首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Abdominal aortic aneurysm (AAA) repair in the presence of a kidney transplant can be extremely challenging, as it carries significant risks of renal ischemia. Endovascular repair is an attractive option, as it can be performed with little or no impairment of renal arterial flow. We describe the endovascular management of a recurrent AAA in a patient with a functioning renal transplant using a custom-made aorto-uni-iliac device. We discuss the planning and the potential problems of the technique.  相似文献   

2.
Reintervention following endovascular aneurysm repair (EVAR) is required in up to 10% of patients at 30 days and is associated with a demonstrable risk of increased mortality. Completion angiography cannot detect all graft-related anomalies and computed tomographic angiography is therefore mandatory to ensure clinical success. Intraoperative angiographic computed tomography (DynaCT; Siemens, Germany) utilizes cone beam reconstruction software and flat-panel detectors to generate CT-like images from rotational angiographic acquisitions. We report the intraoperative use of this novel technology in detecting and immediately treating a proximal anterior type Ia endoleak, following an endovascular abdominal aortic repair, which was not seen on completion angiography. Immediate evaluation of cross-sectional imaging following endograft deployment may allow for on-table correction of clinically significant stent-related complications. This should both improve technical success and minimize the need for early secondary intervention following EVAR.  相似文献   

3.
Purpose To evaluate the volumetric changes in abdominal aortic aneurysms (AAA) after endovascular AAA repair (EVAR) in 24 months of follow-up.Methods We evaluated the volume modifications in 63 consecutive patients after EVAR. All patients underwent strict duplex ultrasound and computed tomography angiography (CTA) follow-up; when complications were suspected, digital subtraction angiography was also performed. CTA datasets at 1, 6, 12, and 24 months were post-processed through semiautomatic segmentation, to isolate the aneurysmal sac and calculate its volume. Maximum transverse diameters (Dmax) were also obtained in the true axial plane, Presence and type of endoleak (EL) were recorded. A statistical analysis was performed to assess the degree of volume change, correlation with diameter modifications, and significance of the volume increase with respect to ELs.Results Mean reconstruction time was 7 min. Mean volume reduction rates were 6.5%, 8%, and 9.6% at 6, 12, and 24 months follow-up, respectively. Mean Dmax reduction rates were 4.2%, 6.7%, and 12%; correlation with volumes was poor (r = 0.73–0.81). ELs were found in 19 patients and were more frequent (p = 0.04) in patients with higher preprocedural Dmax, The accuracies of volume changes in predicting ELs ranged between 74.6% and 84.1% and were higher than those of Dmax modifications. The strongest independent predictor of EL was a volume change at 6 months ≤0.3% (p = 0.005), although 6 of 19 (32%) patients with EL showed no significant AAA enlargement, whereas in 6 of 44 (14%) patients without EL the aneurysm enlarged.Conclusion The lack of volume decrease in the aneurysm of at least 0.3% at 6 months follow-up indicates the need for closer surveillance, and has a higher predictive accuracy for an endoleak than Dmax.  相似文献   

4.

Objective

The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair.

Materials and Methods

Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months)

Results

Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications.

Conclusion

The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.  相似文献   

5.
As an alternative to open aneurysm repair, emergency endovascular aortic repair (EVAR) has emerged as a promising technique for ruptured abdominal aortic aneurysm (rAAA) within the last decade. The aim of this retrospective study is to present early and late outcomes of patients treated with EVAR for rAAA. Twenty-two patients (5 women, 17 men; mean age, 74 years) underwent EVAR for rAAA between November 2000 and April 2006. Diagnostic multislice computed tomography angiography was performed prior to stent-graft repair to evaluate anatomical characteristics and for follow-up examinations. Periprocedural patient characteristics and technical settings were evaluated. Mortality rates, hospital stay, and early and late complications, within a mean follow-up time of 744 ± 480 days, were also assessed. Eight of 22 patients were hemodynamically unstable at admission. Stent-graft insertion was successful in all patients. The total early complication rate was 54%, resulting in a 30-day mortality rate of 23%. The median intensive care unit stay was 2 days (range, 2–48 days), and the median hospital stay was 16 days (range, 9–210 days). During the follow-up period, three patients suffered from stent-graft-related complications. The overall mortality rate in our study group was 36%. EVAR is an acceptable, minimally invasive treatment option in patients with acute rAAA, independent of the patient’s general condition. Short- and long-term outcomes are definitely comparable to those with open surgical repair procedures.  相似文献   

6.
We report the case of a 69-year-old man with a late type 1b endoleak due to proximal migration of both iliac limbs 5 years after endovascular repair of an abdominal aortic aneurysm. The endovascular method used to correct bilaterally this condition is described. Final angiographic control shows patency of the stent-graft without signs of endoleak.  相似文献   

