首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Multidetector CT (MDCT) is being increasingly used for patients with traumatic injuries in the emergency room. This is the first study to evaluate the diagnostic performance of MDCT for sternal fracture.

Patients and methods

For 87 patients who had motor vehicle accidents, we evaluated the diagnostic performance of MDCT for the sternal fractures. For 31 patients who underwent both MDCT and lateral radiography for the sternum, we compared the diagnostic performance of two examinations for the evaluation of sternal fracture.

Results

Thirty-two patients had sternal fractures and all the sternal fractures (sensitivity = 100%) were detected on MDCT, especially on the sagittal reconstruction images. However, the axial and coronal images detected 65% and 59% of all sternal fractures, respectively. For 31 patients who underwent both MDCT and lateral radiography for the sternum, MDCT showed superior diagnostic performance compared to that of radiography (accuracy = 97% and 77%, respectively, P = .02). For the one case that showed false positivity for sternal fracture on MDCT due to respiratory artifact, the lateral radiography enabled making the correct diagnosis.

Conclusion

Sternal fracture is frequently seen in patients who have blunt trauma injury secondary to motor vehicle accidents. MDCT, particularly sagittal images detect all of the sternal fractures, is superior to lateral radiography for diagnosis of sternal fracture. In the limited case that CT has severe motion artifact, additional radiography could help the diagnosis of sternal fracture.  相似文献   

2.

Purpose

The purpose of this study was to present the various vertebral bone signal and configuration patterns on T2WI MRI in osteoporotic benign fractures. The appearances were also assessed with thin slice MPR CT images.

Materials and methods

66 patients (43 women, 23 men; age range, 34–97 years; mean age, 76 years) with 100 vertebral compression fractures due to osteoporosis were included in our study. All cases are acute or subacute phase fractures which occurred within 1 month. Multiple fractures were observed in 29 patients, in 8 cases multiple concurrent fractures were proved by past radiograph or MRI. Three planes of T2WI (sagittal, coronal, axial) section images were correlated with the corresponding MDCT images.

Results

In our retrospective study, various signals and forms of vertebral body fractures were observed. The fracture zone (line) was classified 3 signal intensity patterns. (high; n = 24, low to intermediate; n = 16, low intensity; n = 38) on T2WI. The signal of the peri(para) fractured area were high (n = 6), intermediate to low (n = 41), low (n = 53)intensity. With CT correlative study, high, low to intermediate area were considered to be corresponded to the bone marrow edema, fibrous reparative tissue with/without the bony callus formation. The localization were as follows: sub-end plate band like lesion in 53, central in 16, anterior in 13, sub-endplate + anterior in 10, and complete (diffuse) in 8. In 10 cases, adjacent Schmorl's nodules were observed.

Conclusion

The various vertebral body signal patterns were observed in osteoporotic compressive fracture on T2WI. By MRI-CT correlations, high signal and low signal area on T2WI corresponded to the bone marrow edema, and the fibrous tissue or callus formation respectively.  相似文献   

3.

Purpose

To validate the diagnostic performance of quadruple phase low tube voltage liver CT through the comparison with Gd-EOB-DTPA enhanced liver MRI for the detection of HCC.

Materials and methods

Non-obese patients (38 men, eight women) with 68 HCCs underwent quadruple-phase CT at 16 MDCT (using low tube voltage, 80 kVp; moderately high tube current, 280 mAs) and Gd-EOB-DTPA-enhanced 3 T MRI. Three observers independently and randomly reviewed the CT and MR images on a tumor-by-tumor basis. The diagnostic accuracy of these techniques for detecting HCC was assessed using alternative free-response receiver operating characteristic analysis. Sensitivity and positive predictive values were evaluated. The mean effective doses for the low dose CT were also evaluated.

Results

The areas under the ROC curves were 0.963, 0.959, and 0.941 for low dose CT and 0.981, 0.982, and 0.976 for MRI. Differences in Az of the two techniques for each observer were not statistically significant (P > .05). Differences in sensitivity and positive predictive values between the two techniques for each observer were not also statistically significant: sensitivity (86.8%, 82.4%, 85.3% for CT and 95.6%, 94.1%, 91.2% for MRI) and positive predictive values (92.2%, 90.3%, 89.2% for CT and 92.9%, 92.8%, 92.5% for MRI). Six HCCs (8.8%) in five patients were observed only on hepatobiliary phase of MRI, and all were smaller than 1.5 cm. The mean effective dose for CT was approximately 10.2 mSv.

