首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
PURPOSE: The purpose of this work was to describe the MR appearance of tears of the subscapularis tendon and compare the usefulness of different imaging planes as well as note the association of subscapularis tears with other rotator cuff tears and biceps tendon dislocations. METHOD: MR studies at 1.5 T over an 8 year interval were retrospectively assessed for the presence of a rotator cuff tear and/or tear of the subscapularis tendon. Images that showed a subscapularis tear were reviewed for the presence of a visible tear separately on the axial, coronal, and sagittal images. The MR studies were also evaluated for associated tears of the supraspinatus, infraspinatus, and teres minor muscles as well as biceps tendon dislocation and the "naked humerus sign" on coronal images. Last, clinical records and surgical reports were reviewed. RESULTS: Forty-five (2%) of 2,167 rotator cuff tears involved the subscapularis; 27% were partial and 73% were complete tears. Tears were best seen in the sagittal oblique plane. Almost all subscapularis tears were an extension of typical rotator cuff tears: supraspinatus in 35 patients (79%), extending into infraspinatus tears in 25 (56%) and into teres minor tears in 2 patients (4%). Bicipital dislocations were seen in 22 patients (49%), and three complete tears of the biceps (7%) were noted as well. The naked humerus sign was demonstrated in 31 patients (69%). Surgical reports that confirmed the MR findings were available for 15 patients. CONCLUSION: About 2% of rotator cuff tears involve the subscapularis tendon. Most subscapularis tears are extensions of supraspinatus tears and frequently involve the biceps tendon.  相似文献   

3.
To determine the histopathologic correlates of alterations in the rotator cuff at magnetic resonance (MR) imaging, 13 cadaveric shoulders (in subjects aged 26-83 years at the time of death) underwent MR imaging in the coronal oblique plane at 1.5 T with proton-density- and T2-weighted spin-echo sequences. Areas corresponding to sites of MR imaging alterations were then examined histologically. Increased signal intensity on proton-density-weighted images (without further increased signal intensity on T2-weighted images) and an indistinct margin at the articular side of the supraspinatus tendon corresponded to eosinophilic, fibrillar, and mucoid degeneration and scarring. Areas of increased signal intensity on T2-weighted images were associated with severe degeneration and disruption of the supraspinatus tendon. Although other authors have suggested that certain MR findings are indicative of tendinitis, the histologic data in this study were not those of active inflammation but rather tendon degeneration.  相似文献   

4.
包磊  姚伟武  杨世埙   《放射学实践》2012,27(11):1246-1249
目的:探讨MR化学位移成像技术在定量测量肩袖损伤后冈上肌脂肪性退变中的临床应用价值。方法:38例临床上疑有肩袖损伤或肩峰撞击的患者为研究对象,行MR间接关节造影后,进行常规序列和化学位移序列MRI扫描。根据MR间接关节造影检查结果,肩袖损伤后冈上肌肌腱病理改变可分为4组:正常组、肌腱炎组、部分撕裂组和完全撕裂组。通过测定冈上肌的信号强度,然后分别计算出信号强度抑制率和信号指数值作为反映脂肪变性程度的指标,对比分析正常组和肩袖损伤各组的冈上肌脂肪变性程度。统计学方法采用Wilcoxon秩和检验。结果:正常组、肌腱炎组、部分撕裂组和完全撕裂组冈上肌信号强度抑制率中位数分别是-5.51%(-7.85%~3.50%)、-14.78%(-29.31%~-5.63%)、-31.74%(-45.54%~-13.63%)和-44.50%(-57.32%~-26.27%),信号强度指数中位数依次为3.91%(-4.37%~13.83%)、12.75%(5.73%~27.38%)、25.17%(14.32%~34.13%)和38.26%(27.66%~53.94%)。正常组与部分撕裂组、正常组与完全撕裂组、肌腱炎组与完全撕裂组间两两比较,差异有高度统计学意义(P〈0.01);正常组与肌腱炎组、肌腱炎组与部分撕裂组、部分撕裂组与完全撕裂组间两两比较,差异有统计学意义(P〈0.05)。结论:MR化学位移成像技术是定量测定冈上肌脂肪性退变程度的-种有I临床应用价值的手段,有助于对肌腱病变进行分级并指导临床治疗。  相似文献   

