首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
BackgroundA head-elevation pillow places a patient in a ramped posture, which maximises the view of the larynx during laryngoscopy, particularly in obese parturients. In our institution an elevation pillow is used pre-emptively for neuraxial anaesthesia. We hypothesised that head-elevation may impair cephalad spread of local anaesthetic before caesarean section resulting in a lower block or longer time to achieve a T6 level. We aimed to investigate the effect of head-elevation on spread of intrathecal local anaesthetics during anaesthesia for caesarean section.MethodsOne-hundred parturients presenting for caesarean section under combined spinal-epidural anaesthesia were randomised to either the standard supine position with lateral displacement or in the supine position with lateral displacement on an head-elevation pillow. Each patient received intrathecal hyperbaric bupivacaine 11 mg, morphine 100 μg and fentanyl 15 μg. Patients were assessed for adequacy of sensory block (T6 or higher) at 10 min.ResultsSensory block to T6 was achieved within 10 min in 65.9% of parturients in the Elevation Pillow Group compared to 95.7% in the Control Group (P<0.05). Compared to the Control Group, patients in the Elevation Pillow Group had greater requirements for epidural supplementation (43.5% vs 2.1%, P<0.001) or conversion to general anaesthesia (9.3% vs 0%, P<0.04).ConclusionsUse of a ramped position with an head-elevation pillow following injection of the intrathecal component of a combined spinal-epidural anaesthetic for scheduled caesarean section was associated with a significantly lower block height at 10 min.  相似文献   

2.
BackgroundThe adverse effects of inadvertent perioperative hypothermia in the surgical population are well established. The aim of this study was to investigate whether a resistive warming mattress would reduce the incidence of inadvertent perioperative hypothermia in patients undergoing elective caesarean section.MethodsA total of 116 pregnant women booked for elective caesarean section were randomised to either intraoperative warming with a mattress or control. The primary outcome was the incidence of inadvertent perioperative hypothermia, defined as a temperature <36.0°C on admission to the recovery room. Shivering in the perioperative period, severity of shivering and the need for treatment, total blood loss, fall in haemoglobin, incidence of blood transfusion, immediate health of baby, and length of hospital stay were also recorded.ResultsThe incidence of inadvertent perioperative hypothermia in the mattress-warmed group was significantly lower than in the control group (5.2% vs. 19.0%, P = 0.043); mean temperatures differed between the two groups, 36.5°C and 36.3°C, respectively (P = 0.046). There was also a significantly lower mean (± SD) haemoglobin change in the mattress-warmed group at −1.1 ± 0.9 g/dL versus −1.6 ± 0.9 g/dL in the control group (P = 0.007). There was no difference in shivering (P = 0.798).ConclusionsA resistive warming mattress reduced the incidence of inadvertent perioperative hypothermia and attenuated the fall in haemoglobin. The use of resistive mattress warming should be considered during caesarean section.  相似文献   

3.
4.
IntroductionWe hypothesised that preoperative administration of a single-dose of pregabalin would be associated with lower morphine consumption after uncomplicated caesarean delivery.MethodsAfter Institutional Ethics Committee approval, 135 parturients scheduled for elective caesarean delivery under spinal anaesthesia were randomly allocated to receive either placebo, or oral pregabalin 150 mg or 300 mg, one hour before induction of anaesthesia. Maternal cumulative morphine requirement at 24 h, pain scores, sedation scores, nausea and vomiting, pruritus, pregabalin-related adverse effects, Apgar scores, Neurologic and Adaptive Capacity scores and umbilical cord acid-base status were recorded.ResultsCompared with placebo or pregabalin 150 mg, the use of a preoperative dose of pregabalin 300 mg resulted in significantly lower cumulative morphine consumption at 24 h (mean dose: placebo 12.9 mg [95% CI 11.6 to 14.2]; pregabalin 150 mg 11.9 mg; [95% CI 10.7 to 13.1]; pregabalin 300 mg 6 mg [95% CI 5.4 to 7.3]; P<0.001). Pregabalin 300 mg resulted in lower pain scores at 4 h and 6 h after delivery (P<0.001), and fewer instances of nausea, vomiting and pruritus (P<0.009). Dizziness and abnormal vision were observed most frequently in the pregabalin 300 mg group (P<0.05 and P<0.009, respectively). The three groups were similar in terms of maternal sedation, Apgar scores, Neurologic and Adaptive Capacity scores and umbilical cord acid-base status. Three babies in the pregabalin 300 mg group (6.7%) experienced short-term poor latching-on for breastfeeding.ConclusionIn our study, preoperative administration of pregabalin 300 mg reduced postoperative morphine consumption and early postoperative pain in parturients undergoing elective caesarean delivery, although maternal side effects were more common.  相似文献   

