共查询到20条相似文献,搜索用时 42 毫秒
1.
Twenty-nine patients with known or suspected malignancy were studied with identical T1-weighted (spin echo [SE] and inversion recovery [IR]) and T2-weighted SE magnetic resonance (MR) imaging at 0.5 and 1.5 T to evaluate the relative sensitivities of these sequences for detecting focal hepatic lesions. At 0.5 T, 98 lesions were detected with the IR sequence, 86 with the T1-weighted SE sequence, and 96 with the T2-weighted sequence. At 1.5 T, 93 lesions were detected with the IR sequence, 70 with the T1-weighted SE sequence, and 99 with the T2-weighted sequence. Although the lack of pathologic correlation precluded establishment of true sensitivity and specificity rates, data showed that magnetic field strength resulted in no significant difference for detecting focal hepatic lesions. No single sequence was shown to be significantly superior, although the T1-weighted SE sequence at 1.5 T was significantly inferior to the other sequences for detecting focal hepatic lesions. T1-weighted SE imaging at 0.5 T was significantly inferior to T1-weighted IR and T2-weighted imaging at both magnetic field strengths for detecting focal lesions in the left lobe of the liver. The authors conclude that T1-weighted IR and T2-weighted sequences alone will result in optimal MR imaging for the detection of focal hepatic lesions at 0.5 and 1.5 T. 相似文献
2.
Prostatic disorders: MR imaging at 1.5 T 总被引:3,自引:0,他引:3
M E Phillips H Y Kressel C E Spritzer P H Arger A J Wein D Marinelli L Axel W B Gefter H M Pollack 《Radiology》1987,164(2):386-392
Pelvic magnetic resonance (MR) images obtained at 1.5 T of 31 men with known genitourinary disease were reviewed retrospectively. In most, peripheral and central prostatic zones could be seen on axial images obtained with long repetition times/echo times (TRs/TEs). The prostate had no specific signal intensity that enabled differentiation between benign and malignant changes. Each patient with known extracapsular prostatic carcinoma had a peripheral zone defect--1 cm or greater in diameter with ill-defined borders and relatively lower signal intensity than that of the remainder of the peripheral zone--that correlated with the site of clinical-pathologic involvement. Correlation of a peripheral zone defect on long TR/TE images as a sign for extracapsular spread of prostatic cancer was 100% sensitive, yet 54% specific, with excellent interobserver agreement. Stage A2 and B1 prostatic carcinoma was not detected. Benign prostatic hyperplasia was seen as centrally located proliferation and nodularity, usually with discrete margins and a wide spectrum of low- to high-signal-intensity features. MR imaging may have a role in differentiating between intracapsular and extracapsular prostatic carcinoma. 相似文献
3.
Thirty magnetic resonance (MR) examinations of the Achilles tendon were performed: 20 from patients without suspected tendon abnormalities; ten from patients with suspected tendon abnormalities. The appearance of the normal Achilles tendon is hypointense and flattened. Partial tears appeared as high-signal intratendinous collections, complete acute ruptures appeared as tendinous discontinuity, and uncomplicated surgical repairs appeared as areas of tendinous continuity with inhomogeneous signal in the operative site. Chronic tendinitis appeared as a diffuse thickening of the tendon. MR imaging of the Achilles tendon at 1.5 T enabled the determination of the degree of tendinous continuity, which may help with diagnosis, treatment, and the pacing of rehabilitation. 相似文献
4.
Normal maturation of the neonatal and infant brain: MR imaging at 1.5 T 总被引:26,自引:0,他引:26
5.