Conclusions

Quadruple-phase low-dose liver CT (80 kVp, 280 mAs) had relatively good diagnostic performance for detecting HCC in non-obese patients. Because no significant difference was observed between low-dose CT and MRI, the use of low-dose liver CT can be justified based on its reduced radiation effects.  相似文献   

4.

Purpose

The purpose of this study was to directly and prospectively compare the capability of dynamic O2-enhanced MRI and quantitatively assessed thin-section MDCT to assess smokers’ COPD in a large prospective cohort.

Materials and methods

The GOLD criteria for smokers were used to classify 187 smokers into four clinical stage groups as follows: smokers without COPD (n = 56) and with mild (n = 54), moderate (n = 52) and severe or very severe COPD (n = 24). All smokers underwent dynamic O2-enhanced MRI, MDCT and pulmonary function tests. Mean relative enhancement ratio and mean wash-in time on MRI and CT-based functional lung volume (CT-based FLV) as well as the ratio of airway wall area to total airway area on MDCT were computationally calculated. Then, all indexes were significantly correlated with functional parameters. To determine the efficacy of all indexes for clinical stage classification, the indexes for the four clinical groups were statistically compared by using Tukey's honestly significant difference multiple comparison test.

Results

All indexes had significant correlations with functional parameters (p < 0.0001). All indexes except CT-based FLV in all groups had significant differences each other (p < 0.05).

Conclusions

Dynamic O2-enhanced MRI for assessment of COPD in smokers is potentially as efficacious as quantitatively assessed thin-section MDCT.  相似文献   

5.

Purpose

The aim of this study was to investigate the clinical application value of right ventricle (RV) function measured by 64 multi-detector row CT (MDCT) in patients with chronic obstructive pulmonary disease (COPD) and cor pulmonale.

Materials and methods

Sixty-three consecutive patients with COPD and cor pulmonale were referred for electrocardiographically gated MDCT for evaluation of suspected or known coronary artery disease. Magnetic resonance imaging (MRI) for cardiac function analysis was performed on the same day. The MDCT and MRI examinations were successfully completed in 58 patients. Forty-six patients with COPD were divided into three groups according to the severity of disease by the pulmonary function test (PFT). Twelve patients diagnosed as cor pulmonale and 32 control subjects were also included. The RV function and myocardial mass (MM) were obtained by 64-MDCT and 1.5 T cardiac MRI in all of the groups. The results were compared among the groups using the Newman–Keuls method. Pearson's correlation was used to evaluate the relationship between the right ventricular ejection fraction (RVEF) and MM with the PFT results in COPD and cor pulmonale patients.

Results

The RVEF was significantly lower in patients with severe COPD and cor pulmonale than it was in those patients with mild or moderate COPD (P < 0.01). There were strong correlations between MDCT and MRI (r = 0.826 for RV MM, r = 0.982 and 0.969 for RV EDV and RV ESV, r = 0.899 for RVEF) and between MDCT results and forced expiratory volume in 1 s (r = 0.787 for RVEF, r = −0.774 for RV MM) in all patients.

Conclusion

MDCT can accurately quantify RV function and MM. The RVEF and RV MM measured by MDCT correlate well with the severity of disease as determined by PFT in patients with COPD and cor pulmonale. The assessment of right ventricular function is clinically important for evaluation of the severity of COPD, which may provide an objective basis for therapeutic strategy.  相似文献   

6.

Objectives

To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement.

Methods

Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7 ± 10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1–10).

Results

For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p < 0.01). The mean ALN was 37 ± 7% on CT angiograms using a B30s and 25 ± 9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347 ± 55 HU on CT angiograms using a B30s and 295 ± 46 HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p < 0.01).

Conclusions

16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.  相似文献   

7.

Purpose

To evaluate the diagnostic accuracy and indications of arthrography with multidetector computed tomography (arthro-MDCT) of the knee, in patients with absolute or relative contraindications to MRI and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard.

Materials and methods

After intra-articular injection of iodixanol and volumetric acquisition, 68 knees in patients of both sexes (30 females, 38 males, age range 32–60 years) were examined with a 16-detector-row CT scanner. The patients had arthralgia but no radiologically detected fractures. They could not be studied by MRI either because of absolute contraindications (subcutaneous electronic implants), surgical metal implants or claustrophobia. In 37 of 68 patients who had had previous knee surgery, the arthro-CT examination was preceded by an MRI on the same day.All examinations were interpreted by two experienced musculoskeletal radiologists.The findings were compared with arthroscopic findings carried out within 28 days of the CT study.

