首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.

Purpose

The objective of this retrospective study was to evaluate the functional results of distal biceps tendon repair using suture anchors via a single-incision approach.

Methods

Forty-nine patients were re-examined at a mean follow-up of 44.2 ± 32.1 months (range, 12–119 months). Subjective and objective criteria included patient’s satisfaction, active range of motion (ROM), maximum isometric strength in flexion (at 45° and 90°), and supination of both arms. Functional scoring included the Morrey elbow score (MES) and the QuickDASH. Furthermore, follow-up radiographs were performed.

Results

Eighty-six percent of patients were highly satisfied or satisfied with their outcome. Compared to contralateral, the active ROM of elbow flexion, extension, and pronation was not affected; however, supination was decreased by 3° (P < 0.001). The isometric maximum strengths showed significant deficits in all tested scenarios (at 45°, P = 0.002; at 90°, P < 0.001; for supination, P < 0.001). The MES and the QuickDASH were 97.2 ± 4.9 and 7.9 ± 13.9, respectively. Heterotopic ossifications (HO) were found in 39 % of patients; however, with respect to scores and strength, no significant differences were seen compared to patients without HO. Moreover, four anchor failures were detected.

Conclusions

Single-incision suture anchor repair provides high patient’s satisfaction and good results with respect to ROM and functional scoring. Nevertheless, based on presented data, the patient has to be informed of postoperative HO and especially for supination strength weakness after surgery. Distal biceps tendon repair should be reserved for experienced upper extremity surgeons to avoid procedure-related complications.  相似文献   

2.

Purpose

Component orientations and positions in total hip arthroplasty (THA) are important parameters in restoring hip function. However, measurements using plain radiographs and 2D computed tomography (CT) slices are affected by patient position during imaging. This study used 3D CT to determine whether contemporary THA restores native hip geometry.

Methods

Fourteen patients with unilateral THA underwent CT scan for 3D hip reconstruction. Hip models of the nonoperated side were mirrored with the implanted side to quantify the differences in hip geometry between sides.

Results

The study demonstrated that combined hip anteversion (sum of acetabular and femoral anteversion) and vertical hip offset significantly increased by 25.3° ± 29.3° (range, −25.7° to 55.9°, p = 0.003) and 4.1 ± 4.7 mm (range, −7.1 to 9.8 mm, p = 0.009) in THAs.

Conclusions

These data suggest that hip anatomy is not fully restored following THA compared with the contralateral native hip.  相似文献   

3.

Purpose

Mechanical properties of a locking attachment plate construct (LAP-LCP), allowing bicortical screw placement laterally to the prosthesis stem, are compared to a cerclage-LCP construct.

Methods

Eight right synthetic femora with implanted uncemented hip endoprosthesis were cut distally and fixed with LCP, monocortical locking screws and either LAP (n = 4) or cerclage (n = 4). Cyclic testing was performed with monotonically increasing sinusoidal load until failure. Relative movements at the plate–femur interface were registered by motion tracking. Statistical differences were detected by unpaired t-test and general linear model repeated measures.

Results

Stiffness of the LAP-LCP was significantly higher at the beginning (875.4 N/mm ± 29.8) and after 5000 cycles (1213.0 N/mm ± 101.1) compared to the cerclage-LCP (644.96 N/mm ± 50.1 and 851.9 N/mm ± 81.9), with p = 0.013. Relative movements for AP-bending (B) and axial translation (T) of the LAP-LCP at the beginning (0.07° ± 0.02, 0.20 mm ± 0.08), after 500 cycles (0.16° ± 0.10, 0.26 mm ± 0.07) and after 5000 cycles (0.26° ± 0.11, 0.31 mm ± 0.07) differed significantly from the cerclage-LCP (beg.: 0.26° ± 0.04, 0.28 mm ± 0.05; 500 cyc: 0.47° ± 0.03, 0.53 mm ± 0.07; 5000 cyc.: 0.63° ± 0.18, 0.79 mm ± 0.13), with B: p = 0.02, T: p = 0.04. Relative movements for medial bending were not significantly different between the two constructs. Cycles to failure (criterion 1 mm axial translation) differed significantly between LAP-LCP (19,519 ± 1,758) and cerclage-LCP (11,265 ± 2,472), with p = 0.035.