7.
Purpose The principal anatomic contraindication to endovascular aneurysm repair (EVR) is an unfavorable proximal aortic neck. With increasing experience, a greater proportion of patients with unfavorable neck anatomy are being offered EVR. This study aimed to evaluate outcomes in patients with challenging proximal aortic neck anatomy. Methods Prospectively collected data from 147 consecutive patients who underwent EVR between December 1997 and April 2005 were supplemented with a retrospective review of medical records and radiological images. Unfavorable anatomic features were defined as neck diameter >28 mm, angulation >60°, circumferential thrombus >50%, and length <10 mm. Eighty-seven patients with 0 adverse features (good necks) were compared with 60 patients with one or more adverse features (hostile necks). Results Comparing the good neck with the hostile neck group, there were no significant differences in the incidence of primary technical success (p = 0.15), intraoperative adjunctive procedures (p = 0.22), early proximal type I endoleak (<30 days) (p = 1.0), late proximal type I endoleak (>30 days) (p = 0.57), distal type I endoleak (p = 0.40), type III endoleak (p = 0.51), secondary interventions (p = 1.0), aneurysm sac expansion (p = 0.44), or 30 day mortality (p = 0.70). The good neck group had a significantly increased incidence of type II endoleak (p = 0.023). By multivariate analysis, the incidence of intraoperative adjunctive procedures was significantly increased in the presence of severe angulation (p = 0.041, OR 3.08, 95% CI 1.05–9.04). Conclusion Patients with severely hostile proximal aortic neck anatomy may be treated with EVR, although severely angulated necks require additional intraoperative procedures. Early outcomes are encouraging and suggest that indications for EVR may be expanded to include patients with hostile neck anatomy.  相似文献   

8.
Patients with functioning renal transplant who develop abdominal aortic aneurysm can safely be treated with endovascular repair. Endovascular repair of aneurysm avoids renal ischemia associated with cross-clamping of aorta. Correspondence to: N. Arya, Specialist Registrar, Level 5, Regional Vascular and Endovascular Unit, Belfast City Hospital, Lisburn Road, Belfast, Northern Ireland, United Kingdom, BT9 7AB. Tel: 0044-2890263632; Fax: 0044-2890263951; Email: nityaarya@aol.com.  相似文献   

9.
To assess the accuracy and efficacy of intravascular ultrasound guidance obtained by an intracardiac ultrasound probe during complex aortic endografting. Between November 1999 and July 2002, 19 patients (5 female, 14 male; mean age 73.5 ± 2.1 years) underwent endovascular repair of thoracic (n = 10), complex abdominal (n = 6) and concomitant thoraco-abdominal (n = 3) aortic aneurysm. The most suitable size and configuration of the stent-graft were chosen on the basis of preoperative computed tomographic angiography (CTA) or magnetic resonance angiography (MRA). Intraoperative intravascular ultrasound imaging was obtained using a 9 Fr, 9 MHz intracardiac echocardiography (ICE) probe, 110 cm in length, inserted through a 10 Fr precurved long sheath. The endografts were deployed as planned by CTA or MRA. Before stent-graft deployment, the ICE probe allowed us to view the posterior aortic arch and descending thoraco-abdominal aorta without position-related artifacts, and to identify both sites of stent-graft positioning. After stent-graft deployment, the ICE probe allowed us to detect the need for additional modular components to internally reline the aorta in 11 patients, and to discover 2 incomplete graft expansions subsequently treated with adjunctive balloon angioplasty. In 1 patient, the ICE probe supported the decision that the patient was ineligible for the endovascular exclusion procedure. The ICE probe provides accurate information on the anatomy of the posterior aortic arch and thoracic and abdominal aortic aneurysms and a rapid identification of attachment sites and stent-graft pathology, allowing refinement and improvement of the endovascular strategy.  相似文献   

10.
Aneurysm sac expansion following endovascular abdominal aortic aneurysm repair (EVAR) is typically associated with endoleaks that can be readily diagnosed on computed tomographic angiography (CTA), ultrasound, or catheter-directed arteriography. Sac hygromas are a cause of sac expansion without apparent endoleak and are presumed to be a result of ultrafiltration of serum manifested by accumulation of fibrinous, gelatinous material within the aneurysm sac following EVAR. Although there are no reported associated ruptures, sac expansion is nevertheless disconcerting and intervention is presumably indicated. We report a case of an expanding aneurysm after EVAR secondary to sac hygroma that was successfully treated with relining of the existing, original endograft.  相似文献   

