首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Thirty six patients were received epidural anesthesia with or without buprenorphine (BPN) during upper abdominal surgery. They were divided into three groups of 12 patients as follows; G-I received 20ml of 1% lidocaine epidurally, G-II received 20ml of 1% lidocaine epidurally and 0.6mg BPN intravenously, G-III received 20ml of 1% lidocaine with 0.6mg BPN epidurally. Additional 5ml of 1% lidocaine was given to any patient if systolic blood pressure or heart rate increased 10% compared to control value. Trachea was intubated following anesthetic induction with thiopental. The lungs were ventilated with a mixture of N2O/O2 (33%) and pancuronium was used for muscle relaxation. The total required doses of lidocaine in G-II and G-III were decreased 60% compared to control group (G-I) (P 0.05). The mean period of time until the first administration of pentazocine for postoperative pain was 13 ± 10hr (mean ± SD) in G-II and 19 ± 24hr in G-III compared to 5 ± 4hr in G-I (P 0.001). The dose of the administration of pentazocine that was required for pain relief during the first 48 postoperative hr in G-III was 54 ± 10mg (mean ± SD) compared to 150 ± 21mg in G-I (P 0.02) and 106 ± 28mg in G-II (P 0.05). Recovery from anesthesia in G-III was more rapid than that in G-I (P 0.05). The PaCO 2 values in G-II and G-III increased 15% compared to control group at about 4hr and 8hr after administration of BPN, but any clinical treatment was not needed for them. Nonrespiratory side effects, e.g., nausea, vomiting, fatigue and headache, were comparably common in all groups. Mild hematuria associated with acute hypotension occurred in two patients in G-II (17%) immediately after the intravenous injection of 0.6mg of BPN. The results showed that 0.6mg of BPN given epidurally demonstrated better anesthetic and more potent postoperative analgesic effects and lesser side effects than 0.6mg of BPN given intravenously in patients undergoing upper abdominal surgery.(Yonemura E, Fukushima K.: Comparison of anesthetic effects of epidural and intravenous administration of buprenorphine during operation. J Anesth 4: 242–248, 1990)  相似文献   

2.
In-hospital outcomes associated with abdominal aortic aneurysm (AAA) repair are well described. However, little is known about post-discharge readmission rates, lengths of stay, associated mortality, and costs. We examined 206 consecutive patients who underwent AAA repair at two American hospitals between 1998 and 2000. Index hospitalization and 6-month readmission data were extracted from a resource and cost accounting system used by both hospitals. Among the 206 patients, 183 survived until discharge (mortality rate 11.2%). Among the surviving patients, 38 (21.0%) were readmitted within 6 months. Half of the readmissions occurred within two weeks of discharge, with patients presenting with a diverse array of complications. Nonelective repair and diabetes mellitus were independent predictors of hospital readmission (OR=2.83, 95% CI=1.25-6.40, p=0.01; OR=6.60, 95% CI=1.02-42.4, p=0.047, respectively). For each readmission, the mean length of stay was 10.7±2.5 days and the mean cost was $13,397±3,381. The cumulative number of hospital days during the 6 months post-discharge was 17.7±3.5 days for each readmitted patient and the mean per-patient total cost was $23,262±5,478. The mortality rate among readmitted patients was 13.2%. Overall, readmissions following AAA repair accounted for a cost >50% over and above the cost of the readmitted patients index hospitalization. Hospital readmissions are common during the 6 months following AAA repair. Patients who are readmitted experience long lengths of stay and high mortality rates, and their care incurs high costs.Dr. Eisenberg is a Physician-Scientist of the Quebec Foundation for Health Research. Dr. Pilote is a Physician-Scientist of the Canadian Institutes for Health Research.  相似文献   

