首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Jung JY  Jee WH  Park MY  Lee SY  Kim YS 《Skeletal radiology》2012,41(11):1401-1410

Objective

To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0?T.

Materials and methods

The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0?T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement (κ) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone.

Results

There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE.

Conclusion

Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears.  相似文献   

2.

Objective

The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard.

Materials and methods

In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small (<1 cm), medium (1-3 cm), and large (>3 cm).

Results

The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears.

Conclusion

Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears.  相似文献   

3.
We assessed the diagnostic performance of magnetic resonance (MR) arthrography in the diagnosis of articular-sided partial-thickness and full-thickness rotator cuff tears in a large symptomatic population. MR arthrograms obtained in 275 patients including a study group of 139 patients with rotator cuff tears proved by arthroscopy and a control group of 136 patients with arthroscopically intact rotator cuff tendons were reviewed in random order. MR imaging was performed on a 1.0 T system (Magnetom Expert, Siemens). MR arthrograms were analyzed by two radiologists in consensus for articular-sided partial-thickness and full-thickness tears of the supraspinatus, infraspinatus, and subscapularis tendons. At arthroscopy, 197 rotator cuff tears were diagnosed, including 105 partial-thickness (93 supraspinatus, nine infraspinatus, three subscapularis) and 92 full-thickness (43 supraspinatus, 20 infraspinatus, 29 subscapularis) tendon tears. For full-thickness tears, sensitivity, specificity, and accuracy were 96%, 99%, and 98%, respectively, and for partial tears 80%, 97%, and 95%, respectively. False negative and positive assessments in the diagnosis of articular-sided partial-thickness tears were predominantly [78% (35/45)] observed with small articular-sided (Ellman grade1) tendon tears. MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears and is accurate in the diagnosis of articular-sided partial-thickness tears. Limitations in the diagnosis of partial-thickness tears are mainly restricted to small articular-sided tears (Ellman grade 1) due to difficulties in differentiation between fiber tearing, tendinitis, synovitic changes, and superficial fraying at tendon margins.  相似文献   

4.
目的:比较常规MRI和MRI间接关节造影检查对肩袖撕裂伤的诊断价值.方法:搜集2002年11月~2006年8月共40例肩袖损伤病例,20例行常规MRI检查,20例行MRI间接关节造影检查.以肩关节镜作为诊断标准,比较两种影像学方法诊断肩袖损伤的敏感性和特异性.结果:肩袖完全撕裂中,常规MRI检查的敏感度为45.5%,特异度为66.7%,准确度为55%;MRI间接关节造影的敏感度为92.3%,特异度为85.7%,准确度为90%.肩袖不全撕裂中,常规MRI检查敏感度为57.1%,特异度为53.8%,准确度为55%;而间接关节造影敏感度为83.3%,特异度为92.8%,准确度则为90%.经Fisher确切概率统计法统计,MRI间接关节造影诊断肩袖全层撕裂敏感性及准确性明显高于常规MRI(P<0.05),在诊断肩袖部分撕裂时,MRI间接关节造影的特异性及准确性明显高于MRI(P<0.05).结论:MRI间接关节造影较常规MRI诊断肩袖撕裂准确性较高.同时对盂唇等其它病变诊断有帮助.  相似文献   

5.
Purpose: To compare the diagnostic performance of multidetector computed tomographic (CT) arthrography and 1.5-T magnetic resonance (MR) arthrography in the evaluation of rotator cuff lesions, with arthroscopic correlation. Materials and Methods: This study was approved by the institutional ethical committee, and informed consent was obtained from all patients. CT and MR arthrographic images prospectively obtained in 56 consecutive patients, following the same arthrographic procedure, were independently evaluated by two radiologists. Arthroscopy, performed within 1 month of the imaging, was used as the reference standard. Sensitivity and specificity of CT and MR arthrography were compared by using the McNemar test. Interobserver and intertechnique agreement for detecting rotator cuff lesions were measured and compared with κ and Z statistics. The Bland-Altman method was used to determine interobserver and intertechnique agreement for measuring tendon tears. For grading fatty infiltration of rotator cuff muscles, κ and Z statistics were used. Results: There was no statistically significant difference in sensitivity and specificity between CT arthrography and MR arthrography in depiction of rotator cuff lesions. The respective sensitivity and specificity of CT arthrography were 92% and 93%-97% for the supraspinatus, 100% and 77%-79% for the infraspinatus, 75%-88% and 85%-90% for the subscapularis, and 55%-65% and 100% for the biceps tendon. The respective sensitivity and specificity of MR arthrography were 96% and 83%-93% for the supraspinatus, 88%-100% and 81%-83% for the infraspinatus, 75%-88% and 90%-100% for the subscapularis, and 65%-85% and 100% for the biceps tendon. Interobserver agreement was substantial to almost perfect (κ = 0.744-0.964 for CT arthrography; κ = 0.641-0.893 for MR arthrography), and intertechnique agreement was almost perfect (κ > 0.819). CT and MR arthrography both yielded moderate interobserver and intertechnique agreement for measuring rotator cuff tears and grading muscle fatty infiltration. Conclusion: Data suggest that CT and MR arthrography have similar diagnostic performance for the evaluation of rotator cuff tendon tears. ? RSNA, 2012.  相似文献   

