首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.

Purpose

The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT.

Materials and methods

A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A.

Results

Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05).

Conclusion

Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.  相似文献   

2.

Purpose

This study aimed at evaluating the computed tomography (CT) characteristics of resolving localized ground-glass opacities (GGOs) in a screening programme for lung cancer.

Material and methods

280 patients at high-risk for lung cancer (221 men, 59 women; mean age, 58.6 years), divided into four groups (lung cancer history (n = 83), head and neck cancer history (n = 63), symptomatic (n = 88) and asymptomatic (n = 46) cigarette smokers), were included in a prospective trial with annual low-dose CT for lung cancer screening. We retrospectively reviewed all localized GGOs, analyzed the CT characteristics on initial CT scans and changes during follow-up (median 29.1 months). Variables associated with resolution of GGOs were tested using chi-square or Mann-Whitney tests.

Results

A total of 75 GGOs were detected in 37 patients; 54.7% were present at baseline and 45.3% appeared on annual CT. During follow-up, 56.2% persisted and 43.8% disappeared. The resolving localized GGOs were significantly more often lobular GGOs (p = 0.006), polygonal in shape (p = 0.02), mixed (p = 0.003) and larger (p < 0.0001) than non-resolving localized GGOs.

Conclusion

Localized GGOs are frequent and many disappeared on follow-up. CT characteristics of resolving GGOs show significant differences compared to persistent ones. This study emphasizes the importance of short-term CT follow-up in subjects with localized GGOs.  相似文献   

3.

Objectives

To assess the effectiveness of adaptive iterative dose reduction (AIDR) and AIDR 3D in improving the image quality in low-dose chest CT (LDCT).

Materials and methods

Fifty patients underwent standard-dose chest CT (SDCT) and LDCT simultaneously, performed under automatic exposure control with noise index of 19 and 38 (for a 2-mm slice thickness), respectively. The SDCT images were reconstructed with filtered back projection (SDCT-FBP images), and the LDCT images with FBP, AIDR and AIDR 3D (LDCT-FBP, LDCT-AIDR and LDCT-AIDR 3D images, respectively). On all the 200 lung and 200 mediastinal image series, objective image noise and signal-to-noise ratio (SNR) were measured in several regions, and two blinded radiologists independently assessed the subjective image quality. Wilcoxon's signed rank sum test with Bonferroni's correction was used for the statistical analyses.

Results

The mean dose reduction in LDCT was 64.2% as compared with the dose in SDCT. LDCT-AIDR 3D images showed significantly reduced objective noise and significantly increased SNR in all regions as compared to the SDCT-FBP, LDCT-FBP and LDCT-AIDR images (all, P ≤ 0.003). In all assessments of the image quality, LDCT-AIDR 3D images were superior to LDCT-AIDR and LDCT-FBP images. The overall diagnostic acceptability of both the lung and mediastinal LDCT-AIDR 3D images was comparable to that of the lung and mediastinal SDCT-FBP images.

Conclusions

AIDR 3D is superior to AIDR. Intra-individual comparisons between SDCT and LDCT suggest that AIDR 3D allows a 64.2% reduction of the radiation dose as compared to SDCT, by substantially reducing the objective image noise and increasing the SNR, while maintaining the overall diagnostic acceptability.  相似文献   

4.

Objective

The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality.

Material and methods

Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mA s; collimation-2 × 32 × 0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test.

Results

Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P ≤ 0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2 ± 12.8 Hounsfield Units (HU), 204.8 ± 14.4 HU, 267.5 ± 18.6 HU, 311.9 ± 22.3 HU, 347.3 ± 24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P = 0.012 and P = 0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the weighting factor 0.6.

Conclusion

Different fusion factors used to create images in DECT cause statistically significant differences in CT value, SNR, CNR and image quality. Best results obtained using the weighting factor 0.6 for all anatomic structures used in this study.  相似文献   

5.

Purpose

The purpose of the study was to investigate the optimal scanning protocol of 64-slice CT angiography for assessment of coronary artery stents based on a phantom study.