3.
Summary. Background. Brain tissue oxygen pressure (PbtO2) correlates to cerebral blood flow (CBF) during spontaneous circulation, with one important regulator being nitric oxide (NO). Although it is established that arginine vasopressin (AVP) improves CBF and global cerebral oxygenation during cardiopulmonary resuscitation, it is unknown whether similar beneficial effects are present during spontaneous circulation. The purpose of this study was to investigate the effects of AVP with and without pre-treatment with the NO synthase inhibitor N-omega-nitro-L-arginine methyl ester (L-NAME) on local brain tissue oxygenation in a beating heart model.Methods. Following approval of the Animal Investigational Committee, nine healthy piglets underwent general anaesthesia, and were instrumented with a probe in the cerebral cortex to measure PbtO2. Each animal was assigned to receive AVP (0.4U·kg–1), and after a wash-out period, L-NAME (25mg·kg–1 over 20min) followed by AVP (0.4U·kg–1). After each AVP administration, nitroglycerine (25µg·kg–1 over 1min) as a NO donor was infused to test the vascular reactivity independently from NOS inhibition.Findings. Three minutes after administration of AVP, PbtO2 increased significantly (P<.05; mean±SEM, 31±11 versus 43±14mmHg, +39%), compared with baseline. After pre-treatment with L-NAME, the changes of PbtO2 after AVP were not significant (32±11 versus 28±10, –13%) when compared with the baseline.Conclusion. In this beating heart porcine model, local brain tissue oxygenation was improved after AVP alone, but not after inhibition of NO synthesis with L-NAME.  相似文献   

4.
Summary. Background. In clinical practice, fiberberoptic and piezo-electric ICP probes are often used for measuring intracranial pressure (ICP). A number of similar technologies, although performing well in bench test studies, have been shown to exhibit unacceptable zero drift, fragility or both during trials conducted under clinical conditions. Recently, a new technology has become available, the Neurovent-P (Raumedic AG+CO, Raumedic, Germany). As a pre-requisite for a clinical trial, we have conducted and report on bench test studies to confirm the manufacturers long term zero-drift performance for this technology.Method. In a test rig static tests (recording of 20mmHg pressure) and dynamic tests, ranging from 5 to 50mmHg have been performed.Findings. 10 ICP probes have been tested for a total of 60 days. All the catheters, after the connection with the ICU monitor displayed a static pressure of 0±1mmHg and did not required pre-insertion alteration. At five days, mean zero drift was 0.6±0.9mmHg. Overall, zero drift ranged from 0 to 2mmHg. At a fixed static pressure of 20mmHg, the mean recorded value was 20.6±0.8mmHg, ranging from 19 to 23mmHg. A regression analysis of the relationship between the applied pressure and the recorded pressure during the dynamic tests of the 10 catheters yielded a correlation coefficient R2 of 0.997. Applying the Altman and Bland method to assess the bias and confidence limits for the Raumedic catheter responses during the dynamic tests against the applied gold-standard hydrostatic column pressures, the average bias of –0.66±0.85mmHg, with 95% CLs of –2mmHg and 1mmHg.Conclusions. Mean zero drift, after five days, was very small and long-term continuous recording of a stable pressure was very precise. The response at dynamic tests, i.e. the changes of pressure in a wide range, was excellent. The average bias of the Raumedic catheter compared with the hydrostatic column is very small. After this bench test, the next and most critical step will be to conduct a trial of this promising technology under more demanding clinical environment.  相似文献   

5.
Combined effects of inversed ratio ventilation (IRV) with positive end-expiratory pressure (PEEP) on cardiorespiratory function were examined in 24 patients with acute respiratory failure. Patients were divided into two groups: the IRV group (n = 12) who showed no significant increase in PaO 2 with a 6cmH2O of PEEP and PEEP group (n = 12) who were ventilated mechanically with PEEP only at maximum level of 10cmH2O. In IRV group step-wise prolongation of the I:E ratio from 1:1.9 to 2.6:1 or 4:1 was applied as a PaO 2 was improved and in PEEP group also level of PEEP was increased from 0, 5 to 10cmH2O after one hour period irrespective of PaO 2. Inversed ratio ventilation and PEEP increased significantly PaO 2/Fi O 2, the increase being observed 6hrs (I:E = 2:1) and 2hrs (10cmH2O) after starting IRV or PEEP. Further improvement of oxygenation was not observed in IRV even if I:E ratio was prolonged up to 2.6:1 or 4:1. These results suggested that combinations of IRV with PEEP were effective and an I:E ratio of 2:1 may be optimal, and IRV is advantageous compared to PEEP, but will take more long time to improve oxygenation than PEEP.(Sari A, Toriumi T, Yamashita S, et al.: Combined effects of inversed ratio ventilation (IRV) with positive end-expiratory pressure ventilation (PEEP) on cardiorespiratory function in acute respiratory failure. J Anesth 5: 105–113, 1991)  相似文献   

