共查询到20条相似文献,搜索用时 15 毫秒
1.
Location,variations, and predictors of epicardial fat mapping using multidetector computed tomography to assist epicardial ventricular tachycardia ablation 下载免费PDF全文
Mariaileen Sourwine MS MD Jean Jeudy MD Brian Miller MD Rama Vunnam MD Hasan Imanli MD Olurotimi Mesubi MD Martine Etienne‐Mesubi MPH DrPH Vincent See MD Stephen Shorofsky MD PhD Timm Dickfeld MD PhD 《Pacing and clinical electrophysiology : PACE》2017,40(10):1059-1066
2.
Yamada T Doppalapudi H McElderry HT Plumb VJ Kay GN 《Pacing and clinical electrophysiology : PACE》2012,35(5):e116-e119
A 55-year-old man underwent catheter ablation of ventricular tachycardia (VT) after anterior myocardial infarction. Although electrophysiological study suggested that the VT originated from the septum, biventricular endocardial irrigated radiofrequency ablation failed to interrupt the VT. Epicardial ablation at the site located halfway between the lesions in the right and left ventricles via a pericardial approach eliminated the VT, suggesting that the VT likely originated from the top of the septum. When VTs originating from the upper septum are refractory to endocardial ablation, epicardial mapping and ablation may be considered because only that site may be accessible with an epicardial approach. 相似文献
3.
Effect of radiofrequency on epicardial myocardium after ablation of ventricular arrhythmias from within coronary sinus 下载免费PDF全文
Basar Candemir MD Elif Ozyurek MD Kutay Vurgun MD Nazli Turan MD Veysel Duzen MD Huseyin Goksuluk MD Nil Ozyuncu MD Seda Kurklu MD Timucin Altin MD Omer Akyurek MD Cetin Erol MD 《Pacing and clinical electrophysiology : PACE》2018,41(9):1060-1068
Background
Radiofrequency (RF) ablation of idiopathic ventricular arrhythmias (IVA) from the coronary venous system (CVS) has been increasingly performed, but real effect of ablation lesions from CVS on epicardial myocardium has not been studied.Objective
To compare effects of RF delivered inside the distal CVS during ablation of IVAs originating from left ventricular summit (LVS) with IVAs ablated from right ventricular outflow tract (RVOT) using cardiac magnetic resonance imaging (CMRI).Methods
Twenty consecutive patients with IVAs who underwent acutely successful RF ablation at initial appropriate sites, i.e., distal CVS (Group 1, n = 10) or RVOT (Group 2; n = 10) were enrolled. Detailed contrast‐enhanced CMRI of each patient was performed 3 months later. Presence and location of scars, distance of CVS to epicardial ventricular myocardium were measured and analyzed.Results
Group 1 consisted of 10 and Group 2 consisted of 10 patients. Three months after the ablation, only three patients in Group 1 had detectable late gadolinium enhancement (LGE) on CMRI while nine out of 10 patients in Group 2 had evident LGE on CMRI (P: 0.02). The mean distance of distal CVS to epicardial anterobasal myocardium was measured to be 8.8 ± 1.6 mm in Group 1. In three cases that had detectable scar on superior anterobasal LV epicardium, the mean distance was 7.4 ± 1.1 mm.Conclusions
RF delivery inside the CVS is less likely to produce detectable LGE on CMRI compared to RVOT. This may partially explain less than ideal long‐term results after ablation of LVS IVAs from within the great cardiac vein/anterior interventricular vein.4.
