首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Biomimetic calcium phosphate (Ca-P) coatings were applied onto dense titanium alloy (Ti6Al4V) and porous tantalum (Ta) cylinders by immersion into simulated body fluid at 37 degrees C and then at 50 degrees C for 24 h. As a result, a homogeneous bone-like carbonated apatitic (BCA) coating, 30 microm thick was deposited on the entire surface of the dense and porous implants. Noncoated and BCA-coated implants were press-fit implanted in the femoral diaphysis of 14 adult female goats. Bone contact was measured after implantation for 6, 12, and 24 weeks, and investigated by histology and backscattered electron microscopy (BSEM). After 6 weeks, bone contact of the BCA-coated Ti6Al4V implants was about 50%. After 12 and 24 weeks, bone contact was lower in comparison with the 6-week implantations at, respectively 24 and 39%. Regarding the BCA-coated porous Ta implants, bone contacts were 17, 30, and 18% after 6, 12, and 24 weeks, respectively. However, bone contact was always found significantly higher for BCA-coated dense Ti6Al4V and porous Ta cylinders than the corresponding noncoated implants. The results of this study show that the BCA coating enhances the bone integration as compared to the noncoated implants.  相似文献   

2.
In this study, porous 3D fiber deposition titanium (3DFT) and 3DFT combined with porous biphasic calcium phosphate ceramic (3DFT+BCP) implants, both bare and 1 week cultured with autologous bone marrow stromal cells (BMSCs), were implanted intramuscularly and orthotopically in 10 goats. To assess the dynamics of bone formation over time, fluorochrome markers were administered at 3, 6 and 9 weeks and the animals were sacrificed at 12 weeks after implantation. New bone in the implants was investigated by histology and histomorphometry of non-decalcified sections. Intramuscularly, no bone formation was found in any of the 3DFT implants, while a very limited amount of bone was observed in 2 BMSC 3DFT implants. 3DFT+BCP and BMSC 3DFT+BCP implants showed ectopic bone formation, in 8 and 10 animals, respectively. The amount of formed bone was significantly higher in BMSC 3DFT+BCP as compared to 3DFT+BCP implants. Implantation on transverse processes resulted in significantly more bone formation in composite structure as compared to titanium alloy alone, both with and without cells. Unlike intramuscularly, the presence of BMSC did not have a significant effect on the amount of new bone either in metallic or in composite structure. Although the 3DFT is inferior to BCP for bone growth, the reinforcement of the brittle BCP with a 3DFT cage did not negatively influence osteogenesis, osteoinduction and osteoconduction as previously shown for the BCP alone. The positive effect of BMSCs was observed ectopically, while it was not significant orthotopically.  相似文献   

3.
The aim of this work was to compare the osteogenicity of calcium phosphate ceramic granules with autologous bone graft in ectopic and orthotopic sites. Biphasic calcium phosphate (BCP) granules composed of hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP) in a 60/40 ratio were sintered at 1050, 1125 and 1200 degrees C, producing different microporosities. Either BCP ceramic granules or autologous bone chips (n=7) were implanted into paraspinal muscles. Osteoinduction was not observed in either the BCP implants or autologous bone chips after 6 or 12 weeks in the ectopic sites. Hollow and bored polytetrafluoroethylene (PTFE) cylinders were filled with autologous bone, BCP granules or left empty, then implanted into critical-sized defects in femoral epiphyses. The PTFE cylinders left empty contained marrow and blood vessels but not mineralized bone, indicating that this model prevented bone ingrowth (0.56+/-0.43% at 12 weeks). Bone formation was observed in contact with the BCP1050 and BCP1125 granules in the femoral sites after 6 weeks. The amount of bone after 12 weeks was 5.6+/-7.3 and 9.6+/-6.6% for BCP1050 and BCP1125, respectively. Very little bone formation was observed with the BCP1200 implants (1.5+/-1.3% at 12 weeks). In both the ectopic and orthotopic sites, autologous bone chips were drastically resorbed (from 19.4+/-3.7% initially to 1.7+/-1.2% at 12 weeks). This study shows that synthetic bone substitutes may have superior stability and osteogenic properties than autologous bone grafts in critical-sized bone defects.  相似文献   