Results

In non-operated patients the comparison between arthro-MDCT and arthroscopy showed sensitivity and specificity ranging between 86% and 100%. In the 37 operated knees, arthro-MDCT had an accuracy of 95% compared with 53% of the MRI.Inter-observer agreement was almost perfect (K = 0.97) in the evaluation of all types lesions, both on MDCT and MRI.When arthro-MDCT was compared with MRI in post-operative patients by a McNemar test, a significant difference (p < 0.05) was found between these two techniques.

Conclusions

Arthro-MDCT of the knee is a safe technique that provides accurate diagnosis in identifying chondral, fibrocartilaginous and intra-articular ligamentous lesions, in patients that cannot be evaluated by MRI, and in patients after surgical.  相似文献   

8.

Objective

To evaluate agreement between contrast-enhanced ultrasound (CEUS), multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) for the assessment of typical and atypical enhancement patterns of small hepatocellular carcinoma (HCC); and to compare diagnostic sensitivity of 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines.

Materials and methods

Between January 2008 and December 2009, we included cirrhotic patients with newly diagnosed 10–20 mm HCC imaged at two contrast-enhanced imaging techniques among CEUS, MDCT, and MRI. Dynamic studies were reviewed by two radiologists to assess enhancement pattern. Percentage of cases with concordant findings and Cohen coefficient (k) were calculated. McNemar's test was used to compare sensitivity between 2005 and 2010 AASLD guidelines.

Results

There were 91 patients (69 M; 22 F; mean age, 68 years) with 96 HCCs, studied with a combination of CEUS and MDCT (n = 59), CEUS and MRI (n = 26), or MDCT and MRI (n = 11). Intermodality agreement for assessment of tumor enhancement pattern was 67% (k = 0.294, P = 0.001). Typical enhancement pattern was detected coincidentally at two imaging modalities in 50 (52%) HCCs. Sensitivity for the diagnosis of HCC increased significantly using the 2010 AASLD (81/96 (84%) vs. 50/96 (52%), P < 0.001).

Conclusions

Agreement between two imaging modalities for the detection of typical tumor enhancement pattern was reached in 52% of cases. The 2010 AASLD guidelines significantly increased the sensitivity for the diagnosis of HCC.  相似文献   

9.

Purpose

To compare the sensitivity and specificity of contrast-enhanced ultrasonography (CEUS) and 4-slice multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer (CRC).

Materials and methods

Candidates for this prospective study were 461 consecutive patients referred to the Department of Colorectal Surgery, Aarhus University Hospital with primary or local recurrence of CRC. The patients underwent liver ultrasonography (US), CEUS, MDCT and intraoperative ultrasonography (IOUS). Fine-needle biopsy was performed on all suspicious lesions. The examinations were interpreted blindly and the combination of US, CEUS, biphasic MDCT, IOUS, follow up and biopsy was the gold standard.

Results

Three hundred and sixty-five patients were included. All patients had undergone preoperative US, CEUS and MDCT and 65.5% had received IOUS. The gold standard found liver metastases in 54 patients (14.8%). Multidetector CT found significantly more metastases than CEUS in 15 (28%) of the patients (p = 0.02). In a patient-by-patient analysis MDCT had a non-significantly higher sensitivity in the detection of liver metastases compared to CEUS (0.89 versus 0.80, p = 0.06). The specificity of CEUS (0.98) was slightly better than that of MDCT (0.94) (p = 0.02).

Conclusion

Multidetector CT found significant more metastases than CEUS, and MDCT had in patient-by-patient analysis a non-significant better sensitivity (p = 0.06) in detecting liver metastases in patients with CRC.  相似文献   

10.

Objective

To prospectively evaluate the accuracy of left and right ventricular function and myocardial mass measurements based on a dual-step, low radiation dose protocol with prospectively ECG-triggered 2nd generation dual-source CT (DSCT), using cardiac MRI (cMRI) as the reference standard.

Materials and methods

Twenty patients underwent 1.5 T cMRI and prospectively ECG-triggered dual-step pulsing cardiac DSCT. This image acquisition mode performs low-radiation (20% tube current) imaging over the majority of the cardiac cycle and applies full radiation only during a single adjustable phase. Full-radiation-phase images were used to assess cardiac morphology, while low-radiation-phase images were used to measure left and right ventricular function and mass. Quantitative CT measurements based on contiguous multiphase short-axis reconstructions from the axial CT data were compared with short-axis SSFP cardiac cine MRI. Contours were manually traced around the ventricular borders for calculation of left and right ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction and myocardial mass for both modalities. Statistical methods included independent t-tests, the Mann–Whitney U test, Pearson correlation statistics, and Bland–Altman analysis.