Conclusions

Biomechanically, the LAP-LCP construct improves proximal fixation of periprosthetic fractures compared to the cerclage-LCP construct.  相似文献   

4.
5.

Purpose

Extensive glenoid bone loss after failed shoulder arthroplasty represents a challenge for revision arthroplasty. Treatment options vary widely and have been a source of controversy among experts.

Methods

Between 2004 and 2010, a total of 17 patients underwent glenoid reconstruction surgery using an autologous iliac crest bone graft and secondary revision arthroplasty due to extensive glenoid bone loss after failed previous total shoulder arthroplasty. The outcomes were assessed by means of clinical examination, Constant score, and bi-plane radiography as well as pre-, postoperative and follow-up CT.

Results

Before the revision surgery, the mean Constant score was 24 ± 17 and improved to 40 ± 13 after the glenoid rebuilding and revision arthroplasty. CT imaging revealed adequate glenoid bone stock restoration with no relevant graft resorption or loosening of the glenoid. The average postoperative antero-posterior diameter of the glenoid was 28 ± 3 mm which had decreased to 25 ± 3 mm at follow-up. The average postoperative version of the glenoid was 95.7° ± 6° and had decreased to 98.5° ± 4° at follow-up. Both the glenoid version and diameter had changed significantly (P < 0.001) comparing postoperative and follow-up CT-scans.

Conclusion

Glenoid reconstruction surgery using an iliac crest bone-block autograft prior to revision arthroplasty represents a valuable salvage procedure in cases of extensive glenoid bone loss after primary shoulder arthroplasty. Sufficient glenoid bone stock restoration is indispensable for reliable fixation of glenoid components and in turn a satisfactory clinical outcome.  相似文献   

6.

Purpose

The purpose of this study was to assess the MRI features of the all-inside repaired meniscus in the long-term.

Methods

Among 27 consecutive all-inside arthroscopic meniscal repairs, 23 patients aged 25 ± 5 years at the time of surgery were reviewed at a median follow-up of 10 ± 1 years. Retrospective clinical examinations and imaging assessments using a 1.5-T MRI after all-inside arthroscopic meniscal repair were conducted.

Results

At follow-up, Lysholm and IKDC averaged 89 ± 11 and 95 ± 8, respectively. MRI examinations revealed no meniscal signal alteration in three patients (13 %), a vertical signal located in the previously torn area in seven (30 %), a horizontal grade 3 in nine (39 %), and a complex tear (grade 4) in four (17.5 %). There were no differences between medial and lateral menisci (p = 0.15), stable and stabilised knees (p = 0.56).

Conclusions

Several abnormal vertical and/or horizontal hypersignals are still present on MRI examination ten years after arthroscopic all-inside meniscal repair. The appearance of early signs of osteoarthritis is rare, suggesting a chondroprotective effect of the repaired meniscus.  相似文献   

7.

Purpose

Press-fit cementless radial head implant longevity relies on adequate bone ingrowth. Failed implant osseointegration remains a clinical concern and has been shown to lead to prosthetic failure. The purpose of this study was to test the hypothesis that implants with sufficient initial press-fit stability would be less likely to fail due to implant pull-out, as demonstrated by an increasing amount of energy required to remove the prosthesis from the canal.

Methods

Ten cadaveric radii were implanted with five sizes (6–10 mm in 1-mm increments) of grit-blasted, cementless radial head stems. A customised slap hammer was used to measure the energy required to remove each stem. Stem-bone micromotion was also measured.

Results

The suboptimally sized stem (Max − 1) (i.e. 1 mm undersized) required less energy (0.5 ± 0 J) to pull out than the optimally sized stem (Max) (1.7 ± 0.3 J) (p = 0.008). The optimally sized stem demonstrated greater initial stability (45 ± 7 μm) than the suboptimally sized stem (79 ± 12 μm) (p = 0.004).

