首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Full‐arch screw‐retained implant‐supported fixed dental prostheses have a high long‐term success rate and are considered the gold standard by many clinicians. However, accurate fabrication of a passive fit long‐span prosthesis can be challenging. A novel intraoral adhesion method using galvano‐telescopic copings was proposed as a way of improving prosthetic fit for edentulous patients. This report describes the treatment of a 74‐year‐old female with a full‐arch implant‐supported dental prosthesis, supported by a combination of galvano‐telescopic copings and screws to prevent retention loss. Four years have passed since this superstructure was placed, during this time she exhibited a good clinical course with no inflammation noted in surrounding tissues. Treatment with an implant‐supported fixed dental prosthesis, retained by a combination of galvano‐telescopic copings and screws, can be a useful alternative treatment for edentulous patients.  相似文献   

2.
The present retrospective case series is aimed at evaluating a staged approach using a removable partial denture (RPD) as an interim prosthesis in treatment to correct a failing dentition until such time as a full‐arch fixed implant‐supported prosthesis may be inserted. Eight patients, who had undergone maxillary full‐arch rehabilitation with dental implants due to poor prognosis of their dentitions, were analyzed. All treatment included initial periodontal therapy and a strategic order of extraction of hopeless teeth. An RPD supported by selected teeth rehabilitated the compromised arch during implant osseointegration. These remaining teeth were extracted prior to definitive prosthesis delivery. Advantages and drawbacks of this technique were also recorded for the cases presented. Among the advantages provided by the staged approach are simplicity of fabrication, low cost, and ease of insertion. Additionally, RPD tooth support prevented contact between the interim prosthesis and healing abutments, promoting implant osseointegration. The main drawbacks were interference with speech and limited esthetic results. Implant survival rate was 100% within a follow‐up of at least 1 year. The use of RPDs as interim prostheses allowed for the accomplishment of the analyzed rehabilitation treatments. It is a simple treatment alternative for patients with a low smile line.  相似文献   

3.
This clinical report presents the clinical outcome of a maxillary full‐arch implant‐supported fixed rehabilitation with lithium disilicate reinforced glass ceramic monolithic crowns opposing a mandibular metal‐acrylic implant‐supported fixed rehabilitation in a 62‐year‐old woman. Eight implants were successfully placed (four maxillary, four mandibular), and no complications occurred in the postoperative or maintenance periods. Six months after delivery, the maxillary and mandibular prostheses were found to be clinically, biologically, and mechanically stable, and the patient was satisfied with the esthetics and her ability to function. Although the present indications for the use of lithium disilicate are still restricted to tooth‐borne restorations, it is possible to successfully rehabilitate edentulous patients through implant‐supported fixed prostheses using lithium disilicate reinforced glass ceramic monolithic crowns.  相似文献   

4.
Background: Long‐term follow‐up studies (i.e., over 5 years), focusing on prosthetic outcomes and maintenance of implant‐supported reconstructions in the edentulous maxilla, are scarce in the literature. Purpose: The purpose of this study was to evaluate and report 10‐year data on outcomes and maintenance of screw‐retained implant‐supported full‐arch casted titanium‐resin prostheses in the edentulous maxilla. Materials and Methods: In the randomized control trial cohort of 24 patients, the outcome and maintenance of 23 bridges were registered. Results: One patient dropped out of the study prior to the 10‐year control. Of the 23 remaining patients, 21 still had their original frameworks; one framework fractured after 8 years and one was remade after 7 years to create better support for the acrylic. The remaining 23 prostheses showed criteria of success, survival, and failure in 9, 82, and 9%, respectively. Tightening of two assembly screws was necessary in one patient. No detrimental effects were seen because of long cantilever extensions or opposing dentition. A total of 4.7 resin‐related complications per prosthesis were observed; tooth fracture was the most common prosthetic complication. There was an indication of greater prevention in the number of resin‐related complications with the use of lingual gold onlay compared with a resilient mouth guard, 0.71 and 1.67, respectively per bridge. The bridges were removed and reinserted 0.83 times per patient. No abutment or abutment screw fractures were registered. Conclusion: Fracture or wear of the reconstruction materials were considered predictable risks when using resin‐based suprastructure materials. Status of opposing dentition and length of cantilevers did not confer additional risk. The use of a lingual gold onlay indicated prevention of resin‐related complications. Future research should focus on the suprastructure materials to predict better overall treatment results of implant‐supported full‐arch bridges in the edentulous maxilla.  相似文献   

5.
Background: No long‐term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. Aim: To evaluate and compare the clinical and radiographic performance of implant‐supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold‐alloy frameworks during the first 10 years of function. Material and Methods: Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold‐alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10‐year data were collected for the groups and statistically compared on patient level. Results: The 10‐year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow‐up. Smokers lost more implants than nonsmokers after 5 years of follow‐up (p < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group (p > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p < .001). Conclusion: The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC‐milled titanium frameworks are a viable alternative to gold‐alloy castings for restoring patients with implant‐supported prostheses in the edentulous jaw.  相似文献   