4.
An in vivo study was carried out on uncoated and hydroxyapatite (HA)-coated nanostructured Ti13Nb11Zr alloy in comparison with high-grade Ti6Al4V, to investigate the effect of the different surfaces on osteointegration rate. A highly effective method to obtain a fast biomimetic deposition of a thin layer of nanocrystalline HA was applied to coat both substrates. Cylindrical pins were implanted in rabbit cortical bone and evaluated at 4 and 12 weeks by histomorphometry and microhardness tests. The results confirmed the ability of the slightly supersaturated Ca/P solution to induce a fast deposition of nanocrystalline HA on Ti alloys' surfaces. HA-coated Ti13Nb11Zr had the highest osteointegration rate at 4 and 12 weeks. Both HA-coated surfaces showed an affinity index significantly higher than those of native surfaces at 4 weeks (Ti13Nb11Zr+HA: 37%; Ti6Al4V+HA: 26%). Microhardness test showed a significantly higher bone mineralization index of HA-coated Ti13Nb11Zr in comparison with that of HA-coated Ti6Al4V surface. The study suggests that the HA coating on both alloys enhances bone response around implants and that there is a synergic effect of Ti-Nb-Zr alloy with the HA coating on bone remodeling and maturation.  相似文献   

5.
We have tested the efficacy of porous bioactive glass (BG) inlays in enhancement of implant osseointegration. A total of 24 sheep underwent bilateral surgical implantation of three parallel implants on the anteromedial cortical surface of each tibia. The disc-shaped implants made of Ti6Al4V or cobalt chromium (CoCr) alloys had two parallel surface grooves (trapezoidal space with bottom widening) filled with sintered 100% bioactive glass microspheres or a selected mixture of bioactive and biocompatible glass microspheres. The surface of uncoated control implants was smooth, grit-blasted or had unfilled grooves. A subgroup of control smooth CoCr implants was coated with two or three BG layers. Implant incorporation with bone was evaluated using torque testing to failure, scanning electron microscopy and morphometry at 12 and 25 weeks. A total of 144 in vivo implants and 16 ex vivo cemented control implants were analyzed. Control Ti6Al4V implants with unfilled trapezoidal grooves showed highest torsional failure loads with excellent ingrowth of new bone and remodeling of ingrown bone into lamellar bone. Implants with BG inlays and microroughened control Ti6Al4V implants showed significantly lower torsional failure loads than control Ti6Al4V implants with unfilled grooves. In conclusion, BG inlays failed to enhance biological implant fixation. Macrotextured surface was more effective than grit-blasting in promotion of mechanical incorporation.  相似文献   

6.
The corrosion behavior and cell adhesion property of nanostructured TiO2 films deposited electrolytically on Ti6Al4V were examined in the present in vitro study. The nanostructured TiO2 film deposition on Ti6Al4V was achieved via peroxoprecursors. SEM micrographs exhibit the formation of amorphous and crystallite TiO2 nanoparticles on Ti6Al4V before and after being annealed at 500 degrees C. Corrosion behavior of TiO2-deposited and uncoated Ti6Al4V was evaluated in freely aerated Hank's solution at 37 degrees C by the measurement and analysis of open-circuit potential variation with time, Tafel plots, and electrochemical impedance spectroscopy. The electrochemical results indicated that nano-TiO2 coated Ti6Al4V showed a better corrosion resistance in simulated biofluid than uncoated Ti6Al4V. Rat bone cells and human aortic smooth muscle cells were grown on these substrates to study the cellular responses in vitro. The SEM images revealed enhanced cell adhesion, cell spreading, and proliferation on nano-TiO2 coated Ti6Al4V compared to those grown on uncoated substrates for both cell lines. These results suggested that nanotopography produced by deposition of nanostructured TiO2 onto Ti alloy surfaces might enhance corrosion resistance, biocompatibility, and cell integration for implants made of Ti alloys.  相似文献   

