首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The Atlas? unicompartmental knee system is a second‐generation extra‐articular unloading implant for patients with mild to moderate medial knee osteoarthritis. The technology acts to reduce a portion of the weight‐bearing load exerted on the medial knee during physical activity thereby, reducing the mechanical stress imposed on a degenerative joint. The purpose of the present study was to evaluate the effects of the Atlas? on tibiofemoral joint mechanics during walking. A computer‐aided design assembly of the Atlas? was virtually implanted on the medial aspect of a previously validated finite element tibiofemoral joint model. Data for knee joint forces and moments from an anthropometrically matched male were applied to the model to quasi‐statically simulate the stance phase of gait. Predictions of tibiofemoral joint mechanics were computed pre‐ and post‐virtual implantation of the Atlas?. Compressive force in the medial tibiofemoral compartment was reduced by a mean of 53%, resulting in the decrement of mean cartilage–cartilage and cartilage–meniscus von Mises stress by 31% and 32%, respectively. The Atlas? was not predicted to transfer net loading to the lateral compartment. The tibiofemoral joint model exhibited less internal–external rotation and anterior–posterior translation post‐Atlas?, indicating a change in the kinematic environment of the knee. From a biomechanical perspective, extra‐articular joint unloading may serve as a treatment option for patients recalcitrant to conservative care. Evaluation of mechanical changes in the tibiofemoral joint demonstrate the potential treatment mechanism of the Atlas?, in accordance with the available clinical data. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2149–2156, 2019  相似文献   

2.
Substantial variation in total knee replacement (TKR) outcomes exists within the patient population. Some of this variability is due to differences in the design of the implanted components and variation in surgical alignment, while other variability is due to differences in the applied forces and torques due to anatomic and physiological differences within a patient population. We evaluated the relative contributions of implant design, surgical alignment, and patient‐specific loading variability to overall tibiofemoral joint mechanics to provide insight into which measures can be influenced through design and surgical decisions, and which are inherently dependent on variation within the patient population and should be considered in the robustness of the implant design and surgical procedure. Design, surgical, and loading parameters were assessed using probabilistic finite element methods during simulated stance‐phase gait and squat activities. Patient‐specific loading was found to be the primary contributor to joint loading and kinematics during low flexion, particularly under conditions of high external loads (for instance, the gait cycle with high internal–external torque), while design and surgical factors, particularly femoral posterior radius and posterior slope of the tibial insert became increasingly important in TKR performance in deeper flexion. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:2015–2024, 2012  相似文献   

3.
Tibiofemoral conformity and kinematics of rotating-bearing knee prostheses   总被引:7,自引:0,他引:7  
Increasing tibiofemoral articular conformity theoretically increases articular contact area and reduces contact stresses in total knee arthroplasty. Fixed-bearing knee designs possess relatively low tibiofemoral conformity, in part to allow tibiofemoral rotation without generating excessive stresses at the articulation or the implant-bone interface. This study analyzed knee kinematics of mobile-bearing designs in a closed chain dynamic knee extension model in posterior cruciate-retaining design with high- and low tibiofemoral conformity and posterior cruciate-substituting designs with and without rotational constraint. Overall, for all conditions, the mobile-bearing insert rotated with the femur in the presence of tibiofemoral axial rotation. In addition, the correlation of bearing rotation with femoral rotation was stronger for the high-conformity and rotationally-constrained designs than for the low-conformity designs and strongest for the posterior cruciate-retaining high-conformity condition. Changes in conformity or rotational constraint did not appear to affect femoral roll back, tibiofemoral axial rotation, or varus-valgus angulation. The results suggest that mobile-bearing inserts rotate with the femur and increasing conformity or rotational constraint in mobile-bearing design knee prostheses does not affect knee kinematics adversely, at least under closed chain knee extension conditions in vitro.  相似文献   