6.
Success after endovascular abdominal aortic aneurysm repair (EVAR) is dependent on device positional stability. The quest for such stability has motivated different endograft designs, and the risk factors entailed remain the subject of debate. This study aims at defining the incidence, risk factors, and clinical implications of device migration after EVAR with the AneuRx® endograft. In this study we included all consecutive 109 patients submitted to primary AneuRx placement for infrarenal aortic or aortoiliac aneurysms. Preoperative computed tomography (CT) scans were reviewed for the following anatomic characteristics: neck length, diameter, angulation, calcification, and thrombus load; and sac diameter and thrombus load. Percentage of device oversizing relative to the proximal neck diameter was determined. All postoperative CT scans were reviewed, and the distance between the lowest renal artery and the craniad end of the device was measured. A 5-mm increase in such distance was considered indicative of device migration. Migration cumulative incidence was estimated by the Kaplan-Meier method, and its association with any of the preoperative anatomical characteristics was tested using Cox proportional hazards models. Median follow-up time was 9 (range, 1-31) months. Migration occurred in nine patients, corresponding to a 15.6% estimated probability of migration at 30 months (SE=5.1%). Migration was associated with the risk of proximal type I endoleak (hazard ratio=3.39, 95% confidence interval=1.46-7.87; p=0.007). This type of endoleak occurred in three of the migration-affected patients (33.3%); all of them were resolved by additional cuff placement at the proximal landing zone. No other migration-related reinterventions were performed. The only significant associations between anatomic factors and device migration probability were the protective effects of longer necks (odds ratio [OR]=0.71 for each additional 5 mm, p=0.045) and longer overlapped portions of neck and device (OR=0.56 for each additional 5 mm, p=0.003). There was a trend toward higher probability of migration among reverse-tapered necks (OR=1.75, p=0.109). Percentage of device oversizing correlated with early neck dilation (between preoperative and first postoperative diameters, correlation coefficient=0.4, p < 0.0001), but not with late neck dilatation (between first postoperative and 1.5-year scan diameters, correlation coefficient=0.29, p=0.112). There was a trend toward higher mean percentage of late dilation among migrators (11.4%, standard error of the mean [SEM] 2.6) than nonmigrators (5.7%, SEM=1) (p=0.08), but both groups had similar mean percentages of early dilation (3%, SEM=1.6%, vs. 5.5%, SEM=0.6%; p=0.365). This result indicates that device migration is not a rare event after AneuRx implantation. This phenomenon is associated with proximal type I endoleaks. Deployment of the endograft immediately below the renal arteries might help to prevent migration, since use of greater lengths of overlapped device relative to the proximal neck has a protective effect. Migration seems to be independent of the degree of device oversizing.Presented at the 29th Annual Meeting of the Peripheral Vascular Surgery Society, Anaheim, CA, June 4-5, Sergio M. Sampaio is a recipient of the Edward S. Rogers Clinical Research Fellowship in Vascular Surgery.  相似文献   