5.
ObjectiveThe aim of this study was to compare the efficacy of HES 130/0.4 coloading compared to normal saline solution for prevention of hypotension during spinal anesthesia for elective caesarean section.Study designProspective, randomized.Patients and methodsOne hundred and twenty ASA I and II patients scheduled for elective caesarean section were recruited. Patients were randomized to receive either 500 mL of HES 130/0.4 (Voluven®) coloading (Group V) or 500 mL of normal saline solution coloading (Group C). Spinal anesthesia technique and ephedrine administration were standardized in both groups. The primary endpoint was the incidence of maternal hypotension during spinal anesthesia for elective caesarean section.ResultsHypotension occurred in 43 patients in group C and 24 patients in group V (p = 0.001). Ephedrine consumption was significantly lower in group V (P = 0.005). Nausea, vomiting and headache incidence was higher in group C (p = 0.006). Apgar scores and umbilical blood gazes were comparable between groups.ConclusionHES 130/0.4 coload was more effective than normal saline solution to prevent hypotension following spinal anesthesia for elective cesarean section. HES 130/0.4 coload reduced the incidence, the duration of longest hypotension, the need for ephedrine and the adverse maternal effects.  相似文献   

6.
《Neuro-Chirurgie》2021,67(5):439-444
ObjectTo assess the incidence and analyze the risk factors of postoperative spinal epidural hematoma (SEH) after transforaminal lumbar interbody fusion (TLIF) surgery, in order to provide a solution for reducing the occurrence of postoperative SEH after TLIF.MethodsA total of 3717 patients who were performed TLIF surgery in the Orthopedics department of our hospital from January 2010 to March 2020 were included. Patients who had reoperations due to postoperative SEH were selected as the SEH group. The control group was randomly selected from patients without reoperations with the ratio of 3:1 compared to the SEH group. The basic information, preoperative examination and surgical information of the patients were collected through the hospital medical record system, and the statistics were processed through SPSS 22.0 software.Results(1) Among the 3717 patients who underwent TLIF surgery in our hospital in the past 10 years, 46 had secondary surgeries, with a total incidence of 1.24%. 12 cases had secondary surgeries due to postoperative SEH, with an incidence of 0.35%. (2) Univariate analysis identified eight factors potentially associated with risk for postoperative SEH, including older age, longer thrombin time (TT), higher level of alkaline phosphatase (ALP), higher number of fusion segments, revision surgery, having received blood transfusion, using of more than one gelatin sponge or using of styptic powder in the surgery, longer operation time and more blood loss in the surgery (P < 0.05). (3) On multivariate analysis, three factors were identified as independent risk factors, which include revision surgery (P = 0.021, OR = 7.667), longer TT (P = 0.027, OR = 2.586) and using of more than one gelatin sponge or using of styptic powder in the surgery (P = 0.012, OR = 9.000).ConclusionsRevision surgery (P = 0.021, OR = 7.667), longer TT (P = 0.027, OR = 2.586) and using of more than one gelatin sponge or using of styptic powder in the surgery were independent risk factors for postoperative SEH after TLIF.  相似文献   