4.
Rotating platform mobile bearing knee implants allow for increased tibiofemoral articular conformity without restricting axial rotation. In the current study, the effect of rotating platform knee replacement with and without posterior cruciate ligament substitution on knee kinematics was investigated. Five knees were implanted sequentially implanted with standard (fixed) bearings and then with rotating platform prostheses, each in posterior cruciate retaining and substituting designs. Three-dimensional kinematics for all knees were measured in an Oxford Knee Rig, which simulates dynamic quadriceps-driven closed kinetic chain knee extension under load. Rotating bearings did not significantly change knee kinematics when compared with fixed bearings. In this in vitro model, the cruciate retaining designs stayed more anterior, and had greater net femoral roll back and tibiofemoral valgus angulation with flexion than cruciate substituting designs.  相似文献   

5.
A change in hamstring strength and activation is typically seen after injuries or invasive surgeries such as anterior cruciate reconstruction or total knee replacement. While many studies have investigated the influence of isometric increases in hamstring load on knee joint kinematics, few have quantified the change in kinematics due to a variation in medial to lateral hamstring force ratio. This study examined the changes in knee joint kinematics on eight cadaveric knees during an open‐chain deep knee bend for six different loading configurations: five loaded hamstring configurations that varied the ratio of a total load of 175 N between the semimembranosus and biceps femoris and one with no loads on the hamstring. The anterior–posterior translation of the medial and lateral femoral condyles’ lowest points along proximal‐distal axis of the tibia, the axial rotation of the tibia, and the quadriceps load were measured at each flexion angle. Unloading the hamstring shifted the medial and lateral lowest points posteriorly and increased tibial internal rotation. The influence of unloading hamstrings on quadriceps load was small in early flexion and increased with knee flexion. The loading configuration with the highest lateral hamstrings force resulted in the most posterior translation of the medial lowest point, most anterior translation of the lateral lowest point, and the highest tibial external rotation of the five loading configurations. As the medial hamstring force ratio increased, the medial lowest point shifted anteriorly, the lateral lowest point shifted posteriorly, and the tibia rotated more internally. The results of this study, demonstrate that variation in medial‐lateral hamstrings force and force ratio influence tibiofemoral transverse kinematics and quadriceps loads required to extend the knee. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1707–1715, 2016.  相似文献   

6.
Six knees from cadavers were tested for change in stability after release of the medial collateral ligament with posterior cruciate-retaining and substituting total knee replacements. Load deformation curves of the joint were recorded in full extension and 30 degrees, 60 degrees, and 90 degrees flexion under a 10 N-m varus and valgus torque, 1.5 N-m internal and external rotational torque, and a 35 N anterior and posterior force to test stability in each knee. The intact specimen and posterior cruciate ligament-retaining total joint replacement were tested for baseline comparisons. The superficial medial collateral ligament was released, followed by release of the posterior cruciate ligament. The knee then was converted to a posterior-stabilized implant. After medial collateral ligament release, valgus laxity was statistically significantly greater at 30 degrees, 60 degrees, and 90 degrees flexion after posterior cruciate ligament sacrifice than it was when the posterior cruciate ligament was retained. The posterior-stabilizing post added little to varus and valgus stability. Small, but significant, differences were seen in internal and external rotation before and after posterior cruciate ligament sacrifice. The posterior-stabilized total knee arthroplasty was even more rotationally constrained in full extension than the knee with intact medial collateral ligament and posterior cruciate ligament.  相似文献   

7.
Bi‐cruciate retaining (BCR) total knee arthroplasty (TKA) design preserves both anterior and posterior cruciate ligaments with the potential to restore normal posterior femoral rollback and joint kinematics. Abnormal knee kinematics and “paradoxical” anterior femoral translation in conventional TKA designs have been suggested as potential causes of patient dissatisfaction. However, there is a paucity of data on the in vivo kinematics and articular contact behavior of BCR‐TKA. This study aimed to investigate in vivo kinematics, articular contact position, and pivot point location of the BCR‐TKA during gait. In vivo kinematics of 30 patients with unilateral BCR‐TKA during treadmill walking was determined using validated dual fluoroscopic imaging tracking technique. The BCR‐TKA exhibited less extension than the normal healthy knee between heel strike and 48% of gait cycle. Although the average external rotation trend observed for BCR TKA was similar to the normal healthy knee, the range of motion was not fully comparable. The lowest point of the medial condyle showed longer anteroposterior translation excursion than the lateral condyle, leading to a lateral‐pivoting pattern in 60% of BCR TKA patients during stance phase. BCR‐TKA demonstrated no statistical significant differences in anterior–posterior translation as well as varus rotation, when compared to normal healthy knees during the stance phase. However, sagittal plane motion and tibiofemoral articular contact characteristics including pivoting patterns were not fully restored in BCR TKA patients during gait, suggesting that BCR TKA does not restore native tibiofemoral articular contact kinematics. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1929–1937, 2019  相似文献   

