首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP.

Methods

This prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automated-endothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland–Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP.

Results

iCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, P<0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of −6.5±1.9 mm Hg, P<0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes.

Conclusions

The agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP.  相似文献   

2.

Pupose:

The purpose of this study was to compare the biomechanical properties of the cornea and intraocular pressure (IOP) between patients with systemic lupus erythematosis (SLE) and age-matched controls.

Patients and Methods:

In this prospective study, 30 healthy individuals (control group) and 30 patients with SLE (study group) underwent Reichert ocular response analyzer (ORA) measurements. In the right eye of each participant, the corneal hysteresis (CH), corneal resistance factor (CRF), and Goldman-related IOP (IOPg) were recorded using the ORA.

Results:

Mean CH, CRF, IOPg were significantly different between groups. Mean CH was 10.2±0.6 mm Hg in the study group and 11.3±1.3 in the control group (P=0.02); mean CRF was 9.7±1.1 mm Hg and 11.9±1.5 mm Hg, respectively (P=0.001). Mean IOPg was 13.9±2.9 mm Hg in the study group and 16.9±2.6 mm Hg in the control group (P=0.001).

Conclusion:

The biomechanical properties of the cornea are altered in patients with SLE compared with normal controls. These findings should be taken into account when measuring IOP values in patients with SLE as IOP readings may be underestimated in SLE eyes.  相似文献   

3.

Purpose

To measure corneal hysteresis and intraocular pressure (IOP) in patients with dry eye and to compare with normal subjects.

Methods

This cross-sectional study consists of 70 eyes of 40 patients with dry eye (group 1) and 75 eyes of 40 normal subjects (group 2). Eyes were diagnosed as dry eye or normal according to the clinical symptoms, biomicroscopical evaluation, and Schirmer test. Corneal hysteresis (CH), corneal resistance factor (CRF), and cornea-compensated intraocular pressure (IOPcc) were measured by the Ocular Response Analyser (ORA).

Results

Mean CH values were 10.56±0.25 mm Hg and 10.34±0.26 mm Hg, mean CRF values were 10.75±0.28 mm Hg and 10.70±0.28 mm Hg, mean CCT values were 542±3.20 μm and 543±3.89 μm in group 1 and group 2, respectively. There was no statistically significant difference between the groups for these three parameters. IOPcc values measured with ORA were 15.73±0.36 mm Hg in group 1 and 16.60±0.33 mm Hg in group 2, and there was no statistically significant difference between the two groups.

Conclusions

Corneal biomechanical parameters such as CH and CRF are not influenced in dry eye. Also statistical difference was not found between the two groups according to CCT and IOPcc values.  相似文献   

4.
AIM: To investigate the accuracy of intraocular pressure (IOP) as measured by a Reichert Ocular Response Analyzer (ORA), as well as the relationship between central corneal thickness (CCT) and IOP as measured by ORA, Goldmann applanation tonometry (GAT), and dynamic contour tonometry (DCT). METHODS: A total of 158 healthy individuals (296 eyes) were chosen randomly for measurement of IOP. After CCT was measured using A-ultrasound (A-US), IOP was measured by ORA, GAT, and DCT devices in a randomized order. The IOP values acquired using each of the three tonometries were compared, and the relationship between CCT and IOP values were analyzed separately. Two IOP values, Goldmann-correlated IOP value (IOPg) and corneal-compensated intraocular pressure (IOPcc), were got using ORA. Three groups were defined according to CCT: 1) thin cornea (CCT<520μm); 2) normal-thickness cornea (CCT: 520–580μm); and 3) thick cornea (CCT>580μm) groups. RESULTS: In normal subjects, IOP measurements were 14.95±2.99mmHg with ORA (IOPg), 15.21±2.77mmHg with ORA (IOPcc), 15.22±2.77mmHg with GAT, and 15.49±2.56mmHg with DCT. Mean differences were 0.01±2.29mmHg between IOPcc and GAT (P>0.05) and 0.28±2.20mmHg between IOPcc and DCT (P>0.05). There was a greater correlation between IOPcc and DCT (r=0.946, P=0.000) than that between IOPcc and GAT (r=0.845, P=0.000). DCT had a significant correlation with GAT (r=0.854, P=0.000). GAT was moderately correlated with CCT (r=0.296, P<0.001), while IOPcc showed a weak but significant correlation with CCT (r=?0.155, P=0.007). There was a strong negative correlation between CCT and the difference between IOPcc and GAT(r=-0.803,P=0.000), with every 10μm increase in CCT resulting in an increase in this difference of 0.35mmHg. The thick cornea group (CCT>580μm) showed the least significant correlation between IOPcc and GAT (r=0.859, P=0.000); while the thin cornea group (CCT<520μm) had the most significant correlation between IOPcc and GAT (r=0.926, P=0.000). The correlated differences between IOPcc and DCT were not significant in any of the three groups (P>0.05). CONCLUSION: Measurement of IOP by ORA has high repeatability and is largely consistent with GAT measurements. Moreover, the ORA measurements are affected only to a small extent by CCT, and are likely to be much closer to the real IOP value than GAT.  相似文献   