Conclusions

This investigation demonstrates the importance of obtaining adequate press-fit stability for the prevention of radial head stem pull-out failure. These data add to the relatively scant knowledge in the literature regarding radial head biomechanics. The energy required to remove a prosthetic radial head ingrowth stem decreases in conjunction with diameter. The use of an inadequately sized stem increases the stem’s micromotion as well as the risk of prosthetic loosening due to pull-out.  相似文献   

8.

Purpose

Tibial nail interlocking screw failure often occurs during delayed fracture consolidation or at early weight bearing of nailed unstable fractures, in general when high implant stress could not be reduced by other means. Is there a biomechanical improvement in long-term performance of angle stable locking screws compared to conventional locking screws for distal locking of intramedullary tibial nails?

Methods

Surrogate bones of human tibiae were cut in the distal third and distal locking of the 10 mm intramedullary tibial nail was performed with either two angle stable locking screws or two conventional locking screws in the mediolateral plane. Six specimens per group were mechanically tested under quasi-static and cyclic axial loading with constantly increasing force.

Results

Angle stable locking screw constructs exhibited significantly higher stiffness values (7,809 N/mm ± 647, mean ± SD) than conventional locking screw constructs (6,614 N/mm ± 859, p = 0.025). Angle stable locking screw constructs provided a longer fatigue life, expressed in a significantly higher number of cycles to failure (187,200 ± 18,100) compared to conventional locking screw constructs (128,700 ± 7,000, p = 0.004).

Conclusion

Fatigue performance of locking screws can be ameliorated by the use of angle stable locking screws, being especially important if the nail acts as load carrier and an improved stability during fracture healing is needed.  相似文献   

9.

Purpose

Trochleoplasty is a relatively rare operation with few published results and it remains a technically demanding procedure which requires careful patient selection. The ideal candidate for surgery remains to be elucidated, and some authors consider it as a good revision option in cases of previous unsuccessful operations for persisting patellar dislocation with underlying trochlear dysplasia. The purpose of this study is to record the results from the application of sulcus-deepening trochleoplasty in patients with trochlear dysplasia and previous unsuccessful surgery for patellar dislocation.

Methods

Twenty-two patients (24 knees) were operated upon during the period 9/1993–9/2006; they had undergone surgery for patellofemoral instability and had persistent patellar dislocation, and were followed-up for a mean of 66 months (24–191). Trochleoplasty was performed in all patients using the same technique and rehabilitation protocol. Additional soft-tissue and bony operations were performed in every case.

Results

Of all cases, 29.1 % had type B and 70.9 % had type D trochlear dysplasia. After trochleoplasty, no patient had a patellar re-dislocation up to the last follow-up. Pain decreased in 72 % and the apprehension sign was negative in 75 % of the cases (p < 0.01). Sulcus angle decreased from 153° ± 14° to 141° ± 10° (p < 0.01), TT-TG distance decreased from 16 ± 6 mm to 12 ± 2 mm (p < 0.001), and patellar tilt decreased from 31° ± 14° to 11° ± 8° (p < 0.0001). Mean pre-operative Kujala score was 44 (25–73) and at the latest follow-up it increased to 81 (53–100), (p < 0.001). At the time of final follow-up, there was no case of patellofemoral arthritis.

Conclusions

Trochlear dysplasia is a key factor in the treatment of recurrent patellar dislocation and its correction could be included in the surgical options. Sulcus-deepening trochleoplasty is an acceptable revision option for the surgical treatment of patients with persisting patellar dislocation and high-grade trochlear dysplasia.  相似文献   

10.

Purpose

The purpose of this study was to evaluate the clinical outcomes regarding the dorsal wedge osteotomy fixed using a polyblend suture and describe the usefulness of this fixation method for the treatment of Freiberg disease.