MR imaging of the larynx at 1.5 T 总被引:2,自引:0,他引:2
F Sakai G Gamsu W P Dillon D A Lynch T J Gilbert 《Journal of computer assisted tomography》1990,14(1):60-71
The normal magnetic resonance (MR) anatomy of the larynx at high field strength (1.5 T) was studied in 2 normal excised larynges and 62 subjects without laryngopharyngeal disease. The two normal excised larynges were imaged using a 1.5 T MR scanner with a 3 in diameter circular surface coil and a GE 9800 CT scanner. The larynges were sectioned transversely and the MR and CT images compared to gross and histologic sections. Unossified hyaline cartilage was intermediate in signal intensity on T1-weighted and proton density images and low in intensity on T2-weighted images. The signal intensity from ossified cartilage was determined by the amount of fatty marrow and was high in intensity on T1-weighted and proton density images and low to intermediate in intensity on T2-weighted images. A chemical shift artifact from high intensity fatty marrow obscured the calcified or ossified cortex of the major laryngeal cartilages along the frequency encoding axis. The epiglottic cartilage demonstrated an intermediate signal intensity on T1-weighted images and higher intensity on proton density and T2-weighted images. The intralaryngeal muscles were well demonstrated as low intensity structures. The conus elasticus and the vocal ligaments were not recognized as distinct structures. However, the quadrangular membrane and a previously undescribed membrane separating the preepiglottic and paralaryngeal spaces were shown on MR as low intensity linear structures. In the 62 subjects, MR at 1.5 T proved excellent for demonstrating the anatomical details of the major laryngeal cartilages, extra- and intralaryngeal muscles, ligaments, and soft tissues including the vocal cords, false vocal cords, laryngeal ventricles, aryepiglottic folds, preepiglottic space, and paralaryngeal spaces. Visibility and intensity of muscles, ligaments, and soft tissues did not depend on age or sex. The intensity pattern of the thyroid and cricoid cartilages demonstrated wide variations in the same sex and age groups, depending on the degree of ossification. However, they did show more high intensity foci in older men than in younger women. Magnetic resonance showed better contrast resolution and finer detail than CT scans in the same subjects. Magnetic resonance imaging at 1.5 T, with either a saddle-shaped neck surface coil or a 3 in diameter circular surface coil, provides high contrast and high spatial resolution images and could be useful for the diagnosis of lesions of the larynx.(ABSTRACT TRUNCATED AT 400 WORDS) 相似文献
6.
High-field surface coil magnetic resonance (MR) images were obtained of 12 ankles: two from healthy volunteers, seven from patients, and three from fresh cadavers. The cadaver ankles were sectioned in the coronal, sagittal, and axial planes for direct comparison with the MR images. Plain film confirmation of pathologic conditions was obtained in all patients, and five underwent arthroscopy or surgery, or both. MR imaging provided excellent delineation of ligaments and cartilaginous structures in all cases. 相似文献
7.
Aneurysmal bone cysts: MR imaging at 1.5 T 总被引:4,自引:0,他引:4
Two patients with aneurysmal bone cysts of the pelvis were imaged using a 1.5-T magnetic resonance imaging device. Findings included multiple internal septations, cysts with fluid-fluid levels of varying intensity, and an intact rim of low-intensity signal completely surrounding the lesion. These findings allow a specific diagnosis of aneurysmal bone cyst to be made. 相似文献
8.
Pituitary adenomas: high-resolution MR imaging at 1.5 T 总被引:3,自引:0,他引:3
The magnetic resonance (MR) images of 28 patients with surgically confirmed pituitary adenomas were retrospectively evaluated. The examinations were performed on a 1.5-T superconducting MR system using a multisection spin-echo technique with 3-mm-thick sections and a 256 X 256 matrix. T1- and T2-weighted images were obtained in sagittal and coronal planes. The MR findings were correlated with detailed operative reports and diagrams. There were 11 microadenomas and 17 macroadenomas. Ten of the microadenomas and all of the macroadenomas were accurately localized and their extent delineated, particularly on T1-weighted coronal sections. Adenomas typically appeared hypointense on T1-weighted coronal sections. The appearance on T2-weighted images was variable, and generally the lesions were less well seen. Involvement of parasellar structures, particularly the optic chiasm and cavernous sinuses, was accurately depicted. Cyst formation and hemorrhage could be characterized in some instances. In general, there was excellent correlation between MR imaging and operative findings. 相似文献
9.
Magnetic resonance (MR) images of the scrotum were obtained at 1.5 T in 20 subjects, 13 patients with intrascrotal pathologic conditions and seven healthy subjects. Characteristic MR imaging signals obtained on T1- and T2-weighted images allowed differentiation of testis from epididymis and spermatic cord. Masses were differentiated from normal testicular parenchyma in all cases. Atrophic or ischemic testes had lower signal intensity than normal testes on T2-weighted images. Hematoma displayed a characteristic high intensity on both T1- and T2-weighted images. Intratesticular and extratesticular pathologic conditions were readily differentiated. These results suggest that MR imaging is useful in the diagnosis of scrotal and testicular abnormalities. 相似文献
10.
