首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
目的:探讨真空辅助活检装置(Mammotome)手术常见问题的处理体会。方法:266例患者,329枚乳房肿块,经超声检查诊断均为乳房占位,在超声引导下行麦默通微创旋切治疗。结果:超声引导麦默通微创旋切治疗过程中病变均能清晰显示,引导成功率100%。1例出现皮肤损伤,1例出现切除部位出血、21例出现皮下青紫,发生率5.65%(23/266)。术后3个月超声随访,3例原病灶附近出现新病灶,复发率0.11%。结论:超声引导下麦默通微创旋切手术治疗乳腺肿块具有安全、准确、创伤小、恢复快等优点。  相似文献   

3.
PURPOSE: To measure the effect of biopsy device, probe size, mammographic lesion type, lesion size, and number of samples obtained per lesion on the ductal carcinoma in situ (DCIS) underestimation rate. MATERIALS AND METHODS: Nonpalpable breast lesions at 16 institutions received a histologic diagnosis of DCIS after 14-gauge automated large-core biopsy in 373 lesions and after 14- or 11-gauge directional vacuum-assisted biopsy in 953 lesions. The presence of histopathologic invasive carcinoma was noted at subsequent surgical biopsy. RESULTS: By performing the chi(2) test, independent significant DCIS underestimation rates by biopsy device were 20.4% (76 of 373) of lesions diagnosed at large-core biopsy and 11.2% (107 of 953) of lesions diagnosed at vacuum-assisted biopsy (P <.001); by lesion type, 24.3% (35 of 144) of masses and 12.5% (148 of 1,182) of microcalcifications (P <.001); and by number of specimens per lesion, 17.5% (88 of 502) with 10 or fewer specimens and 11.5% (92 of 799) with greater than 10 (P <.02). DCIS underestimations increased with lesion size. CONCLUSION: DCIS underestimations were 1.9 times more frequent with masses than with calcifications, 1.8 times more frequent with large-core biopsy than with vacuum-assisted biopsy, and 1.5 times more frequent with 10 or fewer specimens per lesion than with more than 10 specimens per lesion.  相似文献   

4.
OBJECTIVE: The aim of our study was to determine the false-negative rate of stereotactic 11-gauge vacuum-assisted biopsy in a validation study of lesions that had subsequent surgical excision. MATERIALS AND METHODS: Retrospective review was performed of 318 lesions that underwent stereotactic 11-gauge vacuum-assisted biopsy and subsequent surgical excision. A false-negative case was defined as a pathologically proven cancer in which stereotactic biopsy yielded benign results without atypia. Medical records, imaging studies, and histologic findings were reviewed. RESULTS: False-negative findings were encountered at stereotactic 11-gauge vacuum-assisted biopsy in 3.3% (7/214) of pathologically proven cancers. False-negative findings occurred in 3.5% (4/115) of malignant calcification lesions versus 3.0% (3/99) of malignant masses (p = 1.0). The seven false-negative findings included five Breast Imaging Reporting and Data System (BI-RADS) category 5 lesions that yielded benign results at biopsy, one BI-RADS category 4 mass that benign breast tissue, and one BI-RADS category 4 cluster of calcifications in which no calcifications were retrieved. The false-negative rate was 10.0% (6/60) for radiologists who performed 15 or fewer previous stereotactic vacuum-assisted biopsy procedures versus 0.6% (1/154) for radiologists who performed more than 15 previous stereotactic vacuum-assisted biopsy procedures (p = 0.002). CONCLUSION: Stereotactic 11-gauge vacuum-assisted biopsy had a false-negative rate of 3.3% that diminished to 0.6% with experience. All false-negative findings could be prospectively identified because of failure to sample calcifications or imaging-histologic discordance.  相似文献   

5.
Fine-needle aspiration for cytologic diagnosis was performed on 219 nonpalpable breast lesions by using a stereotactic localization technique. Cytologic results were correlated with mammographic findings, and therapeutic decisions were based on the results of both procedures. Representative cytologic material was obtained in 74% of the lesions. Strict criteria of representativeness were observed. If only cases with representative cytologic yield are considered, the sensitivity was 93% and the specificity was 97%. The predictive values were high except for the predictive value of a negative cytologic finding in a spiculated lesion (50%). Sampling errors caused by abundant fibrosis, needle deviation, and difficulty in defining the lesion on the stereoscopic views are discussed. Another source of sampling error may be the mixed nature of some lesions consisting of benign and malignant components. Fine-needle aspiration of 219 nonpalpable breast lesions by using a stereotactic localization device yielded representative cytologic samples in 74% of the lesions.  相似文献   