5.
肩袖全层撕裂的MRI表现   总被引:7,自引:0,他引:7  
目的 总结肩袖全层撕裂的MRI表现。材料与方法 回顾性分析21例肩关节MR造影证实的肩袖全层撕裂的MR图像。结果 21例肩袖全层撕裂均发生在冈上肌腱。在T2W序列上,6例(28.9%)表现为冈上肌腱断裂并断裂端的回缩;12例(57.1%)表现为冈上肌腱变薄或增粗并伴有贯穿冈上肌腱全层的高信号;1例(4.7%)表现为冈上肌腱增厚并未贯穿全层的下表面高信号;2例(9.3%)冈上肌腱的形态和信号未见异常。结论 冈上肌腱的断裂并回缩以及冈上肌腱形态增粗或变细并伴 有贯穿肌腱全层的异常高信号为全层撕裂的主要MRI表现。  相似文献   

6.
We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins.  相似文献   

7.
S A Mirowitz 《Radiology》1991,180(3):735-740
The signal intensity and morphologic characteristics of the rotator cuff and surrounding structures at magnetic resonance (MR) imaging were investigated with five pulse sequences in 15 asymptomatic subjects. In all subjects, a focal region of relative increased signal intensity corresponding to the critical zone was observed in the supraspinatus tendon just proximal to its insertion. Soft-tissue signal intensity (isointense with muscle) was also located between the supraspinatus tendon and underlying joint capsule, interposed between the conjoined leaves of the supraspinatus and infraspinatus tendons, and superolateral to the conjoined cuff tendon, near its insertion. These regions were most conspicuous and most clearly defined with fat-suppression imaging. Small amounts of fluid were observed within the joint space and its recesses, the bicipital tendon sheath, and the subacromial-subdeltoid bursa. These and other MR imaging findings of this study previously have been regarded as indicative of rotator cuff abnormalities. These results will help refine the criteria for diagnosis of rotator cuff disorders with MR imaging.  相似文献   

8.
Rotator cuff lesions: signal patterns at MR imaging   总被引:4,自引:0,他引:4  
The signal intensity patterns of rotator cuff lesions at magnetic resonance (MR) imaging were evaluated in 80 patients who had surgical correlation and in 13 asymptomatic individuals (14 shoulders). Six cadaver shoulders were examined with MR, and histologic correlation was obtained in four. All studies were performed at 1.5 T with a flexible circular surface coil. The accuracy of MR imaging in detection of full-thickness cuff tears (31 patients) was 0.95 and of partial thickness tears (16 patients), 0.84. The most common and accurate pattern for full-thickness cuff tears (22 of 31 tears) was a region of intense signal seen on T2-weighted images. Less often the torn region consisted of an extremely degenerated and attenuated tendon with moderate signal intensity or was obscured by low-signal-intensity scar. The intense signal pattern on T2-weighted images was also accurate, although a less common finding (seven of 16 cases), in the diagnosis of partial tears. Tendinitis was recognized as focal or diffuse regions of increased signal intensity or a nonhomogeneous pattern of increased signal often associated with tendinous enlargement. In some patients, manifestations of subacromial-subdeltoid bursitis was present. Tendon degeneration was also manifested as regions of increased signal intensity. Some similarity and overlap of signal patterns of partial interstitial tears, tendinitis, and tendon degeneration are observed.  相似文献   

9.
Shoulder impingement syndrome: MR findings in 53 shoulders   总被引:3,自引:0,他引:3  
The shoulder impingement syndrome refers to a condition in which the supraspinatus tendon and subacromial bursa are chronically entrapped between the humeral head inferiorly and either the anterior acromion itself, spurs of the anterior acromion or acromioclavicular joint, or the coracoacromial ligament superiorly. As a result, the space for the bursa and tendon is reduced, and repeated trauma to these structures leads to bursitis and rotator cuff injury. Although pain and limitation of motion are common early findings, the diagnosis is often delayed until a complete tear of the rotator cuff has occurred. In an attempt to determine if MR can be used to depict the abnormalities associated with impingement syndrome (subacromial bursitis, supraspinatus tendinitis, and rotator cuff tear), we reviewed 107 MR scans of painful shoulders. Changes consistent with impingement syndrome were found in 53 patients (50%), 32 of whom underwent subsequent arthrography or surgery. MR was found capable of depicting several soft-tissue and bony abnormalities that have been clinically described in impingement syndrome. In regions of inflammation, we found that the supraspinatus tendon and/or the subacromial bursa were compressed by spurs (25 shoulders), capsular hypertrophy of the acromioclavicular joint (six shoulders), and/or low-lying acromion (14 shoulders). While T1-weighted MR imaging was highly sensitive to abnormalities of the supraspinatus tendon, tendinitis could be differentiated from a small tear of the supraspinatus tendon only with T2-weighted imaging. Large, full-thickness tears, especially if chronic, produced characteristic MR findings on both T1- and T2-weighted images. We conclude that MR can be used to detect several abnormalities associated with the shoulder impingement syndrome.  相似文献   

