首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Abstract

Introduction. Transcatheter aortic valve implantation (TAVI) is established as an attractive treatment option for high-risk patients with aortic valve stenosis. One concern is the high risk of prosthetic valve regurgitation. This study aimed to examine for potential preoperative risk factors for postprocedural transcatheter heart valve regurgitation and to quantify the risk, degree, and consequences of postprocedural regurgitation. Materials and methods. 100 consecutive patients who underwent femoral (n = 22) or transapical (n = 78) TAVI were retrospectively reviewed. Echocardiographic valve regurgitation and clinical parameters were analyzed over the first year after TAVI. Results. Seventy-five percent of all patients had prosthetic valve regurgitation. It was, however, only mild or absent in 64% of patients and did not require re-intervention in any of the patients in the series. The severity of the regurgitation appeared unchanged over the one-year follow-up period. Moderate to severe regurgitation was associated with significant yet stable dilatation of the left ventricle over one year and lesser NYHA class improvement three months after TAVI. Asymmetrical native valve calcification increased the risk of paravalvular regurgitation non-significantly. Conclusion. Transcatheter heart valve regurgitation seems to be mild in the majority of cases and unchanged over a 12 months follow-up period. While affecting left ventricular dimensions in moderate or severe cases, we observed no obvious undesirable consequences of the prosthetic valve regurgitation within the first year.  相似文献   

3.
4.
5.
Background and aim. It has been demonstrated that right ventricular systolic dysfunction develops soon after surgical aortic valve replacement (s-AVR). While the impact of s-AVR or TAVI on the function of the left ventricle has been studied with various imaging modalities, little is known about the impact on right ventricular function (RVF). In the current study, we evaluated the impact of TAVI on RVF using conventional echocardiography parameters. Methods and results. Echocardiography was performed prior to 24 h, 1 month and 6 months after TAVI. RVF was assessed using (1) tricuspid annular plane systolic excursion (TAPSE); (2) RV Tissue Doppler Imaging (S’); (3) right ventricular systolic pressure (RVSP); (4) Fractional area change (FAC); and (5) RV ejection fraction (RVEF). TAVI was performed through the subclavian artery in two patients and femoral artery in 48 patients with an Edwards Sapien XT valve. TAVI was performed on 50 patients between the dates of December 2012 and June 2013. After TAVI, a statistically significant improvement was observed for all parameters related to RVF (RVSP, RVEF, TAPSE, FAC, RVTDI S’). During the 1st and 6th months this statistically significant improvement continued in TAPSE and FAC, and there was no deterioration in RVSP, RVEF, and RVTDI S during the 1st month but a statistically significant improvement continued in the 6th month. Conclusion. RVF assessed by conventional echocardiography did not deteriorate after TAVI in early and midterm follow-up. Further, TAVI provides improvement of RVF and can safely and efficiently be performed in patients with impaired RVF.  相似文献   

6.
We thought that delirium might be less frequent after transcatheter aortic valve implantation via the femoral artery compared with via the cardiac apex. We reviewed 210 patients who underwent transcatheter aortic valve implantation between January 2009 and October 2014. The proportion (95% CI) of patients who suffered delirium in the 3 days after valve implantation were: 10 (3–16%) in 105 patients who had transfemoral implantation; and 35 (25–45%) in 105 patients who had transapical implantation, p = 0.0001. The variables that independently associated with postoperative delirium were age, male sex and the transapical approach. The median (IQR [range]) hospital stay was 7 (5–13 [2–41]) days and 10 (7–15 [2–64]) days, respectively, p = 0.004. Future trials should focus on different peri‐operative management strategies to reduce delirium rates after transcatheter aortic valve implantation, particularly in older men having implantations via the cardiac apex.  相似文献   

7.
8.
9.
10.
11.

Background

Bicuspid aortic valve (BAV) stenosis has been considered a relative contraindication to transcatheter aortic valve replacement (TAVR). We compared the outcomes of TAVR in patients with BAV stenosis versus patients with trileaflet aortic valve stenosis.