6.
The fabrication of an implant‐supported fixed complete denture prosthesis involves multiple clinical and laboratory steps. One of the main steps is to provide the patient with an interim fixed prosthesis to evaluate the patient's esthetic and functional needs as well as to enhance the patient's psychology before proceeding to the definitive prosthesis. Different techniques for fabricating interim prostheses have been described in the literature. This report describes an alternative technique that uses a duplicate denture made of self‐curing acrylic resin to fabricate an implant‐supported fixed interim prosthesis. The interim prosthesis was later used as a blueprint for the definitive implant‐supported hybrid prosthesis.  相似文献   

7.
Despite advancements in restorative materials and techniques, complications with implant‐supported fixed prostheses such as veneer fracture and material wear are very common and present with varying frequencies. Following these complications, repair of this type of prosthesis can be time‐consuming and costly even in the hand of experience clinicians. Several techniques have proposed using the existing framework to minimize the cost of the repair for the patient; however, while the repairs are being performed, the patient will have to either wear an interim complete denture or no prosthesis, which might cause some inconvenience to the patient. This article will present a technique for the fabrication of a metal‐reinforced interim implant‐supported fixed prosthesis for patients to wear while the existing prosthesis is being repaired.  相似文献   

8.
Purpose: The purpose of this clinical follow‐up was to document the 7‐year outcome of immediately loaded implants exhibiting an oxidized surface. Material and Methods: Thirty‐eight patients received a total of 51 implant‐supported fixed prostheses. The restorations were supported by 102 implants, the majority of which were placed in posterior regions (88%) and primarily in soft bone quality (76%). Radiographic examinations were performed at prosthesis insertion, at 1‐ and 6‐month follow‐ups, and annually at the 1‐ through 5‐year follow‐up visits. Marginal peri‐implant soft tissue evaluations were conducted at all these follow‐ups. This report presents the results after at least 7 years of loading. Results: After 7 years of prosthetic loading, the cumulative implant survival rate was 97.1% and the mean marginal bone remodeling was ?1.51 mm (SD 1.00, n = 73) with significantly more initial remodeling at sites having received marginal guided bone regeneration procedures. A low rate of biological and technical complications was detected after 7 years of function. The quantification of intrasulcular plaque sampling showed no significant difference between teeth and implants. Conclusion: The 7‐year follow‐up data indicate that the introduced immediate loading protocol is a successful treatment alternative also including regions exhibiting soft bone conditions.  相似文献   

9.
Full‐arch, fixed, implant‐supported prostheses can be designed to be cement‐ or screw‐retained. Both retention mechanisms have a few inherent disadvantages. A fixed attachment system has been introduced to circumvent the disadvantages of both screw and cement retention. This system eliminates the screw access holes and the use of cement. The number of intraoral procedures required is also reduced. The purpose of this article is to report a case using the Locator F‐Tx Attachment System to facilitate fabrication of an esthetic, clinician‐retrievable, full‐arch implant‐supported fixed dental prosthesis.  相似文献   

10.
Fracture and loosening of implant‐supported prostheses (ISPs) are complications encountered in routine dental practice. In the present report, management of a fractured maxillary full‐arch cement‐retained (CR) fixed dental prosthesis supported by six implants is presented. Due to stripped screws, complications were encountered that prevented the retrieval of two of the six abutment screws, which was managed by using a hybrid retention approach, whereby a single full‐arch CR and screw‐retained (SR) ISP was used. The techniques used to successfully retrieve four of the abutment screws are described. The final retention design involved a combination of three CR and three SR restorations, which offers the advantages of both retention designs.  相似文献   

11.
Purpose: The aim of this prospective study was to assess long‐term clinical outcomes and peri‐implant bone level changes around oxidized implants supporting partial fixed rehabilitations. Materials and Methods: Twenty‐two partially edentulous patients were included in the study. A total of 33 fixed rehabilitations were placed, supported by 54 titanium implants with oxidized microtextured surface. Prostheses were delivered after 3 and 6 months of implant placement in the mandible and maxilla, respectively. Patients were scheduled for follow‐up at 6 and 12 months and then yearly. At each follow‐up, plaque level and bleeding scores were assessed and periapical radiographs were taken. The main outcomes were prosthesis success, implant survival, implant success, and marginal bone level change. Results: Three patients were excluded from the study because they did not attend the 1‐year follow‐up. Nineteen patients, accounting for 49 implants, were followed for at least 6 years after prosthesis delivery. The mean follow‐up duration was 81.8 months (range 75–96 months). One mandibular single‐tooth implant failed after 1 year in a smoker woman. Cumulative implant survival and success at 6 years were 98.0% and 95.9%, respectively. Prosthesis success was 96.7%. The mean peri‐implant bone loss at 6 years was 0.76 ± 0.47 mm. Not significantly (p = .75) greater bone loss was found in the maxilla (0.78 ± 0.14 mm, n = 19) as compared with the mandible (0.74 ± 0.59 mm, n = 30). In the maxilla, bone loss was significantly greater around implants supporting partial prostheses as compared with single‐tooth implants (p = .03). Full patient satisfaction was reported. Conclusion: Implants with oxidized microtextured surface may achieve excellent long‐term clinical outcomes in the rehabilitation of partial edentulism.  相似文献   