10.
Rotator cuff: evaluation with US and MR imaging.   总被引:6,自引:0,他引:6  
Magnetic resonance (MR) and ultrasound (US) imaging are currently touted for assessment of rotator cuff disease. Optimum clinical imaging techniques include use of (a) a 1.5-T MR imaging unit with small planar coils, proton-density-weighted and T2-weighted fast spin-echo sequences, and 10-12-cm fields of view (yielding 400-470 x 500-625-microm in-plane spatial resolution) and (b) a state-of-the-art commercial US unit with insonation frequencies of 9-13 MHz (yielding 200-400-microm axial and lateral resolution). Proper diagnosis requires familiarity with normal anatomic characteristics and imaging pitfalls. Care must be taken to avoid sonographic tendon anisotropy and MR imaging magic angle effects, which can be misinterpreted as rotator cuff tear. At MR imaging, a complete cuff tear typically appears as either a hyperintense defect or a tendinous avulsion that extends from the bursal to the articular side of the cuff; a partial cuff tear typically appears as a focal hyperintense region that contacts only one surface of the cuff. Complete and partial tears manifest with a wide spectrum of findings at US. MR imaging and US are effective for evaluating rotator cuff injuries, with high reported accuracies for detection of complete tears but more disparate results for detection of partial tears.  相似文献   

11.
MR imaging has been shown to be accurate in the diagnosis of rotator cuff disruption and tear. Uncertainty remains about the significance of increased signal intensity in the critical zone of the supraspinatus tendon without visible disruption of tendon fibers and about the significance of other secondary findings commonly encountered with rotator cuff abnormalities, such as musculotendinous retraction or obliteration and fluid in the subacromial space. We evaluated proton density-weighted and T2-weighted coronal images (obtained on a 1.5-T superconductive MR imager) of 55 shoulders in 32 asymptomatic volunteers for signal intensity in the supraspinatus tendon, location of the musculotendinous junction, fluid in the subacromial-subdeltoid space, and appearance of the fat plane. In 89% of shoulders, the supraspinatus tendon showed focal, linear, or diffuse increased signal intensity with or without loss of the low-signal-intensity tendon margin on proton density-weighted images. None of these findings were confirmed on T2-weighted images. The musculotendinous junction was always located within an area 15 degrees medial to 30 degrees lateral to the highest point (12 o'clock) on the humeral head convexity. A peribursal fat plane was poorly defined or absent in 49%, and fluid in the subacromial-subdeltoid space was found in 20%. Increased signal intensity in the supraspinatus tendon on proton density-weighted images without a corresponding increase on T2-weighted images, the presence of small amounts of fluid in the subacromial space, and the lack of preservation of the subdeltoid fat plane are common findings in asymptomatic shoulders and by themselves are poor predictors of rotator cuff disease.  相似文献   

12.
A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patients, T2-weighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography.  相似文献   

13.
14.
Pathology of the rotator cuff is the cause of most common problems at the shoulder joint. Acute injuries are not as frequent as chronic cuff disease, but often they aggravate inflammatory or degenerative tendon alterations, even if they are of minor severity. Traumatic rotator cuff tears predominantly affect the supraspinatus tendon or the rotator interval. The subscapularis tendon is involved in anterior dislocations of the glenohumeral joint or in direct trauma. Plain film radiography still remains the base of all further imaging studies. If only full-thickness tears must be ruled out, double-contrast arthrography and ultrasound are acceptable imaging modalities. However, the former has a drawback in being invasive and does not detect partial tears at the bursal site of the cuff or rotator cuff tendinopathy, whereas the latter heavily depends on the experience of the radiologist and is restricted to the rotator cuff. Nowadays the most comprehensive imaging method is magnetic resonance (MR) imaging. MR imaging enables the detection or exclusion of complete rotator cuff tears with a reasonable accuracy and is also suitable to diagnose further pathologies of the shoulder joint. MR arthrography is valuable in the detection of subtle anatomic details and further improves the differentiation of rotator cuff diseases. Although in comparison MR imaging is still the most expensive imaging method, its high negative predictive value for the diagnosis of complete rotator cuff tears and its reliability evaluating different shoulder joint pathologies make it the preferred imaging modality.  相似文献   