7.
Bonit is claimed to be a resorbable electrochemically deposited calcium phosphate coating consisting mainly of brushite, which is a hydroxyapatite precursor. This study involved a comparison of Ti6Al4V screw-shaped implants with and without a 15 +/- 5 microm Bonit coating in rabbit tibia and femur, after 6 and 12 weeks of insertion. The biomechanical removal torque test showed significantly increased values for the coated implants after 12 weeks (p < 0.05) but not after 6 weeks of integration. Higher bone-implant contact was found for the coated implants in the tibia after 6 weeks and for both tibial and femoral screws after 12 weeks (p < 0.05). There was no difference in the inflammatory reaction around the implants, and possible grains of the coating could be detected after 6 weeks, but not after 12 weeks of follow-up. This unloaded short-term study has shown promising results for the easily applicable and resorbable coat (Bonit) compared to uncoated titanium-alloy implants.  相似文献   

8.
It was the purpose of this study to examine the osseointegration of laser-textured titanium alloy (Ti6Al4V) implants with pore sizes of 100, 200, and 300 microm, specifically comparing 200-microm implants with polished and corundum-blasted surfaces in a rabbit transcortical model. Using a distal and proximal implantation site in the distal femoral cortex, each animal received all four different implants in both femora. The bone-implant interface and the newly formed bone tissue within the pores and in peri-implant bone tissue were examined 3, 6, and 12 weeks post-implantation by static and dynamic histomorphometry. Here we show that additional surface blasting of laser-textured Ti6Al4V implants with 200-microm pores resulted in a profound improvement in osseointegration, 12 weeks postimplantation. Although lamellar bone formation was found in pores of all sizes, the amount of lamellar bone within pores was linearly related to pore size. In 100-microm pores, bone remodeling occurred with a pronounced time lag relative to larger pores. Implants with 300-microm pores showed a delayed osseointegration compared with 200-microm pores. We conclude that 200 microm may be the optimal pore size for laser-textured Ti6Al4V implants, and that laser treating in combination with surface blasting may be a very interesting technology for the structuring of implant surfaces.  相似文献   

9.
Titanium and titanium alloys are often used for orthopedic and dental implants. Osseointegration of Ti6Al4V may be improved not only by precoating of the surface with extracellular matrix proteins like collagen type I but also by additional immobilization of growth factors. In the present study, transforming growth factor beta1 (TGF-beta1) which is known as an inducer of collagen synthesis was immobilized adsorptively on uncoated and collagen type I coated Ti6Al4V surfaces. TGF-beta1 was found immobilized slightly faster to collagen type I coated than to uncoated Ti6Al4V and released slower from the collagen coated material. Immobilized TGF-beta1 is biologically active for at least 3 weeks storage at 4 degrees C. Sterilization by ethylene oxide inactivates immobilized TGF-beta1. In osteoblasts cultured on implants with adsorptively immobilized TGF-beta1, mRNA level and specific catalytic activity of alkaline phosphatase as well as accumulation of calcium and phosphate were found reduced, whereas procollagen alpha1(I) mRNA level and the rate of collagen synthesis were increased.  相似文献   

10.
The aim of the present study was to analyze the in vivo effect of biomimetic calcium phosphate coating of titanium implants on periimplant bone formation and bone-/implant contact. Five types of implants were used: 1) Ti6Al4V implants with a polished surface; 2) Ti6Al4V implants with collagen coating; 3) Ti6Al4V implants with a mineralized collagen layer; 4) Ti6Al4V implants with sequential coating of hydroxyapatite (HA) and collagen; and 5) Ti6Al4V implants with HA coating only. All implants had square cross sections with an oblique diameter of 4.6 mm and were inserted press fit into trephine burr holes of 4.6 mm in the mandibles of ten beagle dogs. The implants of five animals each were evaluated after a healing period of 1 month and 3 months, respectively, during which time sequential fluorochrome labeling of bone formation had been performed. Bone formation was evaluated by morphometric measurement of the newly formed bone around the implants and the percentage of implant bone contact. After 1 month, there was a significantly higher percentage of mean bone/implant contact in the HA-coated implants compared to those with polished surface and those with the collagen-coated surface. After 3 months, these differences were not present anymore. Bone apposition was significantly higher next to implants with sequential HA/collagen coating compared to polished surfaces and mineralized collagen layer. It is concluded that biomimetic coating of titanium implants with HA has shown the clearest trend to increase bone-implant contact in the early ingrowth period. The addition of collagen to an HA coating layer may hold some promise when used as sequential HA/collagen coating with mineralized collagen as the surface layer.  相似文献   

