首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
BACKGROUND: The rapid diagnosis of influenza can alter the management of a patient's illness, resulting in reduced antibiotic usage, correct use of influenza antivirals and reduced length of stay in hospital emergency departments. The rapid tests have also been used to detect outbreaks in institutions and may play a role in pandemic influenza control. OBJECTIVES: To test six different rapid influenza tests, in a head-to-head comparison for the detection of seasonal influenza types A and B, compared to laboratory-based tests. STUDY DESIGN: One hundred and seventy-seven clinical specimens taken from mostly paediatric patients between June and October 2006 were tested using six influenza diagnostic tests and three laboratory-based techniques (immunofluorescence, cell culture and real-time RT-PCR). RESULTS AND CONCLUSION: Compared with cell culture, five of the rapid tests (Binax Now Influenza A&B, Directigen EZ Flu A+B, Denka Seiken Quick Ex-Flu, Fujirebio Espline Influenza A&B-N, and Quidel QuickVue Influenza A+B Test) demonstrated a similar influenza A sensitivity of between 67-71% and a specificity of 99-100%, however one rapid test (Rockeby Influenza A Antigen Test) had a significantly lower influenza A sensitivity of only 10% (specificity was 100%). For the five kits that detected influenza B antigen, sensitivity was considerably lower than that seen for influenza A (sensitivity for all the kits was 30%), although the number of specimens containing influenza B viruses was low.  相似文献   

4.
QuickVue influenza rapid diagnostic test (Quidel Corp., San Diego, CA, USA) was compared with the classical shell vial assay for evaluation of influenza virus clearance in patients treated with antiviral drugs. The shell vial assay was carried out on nasopharyngeal samples obtained from volunteers for a neuraminidase-inhibitor clinical trial protocol with 24 h or less from the onset of symptoms of influenza before the use of antiviral (day 1). Follow-up included samples collected after 24 and 72 h of therapy (day 2 and 4). The rapid test was retrospectively carried out in frozen samples. Test results on 99 samples from 33 adults were compared and the shell vial assay was considered the gold standard. The overall rate of detection for the shell vial assay was 39.4% and for QuickVue was 35.5%, with a concordance of 79.8%. The sensitivity obtained for QuickVue was 74.4% and the specificity was 82.7%. Comparison of test results day by day in the follow-up resulted: day 1, higher sensitivity of QuickVue test (85.5%, 24/29); day 2, agreement on positive and negative results between QuickVue and shell vial was 60.6% (20/33); day 4, all test results in samples collected after 72 h of therapy were negative. The QuickVue test showed good sensitivity for the diagnosis of influenza-like illnesses. This rapid test kit can be an alternative tool for interventions in disease management.  相似文献   

5.
6.
7.
From November 2004 to April 2007, specimens were obtained from 2,281 patients with acute respiratory tract illness in Normandy, France. Eighteen strains of influenza C virus were detected in these samples using a combined tissue culture/RT-PCR diagnostic method. Most patients with influenza C virus infection (13/18) were infants or young children (<2 years of age). The most frequent symptoms were fever and cough, and the clinical presentation of influenza C virus infection was similar to that of other respiratory viruses. Thirteen of the 18 infected patients were hospitalized; 3 presented with a severe lower respiratory infection. The hemagglutinin-esterase (HE) gene of 10 isolates was sequenced to determine the lineages of the circulating influenza C viruses. Phylogenetic analysis revealed that most of the isolated strains had an HE gene belonging to the C/Yamagata/26/81-related lineage. These results show that influenza C virus regularly circulates in Normandy and generally causes a mild upper respiratory infection. Because the differential clinical diagnosis of influenza C virus infection is not always easy, it is important to identify viral strains for both patient management and epidemiological purposes.  相似文献   