6.
7.
PURPOSE: The purpose of this study was to assess the benefits of stereotactic vacuum-assisted breast biopsy in patients with non-palpable microcalcification detected on mammography. METHODS: Between October 2001 and November 2003, stereotactic Mammotome biopsies were performed for 150 microcalcified lesions on mammography using the prone-type stereotactic vacuum-assisted breast biopsy system (Mammotest and Mammovision, Fischer, Denver, USA) . The mammography findings were classified according to the guidelines of The Japan Radiological Society/The Japan Association of Radiological Technologists. Ninety-eight cases were category 3, 38 were category 4, and 14 were category 5. RESULTS: All cases were determined to be cases of microcalcification by specimen radiography or histology. Complications were negligible. One hundred twenty of the cases were mastopathy, and 30 of them were breast cancer (14 were ductal carcinoma in situ, 7 were ductal carcinoma in situ with microinvasion, and 9 were invasive ductal carcinoma). Twenty-seven breast cancers were diagnosed as category 4 or 5 (51.9%) on mammography. The operative stages of 27 cases were as follows: 7 were stage 0, 17 were stage 1, and 3 were stage 2A. Twenty-four of 27 (88.9%) were early breast cancers. CONCLUSION: Mammotome biopsy is a safe and useful modality for the histological diagnosis of non-palpable microcalcifications.  相似文献   

8.
9.
OBJECTIVE: The purpose of this prospective study was to assess the accuracy of an add-on stereotactic unit for core needle biopsy of mammographic lesions. SUBJECTS AND METHODS. Between September 1994 and February 2001, 506 stereotactic core needle biopsies of mammographic lesions in 492 patients were performed in our center on a mammography unit with add-on stereotactic equipment. Of the initial 92 patients, 80 underwent stereotactic core needle biopsy and surgical excision simultaneously. In subsequent cases, surgical biopsy was performed after core biopsy in patients who had malignant or atypical histologic results or discordance between mammographic and pathologic findings. Follow-up mammography was advised for all patients whose core biopsy results were diagnosed as benign lesions. RESULTS: Histologic results for 506 lesions undergoing stereotactic core needle biopsy were as follows: 113 (22.3%) were malignant; 369 (72.9%), benign; and 24 (4.7%), atypical. Of 113 malignant lesions identified at stereotactic core needle biopsy, 111 were confirmed as malignant, whereas two showed no evidence of malignancy at surgical excision. Of 369 lesions diagnosed as benign at stereotactic core needle biopsy, 172 (46.6%) showed no change on follow-up mammography, 114 (30.9%) were lost to follow-up, and 83 (22%) underwent surgical excision. Of 24 lesions with atypical histology, 23 had surgical follow-up, six were malignant, nine were benign, and eight were confirmed as showing atypical histology. Stereotactic core needle biopsy of the 506 lesions was complicated by five (1.0%) cases of vasovagal attack and four (0.8%) cases of bleeding. The resulting sensitivity, specificity, and positive and negative predictive values were 98.3%, 93.0%, 86.0%, and 99.2% respectively. CONCLUSION: Biopsy with an add-on unit is safe, reliable, accurate, and cost-effective with results comparable to those reported for dedicated prone biopsy devices.  相似文献   

10.
Soo MS  Ghate S  Delong D 《Clinical imaging》1999,23(6):469-352
The purpose of this study was to evaluate the stereotactic 14-gauge, vacuum-assisted biopsy technique in diagnosing noncalcified breast lesions. Stereotactic biopsy of 116 noncalcified breast lesions was performed with either 14-gauge, vacuum-assisted technique or multipass, automated large-core technique. The number of core samples and time required for each biopsy were compared. Outcome for each technique was compared based on recommendations after the mammographic-histologic review process. Results from surgical excision and mammographic follow-up were reviewed. The vacuum-assisted technique obtained more tissue cores per lesion than the automated gun technique, showed marginal decrease in number of repeat biopsies for discordant results, and required fewer short-term follow-up mammograms, although the difference did not achieve statistical significance. The vacuum-assisted technique can be used successfully to sample noncalcified breast masses, with marginal improvement over the automated gun technique.  相似文献   