Materials and methods

Coronary stents with a diameter of 2.5 mm was implanted in thin plastic tubes with an inner diameter of 3.0 mm to simulate a coronary artery. The tubes were filled with iodinated contrast medium diluted to 178 HU, closed at both ends and positioned in a plastic container filled with vegetable oil (−70 to −100 HU). A series of scans were performed with a 64-slice CT scanner with the following protocols: section thickness: 0.67 mm, 1.0 mm, 1.5 mm, 2.0 mm, pitch value: 0.2, 0.3, 0.5 and reconstruction interval of 50% overlap of the section thickness. 2D axial and multiplanar reformatted images were generated to assess the visibility of stent lumen, while virtual intravascular endoscopy (VIE) was reconstructed to evaluate the artery wall and stent surface.

Results

Our results showed that a scanning protocol of 1.0 mm slice thickness with a pitch of 0.3 produced acceptable images with best demonstration of the intrastent lumen and stent surface with minimal image noise or artifacts. In contrast, submillimeter scans with 0.67 mm resulted in moderate artifacts which affected visualization of the coronary lumen, in addition to the increased noise. When the section thickness increased to 1.5 mm and 2.0 mm, visualization of the artery wall and stent surface was compromised, although the intrastent lumen was still visible.

Conclusion

Our in vitro study suggested that a scanning protocol of 1.0 mm section thickness with pitch of 0.3 is the optimal protocol for evaluation of coronary artery stents as it allows generation of acceptable images with better visualization of stent lumen, stent surface and coronary artery wall.  相似文献   

6.

Background

To assess the added value of 80 kVp images to weighted average 120 kVp images for detecting hepatocellular carcinomas (HCCs) using dual-source, dual-energy MDCT.

Materials and methods

Forty-one HCCs in 42 patients who underwent liver transplantation (LT) were included. All patients underwent quadruple-phase CT using a 64-row dual-source, dual-energy MDCT with 80 kVp and 140 kVp. For 120 kVp, a linear blending ratio of 0.3 was chosen. Interval reviews for both simulated 120 kVp images without and with pure 80 kVp data were performed independently by two radiologists. They detected HCCs using a 4-point confidence scale. Tumor-to-liver contrast-to-noise ratio (CNR) was calculated and compared between the 80 kVp and simulated 120 kVp images. The additional diagnostic value of 80 kVp images was evaluated by jackknife alternative free-response receiver-operating characteristic (JAFROC) analysis.

Results

There were 41 HCCs on pathology and 37 of the 41 HCCs were depicted on CT scan. The mean CNR of the 37 HCCs in late arterial and portal-phase images was significantly better in the 80 kVp images than in 120 kVp images. The average JAFROC figure of merit, however, was not significantly improved when 80 kVp was added. Furthermore, the number of false-positives was significantly increased in reader 1 when adding 80 kVp data.

Conclusion

The addition of 80 kVp CT images to simulated 120 kVp images did not significantly improve the detection of HCCs despite of the significantly better CNR of 80 kVp images.  相似文献   

7.

Objectives

To determine the computed tomography (CT) features of adenomyosis in patients with known adenomyosis as established with magnetic resonance (MR) imaging.

Methods

A computerized search identified 16 women with pelvic MR diagnosis of adenomyosis who also had enhanced pelvic CT. Original CT reports were reviewed for potential prospective diagnosis of adenomyosis. CT images were reviewed for enhancement phase, inner and outer myometrium attenuation, uterine enlargement (width>6 cm), inner myometrial thickening (≥12 mm), and myometrial cysts.

Results

Adenomyosis was detectable on CT in 8 of 16 patients. For these 8 patients, inner and outer myometrium distinction was excellent in 7 (88%) and limited in 1 (12%), and mean inner myometrial thickness was 25 mm (range 14-47 mm). CT enhancement phase was parenchymal in 7 (88%), uterus was enlarged in 8 (100%), and 7 (88%) had myometrial cysts. Adenomyosis was focal in 5 (63%), diffuse in 2 (25%), and both in 1 (12%). None of the original CT reports included adenomyosis as a diagnosis.

Conclusions

CT can suggest a diagnosis of adenomyosis based on uterine enlargement, thickened inner myometrium, and/or myometrial cysts.  相似文献   

8.