D'Avila A Gutierrez P Scanavacca M Reddy V Lustgarten DL Sosa E Ramires JA 《Pacing and clinical electrophysiology : PACE》2002,25(10):1488-1495
This study evaluates the effects of epicardial RF ablation on the coronary vessels in a canine model. Nonsurgical epicardial catheter ablation is a minimally invasive procedure that has proven to be efficacious for the treatment of VT. This approach is limited by concern regarding the potential adverse effects of RF ablation on the epicardial coronary arteries. After lateral thoracotomy, a multipolar linear ablation catheter was sewn adjacent to or crossing the LAD in nine mongrel dogs. Five of these dogs also had a standard 4-mm tip ablation catheter sewn adjacent to the LAD. RF pulses were delivered using temperature control. Animals were sacrificed 14 days after ablation for histological analyses. Using the 4-mm tip catheter, 22 consecutive single lesions of 2.67 +/- 0.35 mm depth were studied. The only coronary arterial change seen was replacement of the media with extracellular matrix. Using the linear ablation catheter, 117 pulses were applied to generate 24 linear lesions (3.8 +/- 1 mm depth). Replacement of the coronary arterial media with extracellular matrix proliferation was commonly seen, and severe hyperplasia occurred in one artery. Intravascular thrombosis occurred in six arteries. The internal perimeter of the vessel (0.78 +/- 0.49 mm vs 1.79 +/- 0.83 mm) was the only variable associated with severe arterial damage. The effects of RF ablation delivered adjacent to the LAD were limited to the media but when delivered above the artery, severe intimal hyperplasia and intravascular thrombosis may occur. Susceptibility to damage is inversely proportional to the vessel size. 相似文献
5.
Impact of the distribution and structure of myocardium in the pulmonary veins for radiofrequency ablation of atrial fibrillation 总被引:12,自引:0,他引:12
Weiss C Gocht A Willems S Hoffmann M Risius T Meinertz T 《Pacing and clinical electrophysiology : PACE》2002,25(9):1352-1356
Focal AF is frequently triggered by ectopic beats mostly originating from the pulmonary veins (PVs). So far, the morphological substrate for this entity is not well defined. Therefore, the distribution of myocardial cells within the PV were examined as potential target sites for RF application. The PVs (118) of 30 human autopsied hearts (age of death 63 +/- 13 years, 17 men) were dissected in their complete circumference starting 1 cm from the ostium. Tissue sections of the PV were stained with hematoxylin-eosin and with Masson's trichrome. To characterize the developmental state of the myocardial tissue in the PV, immunohistochemistry was performed with antibodies reacting with antigens which are stage specifically expressed during cardiac development (HNK1/Leu7, alpha-SMA, calponin and desmin). Furthermore, proliferative activity was assessed using antibodies against the Ki-67 antigen (MIB-1). In two hearts a left-sided common PV ostium was found. The other hearts showed four separated PV ostia. The ostium diameter of the right inferior PV (1.2 +/- 0.3 cm) was significantly smaller (P < 0.05) than remaining PV ostia (right superior 1.5 +/- 0.2, left superior, 1.5 +/- 0.3 and left inferior 1.4 +/- 0.3 cm) of the 118 specimen. There was no significant difference in the presence of myocardium in the PV 1-cm distant from the ostium comparing the right superior (78%), the right inferior (81 %), the left superior (81%), and the left inferior (81%) PV. In 54% of cases the myocardial bundles covered the complete PV circumference. In up to 38% of the small extensions of the myocardial bundles myocardial cells, characterized by distinct cross-striations and spindle shape were found. However, since these cells could not be labeled for other markers than desmin, their immature state seems unlikely. The anatomic distribution of myocardium in the PV suggests that RF applied to the entire circumference may be frequently required for its electrical isolation. Whether spindle-shaped myocytes have different electrophysiological behavior has to be further investigated. 相似文献
6.
目的:探讨左心室分支起源的室性期前收缩(premature ventricular contraction,PVC)及左心室分支起源的室性心动过速(ventriculai tachycardia,VT)的心电生理特点及导管射频消融术的疗效。方法选取左心室分支起源的室性心律失常患者36例,其中 PVC 5例,VT 31例,在 Carto-3指导下行导管射频消融术治疗。结果5例PVC 患者射频消融成功率100%,31例 VT 患者中,2例患者术后复发,最终成功34例,成功率94.4%。结论 Carto-3指导下行分支性室性心律失常的射频消融治疗成功率高、并发症少、安全可靠。 相似文献
7.