Results

All CT measurements of left and right ventricular function and mass correlated well with those from cMRI: for left/right end-diastolic volume r = 0.885/0.801, left/right end-systolic volume r = 0.947/0.879, left/right stroke volume r = 0.620/0.697, left/right ejection fraction r = 0.869/0.751, and left/right myocardial mass r = 0.959/0.702. Mean radiation dose was 6.2 ± 1.8 mSv.

Conclusions

Prospectively ECG-triggered, dual-step pulsing cardiac DSCT accurately quantifies left and right ventricular function and myocardial mass in comparison with cMRI with substantially lower radiation exposure than reported for traditional retrospective ECG-gating.  相似文献   

11.

Objective

To assess prospectively the intra- and interobserver variability, accuracy, and prognostic value of right and left ventricular short-axis diameter (RVd and LVd) measurements for risk stratification in patients with pulmonary embolism (PE) using ECG-gated compared to non-gated CT.

Materials and methods

Sixty consecutive patients (33 women; mean age 58.7 ± 10.3 years) with suspicion of PE underwent both non-gated and ECG-gated chest CT. RVd and LVd on four-chamber views and intra- and interobserver agreements were calculated for both protocols. RVd/LVd ratios were calculated and were related to 30-days adverse clinical events using receiver operating characteristics with area-under-the-curve (AUC) analyses.

Results

Both inter- and intraobserver variability showed narrower limits of agreement for all measurements with ECG-gated as compared to non-gated CT. Diameter measurements were significantly lower using non-ECG-gated CT as compared to ECG-gated CT for RVd and LVd (both p < .05). The AUC for the RVd/LVd ratio from ECG-gated CT was significantly larger than that from non-gated CT (0.956, 95% CI: 0.768–0.999 versus 0.675, 95% CI: 0.439–0.860; p = .048).

Conclusion

RVd and LVd measurements from ECG-gated chest CT show less intra- and interobserver variability and more accurately reflect ventricular function. In our patient cohort ECG-gated chest CT allows better prediction of short-term outcome of patients with acute PE that needs to be validated in a larger outcome study.  相似文献   

12.

Aim

To investigate if there is any difference in evaluation of residual tumor size after neoadjuvant chemotherapy (NAC) and neoadjuvant endocrine therapy (NAE).

Methods

Seventy-eight tumors in 57 patients were prospectively enrolled. Residual tumor sizes in contrast-enhanced MRI after NAC and NAE were compared with those measured on surgical specimen by using linear regression analyses. The line slope values >1 indicates overestimation by MRI. Differences in types of shrinkage patterns: concentric shrinkage (CS) and dendritic shrinkage (DS) were also investigated.

Results

Fifty lesions were treated with NAC and 28 lesions were treated with NAE. Shrinkage patterns were CS in 33 lesions and in 45 lesions. The slopes values were 0.75 (R = 0.92) and 0.70 (R = 0.90) for NAC and NAE, respectively, and no significant difference was observed (p = 0.46). However, they were 1.02 (R = 0.92) and 0.68 (R = 0.92), respectively for CS and DS with significant difference (p < 0.01). The difference between CS and DS was found only in a subgroup with size by MRI >20 mm.

Conclusion

Contrast enhanced MRI enabled fairly accurate measurement in NAE as well as in NAC.  相似文献   

13.

Objectives

To investigate the ability of staging computed tomography (CT) without bowel preparation to accurately localize colonic tumors compared to optical colonoscopy.

Methods

The local institutional review board approved this retrospective and HIPAA-compliant study. Forty-six patients with colonic adenocarcinoma, preoperative colonoscopy, and staging CT within 60 days of resection were included. Patients underwent contrast enhanced CT imaging without bowel preparation or oral contrast. The colon was divided into four segments with the operative reports used as the standard. Rectal and cecal cancers were excluded. CT scans were reviewed by 5 readers in a segmental binary fashion using a 5-point confidence scale in two sessions blinded and unblinded to the colonoscopy report.