5.

Purpose

To evaluate the influence of silicone hydrogel contact lenses on the intraocular pressure (IOP) measurement using Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), and Pascal dynamic contour tonometry (DCT).

Methods

We included in the study 40 eyes of 40 patients who did not have any ocular or systemic diseases or contraindications to contact lens use. We measured and recorded the IOP values of each patient using NCT without and with contact lenses (groups 1 and 2, respectively), using DCT without and with contact lenses (groups 3 and 4, respectively), and using GAT without contact lenses (group 5).

Results

The mean IOP value of group 1 was 14.55±2.95 mm Hg and 13.92±2.58 mm Hg in group 2. We detected no statistically significant difference between group 1 and group 2 (P=0.053). The mean IOP values for group 3 and group 4 were 16.26±2.33 mm Hg and 15.19±2.40 mm Hg, respectively. We detected a statistically significant difference between groups 3 and 4 (P=0.005). Group 5''s mean IOP value was 12.97±2.65 mm Hg. IOP values measured with DCT were statistically significantly higher compared with IOP values measured with NCT and GAT (P<0.0001 and P<0.0001, respectively). Additionally, IOP values measured with NCT were statistically significantly higher compared with IOP values measured with GAT (P<0.0001).

Conclusion

According to the results of our study, silicone hydrogel soft contact lens use does not significantly affect IOP values measured with NCT, but it affects IOP values measured with DCT.  相似文献   

6.
目的比较眼反应分析仪(ORA)与非接触眼压计(NCT)测量眼压结果的差异,分析ORA、NCT测量结果与角膜中央厚度(CCT)的关系。方法近视患者57例(114只眼),于准分子激光手术前行ORA测量,得出角膜补偿眼压(IOPcc)和Goldmann相关眼压值(IOPg)两个数值,NCT测眼压3次取平均值。结果 ORA测得IOPcc平均值16.85 mm Hg,IOPpg平均值15.26 mm Hg,NCT眼压计测得平均值15.66 mm Hg;IOPcc>NCT>IOPg。IOPcc、IOPg与NCT所测眼压值比较,差异均有统计学意义(P<0.05)。NCT和IOPg均与CCT呈正相关(r:分别为0.463和0.419,P<0.05);IOPcc与CCT无相关性(r:0.230,P>0.05)。结论 ORA测量屈光不正患者的眼压与NCT测量结果存在一定差异,其中IOPcc不受角膜厚度的影响,在临床运用中准确性较好。  相似文献   

7.

Purpose

Given the Veterans Affairs Boston Healthcare System''s recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting.

Methods

Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test–retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements.

Results

The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3–34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=−1.05 was significantly different from the hypothesized value. The Tonosafe test–retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability.