8.
ABSTRACT: BACKGROUND: Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. METHODS: We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. RESULTS: During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. CONCLUSIONS: Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding.  相似文献   

9.
Joint stability is a primary concern in total knee joint replacement. The GMK Sphere prosthesis was specifically designed to provide medial compartment anterior–posterior (A–P) stability, while permitting rotational freedom of the joint through a flat lateral tibial surface. The objective of this study was to establish the changes in joint kinematics introduced by the GMK Sphere prosthesis during gait activities in comparison to conventional posterior‐stabilized (PS) fixed‐bearing and ultra‐congruent (UC) mobile‐bearing geometries. The A–P translation and internal/external rotation of three cohorts, each with 10 good outcome subjects (2.9 ± 1.6 years postop), with a GMK Sphere, GMK PS or GMK UC implant were analysed throughout complete cycles of gait activities using dynamic videofluoroscopy. The GMK Sphere showed the smallest range of medial compartment A–P translation for level walking, downhill walking, and stair descent (3.6 ± 0.9 mm, 3.1 ± 0.8 mm, 3.9 ± 1.3 mm), followed by the GMK UC (5.7 ± 1.0 mm, 8.0 ± 1.7 mm, 8.7 ± 1.9 mm) and the GMK PS (10.3 ± 2.2 mm, 10.1 ± 2.6 mm, 11.6 ± 1.6 mm) geometries. The GMK Sphere exhibited the largest range of lateral compartment A–P translation (12.1 ± 2.2 mm), and the largest range of tibial internal/external rotation (13.2 ± 2.2°), both during stair descent. This study has shown that the GMK Sphere clearly restricts A–P motion of the medial condyle during gait activities while still allowing a large range of axial rotation. The additional comparison against the conventional GMK PS and UC geometries, not only demonstrates that implant geometry is a key factor in governing tibio‐femoral kinematics, but also that the geometry itself probably plays a more dominant role for joint movement than the type of gait activity. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 37:2337–2347, 2019  相似文献   

10.
Complications of the patellofemoral (PF) joint remain a common cause for revision of total knee replacements. PF complications, such as patellar maltracking, subluxation, and implant failure, have been linked to femoral and patellar component alignment. In this study, a dynamic finite element model of an implanted PF joint was applied in conjunction with a probabilistic simulation to establish relationships between alignment parameters and PF kinematics, contact mechanics, and internal stresses. Both traditional sensitivity analysis and a coupled probabilistic and principal component analysis approach were applied to characterize relationships between implant alignment and resulting joint mechanics. Critical alignment parameters, and combinations of parameters, affecting PF mechanics were identified for three patellar designs (dome, modified dome, and anatomic). Femoral internal–external (I‐E) alignment was identified as a critical alignment factor for all component designs, influencing medial–lateral contact force and anterior–posterior translation. The anatomic design was sensitive to patellar flexion–extension (F‐E) alignment, while the dome, as expected, was less influenced by rotational alignment, and more by translational position. The modified dome was sensitive to a combination of superior–inferior, F‐E, and I‐E alignments. Understanding the relationships and design‐specific dependencies between alignment parameters can aid preoperative planning, and help focus instrumentation design on those alignment parameters of primary concern. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:1167–1175, 2012  相似文献   