Methods

From March 2012 to September 2017, 727 patients underwent TAVR. Thirty‐two patients with BAV were included in this study and compared to 96 patients with comparable risk factors (1:3) with a trileaflet aortic valve (TAV). Transesophageal echocardiography was used to estimate post‐TAVR degree of paravalvular leak (PVL).

Results

Mean ± standard deviation Society of Thoracic Surgeons risk was 6.01 ± 3.42 in the BAV group and 6.08 ± 3.76 in the TAV group (P = 0.92). Thirty‐day mortality was 4.2% (N = 4) in the TAV group and 6.25% (N = 2) in the BAV group (P = 0.63). Three (3.1%) patients in the TAV group and two (6.25%) patients in the BAV group developed a post operative stroke (P = 0.59). Following TAVR, mean aortic valve gradient significantly decreased in both TAV (42.56 ± 14.93 vs 9.27 ± 5.57, P < 0.001) and BAV (44.12 ± 11.82 vs 9.03 ± 7.29, P < 0.001) groups. No patient had a severe PVL after TAVR, and only two (2.08%) patients in the TAV group and one (3.12%) patient in the BAV group had moderate PVL (P = 1.0). Patient survival rate at 1 and 2 years was 86% in the BAV group and 90% at 1 and 2 years in the TAV group (P = 0.74).

Conclusions

TAVR in BAV disease is feasible with favorable valve performance. Immediate and mid‐term outcomes of TAVR in patients with BAV are comparable to those with TAV.  相似文献   

12.
Aim: Transcatheter aortic valve implantation (TAVI) poses a significant risk of acute kidney injury (AKI). Little is known of the impact of TAVI and AKI on long‐term kidney function and health cost. We explored the predictive factors and prognostic implications of AKI following TAVI. Methods: Single‐centre retrospective analysis of 52 elderly patients undergoing TAVI was conducted. The primary endpoint was renal outcome which included the incidence of AKI and 12‐month renal function after TAVI. Secondary endpoints were mortality, the length of hospital stay (LOS) and cost. Results: AKI occurred in 15/52 (28.8%) patients (mean age 84 ± 6) and three patients (6%) required dialysis. Patients with AKI (AKI+) had greater comorbidity (diabetes and cerebrovascular disease) and a trend towards reduced estimated glomerular filtration rate (eGFR) at baseline compared with those without AKI (56.6 vs AKI?: 65.7 mL/min per 1.73 m2, P = 0.07). Following TAVI, AKI? patients experienced an immediate improvement in eGFR, which remained significantly higher at all time points compared with AKI+ patients (70.4 vs 46.9 at 6 months and 73.7 vs 53.0 at 12 months, P < 0.001). Cumulative mortality for AKI+versus AKI? group was 26.7% and 2.7% (P = 0.006). LOS doubled (P < 0.001) and average hospitalization cost per patient was 1.5 times higher in the AKI+ group (P < 0.001). Independent predictors of AKI were peri‐procedural blood transfusion (OR: 2.4, 95% CI: 2.0–3.1), trans‐apical approach (OR: 9.3, 95% CI: 4.3–23.7) and hypertension (OR: 6.4, 95% CI: 2.9–17.3). Conclusion: AKI developed in 28.8% of patients after TAVI and was associated with procedural technique and transfusion requirement, and an increased LOS and mortality. However, most patients achieved a significant and sustained improvement in eGFR.  相似文献   

13.

Objective

Native aortic valve calcium and transcatheter aortic valve oversize have been reported to predict pacemaker implantation after transcatheter aortic valve insertion. We reviewed our experience to better understand the association.

Methods

We retrospectively reviewed the records of 300 patients with no prior permanent pacemaker implantation who underwent transcatheter aortic valve insertion from November 2008 to February 2015. Valve oversize was calculated using area. The end point of the study was 30-day postoperative pacemaker implantation.