Jia-Feng L Yue-Chun L Jia L Kang-Ting J Jia-Xuan L Ji-Fei T Peng-Lin Y 《Pacing and clinical electrophysiology : PACE》2012,35(5):e120-e123
This case report describes idiopathic ventricular tachycardia (VT) originating from the anterolateral site of mitral annulus. Radiofrequency (RF) energy application at an endocardial site of mitral annulus could not eliminate the tachycardia. The earliest epicardial activation preceding the onset of the QRS complex by 34 ms was found at the great anterior cardiac vein just opposite to the endocardial ablation catheter, pace mapping provided an identical (12/12) match with the VT morphology at the site, and RF ablation effectively eliminated the VT from the great cardiac vein within the coronary venous system. 相似文献
8.
Scanavacca M Sosa E d'Avila A De Lourdes Higuchi M 《Pacing and clinical electrophysiology : PACE》2002,25(3):368-371
This case report describes the electrophysiological findings of a 62-year-old patient with chronic Chagas' disease and two distinct morphologies of sustained ventricular tachycardia that involved a mitral isthmus. Multiple RF applications were necessary to obtain a bidirectional conduction block in the mitral isthmus that was related to the interruption of both tachycardias. After the procedure, the patient presented massive cerebral infarction that progressed to coma and death. Autopsy showed acute and old lesions at the mitral isthmus and recent mitral annulus thrombosis. 相似文献
9.
Matsudaira K Nakagawa H Wittkampf FH Yamanashi WS Imai S Pitha JV Lazzara R Jackman WM 《Pacing and clinical electrophysiology : PACE》2003,26(5):1227-1237
The authors hypothesized that during RF ablation, the electrode to tissue interface temperature may significantly exceed electrode temperature in the presence of cooling blood flow and produce thrombus. In 12 anesthetized dogs, the skin over the thigh muscle was incised and raised to form a cradle that was superfused with heparinized canine blood (ACT > 350 s) at 37 degrees C. A 7 Fr, 4-mm or 8-mm ablation electrode containing a thermocouple was held perpendicular to the thigh muscle at 10-g contact weight. Interface temperature was measured at opposite sides of the electrode using tiny optical probes. RF applications (n = 157) were delivered at an electrode temperature of 45 degrees C, 55 degrees C, 65 degrees C, and 75 degrees C for 60 seconds, with or without pulsatile blood flow (150 mL/min). Without blood flow, the interface temperature was similar to the electrode temperature. With blood flow, the interface temperature (side opposite blood flow) was up to 36 degrees C and 57 degrees C higher than the electrode temperature using the 4- and 8-mm electrodes, respectively. After each RF, the cradle was emptied and the electrode and interface were examined. Thrombus developed without impedance rise at an interface temperature as low as 73 degrees C without blood flow and 80 degrees C with blood flow (11/16 RFs at 65 degrees C electrode temperature using 4 mm and 13/13 RFs at an electrode temperature of 55 degrees C using an 8-mm electrode with blood flow). With blood flow, interface temperature markedly exceeded the electrode temperature and the difference was greater with an 8-mm electrode (due to greater electrode cooling). In the presence of blood flow, thrombus occurred without an impedance rise at an electrode temperature as low as 65 degrees C with a 4-mm electrode and 55 degrees C with an 8-mm electrode. 相似文献
10.
Pulmonary artery: A pivotal site for catheter ablation in idiopathic RVOT ventricular arrhythmias 下载免费PDF全文
Chunmiao Wang MD Yawen Zhang MD Fangde Hong MD Ying Huang 《Pacing and clinical electrophysiology : PACE》2017,40(7):803-807
In patients without associated myocardial diseases, characterized by left bundle branch block and inferior axis morphologies, repetitive idiopathic right ventricular tachycardias and ventricular premature contractions typically arise from right ventricular outflow tract (RVOT). Accumulated evidences have shown that radiofrequency catheter ablation is a useful treatment for patients with RVOT ventricular arrhythmias (VAs). Interestingly, several medical centers have shown that pulmonary artery (PA) is a potential novel site for catheter ablation in RVOT‐like VAs, particularly in patients where termination of RVOT VAs at the usual site fails. In this review, we comprehensively demonstrated that RVOT VAs were successfully terminated at the site of PA, analyzed the characteristics of surface electrocardiogram and endocardial potentials, and explored the underlying mechanisms for these cases. 相似文献
11.