Methods

The subjects consisted of 13 feet from 13 cases suffering from Freiberg disease that underwent extra-articular dorsal closing-wedge osteotomy using a polyblend suture. The average age was 31.7 (range 13–72) years. The average follow-up period was 17 (range 14–24) months. Regarding image findings, time to bone union and metatarsal shortening was reviewed. The investigation was carried out using the range of motion (ROM), visual analog scale (VAS), and Japanese Society of the Surgery of Foot lesser toe scale (JSSF score) in the MTP joint before surgery and at the latest follow-up.

Results

Calluses under the metatarsal head were not observed in any cases. The mean metatarsal shortening was 2.33 ± 2.07 mm at follow-up. The bone union required an average of 8.4 ± 0.8 weeks. The average ROM of dorsal flexion improved from 37.2 ± 5.3° before surgery to 73.6 ± 9.9° at latest follow-up (p < 0.0001). The average ROM of plantar flexion improved from 16.0 ± 10.1° before surgery to 19.5 ± 8.6° at latest follow-up (p = 0.35). The average VAS significantly improved from 75.3 ± 8.5 before surgery to 4.9 ± 4.2 at latest follow-up (p < 0.0001). The average JSSF score significantly improved from 67.3 ± 9.4 points before surgery to 98.8 ± 3.0 points at the latest follow-up (p < 0.0001).

Conclusion

Extra-articular dorsal closing-wedge osteotomy using a polyblend suture was carried out to treat Freiberg disease. The bone union was observed in all cases with improved clinical results. Fixation using a polyblend suture was considered to be useful.  相似文献   

11.

Purpose

An anatomical supra-condylar plate is designed and analysed by biomechanical testing.

Methods

The biomechanical properties of the supra-condylar and condylar plate were compared in six matched pairs of cadaveric femurs. A transverse osteotomy gap was created to simulate an OTA/AO type A3 supracondylar fracture. The left and right specimens were fitted with supra-condylar and condylar plate, respectively. Nondestructive axial compression, three-point bending and torsion tests were performed, and the peak load of the bone-implant construction was measured. The fracture site suitable for supra-condylar plate application and its correlation with femoral length were calculated. The gender influence on it was also discussed.

Results

The difference of stiffness between the supra-condylar and condyle groups were not significant (P > 0.05) at 363.4 and 362.5 N/mm for compression, 229.5 and 237.6 N/mm in the sagittal plane and 195.5 and 188.4 N/mm in the coronal plane for three-point bending, and 7.5 and 7.9 Nm/deg for axial torsion, respectively. The peak load was 4438 ± 136.15 N and 5215 ± 174.33 N, respectively, for the two groups. The average extent of the fracture site suitable for the application of the supra-condylar plate was 70.86 ± 4.61 mm. The femoral length and gender showed no influence on it.

Conclusion

Despite the limited bone contact area provided by the supra-condylar plate, its construct stiffness is comparable to the condylar plate. The supra-condylar plate can be used to treat carefully-selected extra-articular supracondylar fractures.  相似文献   

12.

Purpose

Knee pain after total knee arthroplasty may be caused by an unresurfaced patella. Secondary isolated resurfacing of the previously unresurfaced patella in total knee arthroplasty remains controversial. The aim of this retrospective study was to evaluate the outcome after patellar resurfacing as a second stage procedure.

Methods

The study included 22 patients (13 female/nine male) who underwent resurfacing of the patella with a mean follow-up of 61.8 ± 39.2 months. The mean age of the patients was 60 ± 9.7 years at the time of operation. The average period between total knee arthroplasty and patellar resurfacing was 26.3 ± 15.2 months. The patient’s subjective satisfaction was assessed by a custom-made questionnaire.

Results

The mean Knee Society Score improved significantly from 60.1 ± 8.3 to 77.0 ± 6.3 (p = 0.0063). The mean functional score also improved significantly from 42.7 ± 2.3 to 60.2 ± 3.9 (p = 0.001). Three patients (13.6%) needed further operative revision.

Conclusions

Although clinical scores showed significant improvement some patients continued to have pain and remained dissatisfied without detecting a specific reason. Further studies are needed to better elucidate the benefit of patellar resurfacing as second stage procedure.  相似文献   

13.