Conclusions

The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.  相似文献   

8.
Comparison of IOP measurements between ORA and GAT in normal Chinese.   总被引:2,自引:0,他引:2  
PURPOSE: To compare intraocular pressure (IOP) obtained from the ocular response analyzer (ORA) and Goldmann applanation tonometer (GAT) on a group of normal Chinese. METHODS: One hundred twenty-five normal subjects were recruited, with one eye randomly selected for this study. Each eye was measured first with the noncontact tonometer ORA, followed by the GAT and ultrasound pachometry, in a randomized order. Four readings were obtained from the ORA, and three measurements were taken with the GAT. The mean was used for analysis. The ORA provided a Goldmann-correlated IOP (IOPg) and a corneal-compensated IOP (IOPcc). Three central corneal thickness (CCT) values were measured using an ultrasound pachometer, and the mean was used for analysis. RESULTS: IOP obtained from the ORA was similar to that from the GAT (IOPg minus GAT: mean difference = 0.33 mm Hg, 95% limits of agreement = 4.55 to -4.44 mm Hg; IOPcc minus GAT: mean difference = 0.24 mm Hg, 95% limits of agreement = 4.83 to -5.07 mm Hg). CCT was positively associated with corneal hysteresis (CH) (r2 = 0.30, p < 0.01), corneal resistance factor (r2 = 0.38, p < 0.01), GAT (r2 = 0.09, p < 0.01) and IOPg (r2 = 0.16, p < 0.01). IOPcc was not associated with CCT (r2 = 0.01, p = 0.33). CONCLUSIONS: Both IOPg and IOPcc have good agreement with GAT on normal subjects. The influence of CCT on IOPcc was insignificant.  相似文献   

9.
AIM: To analyze the correlation of Goldmann applanation tonometer (GAT), I-Care tonometer and Tono-Pen tonometer results in young healthy persons, and to investigate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements recorded with these tonometers. METHODS: We conducted a pilot clinical study in 78 eyes of 78 subjects aged 22-28 years old (44 women and 34 men; mean age 23.8±1.19y). IOP was measured using GAT, I-Care and Tono-Pen tonometers, followed by measurements of CCT. Statistical analysis was performed using SPSS 20.0. RESULTS: The mean IOPs and standard deviation (±SD) for GAT, I-Care and Tono-Pen were 15.62±2.281 mm Hg, 16.29±2.726 mm Hg and 16.32±2.393 mm Hg, respectively. The mean CCT was 555.15±29.648 μm. Clear positive correlations between GAT and I-Care, GAT and Tono-Pen, and I-Care and Tono-Pen tonometers were found (r=0.867, P<0.001; r=0.861, P<0.001; r=0.915, P<0.001, respectively). In comparison between devices, Bland–Altman analysis showed a significant mean difference (MD) in the measurements by GAT and I-Care of ?0.679 mm Hg and by GAT and Tono-Pen of ?0.705 mm Hg ( P<0.001), but there was no significant difference between I-Care and Tono-Pen ( P>0.05). Both non-gold standard tonometers were affected by CCT; that is, both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means (>555 μm; MD=?1.282, P<0.001; MD=?0.949, P<0.001, respectively) compared with GAT. CONCLUSION: Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values. Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results. Higher CCT values (>555 μm) were associated with overestimated IOP values.  相似文献   

10.
目的 比较眼反应分析仪测得的角膜补偿眼压(corneal-compensated intraocular pressure,IOPcc)和Sirius眼前节分析系统内置的5种眼压校正公式所得校正眼压的一致性,分析IOPcc、模拟Goldmann眼压(Goldmann-correlated intraocular pressure,IOPg)与眼球各参数的相关性。方法 选取2016年11月至2017年3月在我院眼科中心行近视激光治疗的患者90例90眼,年龄18~37(24.47±5.57)岁。应用Sirius眼前节分析系统对所有患者按常规方法测量3次,选择最佳测量结果作为各参数最终结果。应用眼反应分析仪测量患者的角膜生物力学参数。根据眼反应分析仪测量的IOPg输入Sirius眼前节分析系统内置的5种眼压校正公式进行计算,得到的校正眼压分别记录为Dresdner校正眼压、Ehlers校正眼压、Kohlhaas校正眼压、Orssengo/Pye校正眼压和Shah校正眼压。将所得的5种校正眼压和非接触性眼压计眼压与眼反应分析仪测得的IOPcc进行一致性分析。对IOPcc、IOPg与角膜滞后量、角膜阻力因子、眼球各参数进行相关分析。结果 Kohlhaas校正眼压和IOPcc比较差异有统计学意义(P<0.05)。Dresdner校正眼压、Orssengo/Pye校正眼压与IOPcc的一致性较好,95%一致性界限分别为 (-2.09~2.55)mmHg、(-2.38~2.37)mmHg;其中Dresdner校正眼压与IOPcc的95%一致性界限宽度最窄。IOPcc与角膜滞后量、角膜阻力因子以及眼球各参数均无相关性,而IOPg与角膜阻力因子、中央角膜厚度、角膜体积呈正相关关系 (均为P<0.05)。结论 Dresdner校正眼压、Orssengo/Pye校正眼压与IOPcc的一致性较好;眼球大部分参数对IOPcc影响小。  相似文献   

11.