7.
BackgroundPregnancy and puerperium are associated with a hypercoagulable state. The aim of the study was to assess the impact of spinal anaesthesia on coagulation using thromboelastography in healthy term pregnant women undergoing elective caesarean delivery.MethodsThromboelastography was performed on 60 women undergoing elective caesarean delivery under spinal anaesthesia. As spinal anaesthesia has different effects on upper and lower extremity vasculature, venous blood samples were collected from both hand and foot, before and one hour after spinal injection.ResultsIn the hand samples, R and K values decreased significantly from before to one hour after spinal injection (5.7 ± 1.9 min versus 3.6 ± 1.3 min, P < 0.001 and 2.1 ± 0.9 min versus 1.5 ± 0.4 min, P < 0.001, respectively). At the same times, significant increases in the alpha angle (58.6 ± 9.1 degrees versus 65.6 ± 7.5 degrees, P < 0.001), MA (85.1 ± 4.6 mm versus 87.0 ± 3.8 mm, P < 0.001) and CI (2.6 ± 2.1 versus 4.9 ± 1.5, P < 0.001) were seen. No significant changes were found in thromboelastography parameters in samples collected from foot veins before and one hour after spinal injection, with the exception of the alpha angle (62.1 ± 11.5 versus 66.5 ± 8.8 degrees, P < 0.012).ConclusionIn women undergoing caesarean delivery under spinal anaesthesia, enhanced coagulation thromboelastography parameters were observed in blood collected from hand veins. No changes were detected in the majority of parameters collected from the foot. Spinal anaesthesia has different effects on coagulation parameters in the hand and foot in pregnant women undergoing caesarean delivery.  相似文献   

8.
BackgroundSpinal anesthesia is widely used for cesarean section, but the factors that affect the spread of the block in pregnant patients are still not fully explained. This study was designed to investigate the effect of postural changes on sensory block level.MethodsThirty patients scheduled for elective cesarean section under combined spinal–epidural anesthesia were randomly allocated into three groups. After intrathecal injection of 0.5% plain bupivacaine 7.5 mg, patients in group S were immediately placed in the supine position with left tilt, patients in group L5 were kept lateral for 5 min and then turned to the supine position with left tilt, and patients in group L10 were kept lateral for 10 min and then turned to the supine position with left tilt.ResultsAt 5 min, median cephalad level of sensory block was lower in groups L5 and L10 compared with group S (corrected P<0.001); at 10 min, median cephalad sensory block level was lower in group L10 compared with group S (corrected P<0.001) and group L5 (corrected P<0.001), and lower in group L5 compared with group S (corrected P=0.033); at 15 min, median cephalad level of sensory block was lower in group L10 compared with group S (corrected P=0.003) and group L5 (corrected P=0.015).ConclusionsIn our population, using 0.5% plain bupivacaine 7.5 mg, postural change from the lateral position to the supine position is an important mechanism enhancing cephalic spread of spinal anesthesia during late pregnancy.  相似文献   

9.
BackgroundPhenylephrine given during spinal anaesthesia for caesarean delivery often induces a decrease in heart rate which may decrease cardiac output. Anticholinergic drugs may be given to attenuate this effect but may also cause more labile blood pressure. This study evaluated the effects of glycopyrrolate pre-treatment on non-invasively measured cardiac output and accuracy of blood pressure control.MethodsAt induction of spinal anaesthesia for caesarean delivery, 104 patients randomly received intravenous glycopyrrolate 4 μg/kg or saline placebo. Systolic blood pressure, measured at 1-min intervals, was maintained near baseline using closed-loop feedback computer-controlled phenylephrine infusion with crystalloid cohydration. Cardiac output and stroke volume were measured using suprasternal Doppler ultrasonography at baseline and 5-min intervals for 20 min. Blood pressure control was assessed using performance error calculations.ResultsEleven patients were excluded. Patients who received glycopyrrolate (n = 45) had greater cardiac output over time (P < 0.001), greater heart rate over time (P < 0.001), similar stroke volume over time (P = 0.95), and lower median phenylephrine infusion rate (P = 0.006) compared with control (n = 48). There was no difference in the incidence of hypotension between groups. Analysis of blood pressure control showed greater positive bias, greater inaccuracy and greater wobble in the glycopyrrolate group (all P < 0.05). Neonatal outcome was similar between groups.ConclusionsGlycopyrrolate 4 μg/kg given at the start of a phenylephrine infusion increased heart rate and cardiac output but also decreased accuracy of blood pressure control, increased the incidence of hypertension and caused an increased incidence of dry mouth postoperatively compared with control.  相似文献   