11.
The host response to titanium alloy (Ti–6Al–4V) is not always favorable as a fibrous layer may form at the skeletal tissue–device interface, causing aseptic loosening. Recently, sphene (CaTiSiO5) ceramics were developed by incorporating Ti in the Ca–Si system, and found to exhibit improved chemical stability. The aim of this study is to evaluate the in vitro response of human osteoblast-like cells, human osteoclasts and human microvascular endothelial cells to sphene ceramics and determine whether coating Ti–6Al–4V implants with sphene enhances anchorage to surrounding bone. The study showed that sphene ceramics support human osteoblast-like cell attachment with organized cytoskeleton structure and express increased mRNA levels of osteoblast-related genes. Sphene ceramics were able to induce the differentiation of monocytes to form functional osteoclasts with the characteristic features of f-actin and αvβ3 integrin, and express osteoclast-related genes. Human endothelial cells were also able to attach and express the endothelial cell markers ZO-1 and VE-Cadherin when cultured on sphene ceramics. Histological staining, enzyme histochemistry and immunolabelling were used for identification of mineralized bone and bone remodelling around the coated implants. Ti–6Al–4V implants coated with sphene showed new bone formation and filled the gap between the implants and existing bone in a manner comparable to that of the hydroxyapatite coatings used as control. The new bone was in direct contact with the implants, whereas fibrous tissue formed between the bone and implant with uncoated Ti–6Al–4V. The in vivo assessment of sphene-coated implants supports our in vitro observation and suggests that they have the ability to recruit osteogenic cells, and thus support bone formation around the implants and enhance osseointegration.  相似文献   

12.
This study tested the hypothesis that the rate and the extent of bone formation adjacent to porous, coated Ti-6Al-4V implants are differentially affected by the type of bioactive ceramic coating. Forty-eight rabbits received cylindrical Ti-6Al-4V intramedullary distal femoral implants bilaterally. Implants for the right limbs were coated with 45S5 Bioglass (45S5). Implants used for the left limbs either were coated with tricalcium phosphate/hydroxyapatite (HA) or were left uncoated as controls (CTL). The 45S5-coated implants histologically and biomechanically were compared to HA-coated and CTL implants at 4, 8, 12, and 16 weeks. After 12 and 16 weeks of healing, more bone and thicker trabeculae were measured histomorphometrically within the implant pores for the 45S5-coated implants compared to the HA-coated and CTL implants (p < 0.05). With time the HA-coated and CTL groups exhibited a significant decline in percent of bone and of trabecular thickness (p < 0.05) while the 45S5-coated implants did not. Biomechanical analyses indicated similar shear strengths for all treatment groups. In summary, 45S5-coated implants exhibited greater bone ingrowth compared to HA-coated and CTL implants, and they maintained their mechanical integrity over time.  相似文献   

13.
We have investigated pellet-shaped implants prepared from biphasic calcium phosphate (BCP) ceramics with five different ratios of hydroxyapatite (HAP) to beta tricalcium phosphate (beta-TCP). The purpose of this study was to evaluate these BCP ceramics as carriers for rhBMP-2. BCP ceramics impregnated with the different doses of recombinant human bone morphogenetic protein 2 (rhBMP-2) (1, 5 and 10g) were used for the experimental purpose and the ceramics without rhBMP-2 were used as control. The pellets were placed into subcutaneous pockets on the dorsum of 4-week-old male Wistar rats. The animals were sacrificed 2 and 4 weeks after implantation. Bone induction was estimated by alkaline phosphatase (ALP) activity measured at 2 weeks after implantation. Pellets were also examined radiologically, histologically and histomorphometrically. The results showed that all experimental pellets exhibited new bone formation whereas the control pellets produced only fibrous connective tissue. Here, 100% HAP ceramic showed most amount of bone formation, whereas 25% HAP to 75% TCP ceramic produced the bone least in amount among different BCP ceramics at the end of 4 weeks. This study indicates that formation of new bone depends on the ceramic content with high HAP-TCP ratio and high dose of rhBMP-2.  相似文献   