Purpose

To compare the intraocular pressure (IOP) after 23-gauge transconjunctival sutureless vitrectomy (TSV) and conventional 20-gauge vitrectomy for various vitreoretinal diseases.

Methods

This was a retrospective interventional case series including 338 cases of 23-gauge TSV and 476 cases of 20-gauge vitrectomy with minimum follow-up period of 1 month. Postoperative 1 day, 1 week and 1 month IOPs were compared. Multiple regression analysis to assess the actual effect of gauge of vitrectomy on postoperative IOP was performed including intraoperative and postoperative factors influencing postoperative IOP as covariates.

Results

The mean IOP of 20-gauge vitrectomy was significantly higher than that of 23-gauge TSV (20.6±8.02 mm Hg vs12.8±4.48 mm Hg, P<0.001) at postoperative day 1, but the differences were not significant at postoperative 1 week and 1 month. The IOP pattern of 23-gauge TSV demonstrated more stable course than that of 20-gauge vitrectomy. At 1 day post vitrectomy, the incidence of hypertony was higher in 20-gauge, whereas that of hypotony was higher in 23-gauge. Among risk factors, the 20-gauge vitrectomy showed the strongest association with postoperative 1 day IOP rise.

Conclusion

Twenty-three-gauge TSV has stable and lower IOP in the early postoperative period than the 20-gauge vitrectomy. In patients whose retina and optic nerves are vulnerable to higher or fluctuating IOP, 23-gauge TSV may be more beneficial.  相似文献   

12.
AIM:To compare intraocular pressure(IOP)measurements before and after laser in situ keratomileusis(LASIK)with a femtosecond laser for flap creation using ocular response analyzer(ORA)and Goldmann applanation tonometry,and to identify factors that may influence the preoperative and postoperative IOP.METHODS:A prospective study conducted on myopic patients who underwent LASIK using a femtosecond laser for flap fashioning.Enrolled patients were evaluated preoperatively,6 wk and 3 mo postoperatively for manifest refraction(MR),keratometric(K)readings and central corneal thickness(CCT)using a scheimpflug-based topography.Corneal resistance factor(CRF),corneal hysteresis(CH),Goldmann correlated IOP(IOPg)and corneal compensated IOP(IOPcc)were measured using ORA besides IOP assessment by Goldman applanation tonometry(GAT).RESULTS:There was a statistically significant decrease in measures of IOPg by 3.35±0.83 mm Hg,followed by GAT which decreased by 2.2±0.44 mm Hg,and the least affected by operation was IOPcc which decreased only by 0.87±0.1 mm Hg after 6 wk.After 3 mo follow up there was a statistically significant decrease in IOPcc which decreased only by 0.76±0.4 mm Hg,followed by IOP GAT by 1.6±0.5 mm Hg,and the most affected by operation was IOPg which decreased by 2.3±0.3 mm Hg.Correspondingly,there was a statistically significant decrease in CH and CRF after 6 wk and 3 mo.At 3 mo,the preoperative MR and preoperative GAT were prominent significant predictors of the postoperative GAT changes.The prediction equation was subsumed.CONCLUSION:IOP measurements and corneal biomechanical factors reduce significantly after LASIK with a femtosecond laser for flap creation.The IOPcc values are less influenced by changes in corneal properties than IOPg and GAT,indicating that IOPcc may provide the most reliable measurement of IOP after this procedure.  相似文献   

13.

Purpose

To investigate the effect of orbital decompression surgery in thyroid orbitopathy (TO) on both refractive status and intraocular pressure (IOP).