《Expert review of cardiovascular therapy》2013,11(3):333-340
Since the introduction of transcatheter ablation in the late 1980s, there has been significant technical development. With a very high success rate and low complication rate, ablation has now become the standard of care in children and adults. However, long-term data remain insufficient and the application of ablation therapy in small children is debatable. In this review, current treatment strategies and results in toddlers and infants will be discussed. There has been improvement in success rate and complication rate for ablation in small children. Technological advancements in non-fluoroscopic electroanatomical mapping systems (3D systems) have led to the reduction of radiation and have facilitated ablations in complex cases. However, long-term effects of ablation lesions in small children remain a potential concern. 相似文献
12.
New simplified technique for 3D mapping and ablation of right ventricular outflow tract tachycardia 总被引:2,自引:0,他引:2
Saleem MA Burkett S Passman R Dibs S Engelstein ED Kadish AH Goldberger JJ 《Pacing and clinical electrophysiology : PACE》2005,28(5):397-403
OBJECTIVE: To evaluate the safety and efficacy of using a circular multielectrode catheter for mapping and ablation of ventricular tachycardia (VT) or premature ventricular complexes (PVCs) from the right ventricular outflow tract (RVOT). BACKGROUND: Three-dimensional (3D) mapping systems are commonly used for mapping and ablation of RVOT VT and PVCs. Newer catheters that are circular with multiple electrodes, such as the Lasso catheter, are capable of simultaneously recording from multiple points within a circumferential plane. Given the tubular structure of the RVOT, these catheters could be used for mapping tachycardias from the RVOT. METHODS: A retrospective cohort study of patients undergoing radiofrequency (RF) ablation of RVOT VT or PVCs was performed. In group 1 (n = 7), mapping was performed with a single ablation catheter and fluoroscopy. In group 2 (n = 10), 3D mapping using ESI (n = 9) or CARTO (n = 1) was performed. In group 3 (n = 12), mapping was performed with a circular multielectrode catheter (n = 12). All ablations were performed with 4-mm tip catheters using RF energy. RESULTS: Catheter ablation for RVOT VT (n = 15) or PVCs (n = 14) was performed on 29 cases in 26 patients, 9 males. Mean age was 35.9 years. In groups 1, 2, and 3, the mean number of lesions was 17.7 +/- 7.7, 13.6 +/- 7.7, and 18.2 +/- 22.7 and the median number of lesions was 20, 13, and 5, respectively. There were no significant differences in the number of lesions, RF time, fluoroscopy time, procedure time, and acute success rate among the three techniques. There were three complications in group 2 and one in group 3. CONCLUSION: The use of a circular multielectrode catheter is as effective as the other standard available 3D mapping techniques, both in terms of procedural success and procedural characteristics. Additionally, because of the lower cost associated with using the circular multielectrode catheter approach, further evaluation should be performed to determine whether this is the most cost-effective approach to 3D mapping and ablation of RVOT tachycardias. 相似文献
13.
《Expert review of cardiovascular therapy》2013,11(5):711-720
The coronary sinus (CS) is a complex structure of particular interest to cardiac electrophysiologists. It is exploited as an anatomical reference, a site to record left-sided atrial and ventricular signals and for cardiac resynchronization therapy. Perhaps less appreciated, it may itself serve as a substrate for arrhythmias. It is now increasingly recognized that arrhythmias may be targeted by transcatheter ablation within the CS. This review summarizes pertinent anatomic considerations, explores the relationship between the CS and various arrhythmia substrates, elaborates on current indications for intra CS ablation and addresses efficacy and safety concerns associated with transcatheter ablation. 相似文献
14.