Objective

The objective of our study was to prospectively evaluate the effectiveness of computed tomography (CT) histogram analysis method in the differentiation of benign and malignant adrenal masses.

Materials and Methods

Between March 2007 and June 2008, 94 patients (46 males, 48 females, age range: 30-79 years, mean age: 57.7 years) with 113 adrenal masses (mean diameter: 3.03 cm, range: 1.07-8.02 cm) were prospectively evaluated. These included 66 adenomas, 45 metastases and 2 pheochromocytomas. Histogram analysis method was performed using a circular region of interest (ROI) and mean attenuation, total number of pixels, number of negative pixels and subsequent percentage of negative pixels were detected on both unenhanced and delayed contrast-enhanced CT images for each adrenal mass. A mean attenuation threshold of 10 Hounsfield unit (HU) for unenhanced CT and 5% and 10% negative pixel thresholds for both unenhanced and delayed contrast-enhanced CT were calculated by a consensus of at least two reviewers and the correlation between mean attenuation and percentage of negative pixels was determined. Final diagnoses were based on imaging follow-up of minimum 6 months, biopsy, surgery and adrenal washout study.

Results

51 of 66 adenomas (77.3%) showed attenuation values of ≤10 HU and 15 (22.7%) adenomas showed more than 10 HU on unenhanced CT. All of these adenomas contained negative pixels on unenhanced CT. Eight of 66 (12.1%) adenomas showed a mean attenuation value of ≤10 HU on delayed contrast-enhanced scans and 45 adenomas (68.2%) persisted on containing negative pixels. All metastases had an attenuation value of greater than 10 HU on unenhanced CT images. 21 of 45 (46.6%) metastases contained negative pixels on unenhanced images but only seven metastases (15.5%) had negative pixels on delayed contrast-enhanced images. Two pheochromocytomas had negative pixels on both unenhanced and delayed contrast-enhanced CT images. Increase in the percentage of negative pixels yielded high correlation with mean attenuation decreases, both on unenhanced and delayed contrast-enhanced CT. Our sensitivity was 90.9% for the 10% negative pixel percentage threshold compared to 77.2% sensitivity for ≤10 HU mean attenuation threshold for unenhanced CT. Both methods gave a 100% specificity for the diagnosis of adenoma. We also obtained a 37.9% sensitivity for 5% negative pixel threshold and a slightly lower sensitivity of 28.8% for 10% negative pixel threshold compared to the 12.1% sensitivity of ≤10 HU mean attenuation threshold while maintaining 100% specificity for contrast-enhanced CT.

Conclusion

The CT histogram analysis is a simple and easily applicable method which provides higher sensitivity than the commonly used 10 HU threshold mean attenuation method of unenhanced CT and can replace it for the diagnosis of an adenoma. But with contrast-enhanced CT, although 100% specificity is being maintained, the sensitivities obtained are very poor for each method and is therefore likely to limit CT histogram analysis to be used as a clinically useful adjunct in the diagnosis of adenoma.  相似文献   

9.

Purpose

To compare objective and subjective image quality in neck CT images acquired at different tube current–time products (275 mA s and 340 mA s) and reconstructed with filtered-back-projection (FBP) and adaptive statistical iterative reconstruction (ASIR).

Materials and methods

HIPAA-compliant study with IRB approval and waiver of informed consent. 66 consecutive patients were randomly assigned to undergo contrast-enhanced neck CT at a standard tube-current–time-product (340 mA s; n = 33) or reduced tube-current–time-product (275 mA s, n = 33). Data sets were reconstructed with FBP and 2 levels (30%, 40%) of ASIR-FBP blending at 340 mA s and 275 mA s. Two neuroradiologists assessed subjective image quality in a blinded and randomized manner. Volume CT dose index (CTDIvol), dose-length-product (DLP), effective dose, and objective image noise were recorded. Signal-to-noise ratio (SNR) was computed as mean attenuation in a region of interest in the sternocleidomastoid muscle divided by image noise.