8.
Exploiting the high sensitivity of the chemiluminescence phenomenon, an accurate and sensitive point-of-care test, called the ZstatFlu-II test (ZymeTx, Inc., Oklahoma City, Okla.), was developed to detect influenza virus infections. The ZstatFlu-II test takes 20 min and requires approximately 2 min of "hands-on" time for operational steps. The ZstatFlu-II test does not distinguish between infections with influenza virus types A and B. ZstatFlu-II test results are printed on Polaroid High-Speed Detector Film, allowing test results to be archived. A prototype version of the ZstatFlu-II test was evaluated during the 2000-to-2001 flu season with 300 nasal aspirate specimens from children at a pediatric hospital. Compared to culture, the ZstatFlu-II test had 88% sensitivity and 92% specificity. The Directigen test had a sensitivity of 75% and a specificity of 93%. The sensitivity of the ZstatFlu-II test was significantly higher than that of the Directigen test (P < 0.0574).  相似文献   

9.
Directigen FLU-A, a new enzyme immunoassay membrane test, rapidly detects influenza A virus antigen in specimens from patients. Nasopharyngeal washes and pharyngeal gargles were used to determine the effectiveness of the assay as applied to different types of routinely collected clinical samples. All specimens had been previously shown to contain influenza A virus by virus isolation in tissue culture. Directigen FLU-A was 90% sensitive (95% confidence interval, 56 to 99.7%) with nasopharyngeal washes but only 39% sensitive (95% confidence interval, 17 to 64%) with pharyngeal gargles (P = 0.018) when used with samples containing similar amounts of infectious virus (50% tissue culture infective dose, 1.0 to 4.5). The intensity of the positive reaction with Directigen FLU-A did not correlate with the amount of virus in the specimens. Directigen FLU-A was found to detect cell-associated antigen more readily than free virus; only 20 infected cells were required to identify cell-associated influenza A virus antigen, whereas the limit of detection for free virus was 1.63 x 10(3) infectious virus particles. These findings suggest that Directigen FLU-A detects the cell-associated antigen present in clinical specimens rather than free virus. In addition, Directigen FLU-A detected avian and swine influenza A viruses in both cloacal swabs (75% sensitivity) and swine lung homogenates (86% sensitivity), indicating its potential usefulness in the surveillance of nonhuman influenza A viruses.  相似文献   

10.
11.
The early detection of pandemic influenza strains is a key factor for clinicians in treatment decisions and infection control practices. The aims of this study were to determine the analytical sensitivity and clinical performance of the commercially available influenza rapid tests in Taiwan. Four rapid tests for influenza virus (BinaxNow test, QuickVue test, TRU test, and Formosa Rapid test) were evaluated for their detection limit against four influenza viruses (the 2009 pandemic influenza A virus H1N1, seasonal influenza virus H1N1, H3N2, and influenza B virus) circulating in Taiwan. The viral load of these isolates were quantified by rtRT-PCR and then diluted 2-fold serially for the comparison. The lowest detectable viral load of the pandemic influenza A virus H1N1 by the Formosa Rapid test, QuickVue test, TRU test, and Binax Now test was 5.3 × 104, 1.0 × 105, 1.0 × 105, and 4.2 × 105 copies/μL, respectively. Of these four tests, the two most sensitive tests (the QuickVue test and the Formosa Rapid test) were chosen to evaluate 62 nasopharyngeal specimens from patients who were suspected of infection with pandemic influenza A virus H1N1. The positive rate for the Formosa Rapid test and the QuickVue test were 53.2% (33/62) and 45.2% (28/62) (McNemar's test, P = 0.125), respectively. In conclusion, the Formosa Rapid test was the most sensitive test in the present study for the detection of influenza antigens and its clinical performance was similar to that of the QuickVue test (Kappa = 0.776). This suggests that the Formosa Rapid test could be used to aid clinical decision making in primary health care settings during outbreaks of influenza.  相似文献   