15.
Purpose: To compare the diagnostic performance of multidetector computed tomographic (CT) arthrography and 1.5-T magnetic resonance (MR) arthrography in the evaluation of rotator cuff lesions, with arthroscopic correlation. Materials and Methods: This study was approved by the institutional ethical committee, and informed consent was obtained from all patients. CT and MR arthrographic images prospectively obtained in 56 consecutive patients, following the same arthrographic procedure, were independently evaluated by two radiologists. Arthroscopy, performed within 1 month of the imaging, was used as the reference standard. Sensitivity and specificity of CT and MR arthrography were compared by using the McNemar test. Interobserver and intertechnique agreement for detecting rotator cuff lesions were measured and compared with κ and Z statistics. The Bland-Altman method was used to determine interobserver and intertechnique agreement for measuring tendon tears. For grading fatty infiltration of rotator cuff muscles, κ and Z statistics were used. Results: There was no statistically significant difference in sensitivity and specificity between CT arthrography and MR arthrography in depiction of rotator cuff lesions. The respective sensitivity and specificity of CT arthrography were 92% and 93%-97% for the supraspinatus, 100% and 77%-79% for the infraspinatus, 75%-88% and 85%-90% for the subscapularis, and 55%-65% and 100% for the biceps tendon. The respective sensitivity and specificity of MR arthrography were 96% and 83%-93% for the supraspinatus, 88%-100% and 81%-83% for the infraspinatus, 75%-88% and 90%-100% for the subscapularis, and 65%-85% and 100% for the biceps tendon. Interobserver agreement was substantial to almost perfect (κ = 0.744-0.964 for CT arthrography; κ = 0.641-0.893 for MR arthrography), and intertechnique agreement was almost perfect (κ > 0.819). CT and MR arthrography both yielded moderate interobserver and intertechnique agreement for measuring rotator cuff tears and grading muscle fatty infiltration. Conclusion: Data suggest that CT and MR arthrography have similar diagnostic performance for the evaluation of rotator cuff tendon tears. ? RSNA, 2012.  相似文献   

16.
Yao L  Mehta U 《Radiology》2003,226(1):161-164
PURPOSE: To evaluate associated findings in patients who exhibited atrophy of infraspinatus muscle at magnetic resonance (MR) examination of their shoulders to clarify implications of this abnormality. MATERIALS AND METHODS: With an electronic database search, cases of advanced infraspinatus muscle atrophy in patients who underwent MR imaging during a 1-year period for evaluation of shoulder pain or dysfunction were identified. The analysis was restricted to cases interpreted by one reader who applied a standardized method of reporting. Associated MR imaging findings in these cases were tabulated. RESULTS: Advanced infraspinatus muscle atrophy was encountered in 51 (4.3%) of 1,191 MR examinations of the shoulder. Tears of the infraspinatus tendon were present in only 27 (53%) of 51 cases. In 46 (90%) of 51 cases, a full-thickness tear was present in the anterior portion of the rotator cuff. In 10 (20%) of 51 cases with infraspinatus muscle atrophy, cuff muscle atrophy was confined to the infraspinatus muscle. Cuff muscle atrophy was isolated to the infraspinatus muscle in four (17%) of 24 cases in which atrophy of the infraspinatus muscle was present despite an intact tendon. In none of the 51 cases was there a mass in the suprascapular or sphenoglenoid notch. CONCLUSION: Infraspinatus muscle atrophy typically occurs with tendon tears in the anterior aspect of the rotator cuff. Concomitant atrophy in the supraspinatus muscle often is present, but infraspinatus muscle atrophy can occur in isolation, and this finding does not imply that the infraspinatus tendon is ruptured.  相似文献   

17.
MR arthrography of the shoulder: comparison with conventional MR imaging   总被引:5,自引:0,他引:5  
Twenty-three patients underwent both conventional MR imaging of the shoulder and MR shoulder arthrography for clinically suspected labral or rotator cuff abnormalities. Images obtained before and after contrast administration were studied independently, and without knowledge of clinical findings, by two radiologists for the presence of abnormalities of the glenoid labrum or rotator cuff. Results were correlated with surgical findings in all patients. Nine patients had surgically proved labral tears. MR arthrography detected all nine labral abnormalities, while six of the nine were missed on conventional MR imaging. Fourteen patients had surgically proved rotator cuff tears. MR arthrography detected 11 of the 14 tears and missed three partial tears on the bursal surface. Conventional MR imaging detected nine cuff tears and missed five tears; two of these were complete rotator cuff tears and three were partial tears of the undersurface of the rotator cuff. Our results suggest that MR arthrography enhances the accuracy of MR in the evaluation of the glenoid labrum and rotator cuff tendon.  相似文献   

