首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 218 毫秒
1.
目的探讨活化血浆凝固时间(APCT)对血小板减低所致出血的预示价值及输注疗效的评估价值。方法血液病患者40名血小板计数(Plt)均<50×109/L,其中有散在出血点或鼻衄症状的24例,无出血症状的16例,有22例进行了血小板输注(其中21例有出血症状)。抽取患者静脉血,以3.8%的拘橼酸钠抗凝后,测定Plt和APCT。结果出血组患者的APCT与未出血组相比明显延长,出血组和未出血组的Plt和APCT分别为(7.9±3.4)×109/L、(104.2±6.2)s,(19.7±14.3)×109/L、(74.0±9.2)s,P<0.05。以APCT≥90s为界点值,对预示血小板减少所致出血的敏感度为100%,特异性为93.7%;以Plt≤15×109/L为界点值,预示敏感度为95.8%,特异性为50.0%。22名患者输注血小板后1,24h的APCT均明显缩短,APCT由输注前的(103.7±11.3)s分别缩短为输注后1h的(60.0±9.7)s、24h的(68.5±9.8)s,P<0.01。18名患者血小板输注后24h的APCT均<80s,其出血症状均消失,但其中有1例CCI、3例PPR显示血小板输注无效;血小板输注后24h的APCT>80s的3名患者的出血症状无明显改善,而CCI、PPR只有1例显示血小板输注无效。结论APCT是血小板预防性输注的良好指征,其特异性明显优于Plt。APCT同时反映血小板数量和质量的变化,能较全面的评估血小板的输注疗效。  相似文献   

2.
手工分离血小板与单采血小板质量及输注疗效的对比研究   总被引:5,自引:1,他引:5  
目的对手工血小板和单采血小板的质量进行检测,比较2种血小板输注效果,评价手工血小板输注的治疗作用。方法对115个治疗量单采血小板、294袋(2U/袋)手工血小板的血小板含量计数,了解其质量;对113名患者输注前后的血小板数值进行检测,根据CCI值和临床症状进行疗效评估。结果单采血小板的平均计数为(2.35±0.54)×1011,合格率为75.65%;手工血小板平均计数为(0.62±0.25)×1011,合格率为85.37%。输注有效率测定,单采血小板组1h CCI(14.65±16.61)、24h CCI(9.59±16.67),手工血小板组1h CCI(16.96±14.65)、24h CCI(10.31±15.64),单采血小板组的输注有效率为52%、手工血小板组为63%。临床疗效观察,输后症状有明显改善者单采血小板组70%、手工血小板组57%。结论手工血小板Plt和CCI值均高于单采血小板;临床疗效接近单采血小板,临床手工血小板可结合患者实际情况合理使用。  相似文献   

3.
目的 通过对比血小板配型前后血小板的输注效果,评估血小板抗体检测及配型对血小板输注无效的临床意义.方法 以出血症状改善情况、血小板计数增高指数(CCI)、血小板恢复百分率(PPR)为标准,对比配型前后血小板的输注效果.结果 25例血小板输注无效患者的血小板抗体筛查阳性9例; 9例血小板抗体阳性患者血小板交叉配型前后血小板输注有效率差异有统计学意义(P<0.01),配型后输注的 1 h和24 h CCI、PPR数值明显高于配型前输注的.结论 血小板抗体检测及血小板配型输注可以为患者选择适用的血小板,提高单采血小板的输注有效率,避免滥用血小板.  相似文献   

4.
目的观察并比较机器单采法及手工法分离制备血小板制剂用于儿科血液病输注的效果。方法输注机器单采血小板患儿463例次为机采制剂组,输注手工分离血小板制剂患儿155例次为手工制剂组,分别在输注后24、48及72h作外周血血小板计数,观察临床止血效果、有无输血反应发生,计算血小板计数增加校正指数(CCI)、血小板回升率(PPR)、输注无效率、输血反应发生率等指标。结果输注后24、48、72h,机采制剂组:CCI分别为18.9、15.4、14.1,PPR分别为33.4%、27.8%、25.0%;手工制剂组:CCI分别为11.3、9.4、2.9,PPR分别为20.3%、10.3%、3.8%;机采法制剂组均明显高于手工制剂组(P<0.01)。机采制剂组输注无效率10.58%、输血反应发生率3.02%,手工制剂组相应为32.90%及11.61%,机采组虽都明显低于手工组,但两组均达到较好的临床止血目的,组间无差异。结论输注机器单采血小板制剂能更有效地提高血液病患儿的血小板值,减少其血小板输注无效及输血反应的发生。  相似文献   