12.

1 Background

Computer‐guided systems were developed to facilitate implant placement at optimal positions in relation to the future prosthesis. However, the time, cost and, technique sensitivity involved with computer‐guided surgery impedes its routine practice. The aim of this study is to evaluate survival rates and complications associated with computer‐guided versus conventional implant placement in implant‐retained hybrid prostheses. Furthermore, long‐term economic efficiency of this approach was assessed.

2 Methods

Patients were stratified according to implant placement protocol into a test group, using computer‐guided placement, and a control group, using traditional placement. Calibrated radiographs were used to measure bone loss around implants. Furthermore, the costs of the initial treatment and prosthetic complications, if any, were standardized and analyzed.

3 Results

Forty‐five patients (149 implants in the test group and 111 implants in the control group) with a minimum follow‐up of 5 years, and a mean follow‐up of 9.6 years, were included in the study. While no significant difference was found between both groups in terms of biologic and technical complications, lower incidence of implant loss was observed in the test group (< 0.001). A statistically significant difference in favor of the non‐guided implant placement group was found for the initial cost (< 0.05) but not for the prosthetic complications and total cost (> 0.05).

4 Conclusions

Computer‐guided implant placement for an implant‐supported hybrid prosthesis is a valid, reliable alternative to the traditional approach for implant placement and immediate loading. Computer‐guided implant placement showed higher implant survival rates and comparable long‐term cost to non‐guided implant placement.  相似文献   

13.
The primary objectives of successful prosthetic rehabilitation are to provide function, esthetics and comfort to the patient. Combination prosthesis is one which is supported by both natural teeth and implant. The periodontal ligament and osseointegrated interface distribute force differently to the supporting bone. Therefore problems can develop when tooth and implants are combined in the same prosthesis. However, clinicians can apply biomechanical principles, to negate the deleterious leverages exerted by the fixed prosthesis by using non rigid components and to equalize the stress applied by the prosthesis on implant and teeth. A case of partially edentulous situation was rehabilitated successfully with a combination of prostheses. Maxillary arch was restored to function with crowns, fixed dental prosthesis and with an extra coronal castable attachment prosthesis and the mandibular arch with a combination of tooth and implant supported attachment prosthesis. The clinical and laboratory steps for the fabrication of these prostheses are explained in this report.  相似文献   

14.
The most important objectives in restoring the maxillofacial patient are the restoration of function and psychological improvement through esthetics. Acquired maxillary and mandibular defects due to significant trauma or surgery represent a major challenge for the clinician and patient. Dental implant‐retained prostheses represent a well‐documented and reliable treatment option and can also help patients with maxillofacial defects by eliminating denture instability and improving function. Full‐arch fixed dental hybrid prostheses provide functional and psychological advantages and also reduce the load on vulnerable soft and hard tissues in the reconstruction area. Two clinical reports are presented describing the prosthetic rehabilitation using dental implant‐supported fixed hybrid prostheses with clinical and radiographic follow‐up of 3 years.  相似文献   

15.
Objectives: To compare the electromyographic (EMG) characteristics of masticatory and neck muscles in patients with natural dentition, teeth‐supported prostheses and implant‐supported prostheses. Materials and methods: Twenty‐five subjects aged 40–80 years were examined. Five patients had maxillary and mandibular implant‐supported fixed prostheses; five patients had mandibular implant‐supported fixed prosthesis and maxillary removable complete denture; seven patients had implant‐supported fixed prosthesis (one arch) and natural dentition or full‐arch tooth‐fixed prosthesis (one arch); and eight control subjects had natural dentition or single tooth‐fixed prostheses. Surface EMG of masseter, temporal and sternocleidomastoid muscles was performed during maximum teeth clenching and unilateral gum chewing. Interarch dental contacts were assessed with shim stocks. Results: All groups had similar interarch dental contacts (P>0.05). During clenching, patients with maxillary and mandibular implant‐supported fixed prostheses had unbalanced standardized masseter and temporalis anterior activities (74%), with significantly larger values found in the other patients and control subjects (all mean values larger than 86%, P=0.017). All patients chewed with significantly larger muscular potentials than control subjects (on average, 1434–2100 μV s vs. 980 μV s, P=0.04), and had altered muscular patterns (left side, P=0.021). The patients with one arch with natural dentition/tooth fixed prostheses had chewing muscular patterns similar to the control subjects. Conclusions: Clenching with the analyzed prostheses was performed with a relative increment of temporalis activity. Neuromuscular coordination during chewing was larger in patients who maintained their teeth or dental roots, independently from the number of dental contacts.  相似文献   

