 共查询到20条相似文献,搜索用时 781 毫秒
1.
Eleven patients (4 female, 7 male), age range 3.3 to 24.8 years (mean 11.10 years) treated for isolated pulmonary stenosis underwent cardiac catheterization and percutaneous transluminal balloon valvuloplasty (PTVP). The right ventricular systolic pressure (RVSP) before valvuloplasty ranged from 31 to 127 mmHg (mean 79 mmHg) decreasing to 28 to 62 mmHg (mean 42 mmHg) immediately after the dilatation. The peak systolic gradient of the pulmonary valve (delta p RV-PA) before valvuloplasty ranged from 22 to 107 mmHg (mean 61 mmHg) and decreased to a range of 14 and 45 mmHg (mean 23 mmHg) immediately after the dilatation. Balloon valvuloplasty was performed using balloons of 13 to 31 mm in diameter. On 11 patients cardiac catheterization and Doppler echocardiography were repeated between 11 months and 5.3 years (mean 3.11 years) after the balloon valvuloplasty showed a further significant fall in the gradient of pressure. The right ventricular systolic pressure ranged from 20 to 51 mmHg (mean 31.7 mmHg) while the transpulmonary gradient varied from 3 to 24 mmHg (mean 11.6 mmHg). At the time of follow-up examination the patients were aged between 7.2 and 25.7 years (mean 15.9 years). On average the second catheterization was performed 3.11 years following the first hemodynamic study. The follow-up examination encompassed clinical examination, electrocardiogram, Doppler echocardiography, and right heart cardiac catheterization. During right heart cardiac catheterization the children exercised on a bicycle ergometer for three min at 50 or 100 W depending on their body surface area. During this exertion, pressures of the right ventricle and the pulmonary artery as well as heart rate and oxygen saturation were recorded.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
The results of percutaneous balloon aortic valvuloplasty (PBAV) in 62 consecutive patients with valvular aortic stenosis are reported. The age of the patients ranged from 11 months to 72 years (mean 28 +/- 12 years). Hemodynamically successful dilatation was achieved in 58 out of 62 patients. This was associated with marked clinical improvement in these patients. The left ventricular aortic peak to peak gradient decreased from 96.67 +/- 38.4 to 28.14 +/- 26.5mmHg (p < 0.01). There were no deaths during the procedure. Only one patient died in the hospital during the same admission. There was an increase in aortic regurgitation (AR) by at least one grade in 25 (40.3%) patients. Femoral arterial thrombosis was seen in 9/62 patients, 5 of them requiring surgical intervention. Follow up was available in 28 (45.1%) patients over a period of 2-15 months (mean 9 +/- 3 months). Two patients died during the follow up period. Doppler evaluation of gradients was done in all 28 patients with 15 consenting to undergo repeat cardiac catheterisation. Although hemodynamically the restenosis rate was 35.7% (10/28), only 2 of these patients showed symptomatic deterioration. The success of dilatation and restenosis rate were independent of the etiology of aortic stenosis, presence of calcification and the number of balloons used. This study demonstrates that PBAV is feasible in valvular aortic stenosis at low risk and is able to produce significant clinical and hemodynamic improvement in most cases with a restenosis rate of 35.7% at a follow up period of 9 +/- 3 months.  相似文献   

3.
目的 通过与心导管测量对比来评价经皮肺动脉瓣球囊成形术(PBPV)前后应用Doppler超声心动图估测跨瓣压差的临床价值。方法 对178例患者在行PBPV术前利用Doppler测量肺动脉瓣跨瓣压差(△P’),与相应的心导管测量值(△P)作相关性分析;并利用Doppler对PBPV术后48例患者进行了4~102个月(平均19.5个月)的随访。结果Doppler测量的△P’值与导管测量的△P值之间有着良好的直线相关性,r值为0.80,P<0.05;随访中Doppler测量的△P’值与PBPV术后即刻导管测量的△P值之间差异无显著性(P=0.05)。结论Doppler超声作为一种准确、无创、简便而有效的检查方法,对估计PBPV术前肺动脉瓣狭窄程度,评价术后疗效有较高的临床应用价值。  相似文献   