Results

Compared with FBP, ASIR resulted in a reduction of image noise at both 340 mA s and 275 mA s. Reduction of tube current from 340 mA s to 275 mA s resulted in an increase in mean objective image noise (p = 0.02) and a decrease in SNR (p = 0.03) when images were reconstructed with FBP. However, when the 275 mA s images were reconstructed using ASIR, the mean objective image noise and SNR were similar to those of the standard 340 mA s CT images reconstructed with FBP (p > 0.05). Subjective image noise was ranked by both raters as either average or less-than-average irrespective of the tube current and iterative reconstruction technique.

Conclusion

Adapting ASIR into neck CT protocols reduced effective dose by 17% without compromising image quality.  相似文献   

10.

Purpose

The aim of this study was to assess the anatomy of the mandibular lingual foramen (MLF) and its linked canals (mandibular lingual vascular canals - MLVC), describing their frequency, diameter, location, and course.

Materials and methods

One hundred and fourteen computed tomography (CT) images of the mandible (57 male and 57 female; mean age 44.70 ± 12.53; age range 13-75 years, were evaluated. The CT sections were obtained on axial plane by using a bone reconstruction algorithm and then processed with dedicated software (Dentascan), with a standard protocol.

Results

103 patients (90.35%) had at least one lingual vascular canal and 52 (45.61%) had multiple (two or three) canals. The typical locations of MLVC were the midline of the mandible (median lingual canal [MLC]). The mean diameter of the lingual canals in the midline (MLC) was 0.8 mm ± 0. The direction of MLC progresses in an anterior and slightly caudal sense.

Conclusions

Dental CT examination easily demonstrates the presence, position, direction and size of the lingual foramen and of the lingual vascular canals of the mandible. Radiologists and oral surgeons should be aware of these canals and their importance, in order to prevent bleeding complications during implants placement and other surgical procedures.  相似文献   

11.

Aim

The study aim was to compare the geometric accuracy of three-dimensional (3D) surface model reconstructions between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system.

Materials and methods

A dry human mandible was scanned with five CBCT systems (NewTom 3G, Accuitomo 3D, i-CAT, Galileos, Scanora 3D) and one MSCT scanner (Somatom Sensation 16). A 3D surface bone model was created from the six systems. The reference (gold standard) 3D model was obtained with a high resolution laser surface scanner. The 3D models from the five systems were compared with the gold standard using a point-based rigid registration algorithm.

Results

The mean deviation from the gold standard for MSCT was 0.137 mm and for CBCT were 0.282, 0.225, 0.165, 0.386 and 0.206 mm for the i-CAT, Accuitomo, NewTom, Scanora and Galileos, respectively.

Conclusion

The results show that the accuracy of CBCT 3D surface model reconstructions is somewhat lower but acceptable comparing to MSCT from the gold standard.  相似文献   

12.

Objective

The present study was performed to examine the dependence of image quality on in-plane position and direction in computed tomography (CT) imaging using the modulation transfer function (MTF), noise power spectrum (NPS) and analysis of signal-to-noise ratio (SNR). For detailed analysis of SNR, the low-contrast detectability was compared using simulated small low-contrast objects.

Materials and methods

Three models of multidetector-row CT (MDCT) were employed. The measurement positions for MTF were set to the isocentre and several peripheral areas, and NPS and SNR were calculated for the isocentre and 128 mm off-centre. To evaluate directional dependence, the one-dimensional physical properties were measured separately in the radial and azimuthal directions. Seven radiological technologists also performed a perceptual detection study at the different in-plane positions using computer-simulated low-contrast images.

Results

The results of MTF and SNR differed between the isocentre and the peripheral area. The MTF values also tended to decrease with distance from the isocentre, and the SNR values in the low frequency range for the peripheral area were superior to those for the isocentre. In the detection study, the low-contrast detectability in the peripheral area was 13-40% higher than the value in the isocentre.

Conclusion

The results of the present study indicated that clinical CT images have remarkable non-uniformity of image quality. Therefore, the detailed analysis performed in this study will provide useful information for the development of advanced image processing applications, such as computer-aided diagnosis (CAD) and de-noising of CT images.  相似文献   

13.

