首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Nephropathia epidemica (NE), a less severe form of hemorrhagic fever with renal syndrome, is caused by Puumala virus (PUU). This communication reports the development of a mu-capture enzyme-linked immunosorbent assay (ELISA) for detection of specific immunoglobulin M (IgM) antibodies to PUU virus in human sera. Acute- and early-convalescent-phase sera (collected 1 to 41 days after disease onset) from 29 Swedish patients with clinical NE were tested for PUU virus-specific IgG and IgM antibodies by the indirect immunofluorescence test and ELISA, respectively. Late-convalescent-phase serum was also collected from 18 of these patients 3 to 24 months postinfection and assayed. The IgM ELISA values were strongly positive in sera collected during the first 2 months; at 3 to 9 months, they were negative or in the lower range of significance, and at 24 months all sera were negative. Paired sera from NE patients often fail to show seroconversion or a significant titer rise when tested by indirect immunofluorescence. Since all acute- and early-convalescent-phase sera were positive by IgM ELISA, this test could become an important tool for early diagnosis of acute human NE infections.  相似文献   

2.
The microenzyme-linked immunosorbent assay (ELISA) for the detection of immunoglobulin M and G (IgM, IgG) antibodies to Legionella pneumophila serogroup 1 antigens was evaluated. IgM antibodies were measured by both double-sandwich and single-sandwich techniques. These assays were compared with the previously standardized indirect immunofluorescence test in four groups of subjects: (i) pneumonia patients with culture-proven Legionnaires disease with serogroup 1 isolates, (ii) pneumonia patients with serogroup 1 organisms detected by direct immunofluorescence testing of respiratory secretions but without culture confirmation, (iii) pneumonia patients with negative culture and direct immunofluorescence tests, and (iv) healthy hospital employees. In addition, the sensitivity and specificity of the IgG ELISA were evaluated with larger groups of controls and Legionnaires disease patients. The ELISA was more sensitive than the indirect immunofluorescence test. However, it detected antibody rises in pneumonia patients without culture or direct immunofluorescence evidence of L. pneumophila serogroup 1 infection, thereby suggesting that the specificity of the ELISA was slightly lower than that of the indirect immunofluorescence test. The double-sandwich ELISA was a sensitive method for detecting IgM antibodies and, as previously reported, appeared to be free from interference by rheumatoid factor. IgM anti-Legionella antibodies detected by the ELISA appeared earlier and were less persistent than IgG antibodies. In addition, the IgM ELISA was useful in detecting antibodies in necropsy serum samples obtained from patients dying acutely of Legionnaires disease. The data presented show that the ELISA is a reliable method for the detection of specific anti-Legionella antibodies.  相似文献   

3.
Failure to demonstrate immunoglobulin M (IgM) antibodies by indirect immunofluorescence (IgM-IFA) in sera from some patients with acute acquired toxoplasmosis has recently been attributed to an inhibitory effect of high titers of IgG antibodies in these sera (Pyndiah et al. J. Clin. Microbiol. 9:170-174, 1979). To confirm these findings and define their importance for diagnosis, we used gel filtration to separate IgM from IgG antibodies in a series of sera that were negative in the IgM-IFA test. A total of 68 sera were from patients with acquired toxoplasmosis, 13 were from uninfected adults, 13 were from infants with congenital toxoplasmosis, and 7 were from uninfected neonates. Of the 68 sera from patients with acquired toxoplasmosis, IgM preparations (from the separated sera) were positive in the IgM-IFA test in 36 (53%). There was a significant (P = 0.00003) association between high titers of IgM-IFA antibodies in the IgM preparations (corrected for dilution of IgM antibodies by the gel filtration procedure) and recent acquisition of infection. IgM antibodies were also detected in 5 (38%) of the IgM preparations of 13 sera from congenitally infected infants but not in any of the IgM preparations of sera from uninfected neonates. IgG antibodies to Toxoplasma gondii were shown to interfere with demonstration of IgM antibodies in the IgM-IFA test. Treatment of sera with protein A resulted in greater dilution of IgM antibodies and less efficient separation of IgM from IgG antibodies than did separation of sera by gel filtration. Treatment of sera with protein A did not result in increased detection of IgM antibodies to T. gondii. Testing of IgM preparations (obtained by gel filtration) resulted in a significant increase in sensitivity of the IgM-IFA test for the diagnosis of recently acquired and congenital toxoplasmosis.  相似文献   