11.
Increased‐congruency bearing options are widely available in numerous total knee replacement (TKR) systems, with the intended purpose of compensating for posterior‐cruciate ligament (PCL) deficiency. However, their ability to provide adequate stability in this setting has been debated. This in vitro joint simulator study measured changes in knee joint kinematics and stability during passive flexion–extension motions and simulated activities of daily living resulting from TKR with condylar‐stabilized (CS) TKR without a PCL versus cruciate‐retaining (CR) TKR. During passive flexion, the CS TKR resulted in a more posterior tibial positioning than both the intact joint and CR TKR (by 3.4 ± 1.0 mm and 4.8 ± 0.7 mm, respectively). With a posterior tibial force applied, the CS TKR tibia was again significantly more posterior than that of the intact joint and CR TKR (by 4.7 ± 1.3 mm and 5.6 ± 0.8 mm, respectively). Furthermore, there were significant differences in the anterior/posterior kinematics of both TKR with respect to intact knees during gait, and differences between the CS and CR TKR during stair ascent and descent. Overall, there appears to be a reduction in anterior–posterior stability of the PCL‐deficient CS TKR knee, suggesting that contemporary increased‐congruency bearing surface designs may not adequately compensate for the loss of the PCL. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2172–2181, 2019  相似文献   

12.
Medial unicompartmental knee arthroplasty (UKA) is an accepted treatment for isolated medial osteoarthritis. However, using an improper thickness for the tibial component may contribute to early failure of the prosthesis or disease progression in the unreplaced lateral compartment. Little is known of the effect of insert thickness on both knee kinematics and ligament forces. Therefore, a computational model of the tibiofemoral joint was used to determine how non‐conforming, fixed bearing medial UKA affects tibiofemoral kinematics, and tension in the medial collateral ligament (MCL) and the anterior cruciate ligament (ACL) during passive knee flexion. Fixed bearing medial UKA could not maintain the medial pivoting that occurred in the intact knee from 0° to 30° of passive flexion. Abnormal anterior–posterior (AP) translations of the femoral condyles relative to the tibia delayed coupled internal tibial rotation, which occurred in the intact knee from 0° to 30° of flexion, but occurred from 30° to 90° of flexion following UKA. Increasing or decreasing tibial insert thickness following medial UKA also failed to restore the medial pivoting behavior of the intact knee despite modulating MCL and ACL forces. Reduced AP constraint in non‐conforming medial UKA relative to the intact knee leads to abnormal condylar translations regardless of insert thickness even with intact cruciate and collateral ligaments. This finding suggests that the conformity of the medial compartment as driven by the medial meniscus and articular morphology plays an important role in controlling AP condylar translations in the intact tibiofemoral joint during passive flexion. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1868–1875, 2018.
  相似文献   

13.
Tibiofemoral compression causes circumferential tension in the knee meniscus, which is transferred to the tibial bone at the anterior and posterior attachments. The objective of the study was to measure the resulting tensile forces at the horn attachment in a porcine model. The anterior horn attachment of the porcine medial meniscus (n = 10) was separated from the surrounding bone with a core reamer. A force transducer was installed such that tensile forces acting upon the now mobile horn attachment could be measured. The tibiofemoral joint was loaded in compression, starting at a preload of 30 N, with three 150‐N increments, giving 180, 330, and 480 N load. Flexion angles of 0, 30, and 60° were investigated. The average resultant tension at the horn attachment was 26.3, 40.6, and 55.4 N with full extension, 29.2, 47.8, and 62.2 N at 30° flexion and 30.1, 49.6, and 68.1 N at 60° flexion. The tibiofemoral compression had a significant effect on the tension (p < 0.001), whereas no influence of the flexion angle was found (p = 0.291). The study demonstrates that tibiofemoral compressive loads cause considerable tensile forces at the anterior meniscal horn attachment. The data are of interest for models of the repair or replacement of the knee menisci. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:1619–1624, 2009  相似文献   

14.
The mechanism underlying non‐contact anterior cruciate ligament (ACL) injury is multi‐factorial and still an object of debate. Computational models, in combination with in vivo and cadaveric studies, can provide valuable insight into the contribution of the different factors involved. The goal of this study was to validate four knee finite element models (two males and two females) to kinematic and strain data collected in vitro with an impact‐driven simulator and use them to assess how secondary external knee loads (knee abduction moment [KAM], anterior shear force, and internal rotation torque [ITR]) affect tibiofemoral contact forces and ACL force during impact. Four subject‐specific knee models were developed from specimen computed tomography and magnetic resonance imaging. Patellofemoral and tibiofemoral ligament properties were calibrated to match experimentally measured kinematics and ligament strain. Average root mean square errors and correlations between experimental and model‐predicted knee kinematics were below 1.5 mm and 2°, and above 0.75, respectively. Similar errors and correlations were obtained for ACL strain (< 2% and > 0.9). Model‐predicted ACL forces were highly correlated with the anterior component of the tibiofemoral contact force on the lateral plateau occurring during impact (r = 0.99), which was increased by larger KAM and ITR through the posterior tibial slope and a larger contact force on the lateral side. This study provides a better understanding of the mechanism through which secondary external knee loads increase ACL injury risk during landing. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1730–1742, 2019  相似文献   