Results

At surgery 49 tumors were found in 46 patients. Readers detected 86.1%, 74.3%, and 66.9% of lesions with 92.0%, 94.1%, and 95.4% accuracy for confidence scores of ≥3, ≥4, and 5. CT interobserver agreement was good (κ = 0.82) for the unblinded and moderate (κ = 0.60) for the blinded read. Colonoscopic localization was only 78.7% accurate with 2 tumors undiscovered. Colonoscopic accuracy was low in the descending colon (57.1%) and the transverse colon (55.6%).

Conclusions

Preoperative staging CT is more accurate than colonoscopy in the localization of colonic tumors.  相似文献   

14.

Purpose

The aim of the study was to evaluate the diagnostic accuracy of multi-slice-computed tomography (MDCT) for the detection of vertebral metastases in comparison to magnetic resonance imaging (MRI).

Materials and methods

In a retrospective analysis, 639 vertebral bodies of 41 patients with various histologically confirmed primary malignancies were analysed. The MDCT-images were acquired on a 16/64-row-MDCT scanner (Siemens Somatom Sensation 16/64). MRI was performed on 1.5 T scanners (SIEMENS Symphony/Sonata). The MDCT- and MRI-images were evaluated separately by two experienced radiologists in a consensus reading. The combination of MDCT and MRI in an expert reading including follow-up examinations and/or histology as well as clinical data served as the gold standard.

Results

201/639 vertebral bodies were defined as metastatically affected by the gold standard. In MDCT 133/201 lesions, in MRI 198/201 lesions were detected. 68 vertebral bodies were false negative in MDCT, whereas 3 false negatives were found in MRI. 3 false positive results were obtained in MDCT, 5 in MRI. Sensitivity was significantly lower for MDCT (66.2%) than for MRI (98.5%) (p < 0.0001). Specificity was not significantly different for both methods (MDCT: 99.3%; MRI: 98.9%). The diagnostic accuracy resulted in 88.8% for MDCT and 98.7% for MRI.

Conclusion

Although 16/64-row-MDCT provides excellent image quality and a high spatial resolution in the assessment of bony structures, metastatic lesions without significant bone destruction may be missed. The diagnostic accuracy of MRI proved to be significantly superior to 16/64-row-MDCT for the detection of osseous metastases.  相似文献   

15.

Purpose

The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT).

Materials and methods

One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery.

Results

Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98).

Conclusion

Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.  相似文献   

16.

Background and purpose

Our aim was to investigate whether magnetic resonance imaging (MRI) with ferucarbotran administered prior to radiofrequency ablation could accurately assess ablative margin when compared with enhanced computed tomography (CT) with iodized oil marking.

Materials and methods

We enrolled 27 patients with 32 hepatocellular carcinomas in which iodized oil deposits were visible throughout the nodule after transcatheter arterial chemoembolization. For these nodules, radiofrequency ablation was performed after ferucarbotran administration. We then performed T2-weighted MRI after 1 week and enhanced CT after 1 month. T2-weighted MRI demonstrated the ablative margin as a low-intensity rim. We classified the margin into three grades; margin (+): high-intensity area with a continuous low-intensity rim; margin zero: high-intensity area with a discontinuous low-intensity rim; and margin (−): high-intensity area extending beyond the low-intensity rim.

Results

In 28 (86%) of 32 nodules, there was agreement between MRI and CT. The overall agreement between for the two modalities in the assessment of ablative margin was good (κ = 0.759, 95% confidence interval: 0.480–1.000, p < 0.001). In four nodules, ablative margins on MRI were underestimated by one grade compared with CT.

Conclusion

MRI using ferucarbotran is less invasive and allows earlier assessment than CT. The MRI technique performed similarly to enhanced CT with iodized oil marking in evaluating the ablative margin after radiofrequency ablation.  相似文献   

17.

Objective

To compare 128-slice multidetector computed tomography (MDCT) at 100 kVp and 120 kVp for image quality and radiation dose.

Materials and methods

Our study had approval of our institutional review board. We retrospectively selected 25 patients who underwent CT urography for the evaluation of hematuria. The CT scans were taken with 128-slice MDCT, with three phases (precontrast, nephrographic, and excretory), using an automatic tube current modulation with reference tube level of 180 mA s and tube voltages of either 100 kVp (n = 14, mean age 26.71) or 120 kVp (n = 11, mean age 25.54). The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) of the urinary tract, the subjective image quality of the urinary tract evaluated with a five point scale by two radiologists and the effective dose calculated on the basis of dose-length-product (DLP) and volume-CT-dose-index (CTDIvol) were compared between the groups with Student's t test or Mann–Whitney U test.