11.
立体定位导丝导向活检不能触及的乳腺病灶   总被引:22,自引:0,他引:22  
目的 探讨立体定位导丝导向活检不能触及的乳腺病灶的价值。方法 对25例不能触及的乳腺病灶行立体定位导丝导向活检26处,对每处病灶计算出穿刺针针尖至病灶中心的距离(D),并直接测量出留置的导丝头端至病灶中心的距离作对照,判断标准:优:D小于等于2.5mm;良:D=2.6-4.9mm;差:D大于等于5.0mm。结果 定位优20例次,良5例次,差1例次。穿刺针针尖至病灶中心距离的计算值与直接测量值相符,1次性病灶切除26例次,标本体积的中位数为10.5cm3,检出乳腺癌6(6/26)处;结论 立体定位导丝导向活检不能触及的乳腺病灶能以最小的手术范围完整切除病灶,定位定性效果确切,可避免假阴性,提高了乳腺癌的早期检出率及诊断准确性。  相似文献   

12.
13.
RATIONALE AND OBJECTIVES: To determine the diagnostic accuracy of stereotactically and sonographically guided core biopsy (CB) for the diagnosis of nonpalpable breast lesions. MATERIALS AND METHODS: Twenty-two institutions enrolled 2,403 women who underwent imaging-guided fine needle aspiration followed by imaging-guided large-CB of nonpalpable breast abnormalities. All mammograms were reviewed for study eligibility by one of two breast imaging radiologists. The protocol for image-guided biopsy, using either ultrasound (USCB) or stereotactic (SCB) guidance, was standardized at all institutions and all biopsy specimens were over-read by one of three expert pathologists. Patients with atypical ductal hyperplasia (ADH), atypical lobular hyperplasia, or lobular neoplasia on CB underwent surgical excision. Those with negative CB but suspicious ("discordant") pre-biopsy mammography also underwent surgical excision. Patients having a negative CB that was concordant with the pre-biopsy mammography suspicion were assigned to follow-up mammography at 6, 12, and 24 months following CB. RESULTS: A gold standard diagnosis based on definitive histopathologic diagnosis, mammography follow-up, or an imputed gold standard diagnosis was established for 1,681 patients. Of 310 cases with a gold standard diagnosis of invasive breast carcinoma, 261 (84.2%) were invasive carcinoma, 31 (10%) were ductal carcinoma in situ (DCIS), four (1.3%) were ADH, one (0.3%) was a non-breast cancer, and 13 (4.2%) were benign on CB. For 138 cases with a gold standard diagnosis of DCIS, 113 (81.9%) were DCIS, 20 (14.5%) were ADH, and five (3.6%) were benign on CB. For 57 cases (13 masses, 44 calcifications) with an initial CB diagnosis of ADH, atypical lobular hyperplasia or lobular neoplasia, 20 (35.1%) had a gold standard diagnosis of DCIS (4 masses, 16 calcifications) and four (7.0%) had a gold standard diagnosis of invasive cancer (4 calcifications). Of 144 cases (22 masses, 122 calcifications) with an initial CB diagnosis of DCIS, 31 (21.5%) had a gold standard diagnosis of invasive cancer (10 masses, 21 calcifications). The sensitivity, specificity and accuracy for CB by either imaging guidance method in this trial were .91, 1.00, and .98, respectively. The sensitivity, predictive value negative, and accuracy of CB for diagnosing masses (.96, .99, and .99, respectively) were significantly greater (P < .001) than for calcifications (.84, .94, and .96, respectively). The sensitivity (.89) of SCB for diagnosing all lesions was significantly lower (P = 0.029) than that of USCB (.97) because of the preponderance of calcifications biopsied by SCB versus USCB. There was no difference between USCB and SCB in sensitivity, predictive value negative, or accuracy for the diagnosis of masses (97.3, 98.9, and 99.2, respectively for USCB; 95.6, 98.5, and 98.9 respectively for SCB). CONCLUSION: Percutaneous, imaged-guided core breast biopsy is an accurate diagnostic alternative to surgical biopsy in women with mammographically detected suspicious breast lesions.  相似文献   