12.
13.
14.
15.
16.
17.
The rapid detection of influenza viruses is important for forming preventative strategies, directing initiation of anti-viral therapy, detecting potential avian influenza viruses, and excluding influenza-like pathogens, such as SARS. The ImmunoCard STAT! Flu A and B Plus test (Meridian Bioscience, Cincinnati, OH) is a new point of care (POC) test utilizing influenza-specific monoclonal antibodies for rapid diagnosis. The performance of this assay was compared to the established POC Binax NowFlu A and NowFlu B test, and the reference diagnostic standards of viral culture, indirect immunofluorescence (IFA), and RT-PCR where appropriate. Testing of nasopharyngeal aspirates (NPA) from children, throat swabs, and nasal swabs from adults indicated ImmunoCard STAT! specificity of 98% and 100% for influenza A and B, respectively in 224 specimens. The Binax test showed specificity of 99% and 100%, respectively for influenza A and B. Sensitivity results were identical for both rapid detection kits (80% and 47% for Flu A and B, respectively). Overall results were very similar for both testing devices with the advantage of ImmunoCard STAT! Flu A and B Plus test detecting influenza A and B with sharp and easy to read results.  相似文献   

18.
A multiplex real-time PCR assay was developed with a LightCycler instrument for detection of influenza viruses A and B and the human respiratory syncytial virus (HRSV). Detection of each viral product and of an internal control was based on determination of specific melting temperatures by the LightCycler software. The lower limit of detection in the multiplex PCR assay was found to be 50 copies for each viral target. In an evaluation of nasopharyngeal samples collected from hospitalized children (ages, 0 to 3 years) with acute respiratory tract infections during the winter of 2001 to 2002, a viral pathogen was detected by the multiplex PCR test in 139 (66.8%) of 208 cases, including 45 (21.6%) influenza A virus infections, no (0%) influenza B virus infections, 106 (51%) HRSV infections, and 12 (5.8%) coinfections. The multiplex PCR test was compared to rapid antigen detection assays for influenza viruses A and B (Directigen; Becton Dickinson, Sparks, Md.) and HRSV (RSV TestPack; Abbott Laboratories, Abbott Park, Ill.) in 172 and 204 samples, respectively. After resolution of discrepant test results by use of additional PCR assays targeting other viral genes, the sensitivity (Se) and specificity (Sp) of the multiplex PCR assay for influenza A virus were 100 and 97.7% compared to 43.6 and 98.5% for the antigenic test. Similarly, the Se and Sp of the multiplex PCR assay for HRSV were 94.5 and 98.9% compared to 81.6 and 94.7% for the antigenic test. In conclusion, our multiplex real-time PCR assay combines both rapidity and sensitivity for detecting the most important respiratory viral pathogens in children.  相似文献   

19.
Directigen FLU-A, an enzyme immunoassay membrane test, was compared prospectively to isolation in cell culture and direct immunofluorescence (IF) for the detection of influenza A virus. One hundred ninety specimens were evaluated by Directigen FLU-A and cell culture; 184 of these specimens were also tested by direct IF. The sensitivity of Directigen FLU-A compared to isolation in cell culture and direct IF was 100%. The specificities of Directigen FLU-A compared to isolation and direct IF were identical, 91.6%. Fourteen specimens that were positive by Directigen FLU-A did not yield virus in culture; two of the specimens, however, were positive by direct IF, and four other specimens were not specimens of choice for the test. A positive Directigen result had positive predictive values of 62.6 and 75.0% compared to isolation and direct IF, respectively; a positive Directigen result with an intensity reading of 2+ or greater, however, had positive predictive values of 85 and 100% compared to isolation and direct IF, respectively. In all comparisons, the negative predictive value was 100%. There was no evidence that cross-reactivity occurred with non-influenza A antigens. Directigen FLU-A should serve as a convenient screening test for influenza A and as a rapid test supported by isolation in cell culture during an influenza outbreak.  相似文献   

20.
The performance of a lateral-flow immunoassay, the QuickVue Influenza Test, for detection of influenza A and B viruses in comparison with that of cell culture was evaluated by using nasopharyngeal aspirates, in viral transport medium, from children with respiratory tract infections. The sensitivity and specificity were 79.2 and 82.6%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号