Purpose

The aim of this study was (a) to compare arterial enhancement in simultaneously acquired high- and low-kilovoltage images; and (b) to determine whether low tube-voltage imaging would permit PE evaluation on routine chest CT studies or CTPA studies performed with a low volume of contrast media.

Materials and methods

We compared 20 CTPA studies (CTPA group), 20 routine thoracic CT studies (RT group) and 10 CTPA studies performed with reduced volume of contrast media (RC group). HU values were measured in all groups at 80 kVp and 140 kVp images in multiple pulmonary arterial segments bilaterally. The diagnostic quality of the central and peripheral vascular enhancement and the image noise were evaluated at both energies using a five-point scale.

Results

For all patients, the mean CT attenuation values were greater at 80 kVp than 140 kVp images (p < 0.001). At 80 kVp, CTPA group attenuation values were greater than RT group (p = 0.03) with a similar trend at 140 kVp (p = 0.08). At both 140 kVp and 80 kVp, CTPA group attenuation values were greater than RC group (p = 0.02 and p = 0.03, respectively). Qualitative analysis showed that at 140 kVp CTPA studies had better global image quality scores than RT (p = 0.003) and RC (p = 0.001) groups. However, at 80 kVp, there was no significant difference of global image quality between CTPA and the other groups (p = 0.4 and p = 0.5, respectively). Although measurable image noise was greater at 80 kVp than 140 kVp (p < 0.001), qualitative analysis revealed lower image noise at 80 kVp images.

Conclusion

DECT at 80 kVp increases arterial enhancement in both CTPA and routine studies. For routine studies this results in central and peripheral enhancement quality equivalent to that of CTPA studies. Low tube-voltage imaging allows marked contrast volume reduction for CTPA. In selected cases, satisfactory lower radiation dose CT might be achievable using lower kVp imaging alone.  相似文献   

14.

Purpose

To compare diagnostic capability of preoperative N-staging of lung cancer between thin-section CT of the mediastinum and FDG PET, and 5 mm slice thickness CT.

Materials and methods

The subjects were 34 patients with lung carcinoma who were examined by both CT and PET, and subsequently underwent surgery between May 2005 and January 2007. CT was carried out with a 16 detector row helical CT scanner. The raw data were reconstructed into 5 mm slice thickness and 1 mm slice thickness (thin-section CT). A total of 251 lymph node stations were retrospectively assessed for the presence of lymph node metastasis with thin-section CT, 5 mm CT and PET. In the interpretations of thin-section CT and 5 mm CT, we employed multi-criteria as follows: nodular calcification and intranodal fat as benign criteria, and short-axis diameter more than 10 mm (size criterion), focal low density other than fat, surrounding fat infiltration and convex margin in hilar lymph nodes, as malignant criteria. On PET, maximum standardized uptake value (SUVmax) of 2.5 or more was used as the criterion of malignancy. Sensitivity and specificity were compared between these examinations using McNemar test.

Results

Sensitivities and specificities of thin-section CT, 5 mm CT and PET were 25%, 25%, 25%, and 97%, 94%, 98%, respectively. The statistical analysis revealed that the specificity of 5 mm CT was significantly lower than those of thin-section CT (p = 0.039) and PET (p = 0.006), while no difference was present between thin-section CT and PET.

Conclusion

Thin-section CT of the mediastinum using multiple criteria was comparable to PET in preoperative N-staging of lung cancer.  相似文献   

15.

Objective

In order to retrospectively evaluate the CT findings of abdominal aspergillosis in immunocompromised patients.

Materials and methods

CT scans were reviewed with regard to the sites, number, morphologic appearance, attenuation, and the contrast enhancement patterns of the lesions in six patients (5 women, 1 man; mean age, 43.4 years; range, 23-59 years) with pathologically proved abdominal aspergillosis by two gastrointestinal radiologists in consensus. Medical records were also reviewed to determine each patient's clinical status and outcome.