Radiofrequency ablation of the ventricular tachycardia with arrhythmogenic right ventricular cardiomyopathy using non-contact mapping 总被引:4,自引:0,他引:4
Yao Y Zhang S He DS Zhang K Hua W Chu J Pu J Chen K Wang F Chen X 《Pacing and clinical electrophysiology : PACE》2007,30(4):526-533
BACKGROUND: Intracardiac non-contact mapping provides a rapid and accurate isopotential mapping that facilitates catheter ablation of the ventricular tachyarrhythmias in arrhythmogenic right ventricular cardiomyopathy (ARVC). METHODS: Thirty-two consecutive patients (26 men and 6 women, mean 37.2 +/- 13.8 years) were treated with ablation. Fourteen patients had a history of syncope/pre-syncope. Two patients had an implantable cardiac defibrillator (ICD) previously implanted. RESULTS: There were 67 ventricular tachycardias (VTs) induced in the 32 patients. The average VT rate was 210 +/- 32.2 (130-310) bpm. There were 42 episodes of VT that had a heart rate > or =200 bpm and 24 of the 32 patients (75%) had > or =2 morphologies of VT. Regional ablation was applied by targeting the earliest VT activation sites under the guidance of non-contact mapping. Acute success was achieved in 84.4% (27/32) patients, and significant improvement was seen in 15.6% (5/32) patients as evidenced by a slower rate of VT. None of the patients experienced syncope/pre-syncope or sudden death during the 28.6 +/- 16 (9-72) month follow-up. There were no complications of the procedure. At the end of follow-up, 81.3% of the patients were free of VT without medication while the rest of the patients achieved a modified success. CONCLUSIONS: The rapid ventricular tachyarrhythmias in ARVC patients can be abolished or improved significantly by regional RF catheter ablation under the guidance of non-contact mapping. There was no sudden cardiac arrest or death in those patients without ICD implantation. Delayed efficacy may occur in some patients after ablation. 相似文献
15.
Yamada T McElderry HT Doppalapudi H Kay GN 《Pacing and clinical electrophysiology : PACE》2008,31(5):618-620
A 67-year-old man who developed sustained ventricular tachycardia (VT) 4 years after a prosthetic aortic valve replacement, underwent electrophysiologic testing and catheter ablation. The mechanism of the VT was suggested to be triggered activity because the VT could be induced by programmed ventricular stimulation, and burst ventricular pacing demonstrated overdrive suppression without a transient entrainment. Successful catheter ablation using a transseptal approach was achieved underneath the mechanical prosthetic aortic valve on the blind side for that approach. This case demonstrated that catheter mapping and ablation of the entire LV using a transseptal approach might be possible. 相似文献
16.
A 21-year-old woman was admitted for evaluation of recurrent episodes of syncope. She had several spontaneous and abrupt loss of consciousness episodes while at the emergency department, caused by sustained and nonsustained ventricular fibrillation episodes. Each episode was initiated by a certain premature ventricular complex, which remained the same in subsequent ventricular fibrillation episodes. She had a total of eight more episodes of ventricular fibrillation during her admission, despite administration of intravenous antiarrhythmic agents. A diagnosis of idiopathic ventricular fibrillation was made. Radiofrequency catheter ablation was performed, targeting the distal Purkinje system. Ventricular fibrillation was noninducible after the procedure, and the patient has been symptom-free for the past 1 year. 相似文献
17.
Ablation of noninducible idiopathic left ventricular tachycardia using a noncontact map acquired from a premature complex with tachycardia morphology 总被引:12,自引:0,他引:12
Friedman PA Beinborn DA Schultz J Hammill SC 《Pacing and clinical electrophysiology : PACE》2000,23(8):1311-1314
We describe use of a novel noncontact system to permit mapping in a noninducible patient from a single premature ventricular complex with tachycardia morphology, thus guiding successful ablation after two previously failed conventional efforts. The instantaneous global electroanatomic map demonstrated fascicular macroreentry. Subsequent to ablation at an inferolateral site, there has been no clinical recurrence despite difficult arrhythmia control preprocedure. This case demonstrated that noncontact mapping can be used to create a potential map to guide successful ablation from a single premature ventricular complex in a patient with idiopathic left ventricular tachycardia that became noninducible at electrophysiological study. 相似文献
18.