4.
A young girl who underwent repair of an atrial septal defect and pulmonary valvulotomy when 6 years of age, presented with clinical and haemodynamic signs of pulmonary restenosis 11 years later: right ventricular systolic pressure (RVSP) of 130 mmHg with a systolic RV/PA pressure gradient of 105 mmHg. Pulmonary valvuloplasty was performed using a balloon catheter (20 mm X 40 mm). Two inflations were necessary to correct the hour glass deformity of the balloon caused by the stenosis. After valvuloplasty the RVSP was 75 mmHg and the RV/PA gradient 55 mmHg. The calculated pulmonary valve surface area increased from 0.36 cm2 to 0.72 cm2. Angiography performed immediately after dilatation showed improved valvular mobility but here was persistant severe infundibular hypertrophy. The intensity of the pulmonary systolic murmur decreased. The good result obtained in this case shows that percutaneous valvuloplasty may be considered when restenosis occurs several years after surgical valvulotomy. Control catheterisation performed two months after dilatation confirmed the good initial haemodynamic result.  相似文献   

5.
To assess the safety and efficacy of percutaneous balloon valvuloplasty in calcific aortic stenosis, balloon dilatation of critically stenosed, calcified aortic valves was performed in five postmortem hearts, in five patients intraoperatively before aortic valve replacement, and in two elderly patients percutaneously at the time of diagnostic catheterization. The etiology of aortic stenosis in the 12 cases was rheumatic in two, congenital bicuspid calcific stenosis in one, and senile calcific degenerative stenosis in the remaining nine. Prevalvuloplasty examination in the 10 postmortem and intraoperative cases revealed rigid valve leaflets with commissural fusion in three valves and extensive nodular calcification in seven. Subsequent balloon dilatation with 15 to 18 mm valvuloplasty balloons resulted in decreased cusp rigidity and increased mobility of valve leaflets in all cases, without evidence of tearing of valve leaflets, disruption of the valvular ring, or liberation of calcific or valvular debris. In the three valve specimens with commissural fusion, balloon dilatation resulted in partial or complete separation of leaflets along fused commissures. In two cases with extensive nodular calcification, balloon dilatation resulted in a fracture of a calcified leaflet that was evident on both gross and radiologic examination. After postmortem and intraoperative studies, percutaneous catheter valvuloplasty was performed at the time of diagnostic catheterization in two elderly patients (93- and 85-year-old women) with long-standing calcific aortic stenosis. Balloon dilatation with 12 to 18 mm balloons resulted in significant decreases in aortic gradients and significant increases in cardiac index and aortic valve area in both patients. Percutaneous valvuloplasty in both patients resulted in a mild increase in aortic insufficiency and no evidence of embolic phenomena.  相似文献   