7.
In this study, we evaluated the effect of therapeutic doses of cilostazol on human venous smooth muscle. Saphenous vein rings (two to four per patient sample) were suspended in tissue baths for isometric tension recordings. At the beginning of the experiment, optimal tension for isometric contraction was achieved for each ring in a stepwise fashion in the presence of norepinephrine (10–2 M). Norepinepherine was then added cumulatively in half-molar increments and isometric tension developed by the rings was measured, thereby obtaining a dose-response curve. Following washout and reequilibration, the rings were precontracted with a 30-50% submaximal dose of norepinepherine determined from the dose-response curve and allowed to contract until a stable plateau was reached. Cilostazol was then added in a cumulative manner (680-2,720 g/L), and the tension generated was recorded. A total of 76 venous rings were tested, and all relaxed in the presence of cilostazol. The amount of relaxation increased as the concentration of cilostazol increased. Relaxation of 15±1.9% (mean±SEM) at low cilostazol doses (680 g/L) to 37±3% at high cilostazol doses (2,720 g/L) was demonstrated. A second finding of this study was demonstrated when the patient samples were divided according to the presence or absence of risk factors for arteriosclerosis. The specific risk factors examined included diabetes mellitus, smoking, hypercholesterolemia, and hypertension. The presence or absence of hypertension (n=52) or hypercholesterolemia (n=18) did not affect the amount of relaxation of the venous rings. Smokers (n=46) had less relaxation 16±2.4% (680 g/L) to 41±3.6% (2,720 g/L) compared to nonsmokers (n=53) who relaxed 22±3.5% (680 g/L) to 48±5.7% (2720 g/L). This did not reach statistical significance at any concentration cilostazol (p=0.11-0.18). Diabetics (n=53) did have statistically significantly less relaxation at every concentration of cilostazol compared to nondiabetics (n=11, p < 0.05). All venous rings relaxed in the presence of cilostazol. Veins of nondiabetics relaxed statistically significantly more than those of diabetics. Smokers had less relaxation than non-smokers, but this was not statistically significant. We are the first to demonstrate that human venous smooth muscle cells undergo relaxation when exposed to therapeutic concentrations of cilostazol.  相似文献   

8.
Purpose.Aconiti tuber has been used in traditional Oriental medicine to alleviate pain. The antinociceptive property of aconiti tuber is due to the action of its extracted alkaloids such as deoxyaconitine. The purpose of this study was to investigate the effect of epidural deoxyaconitine on epidural lidocaine anesthesia. Methods.Five adult rabbits were used. Three different combinations of drugs were injected into the epidural space, in the following order: first (combination A), 1.5ml of 2% lidocaine; second (combination B), 1.5ml of 2% lidocaine and 150µg deoxyaconitine; and third (combination C), 3mg nor-binaltorphimine followed by 1.5ml of 2% lidocaine and 150µg deoxyaconitine 30min later. The latency of onset and the duration of three end-points (sensory loss in the tail, loss of weight-bearing ability, and flaccid paresis of hind limb) were measured. Results.Onset times for the three end-points were not changed by deoxyaconitine or by nor-binaltorphimine. The duration of sensory loss was 27.0 ± 2.7min, the duration of loss of weight-bearing ability was 33.0 ± 2.7min, and the duration of flaccid paresis was 21.0 ± 4.2min in the combination A group. In the combination B group, deoxyaconitine extended the time of sensory loss by 80%, the time of loss of weight-bearing by 50%, and that of flaccid paresis by 60% compared with the combination A group. In the combination C group, this phenomenon was partially antagonized by pretreatment with nor-binaltorphimine, a -opioid antagonist. Conclusions.Based on our observations, deoxyaconitine enhanced epidural lidocaine anesthesia in the rabbit, and this effect seemed to be partly mediated by -opioid receptors.  相似文献   