6.
The objective of this study was to assess the value of adding MR arthrography to standard MRI for patients with chronic wrist disorders. Thirty consecutive patients (age range, 19–73 years; mean, 36.2 years) were included in the investigation. The images were evaluated blindly and separately by two radiologists with regard to lesions of the scapholunate (SL) and lunotriquetral (LT) ligaments and the triangular fibrocartilage (TFC). Conventional two- or three-compartment arthrography was used as the standard of reference. For TFC lesions, standard MR images had a sensitivity of 92.3% (reader 1) and 84.6% (reader 2) and a specificity of 41.2% (reader 1) and 52.9% (reader 2). For MR arthrography, sensitivity was 84.6% (reader 1) and 84.6% (reader 2) and specificity was 88.2% (reader 1) and 100% (reader 2). For SL ligament tears, standard MRI had a sensitivity of 33.3% (reader 1) and 11.1% (reader 2) and a specificity of 47.6% (reader 1) and 57.1% (reader 2). For MR arthrography, sensitivity was 66.7% (reader 1) and 55.6% (reader 2) and specificity was 52.4% (reader 1) and 81.0% (reader 2). For LT ligament tears, standard MRI had a sensitivity of 28.6% (reader 1) and 35.7% (reader 2) and a specificity of 93.8% (reader 1) and 81.3% (reader 2). For MR arthrography, sensitivity was 35.7% (reader 1) and 23.1% (reader 2) and specificity was 93.8% (reader 1) and 94.1% (reader 2). In conclusion, the diagnostic performance of MRI in suspected lesions of the TFC and the SL and LT ligaments is improved by adding MR arthrography to the standard examination.  相似文献   

7.
OBJECTIVE: We sought to compare the diagnostic accuracy of conventional MRI versus MR arthrography of the shoulder in the assessment of high-performance athletes (professional baseball players) and to compare our findings in these patients with the conventional MRI and MR arthrographic findings in an age-matched control group of nonprofessional athletes. MATERIALS AND METHODS: Conventional MRI and MR arthrographic examinations of the shoulder in 20 consecutive professional baseball players with shoulder pain were reviewed retrospectively by two musculoskeletal radiologists in consensus. These interpretations were compared with retrospective consensus interpretations of conventional MRI and MR arthrographic examinations of the shoulder obtained in a control group of 50 consecutive nonprofessional athletes with shoulder pain. MR images were assessed for full- or partial-thickness supraspinatus tendon tears, superior labral anteroposterior (SLAP) tears, and anterior or posterior labral tears. RESULTS: In the 20 consecutive professional athlete patients, two full-thickness and six partial-thickness undersurface supraspinatus tendon tears were seen on MR arthrography but not seen on conventional MRI as well as six SLAP tears, two anterior labral tears, and one posterior labral tear. Three patients had both SLAP tears and full- or partial-thickness supraspinatus tendon tears. Of 14 patients with findings on MR arthrography that were not seen on MRI, 11 had arthroscopic correlation. In all 11, arthroscopic findings confirmed findings on MR arthrography. In the group of 50 nonprofessional athlete patients, five had additional findings on MR arthrography not seen on conventional MRI: two anterior labral tears, two partial-thickness supraspinatus tendon tears, and two SLAP tears. One patient had both a partial-thickness supraspinatus tendon tear and a SLAP tear seen on MR arthrography. The five patients with additional findings on MR arthrography had arthroscopy. In all five, arthroscopic findings confirmed the findings on MR arthrography. CONCLUSION: MR arthrography is considerably more sensitive for detection of partial-thickness supraspinatus tears and labral tears than conventional MRI. MR arthrography showed injuries in addition to those seen on conventional MRI in 14 of 20 patients in the high-performance athlete group. These results suggest high-performance athletes may be a subgroup of patients for whom MR arthrography yields considerably more diagnostic information than conventional MRI.  相似文献   

8.