6.
From June 1984 to March 1987, percutaneous balloon valvuloplasty (PBV) was performed for 22 patients with congenital pulmonary valvular stenosis. It was successful for 20 patients, and there were significant decreases of transvalvular pressure gradients; 72 +/- 30 mmHg before PBV, and 30 +/- 12 mmHg immediately after PBV (p less than 0.001). In a follow-up study, pulsed Doppler echocardiography and cardiac catheterization were used to examine changes in long-term hemodynamic findings after PBV. One year follow-up evaluation was performed for 14 patients, and two year follow-ups for seven patients. One year after PBV the transvalvular pressure gradients were evaluated during cardiac catheterization in 11 patients, and using pulsed Doppler echocardiography in the remaining three patients. The gradients of the seven patients at two year intervals after PBV were evaluated using pulsed Doppler echocardiography. The pressure gradients of two patients improved further one year later due to the anatomical degradation in the right ventricular outflow tracts. For seven patients, two year follow-up evaluations were performed, and the transvalvular pressure gradient reduced from 84 +/- 23 to 33 +/- 15 mmHg (p less than 0.001) immediately afterwards; to 27 +/- 22 mmHg (p less than 0.01) one year later; and further to 12 +/- 5 mmHg (p less than 0.001) two years after PBV. Second PBV was performed for three patients in whom a residual gradient was recognized, with the good results. On auscultation, a pulmonary regurgitant murmur was recognized in 28% of 18 patients immediately after PBV, but 80% of this resolved one year later. Two patients had pulmonary regurgitation with pulmonary valvular stenosis before PBV.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
Percutaneous transluminal balloon catheterization was performed in 38 patients, age 2 to 38 years (mean 13) between October, 1985 and May, 1987. Nineteen with pulmonary valve stenosis (PVS), three with small atrial septal defect (ASD) and one with ventricular septal defect (VSD); six with aortic valve stenosis (AVS); eight with Coarctation of the aorta (CoAo), in two with VSD and one with small ductus arteriosus; and four with rheumatic mitral stenosis (RMS). In PVS the peak systolic gradient (PSG) decreased significantly immediately after the procedure (92 +/- 40 vs 20 +/- 19 mmHg P less than 0.01). Nine patients were evaluated three months and seven one year later and no significant change occurred (19 +/- 11 and 20 +/- 19 mm Hg). The right ventricular systolic pressure (RVSP) and the ratio RVSP/left ventricular systolic pressure (LVSP) decreased immediately after the procedure (114 +/- 37 vs 69 +/- 36 mmHg P less than 0.15, and 0.98 +/- 0.29 vs 0.62 +/- 0.36, P less than 0.15). Three months later the RVSP and ratio RVSP/LVSP decreased more (57 +/- 16 mmHg, P less than 0.05, and 0.47 +/- 0.18, P less than 0.05) and one year later (54 +/- 27 mm Hg, P less than 0.05 and 0.46 +/- 0.24, P less than 0.05). In one case we repeated de dilatation one year later for restenosis. In CoAo PSG decreased immediately after dilation (59 +/- 21 vs 26 +/- 18 mmHg, P less than 0.1). Three months later the gradient was 38 +/- 20 mmHg. One patient was sent to surgery for significant residual gradient and one was dilated again 4 months after the first dilatation. One case was evaluated at cardiac catheterization one year later with gradient of 28 mmHg and blood pressure and femoral pulses were normal. In AVS PSG decrease immediately in all (91 +/- 25 vs 37 +/- 22 mmHg, P less than 0.02). Recatheterization in 4 patients three months later showed improvement in two. Two cases were sent to surgery for significant residual gradient. In these two patients we did not performed a dilatation because one had thrombosis in the puncture site and in the other we suspect subvalvular obstruction. The other two patients have shown clinical, echocardiographic and radiographic improvement.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

8.
Fourteen patients of pure valvular pulmonary stenosis of moderate to severe degree underwent balloon valvuloplasty in the Department of Cardiology, SSKM Hospital, Calcutta. Haemodynamic study revealed that immediately after valvuloplasty, right ventricular pressure dropped down from 125 +/- 17.18 mmHg. to 56.67 +/- 8.72 mmHg. (mean +/- SD). Restudy was done in each case after 4 weeks, which showed that right ventricular systolic pressure had further dropped down to 46.71 +/- 5.06 mmHg. (Mean +/- SD). Patients were further followed up for 6 to 15 months (mean 10 months). During the follow-up period, all the patients remained asymptomatic. Drop of right ventricular systolic pressure was maintained except in one case in which the peak systolic pressure gradient across the pulmonary valve was raised to 61 mmHg. from 24 mmHg., the gradient achieved immediately after valvuloplasty.  相似文献   