5.
熊燕  胡俊  魏立繁 《检验医学与临床》2007,4(10):915-916,920
目的 比较冰冻血小板和新鲜血小板用于治疗血液病及创伤性失血后患者在止血与血小板计数方面存在的差异.方法 40例患者输注冰冻血小板,40例患者输注新鲜血小板.对血小板增高指数(CCI)和血小板回收率(PPR)、患者输注前后出血改善程度三方面进行评价.结果 输注冰冻血小板1 h CCI(5.8±1.4)×109、PPR 36%,24 h CCI(2.9±1.0)×109、PPR 18%.输注新鲜血小板1 h CCI(20.1±4.8)×109、PPR 72%,24 h CCI(16.0±6.1)×109、PPR 56%.CCI值和PPR值比较,P<0.05,提示外周血小板计数差异有统计学意义.输注冰冻血小板组平均提高血小板计数能力不及输新鲜血小板组高,但两组输注后患者出血情况均有改善.结论 在提高外周血小板计数方面两种制剂有差异,输新鲜血小板提升外周血小板计数效果好,输冰冻血小板效果差.评判冰冻血小板的效果,不以单纯外周血小板的计数指标评价,应综合评价.冰冻血小板只适用于应急止血,不适合常规使用,新鲜血小板是血液病患者的首选制剂.两种制剂在有效止血方面差异无统计学意义.  相似文献   

6.
目的 比较单采血小板与浓缩血小板的临床疗效.方法 对212例患者输注血小板前后的血小板数值进行检测,根据血小板计数增加指数(CCI)、血小板回收率(PPR)以及临床症状进行疗效评估.结果 单采血小板和浓缩血小板均有输注疗效,单采血小板有效率CCI 89.09%,PPR 93.64%,浓缩血小板有效率CCI 63.73%,PPR 69.61%;单采血小板组和浓缩血小板组在输注后1 h CCI、24 h CCI以及1 h PPR比较,差异有统计学意义(P<0.05),24 h PPR比较差异有统计学意义(P<0.01);两组在临床出血症状疗效比较差异有统计学意义(P<0.01).结论 对血小板减少的患者,输注单采血小板可明显提升外周血中的血小板数量,并能迅速起到止血的目的,防止大出血并发症,而浓缩血小板效果不显著.  相似文献   

7.
目的探讨血液病反复输血患者血小板抗体、交叉配型试验结果与血小板输注效果的关系。方法回顾性分析112例血液病反复输血患者临床资料,根据入院时血小板抗体检验结果将其分为阳性组与阴性组,配型到阴性或弱阳性供者标本纳入相合亚组,多次配型均为阳性供者标本纳入不合亚组。比较阳性组与阴性组首次输注后,相合亚组与不合亚组本次输注后,1 h、24 h血小板校正增高计数(CCI)及血小板回收率(PPR)差异,采用Spearman相关系数模型分析1 h、24 h血小板CCI及PPR与血小板抗体检验、交叉配型试验结果的相关性。结果阳性组1 h CCI、24 h CCI、1 h PPR、24 h PPR水平均明显低于阴性组(P<0.05),相合亚组1 h CCI、24 h CCI、1 h PPR、24 h PPR水平均明显高于不合亚组(P<0.05)。血小板抗体测试结果与1 h CCI、24 h CCI、1 h PPR、24 h PPR水平均呈显著负相关(P<0.05);交叉配型试验结果与1 h CCI、24 h CCI、1 h PPR、24 h PPR水平均呈显著正相关(P<0.05)。结论血小板抗体检测及交叉配型结果与反复输血患者血小板输注效果关系较为密切,临床需积极开展上述试验以避免不必要的血小板资源浪费。  相似文献   

8.
目的探讨血小板交叉配型技术在免疫性血小板输注无效患者中的应用。方法配合性输注的血小板交叉配型采用固相凝集法。比较24例患者随机输注及配合性输注后的输注效果(有效输注率及24h CCI值)并进行统计学分析。结果12例患者的配合性输注后其有效输注率为91.67%,其24h CCI平均值为4764.08±429.91;而12例随机输注组的有效输注率及24 h CCI平均值分别为8.33%和1335.08±1084.82。两个组别间的有效输注率及24h CCI平均值比较差异有统计学意义(P0.01)。结论对免疫因素所致血小板输注无效患者进行血小板交叉配型可以预防血小板输注无效的发生并提高其输注效果,从而提升血小板输注的安全性和有效性。  相似文献   