14.
Yuan H  Yang Z  De Bruij JD  De Groot K  Zhang X 《Biomaterials》2001,22(19):2617-2623
Bone induction by different calcium phosphate biomaterials has been reported previously. With regard to (1) whether the induced bone would disappear with time due to the absence of mechanical stresses and (2) whether this heterotopically formed bone would give rise to uncontrolled growth, a long-time investigation of porous hydroxyapatite ceramic (HA), porous biphasic calcium phosphate ceramic (TCP/HA, BCP), porous alpha-tricalcium phosphate ceramic (alpha-TCP) and porous beta-tricalcium phosphate ceramic (beta-TCP) was performed in dorsal muscles of dog, for 2.5 years. Histological observation, backscattered scanning electron microscopy observation and histomorphometric analysis were made on thin un-decalcified sections of retrieved samples. Normal compact bone with bone marrow was found in all HA implants (n = 4) and in all BCP implants (n = 4), 48 +/- 4% pore area was filled with bone in HA implants and 41 +/- 2% in BCP implants. Bone-like tissue, which was a mineralised bone matrix with osteocytes but lacked osteoblasts and bone marrow, was found in all beta-TCP implants (n = 4) and in one of the four alpha-TCP implants. Both normal bone and bone-like tissues were confined inside the pores of the implants. The results show that calcium phosphate ceramics are osteoinductive in muscles of dogs. Although the quality and quantity varied among different ceramics, the induced bone in both HA and BCP ceramics did neither disappear nor grow uncontrollably during the period as long as 2.5 years.  相似文献   

15.
Biphasic calcium phosphate (BCP) ceramics consisting of hydroxyapatite (HA) and tricalcium phosphate (TCP) has been used as a bone graft material during the last decade. In this paper, we report the bone in-growth induced by BCP ceramic in the experimentally created circular defects in the femur of dogs. This BCP ceramic consists of 55% hydroxyapatite (HA) and 45% b-tricalcium phosphate (TCP) prepared in situ by the microwave method. The defects were created as 4-mm holes on the lateral aspect of the femur of dogs and the holes were packed with the implant material. The defective sites were radiographed at a period of 4, 8, and 12 weeks postoperatively. The radiographical results showed that the process of ossification started after 4 weeks and the defect was completely filled with new woven bone after 12 weeks. Histological examination of the tissue showed the formation of osteoblast inducing the osteogenesis in the defect. The collageneous fibrous matrix and the complete Haversian system were observed after 12 weeks. The blood serum was collected postoperatively and biochemical assays for alkaline phosphatase activity were carried out. The measurement of alkaline phosphatase activity levels also correlated with the formation of osteoblast-like cells. This microwave-prepared BCP ceramic has proved to be a good biocompatible implant as well as osteoconductive and osteoinductive materials to fill bone defects.  相似文献   

16.
17.
Our purpose was to evaluate the osteointegration of bilayered calcium phosphate (CaP)-coated femoral hip stems in a canine model. A first layer of hydroxyapatite (HA) 20 microm thick and a superficial layer of Biphasic Calcium Phosphate (BCP) 30 microm thick were plasma-sprayed on to the proximal region of sandblasted Ti6Al4V prostheses. Bilayered CaP-coated and non-coated canine femoral stems were implanted bilaterally under general anesthesia in 6 adult female Beagle dogs. After 6 and 12 months, a significant degradation of the bilayered coating occurred with a remainder of 33.1+/-12.4 and 23.6+/-9.2 microm in thickness, respectively. Lamellar bone apposition was observed on bilayered coated implants while fibrous tissue encapsulation was observed on non-coated femoral stems. The bone-implant contacts (BIC) were 91+/-3% and 81+/-8% for coated and 7+/-8% and 8+/-12% for non-coated implants, at 6 and 12 months, respectively. Our study supports the concept of a direct relationship between the biodegradation of CaP coating and the enhanced osteointegration of titanium prostheses. A bilayered CaP coating might therefore enhance bone apposition in the early stages because of the superior bioactivity of the BCP layer while the more stable HA layer might sustain bone bonding over long periods.  相似文献   