9.
The authors report three cases of congenital pulmonary stenosis in adults over 50 years of age treated by percutaneous balloon valvuloplasty. Three symptomatic women aged 74, 80 and 51, had systolic pressure gradients ranging from 107 to 113 mmHg between the right ventricle and pulmonary artery. After valvuloplasty with two balloons or one trefoil balloon, the transvalvular pressure gradient fell to 25 to 30 mmHg. It was only 14 mmHg in one patient controlled after one year's follow-up. The cardiac index was initially decreased and did not change very much immediately after the procedure, increasing from 1.68 1/m2/mn to 1.77 1/m2/mn. The pulmonary valve surface area increased from 0.22 to 0.43 cm2. There were no complications and in one patient, reviewed two years later, the clinical improvement was maintained. Percutaneous valvuloplasty is indicated in severe and/or poorly tolerated pulmonary stenosis. With the 10 other previously reported cases of patients over 50 years of age, the procedure was successful in 12 out of 13 patients (92%). In these patients of 51 to 80 years of age, the systolic pressure gradient between the right ventricle and pulmonary artery was reduced from 112 +/- 46 mmHg to 43 +/- 26 mmHg (-62%). Slight pulmonary regurgitation appeared in 5 out of 9 cases. Valvuloplasty was usually well tolerated and there were no fatalities. There were no signs of restenosis in 5 cases controlled 10 days to 1 year after dilatation. In the future, systematic Doppler echocardiographic examinations should help comparison of cardiac haemodynamics before, immediately after valvuloplasty and at long-term.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
The purpose of this study is to report our experience regarding the acute and intermediate-term results of balloon pulmonary valvuloplasty (BPV) in various types of congenital pulmonary valve stenosis. Methods and Results: Twenty-four consecutive patients with a median age of 6.6 years (ranging from 1 month to 24 years old) underwent BPV between January 1988 and September 1991. These patients were divided into 2 groups; Group 1 consisting of 13 patients with isolated pulmonary valve stenosis, and Group 2 consisting of 11 patients with complicated pulmonary valve stenosis (supravalvular, subvalvular, valved conduit and post-right ventricular outflow reconstruction). Mean peak systolic pressure gradients from the right ventricle to the pulmonary artery were as follows: In group 1, 48 +/- 21 (mean +/- SD) mmHg before BPV, 18 +/- 8 mmHg immediately after BPV and 13 +/- 5 mmHg at the longest follow-up based on catheterization or Doppler echocardiographic studies. The gradients in group 2 were 65 +/- 28 mmHg before BPV, 46 +/- 25 mmHg immediately after BPV and 47 +/- 21 mmHg at the longest follow-up. Conclusions: BPV provides both acute and intermediate-term gradient relief in patients with isolated pulmonary valve stenosis. In complicated pulmonary valve stenosis, on the other hand, the effect of BPV was unsatisfactory and appears to depend on the mechanism of associated obstruction. Therefore accurate evaluation of the anatomy of associated obstruction in the pulmonary valve region is needed to determine that BPV is indicated.  相似文献   

11.
The purpose of this study is the long term follow-up of the first pulmonary valvuloplasties performed by our group. From september 1984 to march 1988, 10 patients (4 men and 6 women) aged 8 to 58 (mean: 21) with severe or moderate pulmonary valve stenosis underwent pulmonary valvotomy. In all cases the balloon diameter was equal to or 1 mm smaller than the valvular annulus. The results were satisfactory with a significant mean gradient reduction of 51.7%. A follow-up gradient estimation by Doppler echocardiogram was obtained 10 to 37 months after valvuloplasty (mean: 23 months). The mean follow-up gradient by Doppler (31.3 +/- 9.9 mmHg) was not significantly different from the mean hemodynamic post-dilatation gradient (35.6 +/- 14.7 mmHg). A linear correlation was found between the post-dilatation hemodynamic mean gradient and the mean gradient by Doppler follow-up (r = 0.66, p less than 0.05, SEE = 4.1 mmHg). No restenosis were observed. These results suggest that the benefits of valvuloplasty are long lasting. Continuous Doppler is an excellent technique for the follow-up of these patients.  相似文献   