9.
Purpose We investigated the effective and safe dose of intravenous midazolam for sedation and amnesia during spinal anesthesia in patients premedicated with intramuscular midazolam.Methods One hundred and eighty patients aged 20–50 years scheduled for spinal anesthesia received midazolam 0.06mg·kg–1 and atropine 0.01mg·kg–1 intramuscularly 15min before entering the operating room. Spinal anesthesia was performed with 0.5% hyperbaric tetracaine. Five minutes after starting surgery, midazolam 0 (control group), 0.01, 0.02, 0.03, 0.04, or 0.05mg·kg–1 was intravenously administered (30 patients each). Blood pressure, heart rate, respiratory rate, percutaneous oxygen saturation (Sp O 2), verbal response, eyelash reflex, and involuntary body movement were measured every 5min for 30min. Memory during surgery was also investigated.Results The number of the patients with loss of verbal response, with loss of eyelash reflex, and with no memory during surgery were significantly larger in the groups receiving midazolam 0.03mg·kg–1, 0.04mg·kg–1, and 0.02mg·kg–1, respectively. The decrease in blood pressure or increase in respiratory rate with decrease in Sp O 2 was significantly larger in the groups receiving midazolam 0.03mg·kg–1 or 0.05mg·kg–1, respectively.Conclusion For sedation and amnesia of the patients aged 20–50 years in spinal anesthesia with about 1h duration receiving intramuscular midazolam 0.06mg·kg–1 as a premedication, intravenous midazolam 0.02mg·kg–1 might be effective and safe.  相似文献   

10.
We undertook this study to determine whether the use of contrast venography would adversely affect renal function in patients with renal insufficiency requiring caval interruption. We conducted a retrospective review of all inferior vena cava (IVC) filters inserted at our institution over a 2-year period (January 2002 to January 2004). The indication for caval interruption, insertion technique, type of filter used, pre- and postintervention creatinine level, and the presence of diabetes and hypertension were analyzed. A total of 282 IVC filters were inserted, with 38 of them placed in patients with renal insufficiency as defined by a serum creatinine level of > 1.5 mg/dL. Contrast venography with 15 to 30 mL of iohexol (Omnipaque 300) was used in all cases, and no special measures other than proper hydration were used for renal protection. All filters were successfully deployed. The mean±SD preintervention creatinine level was 2.38±0.79 mg/dL. The mean±SD postintervention creatinine levels at 2 and 30 days were 2.26±0.45 mg/dL and 2.12±0.94 mg/dL, respectively. No patients required hemodialysis following caval interruption, and no adverse effect on renal function was noted. Contrast venography accurately delineates venous anatomy and facilitates proper caval filter placement with no apparent adverse effect on renal function. We believe contrast venography is safe even in the presence of renal insufficiency.  相似文献   

11.
We developed a rotational total hip prosthesis that has a 30mm diameter metal-covered head with a polyethylene liner with which it can rotate around the neck of the stem. Long-term results of the rotational total hip arthroplasty with cement were evaluated in 55 hips of 52 patients. The diagnosis was degenerative osteoarthritis in all patients. The mean follow-up was 11.2 years (range 5–19 years). Eight of thirty 7mm thick acetabular components were revised 7.6–14.3 years (mean 10.4 years) afterward. Two of twenty five 9.5mm thick acetabular components and two femoral components were revised at 12 and 15 years, respectively. The mean polyethylene wear in the 9.5mm thick acetabular components was significantly less than that in the 7mm thick components. The mean polyethylene wear inside the rotational head removed during the revision surgeries was 0.01mm in diameter and 0.03mm in depth per year, respectively. Fifty percent of the patients with 7mm thick acetabular components, 9.5mm thick components, and femoral components had surviving prostheses at 13.4, 15.2, and 16.3 years, respectively. It is possible that the rotational system reduces the stress against acetabular and femoral components, but the 30mm diameter head caused high friction torque and required at least 9.5mm thickness in the acetabular component.  相似文献   