Results

Patient data included age of 81.1 ± 8.4 years, female sex in 135 patients (45%), atrial fibrillation in 74 patients (24.7%), Society of Thoracic Surgeons predicted risk of mortality of 7.6% (interquartile range [IQR], 5.3-10.6), aortic valve calcium score of 2568 (IQR, 1775-3526) Agatston units, and annulus area of 471 ± 82 mm2. Balloon-expandable valves were inserted in 244 patients (81.3%). Transcatheter aortic valve oversize was 12.8% (IQR, 3.9-23.3). Pacemaker implantation was performed in 59 patients (19.7%). Aortic valve calcium score (adjusted P = .275) and transcatheter valve oversize (adjusted P = .833) were not independent risk factors for pacemaker implantation when controlling for preoperative right bundle branch block (adjusted odds ratio, 3.49; 95% confidence interval, 1.61-8.55; P = .002), implantation of self-expanding valve (adjusted odds ratio, 4.09; 95% confidence interval, 1.53-10.96; P = .005), left bundle branch block (adjusted P = .331), previous percutaneous coronary intervention (adjusted P = .053), or valve surgery (adjusted P = .111), and PR interval (adjusted P = .350).

Conclusions

Right bundle branch block and implantation of a self-expanding prosthesis were predictive of pacemaker implantation, but not native aortic valve score or transcatheter valve oversize.  相似文献   

14.
背景 对于有临床症状的严重主动脉瓣狭窄患者而言,实施标准主动脉瓣置换术(surgical aortic valve replacement,SAVR)可能有禁忌或高风险.经导管主动脉瓣植入术(transcatheter aortic valve implantation,TAVI)是一种可供选择的治疗方式. 目的 阐述TAVI围手术期的麻醉管理与监测. 内容 实施TAVI患者的术前评估、风险分级、麻醉的准备和麻醉方法的选择以及行TAVI术中和术后监测管理. 趋向 设备更新与开发、进一步的研究和经验的积累将促使TAVI成为一种在心脏导管室开展的经皮入路微创手术,以后可以更加广泛地应用于有手术禁忌、合并并发症以及严重、不稳定心脏病的危重主动脉瓣狭窄患者.  相似文献   

15.
In patients with previous heart surgery, the operative risk is elevated during conventional aortic valve re-operations. Trans-catheter aortic valve implantation is a new method for the treatment of high-risk patients. Nevertheless, this new procedure carries potential risks in patients with previous homograft implantation in aortic position. Between April 2008 and February 2011, 345 consecutive patients (mean EuroSCORE (European System for Cardiac Operative Risk Evaluation): 38 ± 20%; mean Society of Thoracic Surgeons (STS) Mortality Score: 19 ± 16%; mean age: 80 ± 8 years; 111 men and 234 women) underwent trans-apical aortic valve implantation. In three patients, previous aortic homograft implantation had been performed. Homograft degeneration causing combined valve stenosis and incompetence made re-operation necessary. In all three patients, the aortic valve could be implanted using the trans-apical approach, and the procedure was successful. In two patients, there was slight paravalvular leakage of the aortic prosthesis and the other patient had slight central leakage. Neither ostium obstruction nor mitral valve damage was observed. Trans-catheter valve implantation can be performed successfully after previous homograft implantation. Particular care should be taken to achieve optimal valve positioning, not to obstruct the ostium of the coronary vessels due to the changed anatomic situation and not to cause annulus rupture.  相似文献   

16.
17.
18.
19.
20.
经导管主动脉瓣置换术麻醉进展   总被引:1,自引:0,他引:1  
背景 对于手术禁忌或高风险手术的重度主动脉瓣狭窄患者,经导管主动脉瓣植入术(transcatheter aortic valve implantation,TAVI)已作为开放性手术的替代疗法.麻醉是保证手术成功的关键. 目的 总结目前关于TAVI麻醉监测管理的最新进展,为临床医师提供参考. 内容 从术前评估、麻醉方法、术中监测、术中以及术后管理等5个方面综述TAVI的麻醉进展. 趋向 目前国内TAVI麻醉研究较少,麻醉医师安全有效地监测管理是保证手术成功的关键因素.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号