Results

All patients were immunocompromised state: 4 patients received immunosuppressive therapy for solid organ transplantation and 2 patients received chemotherapy for acute myeloid leukemia. Aspergillosis involved blood vessels (n = 3), liver (n = 2), spleen (n = 2), gastrointestinal tract (n = 2), native kidney (n = 1), transplanted kidney (n = 1), peritoneum (n = 1), and retroperitoneum (n = 1). CT demonstrated solid organ or bowel infarction or perforation secondary to vascular thrombosis or pseudoaneurysm, multiple low-attenuating lesions of solid organs presenting as abscesses, concentric bowel wall thickening mimicking typhlitis, or diffuse or nodular infiltration of the peritoneum and retroperitoneum.

Conclusion

Familiarity with findings commonly presenting as angioinvasive features or abscesses on CT, may facilitate the diagnosis of rare and fatal abdominal aspergillosis.  相似文献   

16.

Purpose

To obtain consistent CCTA image quality and patient dose optimization with an individualized tube current selection method based on analysis of CT scout scans.

Methods and materials

The study received a waiver of informed consent from the institutional review board. Initially 100 patients (Group A) underwent CCTA with a fixed mA. The scout view pixel value and CCTA image noise were measured. Their correlation was studied to establish a formula to determine the required mA for obtaining a CT exam with a specific image noise. One hundred patients (Group B) were then scanned with the formula-determined mA. CCTA image quality, image noise and effective dose from the two groups were statistically analyzed. CT findings for 32 Group B patients were compared with the conventional coronary angiography.

Results

An average CCTA image noise of 27.6 HU was obtained (target 27 HU) using the formula with more uniform image noise in Group B (standard deviation 2.4 HU) than in Group A (4.1 HU). There was no statistical difference between image quality scores for the two groups. The effective dose for Group B (7.8 mSv) was 30% lower than for Group A (11.2 mSv) (p < 0.01). CCTA sensitivity, specificity, positive predictive value, negative predictive value, and stenosis detection accuracy were 94.9%, 92.1%, 88.9%, 96.5% and 93.2%, respectively, for stenosis greater than 50%.

Conclusion

CCTA mA selection based upon the image characteristics of the CT scout view provides an individualized protocol that generates consistent image quality and helps to reduce overall patient dose.  相似文献   

17.

Objective

With the introduction of non-myeloablative hematopoietic cell transplantation, acute graft-versus-host-disease (GvHD) is frequently observed beyond the traditional 100 days cut-off.The aim of this study was to describe and compare CT features of gastrointestinal early and late-onset GvHD and to correlate findings with clinical and pathology grading.

Subjects and methods

Abdominal CT scans were obtained in 20 patients with early and 15 with late-onset GvHD. Examinations were assessed for intestinal and extraintestinal abnormalities and findings compared between the two subgroups of GvHD. Distinct CT abnormalities as well as a CT-score integrating multiple pathologies were correlated with gut, clinical or pathology grading.

Results

Frequent intestinal abnormalities included wall thickening, abnormal enhancement, and excessive fluid-filling (94%, 89%, and 94%). 86% of patients showed concomitant small and large bowel involvement. A discontinuous distribution was observed in 54%. Bile tract abnormality was the most common extra-intestinal finding (74%).The distribution of pathologies was equal between subgroups of early or late-onset disease.Wall thickening and mucosal attenuation in non-enhanced scans were significantly related to clinical and pathology scores (P ≤ 0.018). Number of abnormal segments, small bowel dilatation, engorgement of the vasa recta, mesenteric fat stranding and ascites were linked to clinical grading (P ≤ 0.019). A CT-score integrating multiple abnormalities was correlated to gut, overall clinical and pathology grading (r = 0.64, 0.57, 0.50).

Conclusion

CT morphology of acute GvHD is independent of its time of onset and, thus, facilitates differential diagnosis of late-onset acute GvHD. Correlation of CT morphology with clinical and pathological grading is important in terms of prognosis and may help guiding the therapeutic approach.  相似文献   

18.

Purpose

To evaluate whether dual-energy CT angiography (DE-CTA) could identify links between morphologic and functional abnormalities in chronic pulmonary thromboembolism (CPTE).