16.
Background: Few long‐term follow‐up studies are available on implant treatment based on patient level data related to time. Purpose The aim of this study was to report 15‐year patient‐based data in relation to time of follow up after treatment with fixed prostheses supported by implants in the edentulous upper jaw. Materials and Methods Seventy‐six edentulous consecutive patients, provided with 450 turned Brånemark implants, were followed up with regard to maintenance, complications, and radiographs taken during the follow‐up period. Results Forty‐four patients provided with 247 implants were lost to follow up. Patients followed up for 15 years showed as a group a trend of better implant survival than patients lost to follow up (p > .05). Altogether, 37 implants and 5 fixed prostheses failed during the follow‐up period. Most implants were lost at abutment surgery (n? 15) and another nine during the first year of function. The 15‐year implant and fixed prosthesis cumulative survival rate was 90.9 and 90.6%, respectively. Resin veneer fractures caused most problems, more frequent in the earlier stage while severe wear increased in the later stage of follow up. No implant fractures or loosening of abutment/bridge locking screws were noted. The mean marginal bone loss was 0.5 mm (SD 0.47) after 5 years, followed by only minimal average changes during the following years. No radiographic parameter showed any time‐dependent relationship. The percentage of patients presenting at least one implant with more than 2.0‐mm bone loss was 4.9% in the interval from 0 to 5 years and 4.0% between 10 and 15 years. Only 1.3% of implants showed >3.0 mm accumulated bone loss after 15 years. Conclusion Implant treatment in the edentulous upper jaw functions well in a 15‐year time perspective, but an insignificant trend of higher implant failures was observed for patients lost to follow up. Besides wear and fractures of veneers, no other parameter showed any time‐related relationship, indicating an increased risk for more complications during later stages of follow up. However, accumulation of smaller amount of bone loss during the years resulted in an increasing number of implants and patients with bone levels below the third thread, which could be speculated to increase future maintenance after 15 years.  相似文献   

17.
The rehabilitation of edentulous maxillae is a complex procedure due to the involvement of esthetic and functional requirements. A trial maxillary denture can be used to identify the need for adequate upper lip support when replacing removable complete dentures by implant‐fixed dental prostheses. This clinical report describes the outcome of the rehabilitation of an edentulous atrophic maxilla with unfavorable maxillomandibular relationship and deficient upper lip support. A trial denture was fabricated and used to diagnose the need for a prosthesis capable of restoring the upper lip support. The reduced upper lip support was also confirmed by a lateral cephalogram. The patient was rehabilitated by an implant‐fixed dental prosthesis associated with an attachment‐retained gingival prosthesis. The case presented shows that when loss of upper lip support is detected and the patient does not wish to undergo further surgical reconstruction procedure, the retention of a gingival prosthesis using a ball attachment is a satisfactory treatment option.  相似文献   

18.
For most of the last century, conventional complete dentures have been the standard of care and the most common treatment for edentulous patients. Technological advancements in fabrication techniques may significantly reduce the number of office visits required to fabricate complete dentures. Immediate occlusal loading with mandibular full arch prostheses has been extensively researched and is now one of the standards of care for edentulous patients. A clinical technique for converting a mandibular immediate complete denture to an interim full arch, screw‐retained fixed prosthesis with novel implant restorative components for immediate loading on four implants is described.  相似文献   

19.
Late cluster implant failures can be one of the most devasting outcomes of implant therapy for patients. It can have anatomic, functional, psychological and financial consequences for patients, and sometimes the loss of residual bone can preclude subsequent implant placement. Fortunately, management of cluster implant failures in the maxilla can be mitigated by using implant anchorage from remote sites like zygomatic and pterygoid regions. Few reports exist in the literature that have described the management of cluster implant failure using extra‐maxillary implants such as zygomatic and pterygoid implants. This case report describes the management of a female patient with bruxism who experienced late cluster implant failure in the maxilla after 9 years of function with an overdenture. Due to the loss of residual bone, subsequent implant therapy involved the use of bilateral zygomatic, pterygoid and anterior maxillary implants, which were immediately loaded and thereafter used to support a complete arch fixed implant‐supported zirconia prosthesis.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号