Patients and methods

A prospective, multicentre, consecutive audit of patients undergoing thyroid decompression surgery. Indications for surgery included cosmetically unacceptable proptosis or corneal exposure. Exclusion criteria included the following: previous orbital surgery, glaucoma, corneal disease, steroid use in the preceding 12 months, or an acute optic neuropathy. Automated refraction, keratometry, pachymetry, Hertel exophthalmometry, and IOP were recorded at 1 month pre- and 3 months postoperatively. IOP using the Tono-Pen (mean of three readings) was measured in the primary, upgaze, and downgaze positions.

Results

Data were collected from 52 orbits of 33 patients (East Grinstead, New York, and Adelaide). There was no significant difference between pre- and postoperative data for sphere, cylinder, or central corneal thickness (CCT). The mean spherical equivalent was −0.43±1.49 D pre-operatively and −0.28±1.52 D postoperatively. The steepest meridian of corneal curvature was 93.1 degrees pre- and 94.2 degrees postoperatively, with no significant difference. Mean IOP significantly decreased when measuring by Goldmann applanation tonometry (GAT) (2.28 mm Hg, * P=0.001) and Tono-Pen (3.06 mm Hg, * P=<0.0001). IOP measured in upgaze was significantly greater than that in the primary position. Regression analysis between change in IOP and either Hertel exophthalmometry or the number of orbital walls decompressed was non-significant (*Student''s t-test).

Conclusion

Patients with TO undergoing orbital decompression had, on average, with-the-rule astigmatism not affected by orbital decompression surgery. IOP was significantly reduced by decompression surgery although no relationship between IOP and the degree of decompression was observed.  相似文献   

14.
Jiang Z  Shen M  Mao G  Chen D  Wang J  Qu J  Lu F 《Eye (London, England)》2011,25(8):1083-1089

Purpose

To examine the relationship between corneal biomechanical properties and the degree of myopia.

Methods

Chinese subjects (n=172, age: 11−65 years) were divided into diagnostic groups with non-myopia (spherical equivalence (SE)>−0.50 D), low (−3.00≤SE≤−0.50 D), moderate (−6.00≤SE<−3.00 D), and high myopia (SE<−6.00 D). Only the right eye of each subject was analyzed. Central corneal thickness (CCT) was measured by optical coherence tomography. An ocular response analyzer was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), intraocular pressure (IOP), and corneal compensated IOP (IOPcc). Refraction was measured by both automated and subjective refractometry and expressed as SE.

Results

CH was significantly lower in high myopia compared with both low and non-myopia (P≤0.002). CCT was 1.5 times more correlated to CH variation compared with refraction. Similarly, CRF was four times more dependent on CCT than refraction. CH (P<0.001) or CRF (P=0.005) was positively correlated to refraction. Both IOP and IOPcc were negatively correlated to refraction (P<0.001), respectively.

Conclusions

CH decreases only in high myopia. Refraction is positively correlated to both CH and CRF but negatively correlated to both IOP and IOPcc. These results indicate that the mechanical strength in anterior segment of the eye is compromised in high myopia. In addition, high myopia may increase the risk of glaucoma.  相似文献   

15.

Purpose

To report outcomes of deep sclerectomy (DS) with intraoperative mitomycin C (MMC) application in eyes with previous failed glaucoma surgery (GS) and/or cataract extraction (CE).

Patients and methods

Single-surgeon case series of 82 eyes of 82 patients undergoing DS with MMC. The patients had previous CE with IOL and/or conjunctival GS and treated intraocular pressure (IOP) >18 mm Hg. MMC (0.2 mg/ml) was applied for 2–3 min before scleral flap dissection. Complete success was defined as IOP between 6 and 21 mm Hg or a reduction of 20% from baseline without medications. Reoperation for glaucoma or related complications, or loss of light perception vision was considered as failure.

Results

Mean follow-up was 57.7±22.4 months with 78% of patients completing the 3-year follow-up. Mean IOP decreased from 24.0 mm Hg (22.3–25.6, 95% confidence intervals) to 13.4 mm Hg (12.0–14.2) at 3 years after surgery (P<0.001). There was a significant decrease in the number of glaucoma medications from 2.0±1 preoperatively, to 0.3±0.7, 3 years after surgery. Kaplan–Meier cumulative success rates were 85.6% at 1 year, 80.0% at 2 years, and 76% at 3 years. At 3 years, IOP was maintained <19 and 15 mm Hg in 83 and 70% of eyes, respectively. Fourteen eyes (17.1%) had complications. Delayed hypotony (IOP <6 mm Hg) was the commonest complication in five eyes (6.1%).