10.
BackgroundIntrathecal tramadol combined with local anaesthetics has been used for postoperative analgesia following lower abdominal and perineal surgery. The present study evaluated the effect of intrathecal tramadol on spinal block characteristics and neonatal outcome after elective caesarean section.MethodsEighty full-term parturients scheduled for elective caesarean section were randomly divided into two groups. In the fentanyl group, patients received intrathecal 0.5% bupivacaine 10 mg with fentanyl 10 μg; in the tramadol group, patients were given the same dose of bupivacaine with tramadol 10 mg. Sensory and motor block characteristics, duration of postoperative analgesia, maternal side effects, and neonatal outcome were compared.ResultsOne patient in the tramadol group and two patients in the fentanyl group were excluded from data analysis. Median [interquartile range] duration of postoperative analgesia in the tramadol and the fentanyl groups was 300 [240–360] min and 260 [233–300] min respectively (P = 0.02). The incidence of shivering was lower in patients who received tramadol (5%) than those who had fentanyl (32%) (P = 0.003). Apgar scores, umbilical cord acid–base measurement and neurologic and adaptive capacity scores were comparable between the two groups.ConclusionCompared to intrathecal fentanyl 10 μg, tramadol 10 mg, as an adjunct to bupivacaine for subarachnoid block for caesarean section, showed a longer duration of analgesia with a reduced incidence of shivering.  相似文献   

11.
BackgroundAt our institution, the emergency obstetric ‘code green’ activates the system for immediate birth, usually by caesarean section. This study aimed to determine the incidence of immediate birth, indications, modes of anaesthesia, and short-term neonatal and maternal outcomes.MethodA review was performed for all women at the Royal Women’s Hospital, Parkville, Australia who underwent immediate birth over a two-year period: January 1, 2013 to December 31, 2014.ResultsWithin the study period 14,115 women gave birth, of which 387 women underwent an immediate birth, the majority (83%) by caesarean section. The commonest indication for immediate birth was prolonged fetal bradycardia (53%), however cord prolapse (4%) produced the most rapid decision-to-delivery interval, with a median [IQR] time of 14 [13–16] min versus 18 [14–23] min for all immediate births (P < 0.01). Epidural top-up was the most common anaesthesia method. Conversion to general anaesthesia following inadequate neuraxial anaesthesia occurred in 6.2% of women. Among 103 general anaesthetics, there was one failed intubation (successful ventilation) and one dental injury. Nine women (2.3%) were admitted to the high dependency or intensive care units, and there were no maternal deaths. Babies born by caesarean section with a decision-to-delivery interval of less than 30 min were more likely to have longer times to establish respiration (22.6% vs 16.7%, P < 0.001).ConclusionRequest for immediate delivery is a common obstetric emergency. Epidural top-up has become the most common anaesthetic technique. Rapid delivery times can be achieved with an integrated emergency response system.  相似文献   

12.
13.
AimTo evaluate efficiency of dexmedetomidine compared to fentanyl as supplements to low-dose levobupivacaine spinal anesthesia in patients undergoing knee arthroscopy.Materials and methodsSixty adult patients (ASA I or II) scheduled for knee arthroscopy were randomized to receive plain levobupivacaine (4 mg) plus dexmedetomidine (3 μg) in group D or fentanyl (10 μg) in group F.ResultsDexmedetomidine shortened time to surgery (P = 0.002), time to highest sensory level (P = 0.001), and time to highest Bromage score (P < 0.001). The highest sensory level was comparable in both groups (P = 0.969), but the duration of sensory block was significantly longer in group D (P = 0.009). The highest Bromage score was 2 in both groups. This score was attained in significant higher number of patients in group D (P = 0.038) that showed better muscular relaxation (P = 0.035). At the end of surgery, a residual motor block (Bromage score 1) was observed in significant higher number of patients (P = 0.033) and time to ambulation was significantly longer in group D (P = 0.001). There was no difference in the number of patients bypassed post-anesthesia care unit (PACU) (P = 0.761) or time to hospital discharge (P = 0.357) between groups. The pain free period was more prolonged (P < 0.001), and the visual analog scale (VAS) for pain was lower at the 2nd, 4th, 6th, and 8th postoperative hours (P < 0.001, <0.001, 0.013, 0.030 respectively) in group D.ConclusionDexmedetomidine is a good alternative to fentanyl for supplementation of low-dose levobupivacaine spinal anesthesia for knee arthroscopy.  相似文献   