12.
BACKGROUND: Although pulmonary valvular stenosis is not uncommon in adults, there are few reports of percutaneous pulmonary valvuloplasty in adults, despite the possibility of avoiding heart surgery. AIM: This report describes the experience in adult patients undergoing this procedure and evaluates its effectiveness and tolerance. METHODS: Over an 8-year period (1989-1997), pulmonary valvuloplasty was considered in 22 adult patients [8 men, 14 women; mean age 28.0 years +/- standard deviation (SD) 10.3; range 16-46 years] with congenital pulmonary valve stenosis. Sixteen patients were asymptomatic with pulmonary systolic murmurs, although 6 patients presented with dyspnea. Before the procedure, the mean transpulmonary valve gradient was 53.2 +/- 24.8 mmHg SD, with a mean right ventricular systolic pressure of 74.6 +/- 28.4 mmHg SD, and mean pulmonary artery pressure was 21.4 +/- 6.4/10.2 +/-3.9 mmHg. RESULTS: The procedure was successful in 19 patients (6 men, 13 women) and was well tolerated and free of complications. Following the procedure, the mean transvalvular gradient was 15.5 +/- 11.5 mmHg, with a mean right ventricular systolic pressure of 40.5 +/- 13.6 mmHg and a mean pulmonary systolic pressure of 24.3 +/- 7.4 mmHg. This represented mean fall in transpulmonary valve gradient of 42.4 +/- 22.0 mmHg (paired t-test, p < 0.0001). After a mean follow-up of 20.1 months (13.4 SD), most patients remained well and asymptomatic, although two patients required repeat valvuloplasty. CONCLUSION: Pulmonary valvuloplasty is a well tolerated and effective treatment for pulmonary valve stenosis in adults, with few complications and no need for surgery. This procedure should be considered as the primary treatment of adult patients with pulmonary valve stenosis.  相似文献   

13.
53 patients affected by congenital valvular or discrete aortic stenosis have been evaluated in order to compare the observed gradient with the one expected according to multifactorial analysis based on electrocardiographic and auscultatory data deviced by Ellison et al. There Authors employed this formula for the evaluation of the valvular form only. In our experience all cases of valvular stenosis showing an estimated gradient less than or equal to 40 mmHg were found to have a gradient less than or equal to 40 mmHg at the catheterization. This statement is true in the discrete form as well, only if the estimated gradient was less than or equal to 30 mmHg. The regression curve between the two gradients shows a r = 0.718 (p less than 0.01); an even better correlation was found in the valvular forms (r = 0.816; p less than 0.01). These results are very useful since they allow to restrict indication to catheterization only to the cases in which the obstruction is estimated to necessitate a surgical intervention.  相似文献   

14.
Sixty two patients with moderate or severe stenosis of the pulmonary orifice (SPO) underwent balloon catheter valvuloplasty. Thirty one were aged under 5 years. The mean right ventricle-pulmonary artery trunk (RV-PAT) gradient fell from 75 (+/- 26) to 23 (+/- 10) mmHg (p less than 0.001). All dilatations except one were effective with only a few incidents and no mortality. Six (+/- 2) months later, hemodynamic evaluation of 45 patients (70%) showed stability of the RV-PAT gradient at 26 (+/- 18) as compared with 23 (+/- 11) mmHg. Ten patients required a second dilatation because of a residual gradient of greater than 35 mmHg. The result was favourable in all ten cases, the RV-PAT gradient falling from 53 (+/- 17) to 13 (+/- 8) mmHg (p less than 0.001). This series confirmed the efficacy, reproducibility and safety of this technique which led to a lowering of ventriculo-pulmonary gradient, persistent at six months, to an infra-surgical level, at the price of pulmonary incompetence (27%) which was always well tolerated in the mid-term. This valvuloplasty may be suggested for all cases of SPO with a gradient of greater than 35 mmHg.  相似文献   