W D Foley J B Kneeland J D Cates G M Kellman T L Lawson W D Middleton R E Hendrick 《AJR. American journal of roentgenology》1987,149(6):1155-1160
The relative efficacies of different spin-echo pulse sequences at 1.5 T were evaluated in the detection of focal hepatic disease. Pulse sequences compared were spin-echo with a repetition time (TR) of 200 msec and echo time (TE) of 20 msec, with six excitations; TR = 300 msec, TE = 20 msec, with 16 excitations (T1-weighted sequences); and a double spin-echo with TR = 2500 and TE = 25 and 70, with two excitations (proton-density-weighted and T2-weighted pulse sequences, respectively). Respiratory-motion compensation, which involved a recording of the phase-encoding gradients (Exorcist), was used for the last two sequences. Spin-echo with TR = 2500 msec and TE = 70 msec was superior in lesion detection and contrast-to-noise ratio. The proton-density-weighted and T2-weighted sequences with respiratory compensation produced better artifact suppression than did the short TR, short TE T1-weighted sequence with temporal averaging. In contradistinction to prior results at 0.6 T, T2-weighted pulse sequences appear superior to T1-weighted pulse sequences with multiple excitations for both lesion detection and artifact suppression at 1.5 T. 相似文献
11.
Prostatic carcinoma: staging with MR imaging at 1.5 T 总被引:5,自引:0,他引:5
Bezzi M; Kressel HY; Allen KS; Schiebler ML; Altman HG; Wein AJ; Pollack HM 《Radiology》1988,169(2):339-346
Magnetic resonance (MR) imaging was used to stage prostatic carcinoma in 81 patients with a proved diagnosis. MR imaging findings were correlated with histologic findings regarding the local extent of disease (37 patieNts) and the presence of nodal metastases (51 patients). Tumor nodules were detected in the peripheral zone (PZ) in 34 of 37 patients and were of low signal intensity compared with the signal of the PZ. Hemorrhage in the PZ represented a problem in tumor detection and in tumor volume measurement. When multiple criteria for local tumor spread were combined, MR imaging had a sensitivity of 72%, a specificity of 84%, and an accuracy of 78% in the differentiation of stage A or B from Stage C or D disease. Assessment of seminal vesicle invasion was more accurate than assessment of direct extracapsular spread. In five patients, microscopic invasion of the capsule (stage C) was classified as stage B with MR imaging; from a clinical standpoint, this should not affect patient treatment and prognosis. The MR imaging sensitivity in the detection of lymph node metastases was 69%, with a specificity of 95% and an accuracy of 88%. In this study MR imaging proved reliable in the comprehensive evaluation and staging of prostatic carcinoma. 相似文献
12.
Aoki S; Okada Y; Nishimura K; Barkovich AJ; Kjos BO; Brasch RC; Norman D 《Radiology》1989,172(2):381-385
Magnetic resonance (MR) images of the brain in 285 patients between the ages of 2 and 25 years were retrospectively studied to determine the appearance of brain iron accumulation. The globus pallidus, red nucleus, substantia nigra, and dentate nucleus were evaluated with long TR/TE (repetition time/echo time) spin-echo sequences and staged. All four regions in most patients were initially hyperintense compared with white matter (stage I) before becoming isointense (stage II) and subsequently hypointense (stage III). The globus pallidus was the first to reach stage III, the red nucleus and substantia nigra were next, and the dentate nucleus was last. In general, decreased signal intensity (stage III) was not seen in these regions in patients less than 10 years old; in most patients it was seen by age 25 years. The dentate nucleus decreased in signal intensity more slowly and inconsistently; only one-third of patients had reached stage III by age 25 years. The temporal sequence of normal iron deposition as detected with MR imaging is helpful not only in the diagnosis of known iron-deposition diseases but also in the detection of iron-related pathologic changes. 相似文献
13.