9.
目的评估血小板交叉配型和血小板抗原基因分型2种方法应用于血小板输注无效中的临床意义。方法采用血小板交叉配型和血小板抗原基因分型技术,以输注24 h后血小板恢复百分率(PPR)、血小板纠正计数指数(CCI)为指标,对比评估43名免疫性血小板输注无效患者配型前后血小板的输注效果。结果 43例血小板输注无效中,7例血小板抗原基因配型相合输注中,输注有效率100%,24 h PPR(34.24±6.59)%,24 h CCI为9.10±2.11;25例血小板交叉配型相合输注中,输注有效率92%(23/25),24 h PPR(32.43±7.50)%,24h CCI 9.18±2.82;11例随机血小板输注中,输注有效率27.3%(3/11),24 h PPR(16.45±9.37)%,24 h CCI 3.45±1.72。结论排除非免疫性因素及部分免疫因素,血小板抗原基因分型是提高血小板输注效果的首选措施,血小板交叉配合次之,二者均可明显提高血小板输注有效率,提升血小板输注的安全性和有效性。  相似文献   

10.
目的考查辐照血小板的临床疗效。方法将输注血小板3次以上的肿瘤患者分组,分别给予辐照单采血小板和辐照手工血小板,同时各设对照组,分别给予非辐照单采血小板和手工血小板,通过测定输注后CCI值及观察临床症状改善情况对输注疗效进行监测和评价。结果 308名患者CCI值测定,辐照单采组为6.18±11.4、辐照手工组为12.23±13.5;单采对照组为9.59±16.67、手工对照组为10.31±15.64;手工辐照组的输注有效率(66.67%)在各组中最高。临床疗效观察,患者输后有明显症状改善者辐照组和非辐照组分别为71%和65%;单采血小板和手工组分别为68%和63%。结论手工辐照血小板可用于缓解单采血小板供给不足情况下的患者输注。  相似文献   

11.
IntroductionTo determine an optimal platelet dose in thrombocytopenic patients is important for their judicious use. Transfusing platelets in different doses and comparing their post transfusion response can achieve this.AimTo compare the efficacy of low and high dose single donor apheresis platelets (SDAP) with standard dose transfusions in terms of Corrected Count Increment (CCI), Percent Platelet Recovery (PPR) and transfusion free interval.MethodIt was a prospective case control study done from January 2016 to April 2017. Twenty-eight hemato-oncology patients with CCI ≥5000 at 20–24 hours after standard dose (3 × 1011/unit), received low dose (1.5 × 1011 platelets/unit) and high dose (>4 × 1011 platelets/unit) SDAP. CCI and PPR were calculated after 20 to 24 hours of transfusion. Transfusion free interval and bleeding episodes were also noted. Grading was done according to WHO bleeding scale.ResultThere was no statistical difference in CCI and PPR when standard dose was compared with low dose (CCI: p = 0.92, PPR: p = 0.89). When standard and high dose was compared, standard dose gave better results than the high dose in terms of CCI (p = 0.006) and PPR (p = 0.008) although the post transfusion increments were comparable (p = 0.938). High dose gave better (p = 0.005) platelet count increments than low dose but CCI (p = 0.04) and PPR (p = 0.05) was significantly less than the low dose. The difference in transfusion free intervals after three doses was not significant. Donor exposure to the patients was significantly (p = 0.000) reduced to 17.5%.ConclusionPossibility of low dose as an alternative to standard dose can be considered in view of comparable platelet response indicators and significantly reduced donor exposure.  相似文献   

12.
目的观察急性白血病患者输注冷冻机采去白细胞血小板的临床疗效。方法检测68例急性白血病患者198例次输注冷冻机采去白细胞血小板前后1h和24h血小板值及血小板校正增加值(CCI),并进行临床疗效观察。结果 198例次输注后血小板计数(48.3±16.2)×109/L,显著高于输注前的(18.4±8.7)×109/L,差异有统计学意义(P<0.01)。1、24hCCI有效率分别为76.3%和45.5%。临床总有效166例次,总有效率为83.8%(166/198),无效或不良率为16.2%(32/198)。68例输注198例次冷冻机采去白细胞血小板患者无一例发生严重输血反应。结论冷冻机采去白细胞血小板可用于急性白血病化疗后骨髓抑制导致的血小板减少。  相似文献   

13.
目的 比较手工血小板和机采血小板的疗效,为临床输血提供参考依据.方法 样本来源于该院经过血小板输注治疗的住院患者,其中134例患者输用6 756 U手工血小板为A组;74例患者输用2 880 U机采血小板为B组.分别观察两组患者输注24 h后血小板校正增加指数(CCI)、血小板回收率(PPR)、临床出血症状有无改善、有无输血反应等进行输注后疗效判断.结果 与B组比较,A组CCI、PPR、总的输注有效率、输注反应率比较差异均无统计学意义(P〉0.05).结论 对于未产生同种免疫的患者,输注手工血小板或机采血小板,具有同等的安全性和有效性.因此,手工血小板的应用能够节约血液资源,缓解血小板供应紧张的现状.  相似文献   