Objective

To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings.

Materials and Methods

The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articular-sided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the inter- and intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears.

Results

The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal-sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate.

Conclusion

MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and both articular- and bursal-sided tears. In addition, it shows only fair inter-observer agreement when it comes to predicting both articular- and bursal-sided tears.  相似文献   

9.
OBJECTIVE: The objective of this study was to investigate the diagnostic performance of MR arthrography after rotator cuff repair. MATERIALS AND METHODS: MR arthrographic examinations of the shoulder performed after rotator cuff repair and before revision surgery were retrospectively analyzed in 48 patients (31 males, 17 females; mean age, 50.3 years; age range, 17-69 years). Full-thickness and partial-thickness defects of the supraspinatus, infraspinatus, and subscapularis tendons were diagnosed independently by two radiologists. Revision surgery served as the standard of reference. RESULTS: Observer 1 correctly recognized five of eight intact supraspinatus tendons, 10 of 19 partial-thickness defects, and 19 of 21 full-thickness defects. For observer 2, the numbers were three of eight, eight of 19, and 18 of 21. The corresponding numbers for the infraspinatus tendon for observer 1 were 28 of 31, 0 of three, and 14 of 14 tendons. For observer 2, they were 28 of 31, two of three, and 11 of 14. For the subscapularis tendon, observer 1 made the correct diagnosis in 18 of 31, five of six, and nine of 11 tendons. The results for observer 2 were 26 of 31, one of six, and 10 of 11 tendons. Interobserver agreement (weighted kappa) was 0.47 for the supraspinatus, 0.64 for the infraspinatus, and 0.20 for the subscapularis tendons, respectively. CONCLUSION: Postoperative full-thickness defects of the rotator cuff are reliably diagnosed with MR arthrography. The diagnostic performance for partial-thickness defects is only moderate.  相似文献   

10.
肩关节MR造影对肩关节前方盂唇病变的诊断价值   总被引:3,自引:0,他引:3  
目的明确肩关节造影MR对肩关节前方盂唇病变的诊断价值,并比较中立位肩关节造影MR和外展外旋(abduction and external rotation, ABER)造影MR的价值。方法回顾性分析经证实的44例肩关节造影MR资料,以肩关节镜检查结果为金标准,对比中立位肩关节造影MR和ABER造影MR对肩关节前方盂唇病变的诊断价值。结果中立位肩关节造影MR对前方盂唇的诊断敏感度为79.3%(23/29),特异度为100%(15/15),准确度为86.4%(38/44);ABER造影MR的敏感度为93.1%(27/29),特异度为100%(15/15),准确度为95.5%(42/44)。ABER造影MR显著提高了前方盂唇病变的诊断敏感度(P=0.037)。结论ABER造影MR可以提高肩关节前方盂唇病变的诊断敏感度。  相似文献   

11.