Tada H Naito S Ito S Kurosaki K Ueda M Shinbo G Hoshizaki H Oshima S Taniguchi K Nogami A 《Pacing and clinical electrophysiology : PACE》2004,27(8):1053-1059
The aim of this study was to identify the characteristics of electrograms that may be helpful in predicting successful ablation of idiopathic ventricular tachycardia from the aortic sinus of Valsalva. Data were obtained from 23 patients with symptomatic ventricular tachycardia or premature ventricular contractions (LV-VT) who underwent RF catheter ablation from the left sinus of Valsalva. Electrograms before and after application of RF energy during sinus rhythm and during LV-VT were analyzed. Complete elimination of LV-VT was finally achieved in 21 (91%) patients. The incidence of presystolic potentials preceding the QRS complex of LV-VT (P1 potential) was 90% for the 21 successful ablation sites, which did not differ from the incidence for the 24 unsuccessful sites (79%; P = 0.5). During sinus rhythm, a potential following the QRS complex (P2 potential) was more often recorded at the successful ablation site than at an unsuccessful ablation site before and after application of RF energy (before, P < 0.05; after, P < 0.001). The appearance of the P2 potential or a delay in the preexisting P2 potential after application of RF energy was observed only at the successful ablation sites (P < 0.001). In 18 control individuals who had no LV-VT, no P2 potential was recorded within the left sinus of Valsalva. Although the P1 potential may be useful for identifying the successful ablation site, its sensitivity is low. The appearance of the P2 potential or an increasingly delayed P2 potential after application of RF energy may be more useful than the P1 potential for predicting successful ablation. 相似文献
19.
目的观察射频消融(RFCA)治疗9例特发性室性心动过速(IVT)方法和结果。方法分别行激动顺序标测法和起搏标测法,对左室特发性室速(ILVT)7例,右室特发性室速2例,行射频消融治疗。结果6例ILVT射频消融治疗成功,均起源于左室间隔面,有效消融靶点处P电位较体表心电图QRS起始点提前(34.6±8.9)m s(25~58 m s),2例IRVT射频消融成功,有效消融靶点处与心动过速时的12导联心电图QRS波形完全相同。无一例出现并发症。结论射频消融是治疗特发性室性心动过速的有效方法。 相似文献
20.
Petersen HH Chen X Pietersen A Svendsen JH Haunsø S 《Pacing and clinical electrophysiology : PACE》2000,23(1):8-17
The limited success rate of radiofrequency catheter ablation in patients with ventricular tachycardias related to structural heart disease may be increased by enlarging the lesion size. Irrigated tip catheter ablation is a new method for enlarging the size of the lesion. It was introduced in the power-controlled mode with high power and high infusion rate, and is associated with an increased risk of crater formation, which is related to high tissue temperatures. The present study explored the tissue temperatures during temperature-controlled irrigated tip ablation, comparing it with standard temperature-controlled ablation and power-controlled irrigated tip ablation. In vitro strips of porcine left ventricular myocardium were ablated. Temperature-controlled irrigated tip ablation at target temperatures 60 degrees C, 70 degrees C, and 80 degrees C with infusion of 1 mL saline/min were compared with standard temperature-controlled ablation at 70 degrees C and power-controlled irrigated tip ablation at 40 W, and infusion of 20 mL/min. Lesion size and tissue temperatures were significantly higher during all modes of irrigated tip ablation compared with standard temperature-controlled ablation (P < 0.05). Lesion volume correlated positively with tissue temperature (r = 0.87). The maximum recorded tissue temperature was always 1 mm from the ablation electrode and was 67 +/- 4 degrees C for standard ablation and 93 +/- 6 degrees C, 99 +/- 6 degrees C, and 115 +/- 13 degrees C for temperature-controlled irrigated tip ablation at 60 degrees C, 70 degrees C, and 80 degrees C, respectively, and 112 +/- 12 degrees C for power-controlled irrigated tip ablation, which for irrigated tip ablation was significantly higher than tip temperature (P < 0.0001). Crater formation only occurred at tissue temperatures > 100 degrees C. We conclude that irrigated tip catheter ablation increases lesion size and tissue temperatures compared with standard ablation in the temperature-controlled mode at the same or higher target temperatures and in the power-controlled mode. Furthermore, tissue temperature and delivered power are the best indicators of lesion volume during temperature-controlled ablation. 相似文献