4.
An enzyme-linked immunosorbent assay (ELISA) for total antibodies to Toxoplasma gondii was modified to measure specific immunoglobulin M (IgM) antibodies. The assay requires three incubation periods totaling 2 h and enzyme-labeled-heavy-chain-specific antibodies to human IgM. The objective read-out in absorbance was normalized to percent of a standardized positive control for interpretations. No difference was observed between the assay results with or without previous absorption of the samples by Staphylococcus aureus protein A to remove most of the IgG antibodies. Addition of serum containing very high levels of IgG antibodies to another containing both IgG and IgM antibodies did not change the IgM assay values for the latter. None of the 22 sera containing high levels of IgM rheumatoid factor (RF) gave positive ELISA IgM results, even though 8 of them also had high levels of IgG toxoplasma antibodies. Mixtures of sera containing high concentrations of RF with sera having high levels of IgG toxoplasma antibodies also failed to show any false-positive reactions in the IgM toxoplasma assay. Thus, this ELISA for T. gondii IgM antibodies was not affected by IgG toxoplasma antibodies and RF.  相似文献   

5.
An indirect immunofluorescence test with total anti-human immunoglobulin conjugate (IgG,A,M-IIF) can be used for joint detection of immunoglobulin A (IgA) and IgM antibodies, provided serum IgG is previously absorbed with anti-human IgG. To determine the validity of the IgG,A,M-IIF assay with absorbed sera, the results obtained were compared with those obtained by methods routinely used for the detection of acute-phase markers, IgA and IgM IIF and enzyme immunoassay. Accordingly, 114 serum samples were selected from patients showing titers of > or = 1:1,024 by IgG,A,M-IIF. (i) In 90 of the samples, neither IgA nor IgM was detected by any of the methods employed; (ii) the remaining 24 samples showed IgA and/or IgM. In all cases, the IgG,A,M-IIF assay with absorbed sera was positive. These comparative data support the use of IgG,A,M-IIF, performed with absorbed and unabsorbed sera simultaneously, for determining the presence of specific IgG, IgA, and IgM by employing a single technique (IIF), one conjugate (anti-IgG,A,M), and only one sample (with and without previous absorption), thus providing a useful initial tool for the diagnosis of toxoplasmosis.  相似文献   

6.
A capture enzyme-linked immunosorbent assay (ELISA) for detection of virus-specific immunoglobulin M (IgM) antibody was developed which used a panel of labeled monoclonal antibodies to rubella virus hemagglutinin. The rapidity of the test system was increased by using, after 1-h incubation of the test serum, a second 1-h incubation of the serum with a mixture of viral antigen and labeled monoclonal antibody. The new assay was tested for specificity on 371 human sera from people without any recent contact with rubella virus; of these, 66 were sera selected from people with rheumatoid factor or IgM antibody to human cytomegalovirus, Epstein-Barr virus, or other viruses. In parallel, the new assay was performed on 191 sera from patients having recent contact with rubella virus. Results were compared with those obtained by an indirect ELISA method on IgM serum fractions, using purified rubella virus as a solid phase. Of the 371 sera tested for specificity, 5 (1.3%) gave false-positive results with indirect ELISA (1 rheumatoid factor, 2 heterophil antibody, and 2 human cytomegalovirus sera positive for IgM), and none were false-positive with the capture assay. Two sera from a patient with primary cytomegalovirus infection, which were positive for rubella IgM antibody with both methods and were initially interpreted as false-positive, were finally considered to be true-positive, since they were reactive only in the presence of IgM antibody and viral antigen. Of the 191 sera from 92 patients (84 patients with acute rubella, four newborns from mothers with rubella during pregnancy, and four vaccinees), 136 (71.2%) were found to be positive for IgM by direct ELISA, and 128 (67.0%) were positive by capture ELISA; 12 sera drawn during the first 2 days of disease, or at least 40 days after onset (or after vaccination), were detected only by indirect ELISA, and 4 sera were detected only by capture ELISA. Thus, specificity and sensitivity, respectively, were 100 and 91.4% for capture ELISA and 98.6 and 97.1% for indirect ELISA. However, when the number of patients was considered, 86 were detected as IgM positive by indirect ELISA, and 87 were detected positive by capture ELISA. The overall agreement between the two assays was 96.2%. Capture ELISA using monoclonal antibody appears preferable over indirect ELISA on IgM serum fractions because of its higher specificity and shorter time for test performance; furthermore, there is no need for serum fractionation or virus purification for the capture ELISA.  相似文献   