15.
The posterolateral corner (PLC) structures including the popliteofibular ligament (PFL), popliteus tendon (PT) and lateral collateral ligament (LCL) are important soft tissues for posterior translational, external rotational, and varus angulation knee joint instabilities. The purpose of this study was to determine the effects of deficient PLC structures on the kinematics of the knee joint under gait and squat loading conditions. We developed subject‐specific computational models with full 12‐degree‐of‐freedom tibiofemoral and patellofemoral joints for four male subjects and one female subject. The subject‐specific knee joint models were validated with computationally predicted muscle activation, electromyography data, and experimental data from previous study. According to our results, deficiency of the PFL did not significantly influence knee joint kinematics compared to an intact model under gait loading conditions. Compared with an intact model under gait and squat loading conditions, deficiency of the PT led to significant increases in external rotation and posterior translation, while LCL deficiency increased varus angulation. Deficiency of all PLC structures led to the greatest increases in external rotation, varus angulation, and posterior translation. These results suggest that the PT is an important structure for external rotation and posterior translation, while the LCL is important for varus angulation under dynamic loading conditions. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2202–2209, 2018.
  相似文献   

16.
This study sought to determine the similarities between features of calculated stress-shielding and observed bone loss in the distal femur after total knee replacement. Stress-shielding was determined by comparing the magnitudes and distributions of strain energy density, calculated using three-dimensional finite element models of the intact bone, the bone after total knee replacement with bonding assumed at all prosthesis-bone interfaces, and the bone after total knee replacement with bonding assumed only at the distal interface. The loading condition simulated static lifting with the knee flexed at 45°, producing tibiofemoral and patellofemoral joint reactions of 900 and 450 N, respectively. The maximum magnitudes of strain energy density calculated using the total knee replacement models were less than 15% of the corresponding magnitudes from the intact bone model. The greatest difference was found to occur at the anterior distal corner of the femur, suggesting this location as the one most vulnerable to stress-shielding. Clinically observed bone loss after total knee replacement frequently occurs at this location. At the anterior distal corner, the calculated magnitudes for the two total knee replacement models were similar, suggesting that stress-shielding at this location was not reduced by limiting fixation only to the distal interface. Although the study corresponded to one loading condition and one geometry of the total knee replacement femoral component with the inherent limitations of model calculations, the results suggest a possible scenario for stress-shielding.  相似文献   

17.
Functional load transmission and kinematic performance were compared for standard versus posterior-stabilized versions of a rotating-platform total knee implant, over a standardized loading cycle, using three-dimensional contact finite element analysis. These two design variants differ primarily in terms of the latter's polyethylene insert having a cam that engages with the femoral component during appreciable flexion, thereby inducing femoral component rollback. The finite element model, previously validated experimentally, afforded direct comparisons of anterior lift-off of the insert from the tibial tray, of bearing mobility (insert rotation about the pivot post), of femoral rollback, and of metal-on-polyethylene contact stresses at the bearing and backside surfaces of the insert. Both design variants generally performed comparably, exhibiting an internal and external rotation range of approximately 5 degrees, approximately 1.5 mm peak lift-off at the anterior aspect of the insert, and approximately 15 mm of posterior rollback, the respective maxima for both designs occurring at approximately the same instants in the gait cycle. However, the posterior-stabilized design had slightly more rollback, and slightly less anterior lift-off and rotation, than did the standard rotating-platform design. Peak polyethylene stresses occurred on the backside of the insert near the posterior edge of the medial compartment, the magnitude being approximately 18% higher for the posterior-stabilized design (21 MPa) than for the standard design.  相似文献   