14.
15.
16.
PURPOSE: The purpose of this study was to assess the accuracy and clinical usefulness of stereotactic vacuum-assisted biopsy (VAB) for diagnosing suspicious, nonpalpable, only mammographically detectable breast lesions. MATERIALS AND METHODS: We retrospectively evaluated the results of percutaneous stereotactic VAB with 11-gauge needles performed over a period of 34 months on 228 nonpalpable suspicious breast lesions detectable on mammography only [Breast Imaging Reporting and Data System (BI-RADS) 3: 25.9%; BI-RADS 4: 67.1%; BI-RADS 5: 7%]. The imaging histological concordance was ascertained for each lesion. In cases of discordance, repeat biopsy or surgical excision were recommended; in cases of benign lesions, we urged a follow-up of at least 6 months and for borderline and malignant lesions a surgical excision. We also evaluated concordance between VAB results and subsequent examinations (surgical excision or followup). RESULTS: VAB demonstrated 123 (54%) benign lesions (with six cases of imaging-histological discordance), 26 (11.4%) borderline lesions and 79 (34.6%) malignant lesions. We obtained a suitable post-VAB mammographic or histological evaluation for 78 benign lesions, 17 borderline lesions and 76 malignant lesions, with one (1.3%) false negative (FN) case, two (11.8%) underestimations of borderline lesions, 14 (18.4%) underestimations of malignant lesions and no (0%) false positive cases. We did not observe any postbiopsy complications or scars. CONCLUSIONS: Percutaneous histological VAB with an 11-gauge needle proved to be, as reported in previous studies, a reliable method for diagnosing nonpalpable, mammographically detectable only breast lesions, with an underestimation rate lower than core biopsy and a FN rate similar to that of surgical biopsy, without any significant complications.  相似文献   

17.

Purpose

The authors sought to evaluate the diagnostic accuracy and cost-effectiveness of vacuum-assisted core biopsy (VACB) in comparison with diagnostic surgical excision for characterisation of nonpalpable breast lesions classified as Breast Imaging Reporting and Data System (BI-RADS) categories R3 and R4.

Materials and methods

From January 2004 to December 2008, we conducted 602 stereotactic, 11-gauge, VACB procedures on 243 nonpalpable breast lesions categorised as BI-RADS R3, 346 categorised as BI-RADS R4 and 13 categorised as BI-RADS R5. We calculated the diagnostic accuracy and cost savings of VACB by subtracting the cost of the stereotactic biopsy from that of the diagnostic surgical procedure.

Results

A total of 56% of the lesions were benign and required no further assessment. Lesions of uncertain malignant potential (B3) (23.6%) were debated at multidisciplinary meetings, and diagnostic surgical biopsy was recommended for 83.1% of them. All malignant lesions (B4 and B5) underwent surgical excision. VACB had a sensitivity of 94.9%, specificity of 98.3% and diagnostic accuracy of 97.7%. The cost savings per VACB procedure were 464.00 euro; by obviating 335 surgical biopsies, the overall cost savings was 155,440.00 euro over 5 years.

Conclusions

VACB proved to have high diagnostic accuracy for characterising abnormalities at low to intermediate risk of malignancy and obviated surgical excision in about half of the cases, allowing for considerable cost savings.  相似文献   

18.
A decision model was used to compare the relative costs of the 14-gauge automated gun technique to the 14-gauge and 11-gauge vacuum-assisted techniques for stereotactic biopsy of noncalcified breast lesions. Probability and cost variables were estimated from clinical experience with 76 automated gun biopsies, seventy-eight 14-gauge vacuum-assisted biopsies and thirty-nine 11-gauge vacuum-assisted biopsies. The 14-gauge automated gun was the preferred strategy from a cost standpoint: the 14-gauge vacuum technique was 1.19 times more expensive, and the 11-gauge was 1.22 times more expensive.  相似文献   

19.
Norris TG 《Radiologic technology》2001,72(5):431-50; quiz 451-4
This overview of stereotactic breast biopsy describes the procedure's advantages over surgical biopsy as well as contraindications for its use. Patient and procedural considerations are discussed, along with the equipment used, technologist qualifications and imaging and positioning techniques. The article concludes with a discussion of quality assurance requirements.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