12.
Atherosclerotic renal artery stenosis is a significant cause of poorly controlled hypertension and progressive renal dysfunction leading to ischemic nephropathy and other end-organ damage. The optimal treatment of renovascular disease contributing to hypertension and renal dysfunction is not known. This study compares the anatomic and functional outcomes of both open and endovascular therapy for chronic, symptomatic atherosclerotic renal artery disease. We performed a retrospective analysis of records from patients who underwent renal arterial interventions, endovascular or open bypass, between January 1984 and January 2004. Principal indications for intervention were hypertension (51%), chronic renal insufficiency (13%), and hypertension and elevated creatinine (36%). A total of 247 patients (109 males; mean age 69±10, range 44–89 years) underwent 314 interventions (109 open procedures; 205 angioplasties, 71% with stent placement). There was a significant difference in 30-day mortality (4% vs. <1%; p < 0.005) between the open and endoluminal groups, but not at 1, 3, or 5 years. Patients in the open group had a higher primary patency rate at 5 years (83±5% vs. 76±6%; p=0.03), but patients in the endoluminal group had a higher assisted primary patency rate at 5 years (92±5% vs. 84±5; p=0.03). There was no significant difference between both treatment groups in cumulative freedom from presenting symptom or in freedom from dialysis and renal-related death. Patients who presented with hypertension were more likely to have shown improvement in their blood pressure with endoluminal intervention at 1, 3, and 5 (59±6% endoluminal vs. 83±5% open; p=0.01) years. From these results we conclude that open repair and endoluminal repair of atherosclerotic renal artery stenosis have similar immediate and long-term functional and anatomic outcomes. Patients who present with hypertension may have greater benefit with an endoluminal repair.Presented at the Twenty-ninth Annual Meeting of the Peripheral Vascular Surgery Society, Anaheim, CA, June 4-5, 2004.  相似文献   

13.
Purpose The present study was designed to evaluate the efficacy of a cyclooxygenase (COX)-2 inhibitor, etodolac, on postoperative pain after fast-track cardiac surgery, and to examine the changes in plasma etodolac concentration after oral administration.Methods Thirty patients scheduled for elective coronary artery bypass grafting (CABG) surgery were randomly assigned preoperatively in a double-blind fashion to receive either vehicle (n = 15) or etodolac 400mg (n = 15) via a gastric tube at the end of the surgery. Standardized fast-track cardiac anesthesia was used. In both groups, postoperative pain was treated with buprenorphine suppository. Visual analogue pain scores (VASs) were recorded immediately after extubation and at 24h after surgery. Plasma etodolac concentration was measured at 1, 2, and 6h after administration (n = 8).Results No difference was detected in time to extubation between the etodolac group (209 ± 85min, mean ± SD) and the vehicle group (207 ± 98min). VASs were significantly lower in the etodolac (2.3 ± 2.1) vs the vehicle group (5.8 ± 2.0) immediately after extubation (P = 0.009), but no difference was detected in pain scores at 24h after surgery, or in the amount of buprenorphine administered in the intensive care unit (ICU), or in the incidence of side effects. Plasma etodolac concentration was within the pharmaceutically recommended range at 1h, 2h, and 6h after administration.Conclusion The oral use of etodolac with rectal buprenorphine reduces pain scores immediately after cardiac surgery without an increase in side effects.  相似文献   

14.
We examined the effects of enflurane on the diaphragmatic function in 15 pentobarbital-anesthetized, mechanically ventilated dogs. They were divided into three groups of five animals each, according to the administered concentration of enflurane. The diaphragmatic function was assessed from transdiaphragmatic pressure (Pdi) and integrated diaphragmatic electromyography (Edi) developed at functional residual capacity against an occluded airway during bilateral supramaximal phrenic nerve stimulation at 0.5, 10, 20, 50 and 100Hz under quasiisometric condition. After a control measurement, enflurane was administered at a constant end-expired concentration (0, 0.5 and 1MAC) and the measurement was repeated after 1 hour of exposure. The Pdi amplitude generated by single twitch (0.5Hz) and during 10, 20 and 50Hz stimulation was unchanged between the groups. No change in Pdi during 100Hz stimulation was noted during 0 and 0.5MAC exposure, while it was reduced by 1MAC of enflurane. When the values of Pdi were expressed as % of maximum Pdi (%Pdi,max) that developed during control measurement and analyzed in terms of %Pdi,max—stimulus frequency relationship, a significant decrease in %Pdi,max was noted for 100Hz stimulation in 0.5 and 1MAC groups compared to the control. Similarly, Edi during 100Hz stimulation obtained in 0.5 and 1MAC groups was markedly depressed compared to the control. Edi during 50Hz stimulation was also decreased at 1MAC. Relative changes in Edi following enflurane administration were greater than the corresponding changes of Pdi. These results demonstrate that enflurane impairs diaphragmatic function through its inhibitory effects on neuromuscular transmission.(Kochi T, Ide T, Isono S, et al.: Enflurane supresses phrenic nerve-diaphragm transmission in vivo. J Anesth 5: 260–267, 1991)  相似文献   