11.
We describe a novel approach in treating a persistent type II endoleak related to the inferior mesenteric artery (IMA) and the lower lumbar arteries. The endoleak failed to thrombose following percutaneous IMA coil embolization. We proceeded to one-stage laparoscopic IMA division and intra-sac thrombin injection under direct laparoscopic vision and fluroscopy. A CT scan at 1 and 7 months post-intervention showed no evidence of endoleak and the growth of the aneurysm was arrested. This combined laparoscopic and percutaneous approach may be a useful treatment option in the management of persistent complex type II endoleak. Its durability, however has yet to be defined.  相似文献   

12.
This report describes the use of thrombin to treat a type II endoleak which was causing continued abdominal aortic aneurysm expansion in a patient who had undergone endovascular repair. A small quantity of thrombin was injected into the leak by a percutaneous approach directly into the aneurysm sac using color doppler ultrasound. The procedure was successful and required only a few minutes to perform. We believe this procedure is an alternative to some of the more complex and technically challenging means of treating this lesion.  相似文献   

13.
Purpose To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1–36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions Endovascular repair is a good option for emergency treatment of AAAs. The team’s experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment.  相似文献   

14.

Purpose

To assess differences in outcome in an early and later time period in patients with hostile neck anatomy who underwent endovascular aneurysm repair (EVAR).

Materials and Methods

This single-center, institutional review board-approved retrospective study assessed patients who underwent EVAR between 2004 and 2013, divided into 2 time periods: 2004–2008 and 2009–2013. One hundred twenty-five patients had at least 1 hostile neck parameter that met inclusion criteria: 61 of 216 (28%) patients in the early period and 64 of 144 (44%) patients in the late period. Patients in the late group were younger compared to patients in the early group (late group, 74.5 ± 8.8 years vs early group, 77.5 ± 7.5 years; P = .046). No significant differences were observed in hostile neck anatomic factors between the early and late periods.

Results

No statistical difference was observed in periprocedural factors or outcome measures, except for abdominal aortic aneurysm (AAA) sac regression in the late period compared to the early period (late period, 73.5% vs early period, 55.7%; P = .038). A statistically significant increase was observed in type 1a endoleaks in patients in the late group with suprarenal fixation compared to patients with infrarenal fixation (suprarenal, 27.0% vs infrarenal, 7.9%; P = .025) and in the overall time studied (suprarenal, 20.3% vs infrarenal, 7.6%; P = .045).

Conclusions

Except for AAA sac regression, no changes were observed in periprocedural factors and outcome measures over time in patients with hostile neck who underwent EVAR.  相似文献   

15.
The successful endovascular repair of a type III thoracoabdominal aortic aneurysm (TAAA) with the use of a tube endograft is reported. A 56-year-old male with a 6.4-cm type III TAAA, a 4.2-cm infrarenal abdominal aortic aneurysm, and chronic renal insufficiency presented with flank pain, nausea, acute anuria, and serum creatinine of 6.1 mg/dl. Acute occlusion of the left solitary renal artery was diagnosed and emergent recanalization with percutaneus transluminal angioplasty and stenting was performed successfully, with reversal of the serum creatinine level at 1.6 mg/dl. Further imaging studies for TAAA management revealed ostial occlusion of both the celiac artery (CA) and the superior mesenteric artery (SMA) but a hypertrophic inferior mesenteric artery (IMA) providing retrograde flow to the aforementioned vessels. This rare anatomic serendipity allowed us to repair the TAAA simply by using a two-component tube endograft without fenestrations (Zenith; William Cook, Bjaeverskov, Denmark) that covered the entire length of the aneurysm, including the CA and SMA origins, since a natural arterial bypass from the IMA to the CA and SMA already existed, affording protection from gastrointestinal ischemic complications. The patient had a fast and uneventful recovery and is currently doing well 6 months after the procedure. To our knowledge, this is the first report in the English literature of successful endovascular repair of a TAAA involving visceral arteries with the simple use of a tube endograft.  相似文献   

16.
A renal transplant recipient presented in the early post-transplantation period with rupture of an abdominal aortic aneurysm. The high mortality rate of the surgical repair of ruptured aneurysm in addition to the concern of preserving the renal graft prompted us to seek alternative approaches, such as repairing the aneurysm by means of endovascular techniques. The ruptured aneurysm was confirmed by performing computed tomography and digital angiography and thereafter was successfully repaired by endovascular stenting technique (Talent stent-graft), which seems to be a safe and effective method of preserving a renal graft.  相似文献   