Materials and methods

Seventeen consecutive patients with CPTE without underlying cardio-respiratory disease were investigated with DE-CTA. Two series of images were generated: (a) transverse diagnostic scans (i.e., contiguous 1-mm thick averaged images from both tubes), and (b) perfusion scans (i.e., images of the iodine content within the microcirculation; 4-mm thick MIPs). Two radiologists evaluated by consensus the presence of: (a) pulmonary vascular features of CPTE and abnormally dilated systemic arteries on diagnostic CT scans, and (b) perfusion defects of embolic type on perfusion scans.

Results

Diagnostic examinations showed a total of 166 pulmonary arteries (166/833; 19.9%) with features of CPTE, more frequent at the level of peripheral than central arteries (8.94 vs 0.82; p < 0.0001), including severe stenosis with partial (97/166; 58.4%) or complete (20/166; 12.0%) obstruction, webs and bands (37/166; 22.3%), partial filling defects without stenosis (7/166; 4.2%), focal stenosis (4/166; 2.4%) and abrupt vessel narrowing (1/166; 0.6%). Perfusion examinations showed 39 perfusion defects in 8 patients (median number: 4.9; range: 1-11). The most severe pulmonary arterial features of CPTE were seen with a significantly higher frequency in segments with perfusion defects than in segments with normal perfusion (p < 0.0001). Enlarged systemic arteries were observed with a significantly higher frequency ipsilateral to lungs with perfusion defects (9/12; 75%) compared with lungs without perfusion defects (5/22; 22.7%) (p = 0.004).

Conclusion

Dual-energy CTA demonstrates links between the severity of pulmonary arterial obstruction and perfusion impairment, influenced by the degree of development of the systemic collateral supply.  相似文献   

19.

Objective

To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA).

Methods

100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP).

Results

At low heart rates (<70 bpm), image quality of SSCT was equivalent to that of DSCT (P > 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P < 0.05). The average effective dose of SSCT was 9.3 ± 0.9 mSv at low heart rates (<70 bpm) while, the average estimated effective doses of DSCT were 9.1 ± 1.3 mSv, 8.3 ± 1.1 mSv, 7.9 ± 1.1 mSv, 6.9 ± 0.7 mSv, and 5.9 ± 1.3 mSv, corresponding to heart rates of 50-59 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and 90-100 bpm.

Conclusion

For cardiac CTA, both DSCT and SSCT can get good image quality at low heart rates (<70 bpm) with a similar radiation dose, but, at high heart rates (>70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.  相似文献   

20.

Objective

To compare image quality, diagnostic accuracy and radiation dose of prospective and retrospective electrocardiogram (ECG) gated dual source computed tomography (DSCT) for the evaluation of the coronary stent, using conventional coronary angiography (CA) as a standard reference.

Design, setting and patients

Sixty patients (heart rates ≤70 bpm) with previous stent implantation who were scheduled for CA were divided in two groups, receiving either prospective or retrospective ECG gated DSCT separately. Two reviewers scored coronary stent image quality and evaluated stent lumen.

Results

There was no significant difference in image quality between the two groups. In the prospective group, there were 86.4% (51/59) stents with interpretable images, in the retrospective group, there were 87.5% (49/56) stents with interpretable images. Image quality was not influenced by age, body mass index or heart rate in either group, but heart rate variability had a weak impact on the image quality of the prospective group. Image noise was higher in the prospective group, but this difference reached statistical significance only by using a smooth kernel reconstruction. Per-stent based sensitivity, specificity, and positive and negative predictive value were 100%, 84.1%, 68.2%, and 100%, respectively, in the prospective CT angiography group and 94.4%, 86.8%, 77.3%, and 97.1%, respectively, in the retrospective CT angiography group. There was a significant difference in the effective radiation dose between the two groups, mean effective dose in the prospective and retrospective group was 2.2 ± 0.5 mSv (1.5-3.2 mSv) and 14.6 ± 3.3 mSv (10.0-20.4 mSv) (p < .001) respectively.

Conclusions

Compared with retrospective CT angiography, prospective CT angiography has a similar performance in assessing coronary stent patency, but a lower effective dose in selected patients with regular heart rates ≤70 bpm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