Results

There was no significant difference in the SNR (p = 0.358), CNR (p = 0.303) and the subjective image quality (p = 0.486) between the two protocols. The mean CTDIvol, DLP and the effective dose in the 100 kVp protocol were significantly lower than the 120 kVp protocol (p = 0.000, 0.000).

Conclusion

CT urography using 100 kVp protocol resulted in reduction of radiation dose without loss of objective or subjective image quality.  相似文献   

18.

Objective

The aim of this study was to investigate the value of dual energy spectral CT (DEsCT) imaging in preoperative diagnosis of insulinomas in comparison with conventional multi-detector CT (MDCT).

Materials and methods

Thirty-five patients were included in this study with 14 underwent the conventional dual-phase CT imaging (from March 2009 to January 2010) and 21 underwent the dual-phase DEsCT imaging (from February 2010 to May 2011). CT images were interpreted prospectively by two radiologists in consensus before operation. All the patients had diagnosis confirmed pathologically. The accuracy of preoperative diagnosis of insulinomas between DEsCT imaging and conventional MDCT, and between different kinds of images of DEsCT was compared.

Results

There were 39 confirmed lesions among the 35 patients (23 and 16 tumors in the spectral CT group and MDCT group, respectively). MDCT detected 11 of 16 tumors. DEsCT imaging detected 20 of 23 tumors separately with the monochromatic image or the iodine density image, and 22 of 23 tumors with the combination of the two kinds of images. The sensitivity for the preoperative diagnosis of insulinoma was 95.7% with the combination of monochromatic and iodine density images in DEsCT imaging, statistically higher than that with the conventional MDCT (68.8%) (p = 0.033).

Conclusion

Dual energy spectral CT imaging has higher sensitivity in preoperative diagnosis of insulinomas compared with conventional MDCT. The combination of monochromatic image and iodine density image can improve the diagnostic sensitivity of insulinomas.  相似文献   

19.

Objectives

To evaluate intraobserver and interobserver agreement of manually encompassed lung lesions for perfusion measurements using volume-perfusion computed tomography (VPCT).

Materials and methods

Institutional review board approval and informed consent were obtained. HIPAA guidelines were followed. A 65-s dynamic study was acquired with scan parameters 80 kV, 60 mA s (80 mA s for patients ≥70 kg), 128 × 0.6 mm collimation. Blood flow (BF), blood volume (BV) and Ktrans parameters were determined by syngo volume perfusion CT body with 88 lesions analyzed retrospectively.

Results

Within-subject coefficients of variation for intraobserver agreement (range 6.59–12.82%) were superior to those for interobserver agreement (range 21.75–38.30%). Size-dependent analysis revealed lower agreements for lesions <4 cm as compared to larger lesions. Additionally, agreements of the upper, middle and lower lung zones were different.

Conclusions

Intraobserver agreement was substantial for VPCT lung cancer perfusion measurements encouraging the use for tumor characterization and therapy response monitoring. Interobserver agreement is limited and unexperienced readers should be trained before using this new method.  相似文献   

20.

Purpose

To study the radiological appearance and pathological features of breast phyllodes tumors (PTs), and to enhance the recognition of the tumor.

Materials and methods

Clinical and imaging findings were retrospectively reviewed in 24 women with PTs confirmed by surgical pathology. All of the 24 patients had preoperative MRI and sonography, and 10 had preoperative mammography.

Results

The histologic findings were benign, borderline and malignant PTs in 16.7% (4/24), 45.8% (11/24) and 37.5% (9/24) of cases, respectively. The tumor size (p = 0.001), irregular shape on sonographic imaging (p = 0.039), internal non-enhanced septations (p = 0.009), silt-like changes in enhanced images (p = 0.006) and signal changes from T2-weighted to enhanced images on MRI (p = 0.001) correlated significantly with the histologic grade; the BI-RADS category of the MRI could reflect the PT's histologic grade with a correlation coefficient of 0.440 (p = 0.031). If the category BI-RADS ≥4a was considered to be a suspicious malignant lesion, the diagnostic accuracy of mammography, US and MRI would be 70% (7/10), 62.5% (15/24) and 95.8% (23/24), respectively.

Conclusion

The tumor size and several US and MRI findings can be used to help preoperatively determine the histologic grade of breast PTs. When a patient presents with a progressively enlarging, painless breast mass, MRI should be recommended first.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号