15.
Aortic valvular dilatation with a balloon catheter was performed in 44 patients, 20 men and 24 women, most of whom were very elderly (average age 77 years). The indication for valvular replacement had not been retained in these cases because of surgical contra-indications or a very high operative risk and in 3 cases because of patient refusal. Twenty-nine patients were in functional classes III or IV of the NYHA classification; 12 had syncopal episodes and 18 had invalidating angina. The dilatation was performed by a femoral arterial approach in 34 cases, and by a brachial arterial approach in 10 cases. MEDI-TECH catheters with 15, 18 or 20 mm diameters when inflated were used in the majority of cases. Several inflations lasting 10 to 240 seconds were performed in each case with balloons of increasing size. This was well tolerated in all but one patients who had a sharp syncope. The immediate results confirmed valvular dilatation. The average transvalvular pressure gradient fell from 76 +/- 25 mmHg to 30 +/- 13 mmHg (p less than 0.001). The aortic valve surface area calculated by the Gorlin formula increased from 0.5 +/- 0.18 cm2 to 1 +/- 0.42 cm2 (p less than 0.01). After dilatation the gradient was less than or equal to 40 mmHg in 37 cases; aortic valve surface area was greater than or equal to 1 cm2 in 14 cases and less than or equal to 0.7 cm2 in only 5 cases. The left ventricular ejection fraction increased immediately after valvuloplasty from 44 +/- 16 p. 100 to 49 +/- 15 p. 100 (p less than 0.01). In the 18 cases in which it was less than 40 p. 100 before valvuloplasty, it increased from 30 +/- 6 p. 100 to 36 +/- 9 p. 100 (p less than 0.02). Residual aortic regurgitation was only observed in one case. Two patients died in the hospital period (4.6 p. 100). There were no other serious complications. During an average follow-up period of 60 days (3 weeks to 6 months) there was a big improvement in symptoms in the great majority of cases and, in particular, syncopal and anginal attacks disappeared. Only 4 patients remained in functional classes III or IV after valvuloplasty. Percutaneous aortic valvuloplasty is a new, relatively simple, low risk, economic and very effective therapeutic procedure in all cases in which aortic valve replacement is contra-indicated or refused by the patient.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

16.
Between 1984 and December 1990 balloon valvuloplasty for valvularpulmonary stenosis was planned and performed in 92 childrenover 6 months of age (range 0.8–17.9 years). Valvuloplastydecreased the invasively determined peak systolic gradient from61±34 (mean±SD) to 27±20 mmHg (P <0.0001At follow-up cardiac catheterization, performed in 22 patientsafter 13±5 months, the gradient was 22±23 mmHg(ns). Initially the continuous wave Doppler gradient decreasedfrom 61±23 to 26±12 mmHg (P <0.0001). It thenremained unchanged both at early follow-up after 0.6±0.3years, being 23±12 mmHg and at long-term follow-up after3±1.7 years (21±10 mmHg, ns). In the 41 patientstreated before the end of 1986 the residual continuous waveDoppler gradient at long-term follow-up after 5.1±0.8years was 21 ± 10 mmHg. Mild pulmonary regurgitationwas present in 77% of the patients at early follow-up and in83% at the last follow-up. Right ventricular hypertrophy onthe electrocardiogram was present in 83% of the children beforevalvuloplasty. At early follow-up it had decreased to 44% withafurther decrease to 24% at the last follow-up. Comparison of patients with initial invasive systolic gradientsgreater and smaller than 50 mmHg revealed no differences betweeneither group with regard to the continuous wave Doppler gradientat last follow-up, the incidence of pulmonary regurgitationand the occurrence of significant complications. Pulmonary balloon valvuloplasty can be safely and successfullyperformed in children over 6 months of age. Restenosis is rareand the relief of the gradient persists in the long-term. Pulmonaryregurgitation remains mild. The electrocardiogram is of littlevalue in the follow-up of these patients.  相似文献   

17.
Between December 1986 and August 1987, 34 patients referred for aortic valvuloplasty, undergo before catheterization an ultrasonocardiography with continuous and pulsed Doppler study and a phonocardiography for 22 of them. They all present functional and physical signs of aortic stenosis. The cardiac Doppler enables a positive diagnosis in all patients, while the phonocardiography recordings fail to recognize a tight aortic stenosis. On the other hand, the Doppler enables a diagnosis of severity well correlated with the catheterization (r = 0.88 for maximum instantaneous gradients) in 30 patients: in four patients, the correlation could not be calculated because of technical problems related to the catheterization (2 patients) or the ultrasonic examination (2 patients). From this study, it results that the cardiac Doppler may perfectly select patients who are to undergo an aortic valvuloplasty, unlike phonocardiography.  相似文献   