Purpose  

The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability.  相似文献   

12.
PURPOSE: To assess the practical utility of isotropic shoulder imaging in patients undergoing MR arthrography. Isotropic shoulder imaging can be performed in less than three minutes with use of fast gradients. MATERIALS AND METHODS: Two experienced musculoskeletal radiologists retrospectively interpreted MR images of the shoulder in 100 consecutive patients undergoing MR arthrography of the shoulder. All patients underwent MRI of the shoulder in oblique coronal, oblique sagittal, and axial planes on a 3.0-Tesla MRI system. All patients had conventional fast spin-echo T1-weighted imaging. All patients also had thin section (0.4 mm) isotropic spoiled gradient echo images performed. A total of 67 of the 100 patients underwent subsequent arthroscopy and results were compared with MR interpretations. RESULTS: There were 41 full-thickness supraspinatus tendon tears, nine partial-thickness supraspinatus tendon tears (seven articular surface and two bursal surface), 21 superior labral, 18 anterior labral, and seven posterior labral tears demonstrated by consensus retrospective reading of the 100 shoulder MR exams. There was no difference in interpretation of the isotropic images as compared to the conventionally acquired images in the oblique coronal, oblique sagittal, and axial planes. Some patients had more than one finding on each exam. A total of 67 patients went on to arthroscopy. There were 41 full-thickness supraspinatus tendon tears, nine partial-thickness supraspinatus tendon tears, 21 superior labral, 18 anterior labral, and seven posterior labral tears demonstrated on arthroscopy. All full- and partial-thickness supraspinatus tendon tears seen at arthroscopy were seen on consensus MR reading. A total of 19 out of the 21 patients with superior labral anterior posterior (SLAP) tears at arthroscopy were seen on consensus MR reading. A total of 16 of the 18 anterior labral tears and six of the seven posterior labral tears seen at arthroscopy were seen on consensus MR reading. Some of the 67 patients had more than one finding on arthroscopy. CONCLUSION: Isotropic imaging of the shoulder is practical in clinical imaging when performed with use of fast gradients on a 3-Tesla system. Isotropic imaging provides the same clinical information as conventional imaging and can be acquired in less than three minutes.  相似文献   

13.
Lee SY  Lee JK 《Radiology》2002,224(2):470-476
PURPOSE: To determine the characteristics of horizontal components of partial-thickness tears of the rotator cuff at magnetic resonance (MR) arthrography and to determine whether use of the abduction and external rotation (ABER) position improved detection of a horizontal component in partial-thickness tears. MATERIALS AND METHODS: MR studies in 16 patients (mean age, 32 years) who had partial-thickness tear with a horizontal component were retrospectively evaluated. All 16 patients had undergone arthroscopic surgery. The depth and extent of the horizontal component were measured on MR images, and the presence or absence of articular surface tear was recorded. The characteristics of the horizontal component on ABER views were compared with those on oblique coronal views. RESULTS: A horizontal component (24 lesions; one tendon involved in eight patients and two tendons involved in eight patients) was observed in 100% of the lesions on ABER views and in 21% of the lesions (n = 5) on oblique coronal images. The mean length of the horizontal components, measured on ABER views, was 1.9 cm (range, 0.6-4.5 cm). Thirteen (54%) of the 24 lesions were classified as grade I (<3 mm) in depth, four (17%) were classified as grade II (3-6 mm), and seven (29%) were classified as grade III (>6 mm). Articular separation sites with a flap lesion were visualized in 15 (62%) of 24 lesions on ABER views. CONCLUSION: MR arthrography of the shoulder with patients in the ABER position may provide additional information in cases of partial-thickness tears of the rotator cuff with a horizontal component.  相似文献   

14.
PURPOSE: To determine which US signs are important in the diagnosis of a surgically identifiable supraspinatus tendon tear. MATERIALS AND METHODS: Fifty consecutive ultrasonographic (US) studies of the shoulder in patients who underwent arthroscopic follow-up were retrospectively reviewed by a musculoskeletal radiologist. US images of the supraspinatus tendon were evaluated for tendon nonvisualization, abnormal tendon echogenicity, tendon thinning, greater tuberosity cortical irregularity, cartilage interface sign, joint fluid, and subacromial-subdeltoid bursal fluid. US findings were compared with arthroscopic results. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated for each US sign in the diagnosis of full-thickness tendon tear and again for any type of supraspinatus tendon tear. RESULTS: Arthroscopy revealed 21 full-thickness tears, five bursal surface partial-thickness tears, 10 articular surface partial-thickness tears, and 14 patients without tear of the supraspinatus tendon. The presence of greater tuberosity cortical irregularity and joint fluid was most important in the diagnosis of full-thickness supraspinatus tendon tear (sensitivity, 60%; specificity, 100%; positive predictive value, 100%; negative predictive value, 78%; accuracy, 84%). For diagnosis of any type of supraspinatus tendon tear (partial or full thickness), tendon nonvisualization, greater tuberosity cortical irregularity, and cartilage interface sign are most important, although a combination of signs did not improve accuracy. CONCLUSION: Secondary US signs, such as greater tuberosity cortical irregularity and joint fluid, are most valuable in the diagnosis of supraspinatus tendon tear.  相似文献   