14.
ObjectiveThe aim of this study was to evaluate the contribution made by ultrasound-guided transversus abdominis plane block (TAP) to the quality of the analgesia with intrathecal opioids obtained in patients undergoing elective caesarean delivery.Material and methodsA prospective, randomized study in patients submitted to elective caesarean section with spinal anaesthesia with 0.5% hyperbaric bupivacaine. The patients were randomized into 3 groups according to the added complementary drug for analgesia: group A morphine 0.1 mg; group B fentanyl 10 μg; group C 10 μg fentanyl + bilateral TAP block. The TAP block with 20 ml of 0.5% levobupivacaine on each side, after surgery. Groups A and B, were injected with 20 ml of saline. Postoperative analgesia was performed with morphine bolus through a system of patient-controlled analgesia (PCA). We studied the pain on a visual analogue scale at 12 and 24 h at rest and movement, the time elapsed to require the first bolus, and morphine bolus in 24 h. Secondary effects such as nausea, vomiting, pruritus, and drowsiness, were also evaluated. The level of patient satisfaction was also recorded.ResultsA total of 90 patients were included. At rest the 12/24 h VAS score was: group A, at 12 h 2.1 ± 1.2, at 24 h 4.7 ± 1.6; group B at 12 h 4.3 ± 2.9, at 24 h 4.8 ± 2; group C at 12 h 1.9 ± 1.09, at 24 h 2.3 ± 1.2 (P<.05). Walking improved analgesia more in group C (P≤.02). The time of asking for the first bolus was lower in group B: group A 9.3 ± 4.9 h (P=.02 compared to group C), in group B 2 ± 1.8 h (P<.001 compared to group C) and group C 13.2 ± 2.1 h. The number of bolus in 24 h in group B was 38 ± 5, in group A 10 ± 2 (P<.05), group C 5 ± 2 (P<.001). Delayed nausea was increased in group B (36.6%) and pruritus was greater in group A (36.6%).ConclusionsUltrasound (US)-guided TAP block improves spinal opioid analgesia, with a decrease in VAS scores in the first 24 h, and reduces opioid requirement and secondary effects after caesarean delivery.  相似文献   

15.
BackgroundCombined spinal–epidural anaesthesia is commonly used for elective caesarean section. Intrathecal injection produces rapid onset with minimal doses of local anaesthetic and epidural administration can be used to prolong the block. Our study examined the effects of adding magnesium sulphate to epidural bupivacaine and fentanyl in patients undergoing elective caesarean section using combined spinal–epidural anaesthesia.MethodsWomen ASA physical status I or II at term were recruited. All received 2 mL intrathecal 0.5% hyperbaric bupivacaine, 10 mL epidural 0.25% plain bupivacaine with fentanyl 100 μg, and were randomly allocated to receive either 10 mL of epidural 0.9% sodium chloride or 10 mL epidural 5% magnesium sulphate. The quality of surgical anaesthesia, incidence of hypotension, Apgar scores, intraoperative pain assessment, onset of postoperative pain, sedation scores and side effects were recorded in the postoperative period.ResultsNinety women were recruited. There was no difference in the time taken for the block to reach T4 sensory level, time to reach the highest level of sensory block, time interval between first neuraxial injection and onset of surgery between the groups. Women who received magnesium had greater motor block and muscle relaxation (P < 0.05). Apgar scores were 7 or more in almost all neonates in both groups. There was no significant difference in the incidence of hypotension, nausea and vomiting and duration of motor blockade between the groups. Women who received magnesium showed less shivering and later onset of post operative pain (P < 0.05).ConclusionThe addition of magnesium to epidural bupivacaine and fentanyl in women undergoing elective caesarean section with combined spinal–epidural anaesthesia improved intraoperative conditions and the quality of postoperative analgesia.  相似文献   