Purpose

The aim of this study was to evaluate laxity in knees with pre-operative (preop) valgus alignment compared to knees with pre-operative varus alignment after total knee arthroplasty (TKA).

Methods

This was a retrospective study including 81 patients, with six years follow-up, for pre-operative valgus- or varus alignment of the leg. All patients had been supplied with the same cruciate retaining (CR) TKA with rotating platform. Clinical findings were assessed by KSS, OKS and IKDC 2000 score. Rotational knee laxity was evaluated by a validated instrument (Laxitester®) with 2 Nm torque in 30° flexion. Collateral ligament laxity was tested manually in 30° flexion with a bending moment of approximately 5 Nm. Biomechanical results were compared to the contralateral side.

Results

Thirty-one patients had a preop valgus alignment of 8.96° and 50 patients a varus leg axis of 4.99° in the mean. In the preop valgus knees rotational analysis showed an increased laxity of 10.7° compared to preop varus knees (p = 0.001). There was no significant difference in medial (valgus 2.6 mm, varus 2.5 mm) and lateral (valgus 2.8 mm, varus 2.7 mm) laxity. KSS and OKS showed no significant differences in the follow-up results. In the IKDC 2000 objective score 50 % of the preop varus knees and 25.8 % of the preop valgus knees were classified as nearly normal. The difference in the IKDC objective was highly significant (p < 0.001).

Conclusion

Preop valgus knees show a significantly increased rotational laxity but no increased collateral ligament laxity compared to pre-operative varus knees six years after TKA with rotating platform. There is a significant difference in IKDC objective.  相似文献   

14.

Purpose

The aim of this study was to assess the stability of the glycosaminoglycan (GAG) content in the long term after matrix-associated autologous chondrocyte transplantation (MACT) with Hyalograft C in the knee over a follow-up period of one year.

Methods

In this cross-sectional evaluation, 11 patients after MACT of the knee consented to delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) measurements. The mean post-operative interval before the first MR examination was 40.6 ± 22.0 months, and the second MR examination was carried out after another 12 months. The Lysholm score was assessed for clinical evaluation. Quantitative T1 measurements after intravenous negatively charged MR contrast agent administration were performed. Global post-contrast T1 of the reference cartilage and the repair tissue and a relative post-contrast T1 value were calculated.

Results

The Lysholm score improved significantly from 59.8 ± 12.9 at baseline to 86.1 ± 15.7 at the second visit (p < 0.01). The mean global T1 of the repair tissue (1st visit 581.3 ± 126.4 ms; 2nd visit 684.1 ± 169.9 ms; p = 0.104) and the mean relative T1 value showed stable results over one year (1st visit 0.81 ± 0.28; 2nd visit 0.76 ± 0.32; p = 0.4).

Conclusions

The study demonstrated stable glycosaminoglycan content of the repair tissue after MACT at midterm.  相似文献   

15.

Purpose

The aim of this study was to compare the results of a new technique for low, multidirectional locked nailing with closed reduction and minimally invasive plating in the treatment of distal tibial metadiaphyseal fractures.

Methods

Forty-six matched patients were divided according to age, gender, Injury Severity Score, and fracture pattern into group A (expert tibial nailing) and group B (minimally invasive plating). Then, the patients were followed up, and the clinical and radiographic results were retrospectively analysed.

Results

The mean followed-up was 24.7 ± 2.7 months in group A and 25.8 ± 2.8 months in group B. No patient had nonunion, shortening, hardware breakdown, or deep-seated infection. Patients in group A had a significantly shorter mean operating time, hospital stay, full weight-bearing time and union time (76 ± 16.6 vs. 90 ± 20.3 minutes, p = 0.000; 5.8 ± 2.1 vs. 8.9 ± 3.1 days, p = 0.000; 9.0 ± 1.4 vs. 11.1 ± 1.7 weeks, p = 0.000; and 21.3 ± 3.5 vs. 23.1 ± 3.6 weeks, p = 0.047, respectively). Three patients in group A and one patient in group B presented with malalignment (p = 0.608). The mean Olerud-Molander Ankle score was 89.0 ± 7.1 in group A and 87.6 ± 8.4 in group B (p = 0.478).

