2020 were included in a prospective observational study. Baseline SYNTAX (Synergy between PCI with Taxus and Cardiac Surgery) score (SS) and, whenever applicable, a residual SS after PCI were calculated. A multivariate analysis was performed to determine the effect of CAD, stratified according to complexity, and PCI on 5-year outcomes.ResultsIn 604 patients, the presence of CAD and its complexity were significantly associated with worse 5-year survival (SS 0: 67.9% vs SS 1-22: 56.1% vs SS >22: 53.0%; log-rank P = 0.027) and increased cardiovascular mortality (SS 0: 15.1% vs SS 1-22: 24.0% vs SS >22: 27.8%; log-rank P = 0.024) after TAVR. Having noncomplex CAD (SS 1-22) was an independent predictor for increased all-cause mortality (HR: 1.43; P = 0.046), while complex CAD (SS >22) increased cardiovascular mortality significantly (HR: 1.84; P = 0.041). Angiography-guided PCI or completeness of revascularization was not associated with different outcomes.ConclusionsThe presence of CAD and its anatomical complexity in patients undergoing TAVR are associated with significantly worse 5-year outcomes. However, angiography-guided PCI did not improve outcomes, highlighting the need for further research into physiology-guided PCI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号