18.
Accurate knowledge of knee joint motion is needed to evaluate the effects of implant design on functional performance and component wear. We conducted a randomized controlled trial to measure and compare 6-degree-of-freedom (6-DOF) kinematics and femoral condylar motion of posterior-stabilized (PS), cruciate-retaining (CR), and medial-stabilized (MS) knee implant designs for one cycle of walking. A mobile biplane X-ray imaging system was used to accurately measure 6-DOF tibiofemoral motion as patients implanted with PS (n = 23), CR (n = 25), or MS (n = 26) knees walked over ground at their self-selected speeds. Knee flexion angle did not differ significantly between the three designs. Relative movements of the femoral and tibial components were generally similar for PS and CR with significant differences observed only for anterior tibial drawer. Knee kinematic profiles measured for MS were appreciably different: external rotation and abduction of the tibia were increased while peak-to-peak anterior drawer was significantly reduced for MS compared with PS and CR. Anterior-posterior drawer and medial-lateral shift of the tibia were strongly coupled to internal-external rotation for MS, as was anterior-posterior translation of the contact center in the lateral compartment. MS exhibited the least amount of paradoxical anterior translation of the femur relative to the tibia during knee flexion. The joint center of rotation in the transverse plane was located in the lateral compartment for PS and CR and in the medial compartment for MS. Substantial differences were evident in 6-DOF knee kinematics between the healthy knee and all three prosthetic designs. Overall, knee kinematic profiles observed for MS resemble those of the healthy joint more closely than PS and CR.  相似文献   

19.
《The Journal of arthroplasty》2020,35(11):3289-3299
BackgroundMathematical modeling is among the most common computational tools for assessing total knee arthroplasty (TKA) mechanics of different implant designs and surgical alignments. The main objective of this study is to describe and validate a forward solution mathematical of the knee joint to investigate the effects of TKA design and surgical conditions on TKA outcomes.MethodsA 12-degree of freedom mathematical model of the human knee was developed. This model includes the whole lower extremity of the human body and comprises major muscles and ligaments at the knee joint. The muscle forces are computed using a proportional–integral–derivative controller, and the joint forces are calculated using a contact detection algorithm. The model was validated using telemetric implants and fluoroscopy, and the sensitivity analyses were performed to determine how sensitive the model is to both implant design, which was analyzed by varying medial conformity of the polyethylene, and surgical alignment, which was analyzed by varying the posterior tibial tilt.ResultsThe model predicted the tibiofemoral joint forces with an average accuracy of 0.14× body weight (BW), 0.13× BW, and 0.17× BW root-mean-square errors for lateral, medial, and total tibiofemoral contact forces. With fluoroscopy, the kinematics were validated with an average accuracy of 0.44 mm, 0.62 mm, and 0.77 root-mean-square errors for lateral anteroposterior position, medial anteroposterior position, and axial rotation, respectively. Increasing medial conformity resulted in reducing the paradoxical anterior sliding midflexion. Furthermore, increasing posterior tibial slopes shifted the femoral contact point more posterior on the bearing and reduced the tension in the posterior cruciate ligament.ConclusionA forward solution dynamics model of the knee joint was developed and validated using telemetry devices and fluoroscopy data. The results of this study suggest that a validated mathematical model can be used to predict the effects of component design and surgical conditions on TKA outcomes.  相似文献   

20.
In total knee replacement, the investigation on the exact contact patterns at the post‐cam in implanted patients from real in vivo data during daily living activities is fundamental for validating implant design concepts and assessing relevant performances. This study is aimed at verifying the restoration of natural tibio‐femoral condylar kinematics by investigating the post‐cam engagement at different motor tasks. An innovative validated technique, combining three‐dimensional fluoroscopic and finite element analyses, was applied to measure joint kinematics during daily living activities in 15 patients implanted with guided motion posterior‐stabilized total knee replacement. Motion results showed physiological antero‐posterior translations of the tibio‐femoral condyles for every motor task. However, high variability was observed in the position of the calculated pivot point among different patients and different motor tasks, as well as in the range of post‐cam engagement. Physiological tibio‐femoral joint rotations and contacts at the condyles were found restored in the present knee replacement. Articular contact patterns experienced at the post‐cam were found compatible with this original prosthesis design. The present study reports replaced knee kinematics also in terms of articular surface contacts, both at the condyles and, for the first time, at the post‐cam. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1396–1403, 2017.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号