14.
目的探讨血小板交叉配合试验对肿瘤患者血小板输注效果的临床价值。方法选择39例血小板相关抗体阳性的肿瘤患者,分为随机输注组与交叉配合输注组,计算输注后1h和24h血小板增加校正指数(CCI),判断血小板输注效果并进行比较分析。结果随机输注组与交叉配合输注组的1、24hCCI分别为(6.34±1.82)、(3.05±1.42)×109/L与(15.58±3.12)、(8.13±2.55)×109/L,差异有统计学意义(P0.05);血小板输注有效率分别为23.81%、83.33%与14.29%、72.22%,差异有统计学意义(P0.05)。结论对血小板相关抗体阳性的肿瘤患者进行输注前交叉配型可显著提高血小板输注的有效性。  相似文献   

15.
BACKGROUND: Corrected count increment (CCI) and percent platelet recovery (PPR) are measures of response to platelet transfusion that "correct" the count increment for blood volume and number of platelets transfused. Their potential for data distortion is described, and a regression analysis is suggested that is more informative and avoids the inherent problems associated with using ratios as outcome measures. STUDY DESIGN AND METHODS: Data from the first platelet transfusion for 585 patients from the Trial to Reduce Alloimmunization to Platelets (TRAP) were used to model methods of analyzing posttransfusion platelet response. RESULTS: By linear regression analysis, unfiltered platelet components gave a greater posttransfusion increment on average (p = 0.001), but filtered platelets gave a greater increment per platelet transfused (p = 0.003). In contrast, CCI and PPR showed no difference between filtered and unfiltered platelets (p = 0.36 and p = 0.29, respectively) because they combined the effects of dose, filtration, and patient size. Slightly fewer patients are required for a study analyzed by regression analysis. CONCLUSION: Regression analysis of posttransfusion platelet increments should be used instead of CCI or PPR to compare the efficacy of platelet components. CCI and PPR should not be used to define platelet refractoriness as a study outcome, because these measures are biased in favor of platelet preparation techniques that provide fewer platelets.  相似文献   

16.
C-PG血小板聚集试验在单采血小板捐献者筛查中的应用   总被引:1,自引:1,他引:1  
本研究探讨以阳离子没食子酸丙酯(C-PG)为激活剂的血小板聚集试验用于单采血小板捐献者筛查的可行性,并调查血小板献血者血小板功能缺陷的发生率.测定不同浓度C-PG诱导的健康献血者的血小板聚集率,以确定C-PG的最适应用浓度;检测30名志愿者服用阿司匹林前和服药24小时后的血小板聚集率,以确定血小板功能不良的筛查界点值;检测483例血小板捐献者的C-PG诱导的血小板聚集率,并对聚集功能不良者进行活化血浆凝固时间(APCT)测定.结果表明:血小板聚集率随C-PG浓度的增加而升高,当C-PG浓度达200μmol/L时,血小板聚集率达最高;服用阿司匹林24小时后的血小板聚集率与服药前相比,均表现明显减低(P<0.001),但以C-PG诱导180秒时的血小板聚集率减低最显著.血小板功能不良的筛查界点值确定为C-PG诱导180秒时的血小板聚集率小于20%;在483例血小板捐献者中,检出25例有血小板聚集功能不良,其中有11例表现为血小板促凝血活性减低.结论:C-PG诱导的血小板聚集试验能有效的检出血小板功能不良者,适用于血小板捐献者血小板功能的筛选;在血小板献血者中,血小板功能缺陷者的检出率大约为5%.  相似文献   

17.
目的探讨经血小板交叉配合试验的配合单采血小板的临床输注效果。方法选择30例反复输注血小板的血液病患者,其中15例应用单克隆抗体固相血小板抗体试验(M A SPAT)进行血小板交叉配合试验,另15例患者采用血小板随机输注,比较其临床效果,并于输注前及输注后1 h和24 h检测血小板计数,以血小板校正计数增值(CC I)判定输注效果。结果交叉配合试验组与随机输注组有效率分别为85.7%,28.1%,差异十分显著(P<0.01)。交叉配合试验组其CC I显著高于随机输注组(P<0.01)。结论经M A SPAT进行血小板交叉配合试验,能显著提高血小板临床输注效果。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号