Conclusion

DS with MMC appears to be a safe and effective surgical procedure for eyes with previous intraocular surgery.  相似文献   

16.
AIM: To introduce a modified technique of internal limiting membrane (ILM) centripetal dragging and peeling to treat idiopathic macular hole (IMH) and to observe the ILM-retina adhesive forces. METHODS: Twenty-six consecutive patients with stage 3 to 4 IMH and followed up at least six months were enrolled. All patients underwent complete par plana vitrectomy, ILM dragging and peeling, fluid and gas exchange, 15% C3F8 tamponade and 2-week prone position. The best corrected visual acuity, macular hole evaluation by optical coherence tomography, and complications were evaluated. RESULTS: The mean diameter of IMH was 524±148 μm (range: 201-683 μm), with 21 cases (80.8%) greater than 400 μm. ILM dragging and peeling were successfully performed in all cases. Most of the ILM-retina adhesive forces are severe (42.3%, 11/26), followed by mild (38.5%, 10/26), and moderate (19.2%, 5/26). The mean follow-up duration was 21.2±6.1mo. The IMH was closed in 25 (96.3%) eyes. Visual acuity (logMAR) improved significantly from 1.2±0.6 preoperatively to 0.7±0.5 postoperatively (P<0.001). CONCLUSION: Preexisting ILM-retina adhesive force is found in IMH patients. With assistance of this force, this modified technique may help to release the IMH edges and improve the closure rate of large IMH.  相似文献   

17.

Purpose

The purpose of this study is to compare the safety and intraocular pressure (IOP)-lowering efficacy of travoprost/timolol in a benzalkonium chloride (BAK)-free fixed combination preserved with polyquaternium-1 (TRA/TIM BAK-free), with travoprost/timolol-fixed combination preserved with BAK (TRA/TIM), in patients with open-angle glaucoma or ocular hypertension.

Methods

In this prospective randomized controlled trial, subjects with IOP of at least 22 mm Hg in one or both eyes at 0900 h, and IOP of at least 21 mm Hg in one or both eyes at 1100 h and 1600 h at two eligibility visits were randomly assigned to receive either TRA/TIM BAK-free (n=195) or TRA/TIM (n=193), dosed once daily in the morning (0900 h) for 6 weeks. IOP was assessed at 0900 h, 1100 h, and 1600 h at each scheduled visit (baseline, 2 and 6 weeks after randomization).

Results

Mean IOP reduction across all visits and time points was 8.0 mm Hg in the TRA/TIM BAK-free group and 8.4 mm Hg in the TRA/TIM group (P=0.0943). The difference in mean IOP between groups ranged from 0.2 to 0.7 mm Hg across visits and time points, with a mean pooled difference of 0.4 mm Hg (95% CI: −0.1 to 0.8), demonstrating equivalence of the two formulations. The most common drug-related adverse event was hyperemia of the eye (ocular hyperemia and conjunctival hyperemia combined), occurring in 11.8% of the TRA/TIM BAK-free group and 13.0% of the TRA/TIM group.

Conclusion

Travoprost/timolol BAK-free demonstrated equivalence to travoprost/timolol preserved with BAK in efficacy. No clinically relevant differences in the safety profiles of travoprost/timolol BAK-free and travoprost/timolol preserved with BAK were identified.  相似文献   

18.

Purpose

The aim of this study was to investigate the incidence of intraocular pressure (IOP) elevation after resident-performed cataract surgery and to determine variables, which influence postoperative day 1 (POD1) IOP.

Methods

In all, 1111 consecutive cataract surgeries performed only by training residents between 1 July 2001 and 30 June 2006 were included. Elevated IOP was defined as ≥23 mm Hg. Surgeries were classified according to the presence of POD1-IOP elevation. Fisher''s exact test and Student t-test were used to compare both groups. Multivariate analyses using generalized estimating equations were performed to investigate predictor variables associated with POD1-IOP elevation.