7.
A direct antibody capture enzyme immunoassay (EIA) for the detection of rubella-specific immunoglobulin M (IgM) antibody was developed. Polystyrene microtiter strips coated with rabbit anti-human IgM were used as solid phase, and a semipurified rubella antigen labeled with horseradish peroxidase was used as indicator. By testing a panel of 238 serum specimens (not including sera from newborns with congenital rubella), the direct EIA was compared with the indirect EIA used routinely in our diagnostic unit and with a commercial IgM capture EIA (RubEnz M II) that employs a horseradish peroxidase-labeled anti-rubella monoclonal antibody as indicator. Overall agreement of direct EIA with indirect EIA and RubEnz M II was 95%, whereas agreement between direct and indirect EIA was 96.2%, and agreement between direct EIA and RubEnz M II was 97.8%. Sensitivity of the direct assay was higher than that of the indirect EIA and similar to that of the RubEnz M II assay. Specific IgM antibody could always be detected in serum specimens taken from patients with primary acute rubella infection between days 4 and 56 after the onset of rash. The assay was highly specific, and it was not affected either by rheumatoid factor or by high levels of specific IgG in sera. Another important advantage that the direct EIA has over the indirect EIA is that it requires 10 to 20 times less antigen per serum specimen tested.  相似文献   

8.
Sera from 27 renal transplant patients with primary and recurrent CMV infections and which were known to contain CMV-specific IgM antibodies were investigated by indirect immunofluorescence for the presence of virus-specific high molecular weight IgM (19S IgM) and low molecular weight IgM (7S IgM). After sucrose gradient fractionation of the sera, 19S IgM was found in all 27 patients, whereas 7S IgM was present in 11 out of 19 (56%) patients with primary CMV infection and in 1 out of 8 (12%) patients with recurrent CMV infection. The presence of 7S IgM was unrelated to the titre of the virus-specific IgM in whole serum. The presence of IgM rheumatoid factor was monitored by a sensitive fluorescence assay using measles virus antigen/antibody complexes. The absorption of the serum fractions with heat-aggregated gamma globulin failed to remove the specific IgM staining indicating that it was not due to IgM rheumatoid factor. On the other hand adsorption with protein A/sepharose removed the specific IgM staining from the 7S IgM fractions but not from the 19S IgM fractions. This suggests that specific 19S and 7S IgM antibodies may belong to different subclasses of IgM.  相似文献   

9.
A solid-phase antibody capture hemadsorption (SPACH) assay was developed to detect hepatitis A virus (HAV)-specific immunoglobulin M (IgM) antibodies in sera from humans recently infected with hepatitis. The assay is performed with microtiter plates coated with anti-human IgM antibodies to capture IgM antibodies from the test sera. HAV-specific IgM antibody is detected by the addition of HAV hemagglutinating antigen and goose erythrocytes. Hemadsorption of erythrocytes to antigen-antibody complexes attached to the solid phase indicate the presence of IgM antibodies. The SPACH assay was compared to a commercial radioimmunoassay and was found to be equally or more sensitive and specific for the detection of HAV IgM antibodies. The SPACH assay is an alternative, rapid assay that doesn't require hazardous substrates or radioactivity for the detection of HAV-specific antibodies.  相似文献   

10.
An inhibition EIA using a monoclonal antibody against the major P30Toxoplasma gondii surface protein was designed for detection of specific antibodies in human sera. The assay was based on the inhibition of binding of peroxidase labelled monoclonal antibody toToxoplasma gondii crude antigen coated plates by the corresponding antibodies present in human sera. This rapid and simple assay was compared to indirect immunofluorescence, direct agglutination and an immunosorbent agglutination assay using 435 human sera. The specificity and sensitivity were 100 % and 97 % respectively. This test was found to be as sensitive as the dye test.  相似文献   

11.
Commercially available kits were used for the detection of Toxoplasma-specific IgM antibodies. False positive IgM results were observed in whole sera containing Toxoplasma-specific antibodies together with rheumatoid factor when tested by immunofluorescence (IFA). False negative IgM results occurred in whole sera containing competing levels of Toxoplasma-specific IgG antibodies, as indicated by the IFA:IgM-M ratio. False positive and false negative IgM results often occurred when whole sera were tested. These false reactions were eliminated by fractioning IgM from IgG using the Isolab's IgM Isolation System. All five sera in this study with an IFA titer to Toxoplasma of greater than or equal to 1:16,384 also contained Toxoplasma-specific IgM antibodies. This suggests that sera with high titers to Toxoplasma should be tested for Toxoplasma-specific IgM antibodies.  相似文献   