17.
Coil embolization of the internal iliac artery (IIA) is used to extend the application of endovascular aneurysm repair (EVAR) in cases of challenging iliac anatomy. Pelvic ischemia is a complication of the technique, but reports vary as to the rate and severity. This study reports our experience with IIA embolization and compares the results to those of other published series. The vascular unit database of the Leicester Royal Infirmary was used to identify patients who had undergone IIA coil embolization prior to EVAR. Data were collected from hospital case notes and by telephone interviews. Thirty-eight patients were identified; 29 of these were contactable by telephone. A literature search was performed for other studies of IIA embolization and the results were pooled. In this series buttock claudication occurred in 55% (16 of 29 patients) overall: in 52% of unilateral embolizations (11 of 21) and 63% of bilateral embolizations (5 of 8). New erectile dysfunction occurred in 46% (6 of 13 patients) overall: in 38% of unilateral embolizations (3 of 8) and 60% of bilateral embolizations (3 of 5). The literature review identified 18 relevant studies. The results were pooled with our results, to give 634 patients in total. Buttock claudication occurred in 28% overall (178 of 634 patients): in 31% of unilateral embolizations (99 of 322) and 35% of bilateral embolizations (34 of 98) (p = 0.46, Fisher’s exact test). New erectile dysfunction occurred in 17% overall (27 of 159 patients): in 17% of unilateral embolizations (16 of 97) and 24% of bilateral embolizations (9 of 38) (p = 0.33). We conclude that buttock claudication and erectile dysfunction are frequent complications of IIA embolization and patients should be counseled accordingly.  相似文献   

18.
An aorto-caval fistula is a rare complication of a symptomatic or ruptured infrarenal aortic aneurysm having a frequency of 3–6%. Patients typically present with clinical signs of diffuse abdominal pain associated with increasing venous congestion and tachycardia, rapid cardiopulmonary decompensation with acute dyspnea, and an audible machinerylike bruit. Perioperative mortality is high, ranging from 20% to 60%. We report a case of an endovascular aortic repair in a patient with a symptomatic infrarenal aortic aneurysm and an aorto-caval fistula. Contrast-enhanced ultrasound seems to be a promising new diagnostic option for the diagnosis and preoperative treatment planning for patients with abdominal aortic aneurysms with rupture into the inferior vena cava. It is in addition to computed tomography angiography. It might allow a more rapid and noninvasive diagnosis, especially for patients in intensive care because of its bedside availability. Because the examination is dynamic, additional information about blood flow between the aorta and inferior cava vein can be evaluated.  相似文献   

19.
A patient with a ruptured iliac aneurysm was admitted to the Emergency Department in hypovolemic shock. He had previously undergone surgical treatment for an infrarenal abdominal aortic aneurysm, which was managed with a terminal-terminal Dacron tube graft. Subsequently, he developed two iliac aneurysms, which were treated endovascularly with two wall-grafts in the right and one wall-graft in the left iliac arteries. He suffered chronic renal failure and arterial hypertension. Contrast-enhanced computed tomography showed rupture of the right iliac aneurysm and dislocation of the two wall-grafts. He was treated in an emergency situation with the implantation of an iliac endograft that bridged the two wall-grafts, which resulted in hemostasis and stabilization of his condition. Five days later, in an elective surgical situation, he was treated with the implantation of an aorto-uni-iliac endograft combined with a femoral-femoral bypass. He was discharged 5 days later in good condition. At the 4 year follow-up visit, the endoprosthesis remained in place with no evidence of an endoleak. In conclusion, overlapping of endografts should be avoided, if possible. Strict surveillance of the endovascularly treated patient remains mandatory.  相似文献   

20.

Purpose

To report the midterm experience with chimney-endovascular aneurysm repair (Ch-EVAR) with the use of open self-expending stents for branch vessel preservation.

Materials and Methods

From July 2010 to May 2017, 67 patients underwent open Ch-EVAR because their proximal landing zones were adjacent to, or covered, the renal or mesenteric arteries (Zones 7–9), and they were not suitable for standard or fenestrated endovascular aneurysm repair. The proximal landing zone was relocated below the highest renal artery in 46 cases, the superior mesenteric artery in 17 cases, and the celiac artery in 4 cases, using 84 open chimneys (131 stents). A subgroup analysis was performed between an early (2010–2014) and a later (2015–2017) time period. Thirty-two patients were treated during the early period, and 35 were treated during the later period. In the later period, open chimneys were strengthened by a second self-expanding stent.

Results

The primary technical success rate was 89.6%; the early mortality rate was 9.0%; and the median follow-up duration was 13 months (range, 1–76 months). The estimated actuarial survival rate was 85.7% in year 1 and 79.2% in year 2, and the estimated patency rate of open chimneys reached 95.2% at 2 years. Aneurysm sac regression >5 mm and sac stability rates were 39.0% and 57.6%, respectively. Freedom from aneurysm-related reintervention was lower in the later period (log-rank P = .04), while type Ia endoleaks tended to be twice as likely.

Conclusions

Midterm results of open Ch-EVAR show high technical success with acceptable midterm patency and lack of endoleak in appropriately selected patients. The advantages over covered stents are lower-profile delivery systems and maintenance of branch vessel patency in early bifurcations and overlying visceral vessels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号