18.
Calcium phosphate (Ca-P) coatings have been applied onto titanium alloys prosthesis to combine the srength of metals with the bioactivity of Ca-P. It has been clearly shown in many publications that Ca-P coating accelerates bone formation around the implant. However, longevity of the Ca-P coating for an optimal bone apposition onto the prosthesis remains controversial. Biomimetic bone-like carbonate apatite (BCA) and Octacalcium Phosphate (OCP) coatings were deposited on Ti6Al4V samples to evaluate their in vitro and in vivo dissolution properties. The coated plates were soaked in alpha-MEM for 1, 2, and 4 weeks, and they were analyzed by Back Scattering Electron Microscopy (BSEM) and by Fourier Transform Infra Red spectroscopy (FTIR). Identical coated plates were implanted subcutaneously in Wistar rats for similar periods. BSEM, FTIR, and histomorphometry were performed on the explants. In vitro and in vivo, a carbonate apatite (CA) formed onto OCP and BCA coatings via a dissolution-precipitation process. In vitro, both coatings dissolved overtime, whereas in vivo BCA calcified and OCP partially dissolved after 1 week. Thereafter, OCP remained stable. This different in vivo behavior can be attributed to (1) different organic compounds that might prevent or enhance Ca-P dissolution, (2) a greater reactivity of OCP due to its large open structure, or (3) different thermodynamic stability between OCP and BCA phases. These structural and compositional differences promote either the progressive loss or calcification of the Ca-P coating and might lead to different osseointegration of coated implants.  相似文献   

19.
3D microenvironment as essential element for osteoinduction by biomaterials   总被引:16,自引:0,他引:16  
In order to unravel the mechanism of osteoinduction by biomaterials, in this study we investigated the influence of the specific surface area on osteoinductive properties of two types of calcium phosphate ceramics. Different surface areas of the ceramics were obtained by varying their sintering temperatures. Hydroxyapatite (HA) ceramic was sintered at 1150 and 1250 degrees C. Biphasic calcium phosphate (BCP) ceramic, consisting of HA and beta-tricalcium phosphate (beta-TCP), was sintered at 1100, 1150 and 1200 degrees C. Changes in sintering temperature did not influence the chemistry of the ceramics; HA remained pure after sintering at different temperatures and the weight ratio of HA and beta-TCP in the BCP was independent of the temperature as well. Similarly, macroporosity of the ceramics was unaffected by the changes of the sintering temperature. However, microporosity (pore diameter <10 microm) significantly decreased with increasing sintering temperature. In addition to the decrease of the microporosity, the crystal size increased with increasing sintering temperature. These two effects resulted in a significant decrease of the specific surface area of the ceramics with increasing sintering temperatures. Samples of HA1150, HA1250, BCP1100, BCP1150 and BCP1200 were implanted in the back muscles of Dutch milk goats and harvested at 6 and 12 weeks post implantation. After explantation, histomorphometrical analysis was performed on all implants. All implanted materials except HA1250 induced bone. However, large variations in the amounts of induced bone were observed between different materials and between individual animals. Histomorphometrical results showed that the presence of micropores within macropore walls is necessary to make a material osteoinductive. We postulate that introduction of microporosity within macropores, and consequent increase of the specific surface area, affects the interface dynamics of the ceramic in such a way that relevant cells are triggered to differentiate into the osteogenic lineage.  相似文献   

20.
A new biomimetic method for coating metal implants enables the fast formation of dense and homogeneous calcium phosphate coatings. Titanium alloy (Ti6Al4V) disks were coated with a thin, carbonated, amorphous calcium phosphate (ACP) by immersion in a saturated solution of calcium, phosphate, magnesium, and carbonate. The ACP-coated disks then were processed further by incubation in calcium phosphate solutions to produce either crystalline carbonated apatite (CA) or octacalcium phosphate (OCP). The resorption behavior of these three biomimetic coatings was studied using osteoclast-enriched mouse bone-marrow cell cultures for 7 days. Cell-mediated degradation was observed for both carbonated apatite and octacalcium phosphate coatings. Numerous resorption lacunae characteristic of osteoclastic resorption were found on carbonated apatite after cell culture. The results showed that carbonated apatite coatings are resorbed by osteoclasts in a manner consistent with normal osteoclastic resorption. Osteoclasts also degraded the octacalcium phosphate coatings but not by classical pit formation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号