12.
A highly specific and sensitive hemadsorption immunosorbent technique for measuring rubella immunoglobulin M (IgM) antibody is described. IgM from human sera was absorbed into anti-human IgM-coated wells in plates and rubella-specific IgM was detected by adding rubella virus hemagglutinin and a small quantity of sheep erythrocytes. Centrifugation of the plates facilitated reading of the test. Specific IgM-positive sera showed hemadsorption, whereas negative sera showed hemagglutination. Rheumatoid factor and rubella-specific IgG antibody did not interfere with the results. The test was clearly more sensitive than the solid-phase immunosorbent technique for detection of rubella IgM antibody by hemagglutination inhibition and at least as sensitive as the hemagglutination inhibition test on IgM fractions from a sucrose density gradient and the indirect immunofluorescence test for IgM antibody with absorbed serum. All of 40 sera from 17 rubella patients taken 4 to 49 days after the onset of rash were positive in the new test, with antibody titers ranging from 2,560 to 81,920 between 4 and 28 days. The test is reliable, practical, and suitable for general diagnostic use.  相似文献   

13.
Two monoclonal antibodies CH6 and C1E3 were used in an antibody class capture assay for the detection of IgM antibodies specific for Toxoplasma gondii. CH6 was used on the solid phase to capture human IgM. After a Toxoplasma gondii antigen had been added, specifically bound material was detected using C1E3 coupled to horseradish peroxidase. The assay was compared with an established system using polyclonal antisera at both the capture and antigen detection stages. A good correlation was found, with 97.3% (125 of 128) of sera giving the same classification in both assays. Three sera were positive only in the polyclonal system. No false positive results were found when 118 negative sera were examined. The two monoclonal antibodies provide a viable alternative to the use of polyclonal sera at the capture and antigen detection stages in the antibody class capture assay for the measurement of specific IgM against T gondii.  相似文献   

14.
The double-sandwich enzyme-linked immunosorbent assay has been compared with the indirect fluorescence assay for the detection of immunoglobulin M antibodies against Toxoplasma gondii in humans. Incubation times have been shortened, permitting the test to be completed within 2 h. The double-sandwich enzyme-linked immunosorbent assay is confirmed to be more sensitive and more specific than the immunofluorescence assay.  相似文献   

15.
Sera from nine individuals with suspected primary herpes simplex virus type 1 (HSV-1) or type 2 (HSV-2) infection were screened to identify those containing HSV type-specific immunoglobulin M (IgM). Selected sera were then utilized in an IgM-specific indirect immunofluorescent-antibody HSV-typing assay (patent pending). To evaluate the procedure, 29 HSV isolates were grown in cultures of continuous human amnion cells, fixed, and used as substrates for indirect immunofluorescence. Determination of virus type was based on intensity of fluorescence of the substrate with HSV-1- and HSV-2-specific antisera after staining with fluorescein-conjugated anti-human IgM. Typing of the isolates by restriction endonuclease digestion showed that of 29, 18 were HSV-2 and 11 were HSV-1. Results by IgM-specific indirect immunofluorescent-antibody assay were identical to those by restriction endonuclease digestion for 27 of the isolates; 2 isolates failed to replicate adequately in the test cells. The IgM-specific indirect immunofluorescent-antibody procedure appears to be a simple, rapid, and accurate technique which could be of use to clinical virology laboratories.  相似文献   

16.
A sensitive and reproducible enzyme-linked immunosorbent assay (ELISA) is described for the detection of immunoglobulin M and antibodies with specifity for human cytomegalovirus (CMV) early (CMV-EA) and late (CMV-LA) antigens. The emphasis is on the production of high-quality CMV antigens, CMV-EA and CMV-LA separately, and conditions for their application in the ELISA. The induction of CMV-EA and -LA in infected cell extracts was studied in detail by using human sera with defined antibody specificity for CMV-EA and CMV-LA. This resulted in the development of a simple whole cell extraction procedure that provided a high yield of CMV antigens with reproducible antigen quality. The antigens were specific for the detection of anti-CMV antibodies. The influence of autoantibodies on the determination of CMV-specific antibodies was investigated. Parallel analysis of 322 human sera by indirect immunofluorescence and ELISA showed a high correlation between both assays (r = 0.9674 for CMV-EA and 0.9362 for CMV-LA). Antibody titers determined by ELISA were equal to (for CMV-EA) or slightly higher (for CMV-LA) that those determined by immunofluorescence but significantly higher (20- to 5,120-fold) than those determined by complement fixation. From 191 sera positive by ELISA (titer greater than or equal to 40) 4 (2.1%) were negative by immunofluorescence (titer less than 40), and from 61 ELISA-positive sera 12 (19.6%) were negative (titer less than 8) when tested by complement fixation. Consequently, ELISA for CMV may prove to be more reliable for the selection of CMV-seronegative blood donors than these other methods. The use of high-quality antigens allows more economic handling of large-scale serum determinations. Possibilities for further automation are discussed.  相似文献   