16.
Background/aimGabapentin is an anticonvulsant drug that is safe and effective for the treatment of neuropathic pain syndrome, as well as postoperative pain with good results. This prospective randomized study was done to evaluate the effects of preoperative administration of oral gabapentin (1200 mg) on the intraoperative fentanyl and isoflurane consumption, postoperative analgesic requirements and postoperative pain in patients undergoing radical mastectomy.MethodsSixty ASA I and II patients were randomly allocated into two equal groups to receive oral gabapentin 1200 mg, 2 h before surgery (G group) or control (C group). General anesthesia was induced and maintained at bispectral index value between 40 and 60. During surgery the end-tidal isoflurane concentrations required to maintain adequate depth of anesthesia and the required incremental doses of intraoperative fentanyl were recorded. Postoperative pain was assessed using visual analogue scale (VAS) at rest for 24 h. Postoperatively, whenever visual analogue scale (VAS) was more than 5 or on patients’ demand, analgesia in both groups was provided with diclofenac sodium (1 mg/kg IM) or tramadol hydrochloride (1 mg/kg IV) as needed. VAS, analgesics requirements, and side-effects were assessed for 24 h postoperatively.ResultsIntraoperative fentanyl and postoperative analgesic consumption were significantly lower in G group than C group (P < 0.001). Patients in the G group had significantly lower end-tidal concentrations of isoflurane required to maintain adequate depth of anesthesia (P < 0.05). VAS was significantly lower in G group than C group at the first three measurement times (P < 0.01). The incidence of postoperative nausea and vomiting was significantly lower in G group than C group (30% versus 60% of patients, respectively, P < 0.05). The incidence of dizziness was significantly higher in the G group than C group (26% versus 3.3% of patients, respectively, P < 0.05).ConclusionGabapentin (1200 mg) administered orally 2 h before surgery decreased the intraoperative fentanyl and isoflurane consumption, postoperative analgesic requirements, postoperative pain, and the incidence of postoperative nausea and vomiting, but increased dizziness.  相似文献   

17.
BackgroundMost studies comparing phenylephrine and ephedrine have been conducted during elective caesarean sections in healthy mothers with no fetal compromise. The effect of vasopressors on fetal outcome may differ between healthy and compromised fetuses. There has been little research into the effect of phenylephrine and ephedrine, when used for management of post-spinal hypotension in the presence of potential fetal compromise.MethodsHealthy women with a singleton pregnancy undergoing emergency caesarean section for fetal compromise under spinal anaesthesia were studied. One-hundred-and-six consecutive subjects, who developed hypotension after spinal anaesthesia, were randomly allocated to two groups of 53 each, to receive either phenylephrine (Group P) or ephedrine (Group E). For every systolic blood pressure reading <100 mmHg patients received phenylephrine 100 μg or ephedrine 8 mg depending on group allocation. Umbilical blood gas parameters and Apgar scores were recorded.ResultsThere was no statistically significant difference in umbilical arterial pH (P=0.79), umbilical venous pH (P=0.98), other blood gas parameters, incidence of fetal acidosis (P=1.00) and Apgar scores. The number of hypotensive episodes, vasopressor doses for treatment of the first hypotensive episode and the total number of doses used during the study period were comparable. The median [IQR] total number of doses of phenylephrine and ephedrine used before delivery were 2 [1–2] and 2 [1–2], respectively (P=0.67). More patients receiving ephedrine (24.5%) developed tachycardia than those receiving phenylephrine (3.8%) (P=0.004). Bradycardia was more common with phenylephrine, with 39.6% of patients in Group P as compared to only 1.9% of patients in Group E developing a heart rate <60 beats/min after vasopressor administration (P=0.001).ConclusionsBoth phenylephrine 100 μg and ephedrine 8 mg boluses are equally efficacious when treating post-spinal hypotension in the presence of potential fetal compromise. However, phenylephrine may be a better choice in the presence of maternal tachycardia.  相似文献   