A Uchino N Ohnari M Ohno 《Nihon Igaku Hōshasen Gakkai zasshi. Nippon acta radiologica》1989,49(10):1243-1252
Twelve patients with acute hypertensive intracranial hemorrhage underwent magnetic resonance (MR) imaging within 7 days after the ictus. T1-weighted (TR = 400 msec; TE = 20 msec) and T2-weighted (TR = 2000 msec; TE = 80 msec) images were obtained on a 1.5 Tesla MR system. Signal intensities of hematomas were carefully evaluated and were compared with white matter intensity. A 9-hour-old hematoma was mildly hypointense on T1-weighted images, and was mildly hyperintense on T2-weighted images, suggesting a reflection of the high water content. On T2-weighted images, thin peripheral hypointense rim, probably due to deoxyhemoglobin, was also observed. Both of 15-hour-old hematoma and 21-hour-old hematoma had peripheral hypointensity on T2-weighted images. Both of 39-hour-old hematoma and 43-hour-old hematoma had central hyper-intensity on T1-weighted images and iso-to-mild central hypointensity on T2-weighted images, suggesting a reflection of decreased water content. A 3-day-old hematoma had thin peripheral iso-to-mild hyperintense rim on T1-weighted images, presumably due to intracellular methomoglobin. A 5-day-old hematoma had thin peripheral hyperintense rim on T2-weighted images, probably due to free methemoglobin. A 7-day-old hematoma was hyperintense on T1-weighted images and was mildly hypointense to hyperintense on T2-weighted images, presumably due to mixed intracellular methemoglobin and free methemoglobin. 相似文献
14.
Beltran J; Noto AM; Mosure JC; Weiss KL; Zuelzer W; Christoforidis AJ 《Radiology》1986,159(3):747-751
Seven normal knees (in five volunteers) and seven injured knees (in seven patients) were examined by high-resolution magnetic resonance (MR) imaging at 1.5 T with a surface coil. Seven medial meniscal tears, three anterior cruciate ligament tears, one posterior cruciate ligament avulsion, an old osteochondral fracture, femoral condylar chondromalacia, and one case of semimembranous tendon reinsertion were identified. MR images correlated well with recent double-contrast arthrograms or results of surgery. All tears were identified in both the sagittal and coronal planes. Because of its ability to demonstrate small meniscal lesions and ligamentous injuries readily, MR imaging with a surface coil may eventually replace the more invasive arthrography. 相似文献
15.
Acute spinal cord injury: MR imaging at 1.5 T 总被引:19,自引:0,他引:19
Kulkarni MV; McArdle CB; Kopanicky D; Miner M; Cotler HB; Lee KF; Harris JH 《Radiology》1987,164(3):837-843
Thirty-seven magnetic resonance (MR) imaging studies were performed with a 1.5-T magnet and surface coils in 27 patients with suspected spinal cord injuries. Imaging was performed 1 day to 6 weeks after injury. Cord abnormalities were seen with MR in 19 patients, while skeletal and/or ligamentous injuries were seen in 21 (78%). Three types of MR signal patterns were seen in association with cord injuries. Acute intraspinal hemorrhage was seen in five patients with cord injuries and demonstrated decreased signal intensity on T2-weighted images obtained within 24 hours of injury. Cord edema and contusion had high signal intensity on T2-weighted images and were observed in 12 cases with cord injury. Neurologic recovery, determined in 16 patients, was insignificant in patients with intraspinal hemorrhage; however, patients with cord edema or contusion recovered significant neurologic function. MR at 1.5 T is extremely useful in the diagnosis of acute cord injury and also demonstrates potential in predicting neurologic recovery. 相似文献
16.
Simon JH; Foster TH; Ketonen L; Totterman S; Szumowski J; Kido DK; Manzione JV Jr; Joy SE 《Radiology》1989,172(3):771-775
A decrease in the magnetic resonance (MR) imaging bandwidth can be used to increase the signal-to-noise ratio (S/N) at constant imaging time or to maintain the S/N for reduction of imaging time. The effect of bandwidth reduction from the default value of 16 kHz to 8 kHz was evaluated prospectively in 50 patients referred for MR imaging of the head. On intermediate (2,000/30 [repetition time msec/echo time msec]) and more T2-weighted (2,000/90) studies, there were no definite missed diagnoses and no diagnostically important changes in lesion characteristics when the reduced-bandwidth technique was used to obtain half- or quarter-time studies, excluding differences attributable to unintentional changes in patient position between image acquisitions. Chemical shift misregistration artifacts associated with reduced bandwidth are easily recognized with experience and do not interfere with diagnosis, as the artifacts occur in characteristic locations and diminish in most anatomic locations with increasing echo time. This study suggests the feasibility of reduced-bandwidth techniques in clinical MR imaging of the head at high field strength to achieve an increased S/N, to decrease imaging time, or to obtain images in additional projections. 相似文献
17.