Conclusions

Distal tibia metadiaphyseal fractures may be treated successfully with low, multidirectional locked nails or plates. However, low, multidirectional locked nailing may represent a superior surgical option, since it offers advantages in terms of mean operating time, hospital stay, full weight-bearing time and union time.  相似文献   

16.

Purpose

Primary paraclinical investigation to look for femoral morphological abnormality consistent with cam-type anterior femoroacetabular impingement (FAI) must include specific radiographic projections of the hip from the following: cross-table, frog-leg or Dunn (90° and 45° flexion). We use a frog-leg type view with fixed angles as described by Chiron, obtained with the patient in a supine position, with the hip in 45° flexion-abduction and 30° external rotation. The X-ray beam is anteroposterior and centred on the femoral head. We evaluated this view by comparing it with other views in common use.

Methods

In this experimental study, we created artificial radio-opaque morphological abnormalities secured onto normal femoral necks. The femurs were placed in relation to a fixed pelvis using orthogonal landmarks, in the positions of the various radiographic views. The digital radiographs were analysed by two observers. Nineteen femurs were included to reveal a difference of 5° between the alpha angle of Nötzli et al. [11] measured on the Dunn view and the frog-leg 45/45/30 view (Student’s paired test).

Results

The highest mean values of the alpha angle of Nötzli were always obtained with the frog-leg 45/45/30 view (87.4°, 86.2°, 84.5°) and the lowest with the cross-table view. We found a mean difference of 8.95° with the 90° Dunn view (P = 0.00007), 3.44° with the 45° Dunn view (P = 0.004) and 13.47° with the cross-table view (P = 0.002).

Conclusions

This experimental study confirmed the value of the frog-leg 45/45/30 view in assisting diagnosis of cam-type FAI.  相似文献   

17.

Purpose

The purpose of this study was to present a retrospective comparative overview of the Ilizarov non-free bone plasty techniques of one-stage multilevel fragment lengthening and gradual tibilisation of the fibula used for extensive tibial defect management.

Methods

Extensive tibial defects in 83 patients were managed either by multilevel fragment lengthening (group I, n = 41, mean defect size 13.1 ± 0.9 cm) or gradual tibilisation of the fibula (group II, n = 42, mean defect size 12.5 ± 1.2 cm) using the Ilizarov apparatus. The initial findings, treatment protocols and outcomes of those patients treated within the period 1972–2011 were studied retrospectively by medical records and radiographs, and statistically assessed with Microsoft Excel and Attestat software.

Results

Group I had multilevel fragment lengthening over one stage that averaged 288.0 ± 14.4 days. The mean total period of gradual tibilisation of the fibula in group II was 316.0 ± 29.7 days. The patient’s age in the latter group had an effect on the completeness of leg-length equalisation.

Conclusions

The techniques can be used to manage extensive tibial defects as all the defects bridged, leg-length discrepancy and deformity were corrected and patients were able to load their limbs.  相似文献   

18.

Purpose

This study was designed to evaluate whether the mechanical axis deviation (MAD) of the leg correlates with an increased hip alpha angle as described by Nötzli, which is associated with femoroacetabular impingement (FAI).

Methods

In a retrospective analysis, standing full-length anteroposterior radiographs were analysed in patients who suffered from symptomatic leg alignment. The study included 85 radiographs of 80 patients with an average age of 43.11 years (range 18–60 years). Five patients underwent a bilateral long-leg X-ray examination. All radiographs were transferred as Digital Imaging and Communications in Medicine data files from the Picture Archiving and Communications System into the OrthoPlanner software version 2.3.2. The radiographs were measured by one orthopaedic surgeon and one independent radiologist.