15.
Skin erythemas formed in three patients during surgery at the sites where negative electrodes had been attached to stimulate the ulnar nerve for a neuromuscular transmission monitor (Relaxograph). The patients were all women, aged 52, 62, and 74 years, and general anesthesia lasted 8h 20min, 4h 50min, and 8h 45min, respectively. The electrodes used were disposable ECG electrodes in the first two patients and one designed for a neuromuscular monitor in the third; all were carbon-coated and then covered with gel. However, when the electrodes were detached from the lesion, they all showed loss or damage of the carbon coating under the gel. We recommend balancing the merit of monitoring with the risk of complications, even when applying an apparently safe, noninvasive monitor.  相似文献   

16.
The effect of craniotomy location on postoperative pain and nausea   总被引:1,自引:0,他引:1  
Purpose.At least one retrospective study has suggested that the need for postoperative control of pain and nausea depends on the location of the cranial surgery. This prospective study was performed to examine the hypothesis that patients who have had infratentorial craniotomy experience more severe pain and more frequent nausea than those with supratentorial procedures. Methods.We compared postoperative outcomes in 28 patients with infratentorial craniotomy, 53 with supratentorial craniotomy, and 47 with complex spinal cord surgery (the control group). Anesthesia was standardized for all three groups and the concentration of isoflurane was titrated to keep mean arterial pressure within 30% of preoperative values. Severity of pain and frequency of nausea and vomiting were recorded for 24h after surgery. Pain was assessed with a verbal pain score scale of 0–10, with 10 being the worst pain imaginable. Data were collected for 24h postoperatively. Results.Because nausea and pain diminish drastically 2h after surgery, pairwise differences were assessed at each point within the first 2h. Within 30min of extubation, median pain scores in the supratentorial and spine groups rose to 2 and in the infratentorial group to 5. The statistical differences between groups were not significant (P > 0.06) by logistic regression. Also, the incidence of nausea was not significantly different (57% supratentorial, 57% spine, 67% infratentorial; P = 0.62) by Dunns procedure. Conclusion.There were no significant differences in the severity of pain or the frequency of nausea based on the craniotomy site.  相似文献   

17.
The relationship between the age and the spread of analgesia from different epidural anesthetic doses was examined by studying analgesic dose responses in cervical epidural analgesia. Two different anesthetic doses (5ml or 10ml) of 2% mepivacaine were injected into the cervical epidural space at a constant pressure (80mmHg) using an intravenous apparatus, and the spread of analgesia to pinprick was assessed. The significant correlation was found between the patients age and the number of spinal segments blocked (5ml:r = 0.8498, P < 0.01, 10ml:r = 0.5988, P < 0.01). The inverse linear relationship was found between the patients age and the segmental dose requirement (5ml:r = –0.6754, P < 0.01, 10ml:r = –0.5784, P < 0.01). Patients under 39 years of age showed a direct relationship between the dose injected and the number of spinal segments blocked, enabling prediction of the number of segments blocked with a given dose of local anesthetic. Doubling the epidural dose approximately doubled the number of spinal segments blocked. The analgesic dose-response relation in patients over 60 years of age differed from that in patients under 39 years of age and doubling the epidural dose did not double the number of spinal segments blocked. Progressively more extensive analgesia was obtained from a given dose of local anesthetic with advancing age. It was difficult to limit the extent of analgesia by injecting a smaller dose of local anaesthetic in the elderly.(Hirabayashi Y, Matsuda I, Inoue S et al.: Analgesic dose-response relation in cervical epidural block. J Anesth 2: 22–27, 1988)  相似文献   