17.
The indirect enzyme-linked immunosorbent assay (ELISA) for detection of immunoglobulin M (IgM) antibodies toTreponema pallidum in sera of syphilitic patients is complicated by false positive reactions due to the interference of IgM rheumatoid factor (IgM-RF) activity and the presence of treponemal IgG antibodies. Another source of error producing false negative results is the competition between treponemal IgG and IgM antibodies for the binding sites on the antigen. To avoid these complications in the indirectTreponema pallidum-specific IgM-ELISA, total IgG was immunoprecipitated from sera of syphilitic patients prior to the assay. The IgM-RF from non-precipitated sera reacted in an IgM-RF-ELISA and in theTreponema pallidum-IgM-specific ELISA with identical titers. After precipitation of total IgG no reactíon of the IgM-RF in the assay could be demonstrated. Competition between IgG and IgM antibodies can be prevented almost completely by the precipitation procedure. The sensitivity and specificity of theTreponema pallidum-specific IgM-ELISA after immunoprecipitation of total serum IgG were shown to be higher than 97 percent.  相似文献   

18.
Enzyme-linked immunosorbent assay (ELISA) systems for serum IgG and IgM antibodies to human parvovirus B19 were established by utilizing anti-B19 monoclonal antibodies (mAbs) and human plasma B19 antigen. The specificities of IgG and IgM ELISA were confirmed by indirect immunofluorescence staining and Western blot immunoassay with panel sera. The series of serum specimens obtained from two B19-infected patients were examined with ELISA. The IgM antibody titers increased quickly after the onset of the symptoms and returned to a negative range after five months. The IgG antibody titers also increased just after the increasing of IgM titers and the elevated levels continued for more than a year. We also established the same ELISA systems by utilizing in vitro propagated B19 antigen and similar results were obtained.  相似文献   

19.
Two new methods for the detection of antibodies to Toxoplasma gondii, an enzyme-linked immunosorbent assay and a quantitative immunofluorescence assay, were evaluated and compared with the conventional indirect fluorescent-antibody slide test. Each of 100 human sera was assayed twice by the three procedures. Both the enzyme-linked immunosorbent assay and the quantitative immunofluorescence assay correlated well with serologically positive (indirect fluorescent-antibody titer greater than or equal to 1:32) and negative sera. The enzyme-linked immunosorbent assay was more specific, but less sensitive, than the quantitative immunofluorescence assay. However, the quantitative immunofluorescence assay was more reproducible and more rapid than the enzyme-linked immunosorbent assay.  相似文献   

20.
A reverse enzyme immunoassay (R-EIA) is described, in which polystyrene muplates are sensitized with anti-immunoglobulin M (IgM) (mu chain) antibodies and then sequentially allowed to react with patient's serum, peroxidase-labeled Toxoplasma gondii soluble antigen, and substrate. Measurement of activity of the solid-phase bound enzyme conjugate was done by colorimetric reading of the final developed color and kinetically by the initial rate of color development. This R-EIA allowed full resolution between absorbance values of a group of 36 sera which presented positive results in the Toxoplasma IgM immunofluorescence test and the remaining groups, which consisted of 39 normal individuals, 22 rheumatoid factor-positive sera, 8 Waldenstrom's macroglobulinemic sera, 3 infectious mononucleosis samples, and 6 high-titered IgG anti-T. gondii sera. No interference of rheumatoid factor IgM or inhibition by high-titered specific IgG was detected, even in the false IgM immunofluorescence-positive rheumatoid factor samples. Likewise, false-negative IgM immunofluorescence samples gave positive R-EIA even without adsorption with Staphylococcus aureus protein A. The possibility of direct tagging of the antigen with the enzyme eliminates the need for using antigen and anti-antigen conjugates as separate layers, therefore eliminating one step in the assay.  相似文献   