18.
We describe the first case of balloon pulmonary valvuloplasty performed in this country. This 12 year old girl had a transvalvular gradient of 94 mmHg and after the procedure it improved to 20 mmHg. Four months later, cardiac catheterization did not show any significative change in pulmonary valvular gradient (26 mmHg). We describe the technique, hemodynamic findings, complications, and advantages of this procedure. We also review the literature. We consider that balloon valvuloplasty should be the first choice procedure in the treatment of patients with congenital pulmonary valve stenosis.  相似文献   

19.
Long-term results after balloon pulmonary valvuloplasty   总被引:5,自引:0,他引:5  
B W McCrindle  J S Kan 《Circulation》1991,83(6):1915-1922
BACKGROUND. The objective of this study was to determine the long-term outcome of patients after percutaneous balloon pulmonary valvuloplasty (BPV) treatment of congenital pulmonary valve stenosis. METHODS AND RESULTS. This study represents a case series with duration (mean +/- SD) of follow-up of 4.6 +/- 1.9 years. Forty-six patients with a median age of 4.6 years (range, 3 months to 56 years) had BPV at one academic institution between June 1981 and December 1986. Mean peak systolic pressure gradients from the right ventricle to the pulmonary artery were as follows: before BPV, 70 +/- 36 mm Hg; immediately after BPV, 23 +/- 14 mm Hg; at intermediate follow-up by cardiac catheterization or Doppler echocardiography at less than 2 years after BPV, 23 +/- 16 mm Hg (n = 33); and at long-term follow-up by Doppler at more than 2 years after BPV, 20 +/- 13 mm Hg (n = 42). BPV acutely reduced the gradient to less than 36 mm Hg for 41 of 46 (89%) patients. Available gradients at long-term follow-up were less than 36 mm Hg for 36 of 42 (86%) patients without additional procedures. A patient age of less than 2 years at the initial BPV was a significant risk factor for gradients over 36 mm Hg at follow-up. CONCLUSIONS. BPV provides long-term relief of pulmonary valvular obstruction in the majority of patients. Close follow-up of patients who require BPV at less than 2 years of age is warranted.  相似文献   

20.
The purpose of this investigation was to evaluate the efficacy, technique, and follow-up results of balloon dilation angioplasty for valvular pulmonary stenosis. Percutaneous dilation was performed on 63 patients with pulmonary stenosis (ages 3 months to 76 years, mean = 4.3 years). In 43 patients, a single balloon was used; in 20 patients two balloons were used simultaneously. The pressure gradient across the pulmonary valve was determined with right ventricular and main pulmonary artery catheters. Pressure gradients simultaneously were estimated by continuous wave Doppler (CWD) during catheterization. The peak systolic ejection gradient was obtained by both techniques both pre- and postangioplasty. There was excellent linear correlation between the simultaneous catheter pressure gradient and the pressure gradient estimated by Doppler (r = 0.99). Follow-up pressure gradient estimations by Doppler echocardiogram were obtained in 30 patients between 6 months and 30 months postcatheterization (mean = 13 months). The mean preangioplasty gradient of 64 mm Hg (range 30-160 mm Hg) was reduced to 22 mm Hg (range 2-31 mm Hg). A significant reduction of transvalvular gradient (52-95%, mean 68%) occurred in each patient. A linear correlation was found between the predilation gradient and the pressure gradient drop (r = 0.92). Mean follow-up gradient by Doppler was 20 mm Hg (range 0-31 mm Hg), and there was no significant difference between these gradients and the postdilation gradient. No important complications were noted. These data confirm that balloon dilation angioplasty for valvular pulmonary stenosis is safe and effective, and suggest that stenosis does not recur.  相似文献   