18.
A number of studies have highlighted the increasing incidence of aseptic cup loosening with increasing depth of cup penetration by the metal head. We present our experience with a 22.225mm diameter zirconia head on a 9–10 taper articulating with an ultra-high-molecular-weight polyethylene (UHMWPE) cup in cemented total hip arthroplasties. We prospectively studied the wear of the UHMWPE cup articulating with a 22.225mm diameter zirconia head in cemented total hip arthroplasties. A total of 339 patients (153 men, 186 women, 373 hips) were included. The patients mean age at surgery was 52 years (17–76 years), with 41% age 50 years or younger. Their mean weight was 72.4kg (24–125kg). At a mean follow-up of 4.3 years (0–8 years) the mean penetration rate of the cup was 0.03mm/year (0–0.51mm/year). Altogether, 289 (77.5%) showed no measurable wear, 38 (10.2%) had a penetration rate of 0.11mm/year or less, 33 (8.9%) had a rate of 0.12–0.2mm/year, and in 13 (3.5%) the rate was more than 0.2mm/year. Ceramic–UHMWPE is the next stage in the evolution of total hip arthroplasty for addressing wear and any possible related issues.  相似文献   

19.
The authors have established a new method for extraction and determination of atracurium in human plasma that employs a reversed phase high-performance liquid chromatography (HPLC). This method made use of a fluorescent spectrophotometer at an excitation wavelength of 240nm and an emission wavelength of 310nm. The mobile phase was made of a phosphate buffer, distilled water and acetonitrile (20V:30V:50V). The analytical column used was a Little Champ C18.In a Bond Elute C18 extraction column, which had been prewashed with a phosphate buffer and a 50% methanol solution, atracurium was extracted from acidified plasma samples using a mixture of methanol and phosphate buffer. A standard curve was prepared by the internal standard method using metocurine. A high linear correlation between atracurium concentration and the ratio of the atracurium peak height to the metocurine peak height was observed (r = 0.9994). The lowest threshold for detection of atracurium was 15ng/ml. When the plasma concentrations of atracurium were determined in 2 clinical cases, t1/2 was 2.10 and 1.73min and t1/2 was 15.57 and 21.57min, respectively. These results indicate that this method of extraction and determination is appropriate for studying the pharmacokinetics of atracurium because it allows a high reproducibility, and provides an extremely accurate, simple and quick analysis.(Okutani R, Kono K, Frederic M. deBros et al.: Quantitative determination of atracurium in human plasma using high-performance liquid chromatography. J Anesth 2: –, 1988)  相似文献   

20.
The effects of calcium and temperature on the tension of isolated canine coronary arterial strips were studied.In 20mEq·l –1 K solution, the tension was significantly increased from 0mg with 0mEq·l –1 Ca to 33 ± 18mg with 0.2mEq·l –1 Ca at 37°C, from –40 ± 18mg with 0mEq·l –1 Ca to –17 ± 11mg with 0.2mEq·l –1 Ca at 30°C, from –77 ± 19mg with 0mEq·l –1 Ca to –52 ± 17mEq·l –1 with 1mEq·l –1 Ca at 25°C, from –88 ± 13mg with 0mEq·l –1 Ca to –41 ± 18mg with 2mEq·l –1 Ca at 20°C, from –125 ± 16mg with 0mEq·l –1 Ca to –116 ± 13mg with 2mEq·l –1 Ca at 15°C. Ca higher than 0.2mEq·l –1 produced a dose-dependent increase in tension between 37°C and 15°C. In spite of the presence of 4mEq·l –1 Ca, the development of tension was strongly supressed by lowering the temperature below 20°C, and completely inhibited at 10°C. The rate of a decrease in tension caused by cooling was about 5.5mg·°C–1.This study demonstrated that Ca2+ produced a dose-dependent increase in tension in high-K solution, which was suppressed as the temperature was lowered.(Yoshida K, Fujii Y, Ina H, et al.: Effects of calcium and temperature on tension in isolated canine coronary artery. J Anesth 5: 172–176, 1991)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