Results

The mean value of the alpha angle of Nötzli was 61.43° (49.07–74.04°). A total of 57 (67 %) radiographs showed a varus deviation, 25 (29.5 %) had a valgus malalignment and three (3.5 %) a straight leg axis. Of 82 radiographs, 40 (48.8 %) had a moderate axis deviation with a MAD <15 or > − 15 mm and a mean alpha angle of 57.81°, and 42 (51.2 %) with extended axis deviation of a MAD > 15 or < − 15 mm had a mean alpha angle of 62.93°; 40 (95.2 %) of these 42 showed an alpha angle > 55°. The alpha angle was significantly increased in extended axis deviation compared to moderate axis deviation (P = 0.001).

Conclusions

This study confirmed that increased alpha angles were found significantly at higher degrees of axis deviation on the full-length radiograph. In cases of a MAD >15 or < − 15 mm and symptomatic coxalgia, diagnostic tests must be pursued for FAI.  相似文献   

19.

Purpose

Bone drilling causes an increase in bone temperature, and a temperature above 47°C is critical because it causes thermal bone necrosis. Thermal osteonecrosis is common with the drill diameter of ≥4.5 mm without cooling. The aim of this study was to determine the increase of bone temperature during drilling using newly contructed two-step and internally cooled drills.

Methods

An experiment was set up according to a central composite design. An internally cooled drill (3.4 mm and 4.5 mm) and a two-step drill (2.5/3.4 and 3.4/4.5 mm) were used in combination with feed rates of (0.02, 0.04, 0.10, 0.16 and 0.18 mm/rev) and cutting speeds (1.18, 10.68, 33.61, 56.55 and 66.05 m/min) with and without cooling with water of 24°C. Bone temperatures were measured with thermocouples. Drilling was performed on pig diaphyses with a three-axis mini milling machine.

Results

Bone temperatures in all combinations of parameters with internal cooling were below the critical 47°C (p = 0.05). The highest temperatures were detected using a 4.5-mm drill (40.5°C). A statistically significant effect other than cooling was found with the drill diameter and feed. A drill diameter of 3.4 mm with internal cooling developed a maximum temperature of 38.5°C and without cooling 46.3°C. For the same conditions a drill with diameter of 4.5 mm reached temperatures of 40.5°C and 55.7°C, respectively. The effect of feed rate is inversely proportional to the increase in bone temperature. With the feed rate 0.16 mm/rev, temperature was below critical even using the 4.5-mm drill (46.4°C, p = 0.05). Using the 3.4-mm drill all temperatures were below critical (46.2°C, p = 0.05). The two-step drill compared to a standard drill with the same diameter did not show statistical differences in maximum bone temperatures for all combinations of parameters (p = 0.05).

Conclusions

A two-step drill does not have any advantages over a standard twist drill of the same diameter. An internally cooled drill causes a significantly smaller increase of bone temperature during drilling with water of 24°C. An internally cooled drill is currently the ''ideal'' drill for traumatology/orthopaedics because it produces the smallest increase in bone drilling temperature. If internal cooling is used the regulation of other drilling parameters is of no importance.  相似文献   

20.

Purpose

Limited data exist for the reconstructive potential of short bone-preserving stems in THA using a minimal invasive posterolateral approach. Our study aim was to assess the effect of stem design on the reconstruction of hip offset and leg length in MIS posterolateral THA.

Methods

This retrospective consecutive single-surgeon study compares hip offset and leg length, as well as acetabular component positioning (cup anteversion; inclination) of 129 THAs with a cementless standard-length stem (Synergy®) and 143 THAs with a cementless short bone-preserving stem (Trilock®).

Results

In reference to the contralateral side, the mean difference in hip offset was 0.9 mm (p = 0.067) for the standard stem and 0.1 mm (p = 0.793) for the short stem, respectively. Leg-length discrepancy was 0.7 mm (Synergy®) and 0.9 mm (Trilock®), respectively. A total of 233 (86 %) acetabular components fell within the target zone for anteversion and inclination.

Conclusion

Accurate component positioning in MIS posterolateral approach THA is possible and is not influenced by the type of stem.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号