18.
Magnetic resonance imaging has been assessed in patients with acute rotator cuff tears and normal radiographs (9 cases) and those with chronic tears and changes of cuff arthropathy (9 cases). All images were obtained using a low field strength system (FONAR 0.3 T). Particular attention was placed on the appearances of the tendon and the cuff muscles themselves. Six complete acute tears were clearly identified, but MRI failed to demonstrate two partial tears. Muscle bulk was preserved in all patients in this group. In contrast, all patients with cuff arthropathy had complete tears of the supraspinatus tendon with marked tendon retraction and associated muscle atrophy: these changes precluded primary surgical repair. MRI should be used to assess muscle atrophy preoperatively in those patients with acute tears. When plain radiographs demonstrate cuff arthropathy, the MRI appearances are predictable and primary repair is unlikely to be successful. Further imaging is therefore not indicated.  相似文献   

19.
PURPOSE: To evaluate proton magnetic resonance (MR) spectroscopy in the assessment of lipid content of the supraspinatus muscle in asymptomatic volunteers and patients with supraspinatus tendon lesions. MATERIALS AND METHODS: Single-voxel proton MR spectroscopy was used to assess lipid content of the supraspinatus muscle in asymptomatic volunteers (n = 30) and patients with partial-thickness supraspinatus tendon tears (n = 30), newly diagnosed full-thickness supraspinatus tendon tears (n = 30), and chronic full-thickness supraspinatus tendon tears (n = 30). The apparent lipid content of the supraspinatus muscle measured with proton MR spectroscopy was related to its appearance on sagittal-oblique T1-weighted spin-echo MR images (grades 0-4). One-way analysis of variance was performed to test for significant differences, and the Tukey honestly significant difference procedure was performed for post hoc comparisons. RESULTS: Mean apparent lipid content was 13.7% (95% confidence interval [CI]: 11.5%, 15.8%) for asymptomatic volunteers, 29.5% (95% CI: 25.1%, 34.0%) for patients with partial-thickness tears, 48.6% (95% CI: 41.3%, 55.9%) for patients with full-thickness tears, and 66.1% (95% CI: 57.7%, 74.5%) for patients with chronic tears. Values were significantly different (analysis of variance, P <.001; P <.001-.002 for all post hoc pairwise comparisons). Mean apparent lipid content for the supraspinatus muscle was as follows: grade 0, 19.6% (95% CI: 16.7%, 22.6%); grade 1, 36.8% (95% CI: 33.2%, 40.4%); grade 2, 53.6% (95% CI: 43.1%, 64.2%); grade 3, 67.5% (95% CI: 52.6%, 82.3%); and grade 4, 79.2% (95% CI: 73.2%, 85.3%). With analysis of variance (P <.001), all post hoc pairwise comparisons were significant (P 相似文献   

20.
Purpose To re-evaluate the relationship between os acromiale and rotator cuff tears. Methods We retrospectively analyzed 84 magnetic resonance imaging studies of the shoulder. Forty-two subjects with os acromiale (n = 42; 32 men and ten women, age 25–81 years, mean 47.6 years) were compared with age- and gender-matched subjects with no evidence of os acromiale (controls). Arthroscopy data were available in 19 os acromiale and 12 control subjects. Statistical analyses were performed to determine differences between groups regarding rotator cuff tears affecting the supraspinatus and infraspinatus tendons detected by magnetic resonance imaging and arthroscopy. Analysis of os acromiale type, ossicle synchondrosis edema, acromioclavicular joint degenerative changes and step-off deformity at the synchondrosis were tabulated. Results No statistically significant difference between the os acromiale and control groups was noted, either on magnetic resonance imaging or arthroscopy, with regard to tears of the supraspinatus (P = 1.000 and 0.981, respectively) and infraspinatus (P = 1.000 and 0.667, respectively) tendons. There was a statistically significant increased number of supraspinatus (P = 0.007) and infraspinatus (P = 0.03) tears in a comparison of subjects with os acromiale and step-off deformity (10/42) vs os acromiale without step-off deformity (32/42). Conclusion The presence of os acromiale may not significantly predispose to supraspinatus and infraspinatus tendon tears. However, subjects with step-off deformity of an os acromiale are at greater risk of rotator cuff tears than are similar subjects without such deformity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号