Puderbach M Hintze C Ley S Eichinger M Kauczor HU Biederer J 《European journal of radiology》2007,64(3):345-355
Magnetic resonance imaging (MRI) is capable of imaging infiltrative lung diseases as well as solid lung pathologies with high sensitivity. The broad use of lung MRI was limited by the long study time as well as its sensitivity to motion and susceptibility artifacts. These disadvantages were overcome by the utilisation of new techniques such as parallel imaging. This article aims to propose a standard MR imaging protocol at 1.5T and presents a spectrum of indications. The standard protocol comprises non-contrast-enhanced sequences. Following a GRE localizer (2D-FLASH), a coronal T2w single-shot half-Fourier TSE (HASTE) sequence with a high sensitivity for infiltrates and a transversal T1w 3D-GRE (VIBE) sequence with a high sensitivity for small lesions are acquired in a single breath hold. Afterwards, a coronal steady-state free precession sequence (TrueFISP) in free breathing is obtained. This sequence has a high sensitivity for central pulmonary embolism. Distinct cardiac dysfunctions as well as an impairment of the breathing mechanism are visible. The last step of the basic protocol is a transversal T2w-STIR (T2-TIRM) in a multi-breath holds technique to visualize enlarged lymph nodes as well as skeletal lesions. The in-room time is approximately 15min. The extended protocol comprises contrast-enhanced sequences (3D-GRE sequence (VIBE) after contrast media; about five additional minutes). Indications are tumorous lesions, unclear (malignant) pleural effusions and inflammatory diseases (vaskulitis). A perfusion analysis can be achieved using a 3D-GRE in shared echo-technique (TREAT) with a high temporal resolution. This protocol can be completed using a MR-angiography (3D-FLASH) with high spatial resolution. The in-room time for the complete protocol is approximately 30min. 相似文献
18.
高场强原发性肝癌MR表现及分析 总被引:1,自引:0,他引:1
目的:分析高场强下原发性肝癌的MRI表现。方法:收集经手术或尸检病理证实的原发性肝癌MR资料43例,其中巨块型肝癌32例,其中伴子灶3例,结节型5例,小肝癌6例。设备为GE1.5T超导signa advantage MR。应用SET1WI,FSEPDWI,T2WI进行轴位扫描,所有病均行增强扫描。结果:肝癌在T1WI呈高、等、低信号,在T2WI呈高信号,部分肿瘤内部信号不均,肝癌的强化程度主要取决于肿瘤血供的多少,肝癌的包膜由纤维组织构成,表现为低信号环,无包膜的肿瘤门静脉侵犯发生率高,肿瘤的信号及包膜与其病理分级有一定的相关性。结论:MRI对反映原发性肝癌的病理特征有其独特的优越性。 相似文献
19.
Isthmic spondylolysis of the lumbar spine: MR imaging at 1.5 T 总被引:4,自引:0,他引:4
The appearance on magnetic resonance (MR) images of the normal pars interarticularis in 13 patients was reviewed and contrasted with that of the pars in eight patients with spondylolysis. The pars defect usually had an intermediate signal intensity with all pulse sequences; however, this intensity was somewhat variable depending on the exact ratio of cartilage, fat, and fluid within each bone defect. The pars defect was best seen with spin-echo 600/20 (repetition time msec/echo time msec) images. In three cases, out-of-phase images showed the spondylolysis best, because of extension of fat to the borders of the defect. The sagittal view allowed one to separate spondylolysis from the joint space of posterior facets since the orientation of the defects is perpendicular to the facets; thus, a common pitfall encountered with cross-sectional axial imaging techniques is avoided. MR imaging poorly delineated bone fragments around the defect, which may produce nerve root impingement, but revealed other numerous complications that occur with spondylolysis, including spondylolisthesis and herniation of the disk above. 相似文献
20.
Sound pressure levels (SPLs) during interventional magnetic resonance (MR) imaging may create an occupational hazard for the interventional radiologist (ie, the potential risk of hearing impairment). Therefore, A-weighted and linear continuous-equivalent SPLs were measured at the entrance of a 1.5-T MR imager during cardiovascular and real-time pulse sequences. The SPLs ranged from 81.5 to 99.3 dB (A-weighted scale), and frequencies were from 1 to 3 kHz. SPLs for the interventional radiologist exceeded a safe SPL of 80 dB (A-weighted scale) for all sequences; therefore, hearing protection is recommended. 相似文献