Results

The average preoperative IOP was 16.0±3.2 mm Hg and the average POD1-IOP was 19.3±7.1 mm Hg, reflecting a significant increase in IOP (P<0.001, paired t-test). The incidence of POD1-IOP elevation ≥23 mm Hg was 22.0% (244/1111). Presence of glaucoma and ocular hypertension, higher preoperative IOP, and longer axial length were frequently encountered variables in the POD1-IOP elevation group (all P<0.05). Using a multivariate analysis, presence of glaucoma (P=0.004, OR=2.38; 95% confidence interval (95% CI)=1.31–4.30), presence of ocular hypertension (P=0.003, OR=6.09; 95% CI=1.81–20.47), higher preoperative IOP (P<0.001, OR=3.73; 95% CI=1.92–7.25), and longer axial length (P=0.01, OR=1.15; 95% CI=1.03–1.29) were significant predictive factors for POD1-IOP elevation.

Conclusions

IOP elevation on the first postoperative day following resident-performed cataract surgery occurred frequently (22.0%). Increased early postoperative IOP was associated with presence of glaucoma and ocular hypertension, higher preoperative IOP, and longer axial length.  相似文献   

19.

Aim

To verify the safety and efficacy of Ologen (OLO) implant as adjuvant compared with low-dosage mitomycin-C (MMC) in trabeculectomy.

Methods

This was a prospective randomized clinical trial with a 24-month follow-up. Forty glaucoma patients (40 eyes) were assigned to trabeculectomy with MMC or OLO. Primary outcome includes target IOP at ≤21, ≤17, and ≤15 mm Hg; complete (target IOP without medications), and qualified success (target IOP regardless of medications). Secondary outcomes include bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain optical coherence tomography (SD-OCT) examination; number of glaucoma medications; and frequency of postoperative adjunctive procedures and complications.

Results

The mean preoperative IOP was 26.5 (±5.2) in MMC and 27.3 (±6.0) in OLO eyes, without statistical significance. One-day postoperatively, the IOP dropped to 5.2 (±3.5) and 9.2 (±5.5) mm Hg, respectively (P=0.009). The IOP reduction was significant at end point in all groups (P=0.01), with a mean IOP of 16.0 (±2.9) and 16.5 (±2.1) mm Hg in MMC and OLO, respectively. The rates and Kaplan–Meier curves did not differ for both complete and qualified success at any target IOP. The bleb height in OLO group was higher than MMC one (P<0.05). SD-OCT analysis of successful/unsuccessful bleb in patients with or without complete success at IOP ≤17 mm Hg indicated a sensitivity of 83% and 73% and a specificity of 75% and 67%, respectively, for MMC and OLO groups. No adverse reaction to OLO was noted.

Conclusions

Our results suggest that OLO implant could be a new, safe, and effective alternative to MMC, with similar long-term success rate.  相似文献   

20.

Aim

The aim of this study is to compare the 24-hour efficacy of dorzolamide/timolol-fixed combination (DTFC) and brimonidine/timolol-fixed combination (BTFC) in primary open-angle glaucoma (POAG).

Methods

One eye each of 77 POAG patients was included in this prospective, observer-masked, crossover comparison. Following a 2-month timolol run-in period, patients had three intraocular pressure (IOP) measurements at 1000, 1200 and 1400 h while on timolol treatment. Patients showing at least a 20% IOP reduction on timolol were randomised to 3 months of therapy with DTFC or BTFC, and then were crossed over to the opposite therapy.

Results

Sixty POAG patients completed the study. The mean 24-hour IOP was significantly reduced with both the fixed combinations compared with the timolol-treated diurnal IOP (P<0.001). When the two fixed combinations were compared directly, DTFC demonstrated a lower mean 24-hour IOP level as compared with BTFC (mean difference: −0.7 mm Hg, 95% confidence interval (CI): (−1.0, −0.3), P<0.001). At two individual time points, DTFC significantly reduced IOP more than BTFC: at 1800 h (−1.0 mm Hg, 95% CI (−1.6,−0.5), P=0.001) and at 0200 (−0.9 mm Hg, 95% CI: (−1.4,−0.5), P=0.001). No significant difference existed for the other time points.

Conclusion

Both the fixed combinations significantly reduce 24-hour IOP in POAG. DTFC provided significantly better 24-hour efficacy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号