15.
PURPOSE: To determine the reliability and accuracy of magnetic resonance (MR) arthrography for the diagnosis of superior labral anterior posterior (SLAP) tears. MATERIALS AND METHODS: The MR arthrograms in 80 patients who underwent arthroscopy and MR arthrography during a 54-month period were retrospectively reviewed. MR arthrograms were independently scored by three observers for the presence and type of SLAP lesion. Type I SLAP lesions were regarded as negative as they most often are not clinically relevant. Interobserver agreement for detection of SLAP lesions was calculated by using kappa coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate z score test. RESULTS: At arthroscopy, there were 25 SLAP tears: type II (n = 22), type III (n = 2), and type IV (n = 1). Sensitivity, specificity, and accuracy of each reader were 92%, 84%, and 86%; 92%, 82%, and 85%; and 84%, 69%, and 74%, respectively. Interobserver agreement for SLAP tears was substantial (kappa = 0.77) to moderate (kappa = 0.52, kappa = 0.44). The areas under the ROC curves for each reader were 0.94, 0.93, and 0.83, which were not significantly different. CONCLUSION: MR arthrography of the shoulder is reliable and accurate for detection of SLAP tears.  相似文献   

16.

Purpose

We report the prevalence of supraspinatus tendon tears seen on MR arthrography that are not seen on conventional MR exam in the same patient population.

Materials and methods

A total of 150 consecutive conventional shoulder MR and MR arthrography exams performed on the same patients who went on to arthroscopy were reviewed retrospectively by consensus reading of two musculoskeletal radiologists. Full-thickness supraspinatus tendon tears were assessed. None of the patients had previous shoulder surgery.

Results

There were 113 full-thickness supraspinatus tendon tears seen on conventional MR exam while there were 119 full-thickness supraspinatus tendon tears seen on MR arthrography. The six additional full-thickness supraspinatus tendon tears seen on MR arthrography but not seen on conventional MR exam were confirmed at arthroscopy.

Conclusions

Some full-thickness supraspinatus tendon tears are not seen on conventional MR exam but are seen on MR arthrography. This is most likely due to fibrosis at the supraspinatus tendon tear site simulating an intact tendon on conventional MR.  相似文献   

17.
This article reviews the examination technique of shoulder ultrasound, normal and abnormal ultrasound findings in acute (posttraumatic) and chronic (degenerative) lesions. Moreover, it reviews the effectiveness of ultrasound in relation to magnetic resonance (MR) imaging. Most authors report that full-thickness tears of the supraspinatus can reliably be diagnosed by ultrasound. However, the simple diagnosis of a full-thickness rotator cuff tear is no longer sufficient for surgical management. The precise localization and size of rotator cuff tears as well as the extent of muscle degeneration is important for surgical planning. For this aspect and for partial-thickness tears of the supraspinatus, for subscapularis lesions as well as for lesions of the long biceps tendons there is no consensus regarding the diagnostic value of ultrasound. To the present, ultrasound (contrary to MR imaging) has failed to demonstrate that it consistently influences the clinician's degree of confidence in the clinical diagnosis or the treatment plan. Therefore, some orthopedic surgeons prefer MR imaging to ultrasound in the evaluation of rotator cuff tears and other abnormalities of the glenohumeral joint. Moreover, MR imaging, especially when combined with arthrography, represents a one-step investigation, which not only allows for assessment of rotator cuff lesion but also of lesions of the labrum (Bankart lesions, SLAP lesions), the joint capsule and the biceps tendon. It also demonstrates muscle atrophy, which represents an important predictor of surgical outcome in rotator cuff repair.  相似文献   