18.
BackgroundA pelvic tilt of 15° is standard practice when positioning a woman for caesarean section, and is commonly produced by tilting the operating table or placing a wedge under the right hip. This study investigated whether body mass index affects the degree of pelvic tilt produced when a wedge is used.MethodsWomen undergoing category 3 and 4 caesarean sections were stratified into three groups according to their body mass index at antenatal booking: ⩽25 kg/m2, 25.1–35 kg/m2 and >35 kg/m2. Twenty women were recruited into each group. Lateral tilt at caesarean section was provided with a Crawford wedge under the right hip and the degree of pelvic tilt was measured using a protractor device.ResultsThe median [range] pelvic tilt angle for the groups in order of ascending body mass index were 15° [12–22°], 19° [11–29°] and 17° [2–28°]. There was a significant increase in the variability of pelvic tilt with increasing body mass index (P = 0.001). The proportion of patients with pelvic tilt <15° was observed to be 20%, 15% and 30% for women of body mass index ⩽25 kg/m2, 25.1–35 kg/m2 and >35 kg/m2, respectively.ConclusionVariability in pelvic tilt increased with body mass index and was greatest with a booking body mass index >35 kg/m2.  相似文献   

19.
BackgroundUltrasound can facilitate neuraxial blockade in patients with poorly defined anatomical surface landmarks, but there are no studies comparing an ultrasound-guided technique with landmark palpation for spinal anaesthesia. The objective of this study was to compare pre-procedural lumbar ultrasonography with landmark palpation to locate the needle insertion point in women with impalpable lumbar spinous processes presenting for caesarean delivery.MethodsAfter institutional ethics committee approval, 20 women with impalpable lumbar spinous processes presenting for elective caesarean delivery were recruited. Patients were randomised to palpation or ultrasound. The primary outcome of the study was the number of needle passes to achieve lumbar puncture. Secondary outcomes were the overall procedural time and patient satisfaction score.ResultsThere was no difference in mean (±SD) body mass index of both groups (ultrasound 39.1 ± 5.02 kg/m2 vs. palpation 38.3 ± 3.77 kg/m2). There were significantly fewer needle passes in the ultrasound group (median 3 [IQR 1.8–3.2]) compared to the palpation group (median 5.5 [IQR 3.2–7.2] (P=0.03)). More time was required to locate the needle insertion point in the ultrasound group (ultrasound 91.8 ± 30.8 s vs. palpation 32.6 ± 11.4 s, P <0.001). There was no difference in the total procedural time between groups (ultrasound 191.8 ± 49.4 s vs. palpation 192 ± 110.9 s, P=0.99).ConclusionThe use of ultrasonography to locate the needle insertion point reduced the number of needle passes in women with impalpable lumbar spinous processes undergoing elective caesarean delivery under spinal anaesthesia. Its use did not prolong overall procedural time.  相似文献   

20.
BackgroundMost patients undergoing caesarean delivery with general anaesthesia require systemic opioid administration. Due to its rapid onset and long duration of action, intravenous methadone may make it suitable for analgesia after caesarean delivery. Intraoperative methadone combined with postoperative intravenous patient-controlled analgesia with fentanyl or morphine has recently been introduced in our unit.MethodsA retrospective case-control study of 25 patients who had received methadone was performed. Fifty control patients undergoing elective or emergency caesarean delivery were matched for the use of postoperative intravenous patient-controlled analgesia, transversus abdominis plane (TAP) block and regular non-steroidal anti-inflammatory drugs. Exclusion criteria included preoperative neuraxial analgesia or pre-delivery opioid consumption greater than 10 mg of intravenous morphine equivalents.ResultsPatients in the methadone group had lower pain scores and were less likely to require intravenous opioid supplementation in the post-anaesthetic care unit (P < 0.001). Opioid consumption over 48 h was significantly lower in the methadone group. Delayed discharge from the post-anaesthesia care unit was due to sedation in one patient in the methadone group compared to three control patients in whom it was due to sedation and inadequate analgesia.ConclusionA single intraoperative bolus of intravenous methadone appeared to provide effective analgesia with an acceptable side-effect profile.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号