18.
PURPOSE: To evaluate proton magnetic resonance (MR) spectroscopy in the assessment of lipid content of the supraspinatus muscle in asymptomatic volunteers and patients with supraspinatus tendon lesions. MATERIALS AND METHODS: Single-voxel proton MR spectroscopy was used to assess lipid content of the supraspinatus muscle in asymptomatic volunteers (n = 30) and patients with partial-thickness supraspinatus tendon tears (n = 30), newly diagnosed full-thickness supraspinatus tendon tears (n = 30), and chronic full-thickness supraspinatus tendon tears (n = 30). The apparent lipid content of the supraspinatus muscle measured with proton MR spectroscopy was related to its appearance on sagittal-oblique T1-weighted spin-echo MR images (grades 0-4). One-way analysis of variance was performed to test for significant differences, and the Tukey honestly significant difference procedure was performed for post hoc comparisons. RESULTS: Mean apparent lipid content was 13.7% (95% confidence interval [CI]: 11.5%, 15.8%) for asymptomatic volunteers, 29.5% (95% CI: 25.1%, 34.0%) for patients with partial-thickness tears, 48.6% (95% CI: 41.3%, 55.9%) for patients with full-thickness tears, and 66.1% (95% CI: 57.7%, 74.5%) for patients with chronic tears. Values were significantly different (analysis of variance, P <.001; P <.001-.002 for all post hoc pairwise comparisons). Mean apparent lipid content for the supraspinatus muscle was as follows: grade 0, 19.6% (95% CI: 16.7%, 22.6%); grade 1, 36.8% (95% CI: 33.2%, 40.4%); grade 2, 53.6% (95% CI: 43.1%, 64.2%); grade 3, 67.5% (95% CI: 52.6%, 82.3%); and grade 4, 79.2% (95% CI: 73.2%, 85.3%). With analysis of variance (P <.001), all post hoc pairwise comparisons were significant (P 相似文献   

19.
肩关节损伤的MR影像诊断   总被引:1,自引:0,他引:1  
目的 探讨常规MRI和MR间接关节造影对肩关节损伤的诊断价值.方法 回顾分析经关节镜证实的90例肩关节损伤患者肩关节常规MRI和MR问接关节造影表现,其中肩袖病变组57例、盂肱关节不稳组33例.对常规MRI和MR间接关节造影诊断结果进行Fisher确切概率法比较.结果 (1)肩袖病变组中MR间接关节造影37例,显示部分撕裂10例,1例漏诊;显示完全撕裂17例,2例误诊,7例肩袖无撕裂.MR间接关节造影显示部分撕裂的敏感度、特异度、准确度分别为90.9%(10/11)、92.3%(24/26)、91.9%(34/37);显示完全撕裂的敏感度、特异度、准确度分别为89.5%(17/19)、94.4%(17/18)、91.9%(34/37).MR间接关节造影诊断肩袖部分及完全撕裂的敏感度及准确度均高于常规MRI(P<0.05).(2)盂肱关节不稳组中,盂唇损伤26例,Hill-sachs病变27例、反Hill-sachs病变2例、骨陛Bankart损伤7例、关节囊损伤18例.间接关节造影20例,显示盂唇损伤14例,1例漏诊,5例正常.MR间接关节造影显示盂唇损伤的敏感度、特异度、准确度分别为93.3%(14/15)、100.0%(5/5)、95.0%(19/20).前者诊断盂唇损伤的敏感度及准确度明显高于常规MRI(P<0.05).结论 MR检查特别是MR间接关节造影能够准确显示肩关节常见病变及相关组织的病理发展过程,为临床诊断及治疗提供影像学依据.  相似文献   

20.

Objective

To compare the accuracy between a three-dimensional (3D) indirect isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) arthrography and a conventional two-dimensional (2D) T1-weighted sequences of indirect MR arthrography for diagnosing rotator cuff tears.

Materials and Methods

The study was approved by our Institutional Review Board. In total, 205 patients who had undergone indirect shoulder MR arthrography followed by arthroscopic surgery for 206 shoulders were included in this study. Both conventional 2D T1-weighted FSE sequences and 3D isotropic T1-weighted FSE sequence were performed in all patients. Two radiologists evaluated the images for the presence of full- or partial-thickness tears in the supraspinatus-infraspinatus (SSP-ISP) tendons and tears in the subscapularis (SSC) tendons. Using the arthroscopic findings as the reference standard, the diagnostic performances of both methods were analyzed by the area under the receiver operating characteristic curve (AUC).

Results

Arthroscopy confirmed 165 SSP-ISP tendon tears and 103 SSC tendon tears. For diagnosing SSP-ISP tendon tears, the AUC values were 0.964 and 0.989 for the 2D sequences and 3D T1-weighted FSE sequence, respectively, in reader I and 0.947 and 0.963, respectively, in reader II. The AUC values for diagnosing SSC tendon tears were 0.921 and 0.925, respectively, for reader I and 0.856 and 0.860, respectively, for reader II. There was no significant difference between the AUC values of the 2D and 3D sequences in either reader for either type of tear.

Conclusion

3D indirect isotropic MR arthrography with FSE sequence and the conventional 2D arthrography are not significantly different in terms of accuracy for diagnosing rotator cuff tears.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